TECHNICAL DATA
&
SERVICE MANUAL
FILE NO.
XH2672R / CH2672R, C2672R XH3672R / CH3672R, C3672R XH4272R / CH4272R, C4272R
TH2672R / CH2672R, C2672R TH3672R / CH3672R, C3672R TH4272R / CH4272R, C4272R THH2672R / CH2672R THH3672R / CH3672R
KH2672R / CH2672R, C2672R KH3072R / CH3072R, C3072R KH3672R / CH3672R, C3672R KHH2672R / CH2672R
UH2672R / CH2672R, C2672R UH3672R / CH3672R, C3672R
SPLIT SYSTEM AIR CONDITIONER
INDOOR MODEL No. |
PRODUCT CODE No. |
XH2672R |
854 028 32 |
|
|
XH3672R |
854 028 33 |
|
|
XH4272R |
854 031 89 |
|
|
TH2672R |
854 028 35 |
|
|
TH3672R |
854 028 36 |
|
|
TH4272R |
854 031 90 |
THH2672R |
854 028 38 |
|
|
THH3672R |
854 028 39 |
KH2672R |
854 028 28 |
|
|
KH3072R |
854 028 29 |
|
|
KH3672R |
854 028 30 |
KHH2672R |
854 028 31 |
|
|
UH2672R |
854 028 40 |
UH3672R |
854 028 41 |
|
|
Indoor Unit
XH2672R |
|
|
|
XH3672R |
||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
XH4272R |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
UH2672R |
UH3672R |
85464849248002 |
KHH2672R |
OUTDOOR MODEL No. |
PRODUCT CODE No. |
CH2672R |
854 028 20 |
|
|
CH3072R |
854 028 21 |
|
|
CH3672R |
854 028 22 |
|
|
CH4272R |
854 031 87 |
|
|
C2672R |
854 028 24 |
C3072R |
854 028 25 |
|
|
C3672R |
854 028 26 |
|
|
C4272R |
854 031 88 |
|
|
Outdoor Unit
|
|
|
TH2672R, THH2672R |
CH2672R, C2672R |
|
TH3672R, THH3672R |
CH3072R, C3072R |
|
TH4272R |
CH3672R, C3672R |
KH3072R
KH3672R
CH4272R, C4272R
KH2672R |
REFERENCE NO. SM831148-2 |
Section
1
2
3
4
5
6
Important
Please Read Before Starting
This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.
For safe installation and trouble-free operation, you must :
●Carefully read this instruction booklet before beginning.
●Follow each installation or repair step exactly as shown.
●Observe all local, state, and national electrical codes.
●Pay close attention to all warning and caution notices given in this manual.
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or
CAUTION
unsafe practice which can result in personal injury or product or property damage.
If Necessary, Get Help
These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.
SPECIAL PRECAUTIONS
When Wiring
.............................................................................................
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.
●Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.
●Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidentaly injury or death.
●Ground the unit following local electrical codes.
●Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
When Transporting
...............................................................................................
Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.
When Installing
.............................................................................................
…In a Room
Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.
…In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.
…In an area with High Winds
Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.
…In a Snowy Area (for Heat Pump-type Sys-tems)
Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.
When Connecting Refrigerant Tubing
.............................................................................................
●Ventilate the room well, in the event that refrigerant gas leaks during the installation. Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of poisonous gas.
●Keep all tubing runs as short as possible.
●Use the flare method for connecting tubing.
●Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection.
●Check carefully for leaks before starting the test run.
NOTE
Depending on the system type, liquid and gas lines may be either narrow or wide. Therefore, to avoid confusion the refrigerant tubing for your particular model is specified as either “narrow” or “wide” rather than as “liquid” or “gas”.
When Servicing
..............................................................................................
●Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.
●Keep your fingers and clothing away from any moving parts.
●Clean up the site when installation is finished. Check that no metal scraps or bits of wiring have been left inside the unit.
CAUTION
●Ventilate any enclosed areas when installing or testing the refrigeration system. Contact of refrigerant gas with fire or heat can produce poisonous gas.
●Confirm after installation that no refrigerant gas is leaking. If the gas comes in contact with a burning stove, gas water heater, electric room heater or other heat source, it can cause the generation of poisonous gas.
SM831148
i
Contents
Section 1: SPECIFICATIONS ................................................................................................. |
I-1 |
|
1-1 |
Unit Specifications .......................................................................................... |
I-2 |
1-2 |
Major Component Specifications .................................................................. |
I-27 |
1-3 |
Other Component Specifications .................................................................. |
I-47 |
1-4 |
Dimensional data .......................................................................................... |
I-63 |
1-5 |
Refrigerant Flow Diagram ............................................................................. |
I-74 |
1-6 |
Operating Range .......................................................................................... |
I-75 |
1-7 |
Heating Capacity .......................................................................................... |
I-76 |
1-8 |
Noise Criterion Curves.................................................................................. |
I-77 |
1-9 Increasing the Fan Speed ............................................................................. |
I-82 |
|
1-10 Air throw distance chart ................................................................................ |
I-83 |
|
1-11 Installation Instructions.................................................................................. |
I-86 |
|
1-12 Electrical Wiring ............................................................................................ |
I-98 |
|
1-13 Using Wireless Remote Controller with Wall-mounted Indoor Unit ............. |
I-102 |
Section 2: PROCESSES AND FUNCTIONS......................................................................... |
II-1 |
|
2-1 |
Room Temperature Control ............................................................................ |
II-2 |
2-2 Cold Draft Prevention (Heating Cycle) ........................................................... |
II-4 |
|
2-3 Automatic Fan Speed (Indoor Unit) ................................................................ |
II-5 |
|
2-4 |
Control Functions ........................................................................................... |
II-6 |
2-5 |
Outdoor Unit Control PCB .............................................................................. |
II-9 |
2-6 |
Outdoor Unit Control PCB (CR-CH4272R) .................................................. |
II-10 |
Section 3: ELECTRICAL DATA ............................................................................................ |
III-1 |
|
3-1 |
Indoor Units ................................................................................................... |
III-2 |
3-2 |
Outdoor Units .............................................................................................. |
III-16 |
Section 4: SERVICE PROCEDURES .................................................................................. |
IV-1 |
|
4-1 Meaning of Alarm Messages ......................................................................... |
IV-2 |
|
4-2 Symptoms and Parts to Inspect ..................................................................... |
IV-5 |
|
4-3 Details of Alarm Messages ........................................................................... |
IV-8 |
|
4-4 |
Table of Thermistor Characteristics ............................................................. |
IV-14 |
Section 5: OUTDOOR UNIT MAINTENANCE REMOTE CONTROL............................................... |
V-1 |
|
5-1 |
Overview ....................................................................................................... |
V-2 |
5-2 |
Functions ...................................................................................................... |
V-2 |
5-3 Normal Display Operations and Functions ................................................... |
V-3 |
|
5-4 Monitoring Operations: Display of Indoor Unit and Outdoor Unit Sensor |
|
|
|
Temperatures ................................................................................................ |
V-6 |
5-5 Monitoring the Outdoor Unit Alarm History: Display of Outdoor Unit |
|
|
|
Alarm History ................................................................................................ |
V-7 |
5-6 Setting Modes: Setting the Outdoor Unit EEPROM ....................................... |
V-7 |
|
Section 6: TEST RUN .......................................................................................................... |
VI-1 |
|
6-1 |
Preparing for Test Run ................................................................................. |
VI-2 |
6-2 |
Caution ........................................................................................................ |
VI-3 |
6-3 |
Test Run Procedure ..................................................................................... |
VI-3 |
6-4 Items to Check Before the Test Run ............................................................. |
VI-4 |
|
6-5 Test Run Using the Remote Controller ......................................................... |
VI-4 |
|
6-6 |
Precautions .................................................................................................. |
VI-4 |
6-7 Table of Self-Diagnostic Functions and Corrections (X, T, U, K Type) .......... |
VI-5 |
|
6-8 |
Examples of Wiring Diagrams ...................................................................... |
VI-6 |
1. Specifications
1. SPECIFICATIONS
1-1 |
Unit Specifications ......................................................................................................... |
I-2 |
1-2 |
Major Component Specifications ............................................................................... |
I-27 |
1-3 |
Other Component Specifications ............................................................................... |
I-47 |
1-4 |
Dimensional data ......................................................................................................... |
I-63 |
1-5 |
Refrigerant Flow Diagram............................................................................................ |
I-74 |
1-6 |
Operating Range .......................................................................................................... |
I-75 |
1-7 |
Heating Capacity .......................................................................................................... |
I-76 |
1-8 |
Noise Criterion Curves ................................................................................................ |
I-77 |
1-9 |
Increasing the Fan Speed ........................................................................................... |
I-82 |
1-10 |
Air throw distance chart .............................................................................................. |
I-83 |
1-11 |
Installation Instructions ............................................................................................... |
I-86 |
1-12 |
Electrical Wiring ........................................................................................................... |
I-98 |
1-13 Using Wireless Remote Controller with Wall-mounted Indoor Unit ........................ |
I-102 |
SM831148
I-1
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Wall-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
KHH2672R |
|
|
|||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
CH2672R |
|
|
||||||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
||||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
Heating |
|
||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
23,000 [9,500~23,000] |
|
27,600 [8,000~27,600] |
|
|||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
18,500 |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
7.4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
540 / 460 / 380 |
|
|
|
|
|
||||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
15.9 |
|
|
|
|
10.3 |
|
|
||||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
208 |
|
230 |
|
|
|
208 |
|
||||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
VAC 187 - 253 |
|
|||||||||||||
|
Max. Running amperes* (Without Back-up Heater) |
|
A |
14.0 |
|
15.5 |
|
14.6 |
|
|
|
16.1 |
|
|||||||||||
|
Power input |
|
|
W |
2,610 |
|
2,610 |
|
2,720 |
|
|
|
2,720 |
|
||||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
2,160 |
|
|
|
2,160 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
1.8 |
|
|
|
1.47 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 30 |
|
|
|
|
|
|
|||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
||||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH1UA / RCS-BH80UA. WL |
|
|
|||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
Air filter |
|
|
|
|
|
|
|
|
|
|
|
Washable |
|
|
|||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
||||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
45 / 42 / 40 |
|
|
|
|
|
|||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
49 |
|
|
|
|
|
|
|||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
||||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
||||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
|||||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
|||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
4.19 (1.9) - R410A |
|
|
|||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
14- 9/16 (370) |
|
3023/32 (780) |
|
||||||||||||||||
|
|
|
Width |
|
in. (mm) |
49- 7/32 (1,250) |
|
37 (940) |
|
|||||||||||||||
|
|
|
Depth |
|
in. (mm) |
8- 9/32 (210) |
|
13- 3/8 (340) |
|
|||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||||||||||
|
|
|
Height |
|
in. (mm) |
18- 7/16 (468) |
|
3431/32 (888) |
|
|||||||||||||||
|
|
|
Width |
|
in. (mm) |
5223/32 (1,339) |
|
3931/32 (1,015) |
|
|||||||||||||||
|
|
|
Depth |
|
in. (mm) |
11- 3/8 (289) |
|
16- 3/32 (409) |
|
|||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
44.1 (20) |
|
|
128 (58) |
|
|||||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
59.5 (27) |
|
|
148 (67) |
|
|||||||||||||||
|
Shipping volume |
|
|
cu.ft. (m 3 ) |
6.4 (0.181) |
|
|
13.0 (0.369) |
|
|||||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-2
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Wall-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
KH2672R |
|
|
||||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
CH2672R |
|
|
||||||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
|||||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
|
Heating |
|
||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
25,200 [9,500~25,200] |
|
29,200 [8,000~29,200] |
|
||||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
17,200 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
8.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
559 / 475 / 390 |
|
|
|
|
|
|||||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
14.9 |
|
|
|
|
10.2 |
|
|
|||||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
208 |
|
230 |
|
|
|
208 |
|
||||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
|
VAC 187 - 253 |
|
|||||||||||||
|
Max. Running amperes* |
|
|
A |
15.3 |
|
|
16.9 |
|
14.0 |
|
|
|
15.5 |
|
||||||||||
|
Power input |
|
|
W |
2,840 |
|
|
2,840 |
|
2,620 |
|
|
|
2,620 |
|
||||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
2,030 |
|
|
|
2,030 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 30 |
|
|
|
|
|
|
||||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
||||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
||||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
|||||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
|||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH1UA / RCS-BH80UA. WL |
|
|
||||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
Air filter |
|
|
|
|
|
|
|
|
|
|
|
Washable |
|
|
||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
48 / 42 / 38 |
|
|
|
|
|
||||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
49 |
|
|
|
|
|
|
||||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
|||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
|||||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
|||||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
||||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
|||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
||||||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
||||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
4.19 (1.9) - R410A |
|
|
||||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
|
Outdoor unit |
|
|||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
1263/64 (330) |
|
3023/32 (780) |
|
|||||||||||||||||
|
|
|
Width |
|
in. (mm) |
44- 7/8 (1,140) |
|
37 (940) |
|
||||||||||||||||
|
|
|
Depth |
|
in. (mm) |
8- 31/32 (228) |
|
13- 3/8 (340) |
|
||||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
|
Outdoor unit |
|
|||||||||||||
|
|
|
Height |
|
in. (mm) |
1511/32 (390) |
|
3431/32 (888) |
|
||||||||||||||||
|
|
|
Width |
|
in. (mm) |
4727/32 (1,215) |
|
3931/32 (1,015) |
|
||||||||||||||||
|
|
|
Depth |
|
in. (mm) |
1117/32 (293) |
|
16- 3/32 (409) |
|
||||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
|
40 (18) |
|
|
|
128 (58) |
|
||||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
|
44 (20) |
|
|
|
148 (67) |
|
||||||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
4.9 (0.139) |
|
|
13.0 (0.369) |
|
|||||||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-3
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Wall-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
KH3072R |
|
|
||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
CH3072R |
|
|
||||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
|||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
Heating |
|
||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
29,800 [9,500~29,800] |
|
34,800 [8,000~34,800] |
|
||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
20,000 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
9.7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
840 / 740 / 620 |
|
|
|
|
|
|||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
15.0 |
|
|
|
|
9.0 |
|
|
|||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
208 |
|
230 |
|
|
|
208 |
|
||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
VAC 187 - 253 |
|
|||||||||||||
|
Max. Running amperes* |
|
|
A |
17.7 |
|
|
19.6 |
|
16.2 |
|
|
|
17.9 |
|
||||||||
|
Power input |
|
|
W |
3,690 |
|
|
3,690 |
|
3,390 |
|
|
|
3,390 |
|
||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
2,460 |
|
|
|
2,460 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 35 |
|
|
|
|
|
|
||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
|||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
|||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH1UA / RCS-BH80UA. WL |
|
|
||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Air filter |
|
|
|
|
|
|
|
|
|
|
|
Washable |
|
|
||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
46 / 42 / 38 |
|
|
|
|
|
||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
52 |
|
|
|
|
|
|
||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
|||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
|||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
|||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
|||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
||||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
5.73 (2.6) - R410A |
|
|
||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
Outdoor unit |
|
|||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
14- 9/16 (370) |
|
3023/32 (780) |
|
|||||||||||||||
|
|
|
Width |
|
in. (mm) |
59- 1/16 (1,500) |
|
37 (940) |
|
||||||||||||||
|
|
|
Depth |
|
in. (mm) |
9- 7/16 (240) |
|
13- 3/8 (340) |
|
||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
Outdoor unit |
|
|||||||||||||
|
|
|
Height |
|
in. (mm) |
18- 7/16 (468) |
|
3431/32 (888) |
|
||||||||||||||
|
|
|
Width |
|
in. (mm) |
62- 9/16 (1,589) |
|
3931/32 (1,015) |
|
||||||||||||||
|
|
|
Depth |
|
in. (mm) |
12- 9/16 (319) |
|
16- 3/32 (409) |
|
||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
63.9 (29) |
|
|
143 (65) |
|
||||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
81.6 (37) |
|
|
161 (73) |
|
||||||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
8.4 (0.237) |
|
|
13.0 (0.369) |
|
|||||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-4
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Wall-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
KH3672R |
|
|
||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
CH3672R |
|
|
||||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
|||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
Heating |
|
||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
31,400 [9,500~31,400] |
|
36,400 [8,000~36,400] |
|
||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
20,200 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
10.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
830 / 710 / 590 |
|
|
|
|
|
|||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
15.9 |
|
|
|
|
9.0 |
|
|
|||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
208 |
|
230 |
|
|
|
208 |
|
||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
VAC 187 - 253 |
|
|||||||||||||
|
Max. Running amperes* |
|
|
A |
17.9 |
|
|
19.8 |
|
15.9 |
|
|
|
17.6 |
|
||||||||
|
Power input |
|
|
W |
3,750 |
|
|
3,750 |
|
3,320 |
|
|
|
3,320 |
|
||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
2,450 |
|
|
|
2,450 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 35 |
|
|
|
|
|
|
||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
|||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
|||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH1UA / RCS-BH80UA. WL |
|
|
||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Air filter |
|
|
|
|
|
|
|
|
|
|
|
Washable |
|
|
||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
48 / 44 / 40 |
|
|
|
|
|
||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
52 |
|
|
|
|
|
|
||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
|||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
|||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
|||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
|||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
||||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
6.17 (2.8) - R410A |
|
|
||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
Outdoor unit |
|
|||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
14- 9/16 (370) |
|
3023/32 (780) |
|
|||||||||||||||
|
|
|
Width |
|
in. (mm) |
59- 1/16 (1,500) |
|
37 (940) |
|
||||||||||||||
|
|
|
Depth |
|
in. (mm) |
9- 7/16 (240) |
|
13- 3/8 (340) |
|
||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
Outdoor unit |
|
|||||||||||||
|
|
|
Height |
|
in. (mm) |
18- 7/16 (468) |
|
3431/32 (888) |
|
||||||||||||||
|
|
|
Width |
|
in. (mm) |
62- 9/16 (1,589) |
|
3931/32 (1,015) |
|
||||||||||||||
|
|
|
Depth |
|
in. (mm) |
12- 9/16 (319) |
|
16- 3/32 (409) |
|
||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
72.8 (33) |
|
|
143 (65) |
|
||||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
90.4 (41) |
|
|
161 (73) |
|
||||||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
8.4 (0.237) |
|
|
13.0 (0.369) |
|
|||||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-5
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Wall-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
KH2672R |
|
|||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
C2672R |
|
|||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||
|
PERFORMANCE |
|
|
|
|
|
|
Cooling |
|
|||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
25,200 [9,500~25,200] |
|
|||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
|
|
|
8.1 |
|
|
||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
559 / 475 / 390 |
|
|||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
|
|
|
|
14.9 |
|
|
|||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
208 |
|
|||||
|
Available voltage range |
|
|
V |
|
|
|
|
VAC 187 - 253 |
|
||||||
|
Max. Running amperes* |
|
|
A |
15.3 |
|
|
|
|
16.9 |
|
|||||
|
Power input |
|
|
W |
2,840 |
|
|
|
|
2,840 |
|
|||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
15 / 30 |
|
|
|||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
Microprocessor |
|
||||||
|
Low ambient control |
|
|
|
|
|
|
|
Built-in 0˚F |
|
||||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH1UA / RCS-BH80UA. WL |
|
||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
/ Automatic (Vertical ) |
|
|||||||||
|
|
|
|
|
||||||||||||
|
Air filter |
|
|
|
|
|
|
|
Washable |
|
||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
(20A , OD26mm) |
|
||||||||
|
|
|
|
|
|
|||||||||||
|
Compressor |
|
|
|
|
|
|
Rotary(SANYO) |
|
|||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
48 / 42 / 38 |
|
||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
49 |
|
|
|||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
165 (50) |
|
|
||||
|
Limit of tubing length at shipment |
|
ft. (m) |
10~100 (3~30) |
|
|||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
3 / 8 (6.35) |
|
||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
5 / 8 (15.88) |
|
||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
4.19 (1.9) - R410A |
|
||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||
|
Unit dimensions |
Height |
|
in. (mm) |
1263/64 (330) |
|
3023/32 (780) |
|
||||||||
|
|
|
Width |
|
in. (mm) |
44- 7/8 (1,140) |
|
37 (940) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
8- 31/32 (228) |
|
13- 3/8 (340) |
|
|||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||
|
|
|
Height |
|
in. (mm) |
1511/32 (390) |
|
3431/32 (888) |
|
|||||||
|
|
|
Width |
|
in. (mm) |
4727/32 (1,215) |
|
3931/32 (1,015) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
1117/32 (293) |
|
16- 3/32 (409) |
|
|||||||
|
Net weight |
|
|
lbs. (kg) |
40 (18) |
|
|
|
128 (58) |
|
||||||
|
Shipping weight |
|
|
lbs. (kg) |
44 (20) |
|
|
|
148 (67) |
|
||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
4.9 (0.139) |
|
|
13.0 (0.369) |
|
||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Wall-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
KH3072R |
|
|||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
C3072R |
|
|||||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||||
|
PERFORMANCE |
|
|
|
|
|
|
Cooling |
|
|||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
29,800 [9,500~29,800] |
|
|||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
|
|
|
9.7 |
|
|
||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
840 / 740 / 620 |
|
|||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. |
|
|
BTU / Wh |
|
|
|
|
|
15.0 |
|
|
||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
|
|
208 |
|
|||||
|
Available voltage range |
|
|
V |
|
|
|
|
VAC 187 - 253 |
|
||||||||
|
Max. Running amperes* |
|
|
A |
17.7 |
|
|
|
|
|
|
19.6 |
|
|||||
|
Power input |
|
|
W |
3,690 |
|
|
|
|
|
|
3,690 |
|
|||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
15 / 35 |
|
|
|||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
Microprocessor |
|
||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|||||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH1UA / RCS-BH80UA. WL |
|
||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
/ Automatic (Vertical ) |
|
|||||||||||
|
|
|
|
|
||||||||||||||
|
Air filter |
|
|
|
|
|
|
|
|
Washable |
|
|||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
(20A , OD26mm) |
|
||||||||||
|
|
|
|
|
|
|
||||||||||||
|
Compressor |
|
|
|
|
|
|
Rotary(SANYO) |
|
|||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
46 / 42 / 38 |
|
||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
52 |
|
|
|||||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
165 (50) |
|
|
||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
10~100 (3~30) |
|
|||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
|
|
3 / 8 (6.35) |
|
|||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
5 / 8 (15.88) |
|
||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
5.73 (2.6) - R410A |
|
||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
|
|
Outdoor unit |
|
|||||
|
Unit dimensions |
Height |
|
in. (mm) |
14- 9/16 (370) |
|
|
|
3023/32 (780) |
|
||||||||
|
|
|
Width |
|
in. (mm) |
59- 1/16 (1,500) |
|
|
|
37 (940) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
9- 7/16 (240) |
|
|
|
13- 3/8 (340) |
|
|||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
|
|
Outdoor unit |
|
|||||
|
|
|
Height |
|
in. (mm) |
18- 7/16 (468) |
|
|
|
3431/32 (888) |
|
|||||||
|
|
|
Width |
|
in. (mm) |
62- 9/16 (1,589) |
|
|
|
3931/32 (1,015) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
12- 9/16 (319) |
|
|
|
16- 3/32 (409) |
|
|||||||
|
Net weight |
|
|
lbs. (kg) |
63.9 (29) |
|
|
|
|
143 (65) |
|
|||||||
|
Shipping weight |
|
|
lbs. (kg) |
81.6 (37) |
|
|
|
|
161 (73) |
|
|||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
8.4 (0.237) |
|
|
|
|
13.0 (0.369) |
|
||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-7
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Wall-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
KH3672R |
|
|||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
C3672R |
|
|||||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||||
|
PERFORMANCE |
|
|
|
|
|
|
Cooling |
|
|||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
31,400 [9,500~31,400] |
|
|||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
|
|
|
10.0 |
|
|
||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
830 / 710 / 590 |
|
|||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. |
|
|
BTU / Wh |
|
|
|
|
|
15.9 |
|
|
||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
|
|
208 |
|
|||||
|
Available voltage range |
|
|
V |
|
|
|
|
VAC 187 - 253 |
|
||||||||
|
Max. Running amperes* |
|
|
A |
17.9 |
|
|
|
|
|
|
19.8 |
|
|||||
|
Power input |
|
|
W |
3,750 |
|
|
|
|
|
|
3,750 |
|
|||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
15 / 35 |
|
|
|||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
Microprocessor |
|
||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|||||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH1UA / RCS-BH80UA. WL |
|
||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
/ Automatic (Vertical ) |
|
|||||||||||
|
|
|
|
|
||||||||||||||
|
Air filter |
|
|
|
|
|
|
|
|
Washable |
|
|||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
(20A , OD26mm) |
|
||||||||||
|
|
|
|
|
|
|
||||||||||||
|
Compressor |
|
|
|
|
|
|
Rotary(SANYO) |
|
|||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
48 / 44 / 40 |
|
||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
52 |
|
|
|||||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
165 (50) |
|
|
||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
10~100 (3~30) |
|
|||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
|
|
3 / 8 (6.35) |
|
|||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
5 / 8 (15.88) |
|
||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
6.17 (2.8) - R410A |
|
||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
|
|
Outdoor unit |
|
|||||
|
Unit dimensions |
Height |
|
in. (mm) |
14- 9/16 (370) |
|
|
|
3023/32 (780) |
|
||||||||
|
|
|
Width |
|
in. (mm) |
59- 1/16 (1,500) |
|
|
|
37 (940) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
9- 7/16 (240) |
|
|
|
13- 3/8 (340) |
|
|||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
|
|
Outdoor unit |
|
|||||
|
|
|
Height |
|
in. (mm) |
18- 7/16 (468) |
|
|
|
3431/32 (888) |
|
|||||||
|
|
|
Width |
|
in. (mm) |
62- 9/16 (1,589) |
|
|
|
3931/32 (1,015) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
12- 9/16 (319) |
|
|
|
16- 3/32 (409) |
|
|||||||
|
Net weight |
|
|
lbs. (kg) |
72.8 (33) |
|
|
|
|
143 (65) |
|
|||||||
|
Shipping weight |
|
|
lbs. (kg) |
90.4 (41) |
|
|
|
|
161 (73) |
|
|||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
8.4 (0.237) |
|
|
|
|
13.0 (0.369) |
|
||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-8
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
4-Way Air Discharge Semi-Concealed Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
XH2672R |
|
|
|
|
|
|||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
CH2672R |
|
|
|
|
|
|||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
||||||||||||||||||
|
PERFORMANCE |
|
Cooling |
|
|
|
|
|
|
Heating |
|
||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
24,800 [9,500~24,800] |
|
29,800 [8,000~29,800] |
|
||||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18,300 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
Moisture removal (High) |
|
|
Pints / h |
8.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
|
|
|
|
|
|
710 / 530 / 450 |
|
|
|
|
|
|||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
14.1 |
|
|
|
|
|
|
|
|
10.5 |
|
|||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
|
|
208 |
|
230 |
|
208 |
|
||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
|
VAC 187 - 253 |
|
|||||||||||||
|
Max. Running amperes* |
|
|
A |
15.6 |
|
|
|
|
|
|
17.3 |
|
14.8 |
|
16.4 |
|
||||||||
|
Power input |
|
|
W |
2,920 |
|
|
|
|
|
|
2,920 |
|
2,790 |
|
2,790 |
|
||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
2,200 |
|
2,200 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
|
|
15 / 30 |
|
|
|
|
|
|
||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|
|
|
|||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|
|
|
|||||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
|||||||||||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
|||||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA.WL / RCS-BH80UA. WL |
|
|||||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
Air filter |
|
|
|
|
|
Washable, long life (2,500 hr) |
|
|||||||||||||||||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
|||||||||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|
|
|
|||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
|
|
|
|
|
|
38 / 35 / 31 |
|
|
|
|
|
||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
49 |
|
|
|
|
|
|
||||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
|||||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
|
|
165 (50) |
|
|
|
|
|
|
|||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
|
|
|
|
|
|
10~100 (3~30) |
|
|
|
|
|
|||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
||||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
|||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
|
|
|
|
3 / 8 (6.35) |
|
|
|
|
|
||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
|
|
|
|
|
|
5 / 8 (15.88) |
|
|
|
|
|
||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
4.19 (1.9) - R410A |
|
|
|
|
|
|||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit (Include panel) |
Outdoor unit |
|
||||||||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
13-5/16 (338) |
|
|
|
|
|
|
3023/32 (780) |
|
||||||||||||
|
|
|
Width |
|
in. (mm) |
33-55/64 (860) |
|
|
|
|
|
|
37 (940) |
|
|||||||||||
|
|
|
Depth |
|
in. (mm) |
33-55/64 (860) |
|
|
|
|
|
|
13- 3/8 (340) |
|
|||||||||||
|
Package dimensions |
|
|
|
Body |
|
Panel |
Outdoor unit |
|
||||||||||||||||
|
|
|
Height |
|
in. (mm) |
11-9/64 (283) |
|
4-3/32 (104) |
3431/32 (888) |
|
|||||||||||||||
|
|
|
Width |
|
in. (mm) |
32-7/8 (835) |
|
37-61/64 (964) |
3931/32 (1,015) |
|
|||||||||||||||
|
|
|
Depth |
|
in. (mm) |
33-9/32 (845) |
|
39-21/64 (999) |
16- 3/32 (409) |
|
|||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
49 (22) |
|
|
|
|
|
11 (5) |
|
128 (58) |
|
|||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
57 (26) |
|
|
|
|
|
18 (8) |
|
148 (67) |
|
|||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
7.1 (0.200) |
|
|
3.6 (0.100) |
|
13.0 (0.369) |
|
|||||||||||||||
|
|
|
|
|
|
DATA SUBJECT |
TO CHANGE |
WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-9
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
4-Way Air Discharge Semi-Concealed Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
|
|
XH3672R |
|
|
|
|
|
||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
|
|
CH3672R |
|
|
|
|
|
||||||||
|
|
POWER SOURCE |
|
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
||||||||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
|
|
|
|
|
Heating |
|
|||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
32,600 [9,500~32,600] |
|
|
37,600 [8,000~37,600] |
|
||||||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20,000 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
10.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
|
|
|
|
|
|
|
|
1050 / 840 / 720 |
|
|
|
|
|
|
|||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
14.6 |
|
|
|
|
|
|
|
|
|
|
9.1 |
|
|||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
|
|
|
|
208 |
|
|
230 |
|
|
|
208 |
|
||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
VAC 187 - 253 |
|
|||||||||||||||||
|
Max. Running amperes* |
|
|
A |
18.7 |
|
|
|
|
|
|
|
|
20.7 |
|
|
15.9 |
|
|
|
17.6 |
|
||||||
|
Power input |
|
|
W |
3,950 |
|
|
|
3,950 |
|
|
3,350 |
|
|
3,350 |
|
||||||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
2,450 |
|
|
2,450 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
|
|
|
|
15 / 35 |
|
|
|
|
|
|
|
||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|
|
|
||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|
|
|
||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|||||||||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|||||||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
Air filter |
|
|
|
|
|
|
Washable, long life (2,500 hr) |
|
|||||||||||||||||||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
||||||||||||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|
|
|
||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
|
|
|
|
|
|
|
|
44 / 37 / 33 |
|
|
|
|
|
|
||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
|
|
|
52 |
|
|
|
|
|
|
|
|||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|||||||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
|
|
|
|
165 (50) |
|
|
|
|
|
|
|
|||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
|
|
|
|
|
|
|
|
10~100 (3~30) |
|
|
|
|
|
|
|||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
|
|
|
|
|
|
3 / 8 (6.35) |
|
|
|
|
|
|
||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
|
|
|
|
|
|
|
|
5 / 8 (15.88) |
|
|
|
|
|
|
||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
|
|
6.17 (2.8) - R410A |
|
|
|
|
|
||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit (Include panel) |
|
Outdoor unit |
|
||||||||||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
|
14-31/64 (368) |
|
|
|
|
|
|
|
3023/32 (780) |
|
|||||||||||||
|
|
|
Width |
|
in. (mm) |
|
45-9/32 (1,150) |
|
|
|
|
|
|
37 (940) |
|
|||||||||||||
|
|
|
Depth |
|
in. (mm) |
|
33-55/64 (860) |
|
|
|
|
|
|
|
13- 3/8 (340) |
|
||||||||||||
|
Package dimensions |
|
|
|
Body |
|
Panel |
|
Outdoor unit |
|
||||||||||||||||||
|
|
|
Height |
|
in. (mm) |
12-13/32 (315) |
|
|
4-3/32 (104) |
|
3431/32 (888) |
|
||||||||||||||||
|
|
|
Width |
|
in. (mm) |
44-19/64 (1,125) |
|
49-31/64 (1,257) |
3931/32 (1,015) |
|
||||||||||||||||||
|
|
|
Depth |
|
in. (mm) |
33-9/32 (845) |
|
|
39-21/64 (999) |
|
16- 3/32 (409) |
|
||||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
60 (27) |
|
|
|
|
|
|
16 (7) |
|
|
143 (65) |
|
||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
71 (32) |
|
|
|
|
|
|
22 (10) |
|
|
161 (73) |
|
||||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
10.6 (0.299) |
|
|
4.6 (0.131) |
|
|
13.0 (0.369) |
|
|||||||||||||||||
|
|
|
|
|
|
DATA SUBJECT |
TO CHANGE |
WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-10
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
4-Way Air Discharge Semi-Concealed Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
|
|
XH4272R |
|
|
|
|
|
||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
|
|
CH4272R |
|
|
|
|
|
||||||||
|
|
POWER SOURCE |
|
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
||||||||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
|
|
|
|
|
Heating |
|
|||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
39,500 [9,500~39,500] |
|
|
48,000 [8,000~48,000] |
|
||||||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
31,800 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
12.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
|
|
|
|
|
|
|
|
1050 / 840 / 720 |
|
|
|
|
|
|
|||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
14.6 |
|
|
|
|
|
|
|
|
|
|
10.4 |
|
|||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
|
|
|
|
208 |
|
|
230 |
|
|
|
208 |
|
||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
VAC 187 - 253 |
|
|||||||||||||||||
|
Max. Running amperes* |
|
|
A |
23.0 |
|
|
|
|
|
|
|
|
25.4 |
|
|
22.4 |
|
|
|
24.8 |
|
||||||
|
Power input |
|
|
W |
4,520 |
|
|
|
4,520 |
|
|
4,360 |
|
|
4,360 |
|
||||||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
3,540 |
|
|
3,540 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
|
|
|
|
15 / 40 |
|
|
|
|
|
|
|
||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|
|
|
||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|
|
|
||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|||||||||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|||||||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
Air filter |
|
|
|
|
|
|
Washable, long life (2,500 hr) |
|
|||||||||||||||||||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
||||||||||||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|
|
|
||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
|
|
|
|
|
|
|
|
45 / 38 / 34 |
|
|
|
|
|
|
||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
|
|
|
53 |
|
|
|
|
|
|
|
|||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|||||||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
|
|
|
|
165 (50) |
|
|
|
|
|
|
|
|||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
|
|
|
|
|
|
|
|
10~100 (3~30) |
|
|
|
|
|
|
|||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
|
|
|
|
|
|
3 / 8 (6.35) |
|
|
|
|
|
|
||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
|
|
|
|
|
|
|
|
5 / 8 (15.88) |
|
|
|
|
|
|
||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
|
|
7.94 (3.6) - R410A |
|
|
|
|
|
||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit (Include panel) |
|
Outdoor unit |
|
||||||||||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
|
14-31/64 (368) |
|
|
|
|
|
|
|
48-7/16 (1,230 ) |
|
|||||||||||||
|
|
|
Width |
|
in. (mm) |
|
45-9/32 (1,150) |
|
|
|
|
|
|
37 (940) |
|
|||||||||||||
|
|
|
Depth |
|
in. (mm) |
|
33-55/64 (860) |
|
|
|
|
|
|
|
13- 3/8 (340) |
|
||||||||||||
|
Package dimensions |
|
|
|
Body |
|
Panel |
|
Outdoor unit |
|
||||||||||||||||||
|
|
|
Height |
|
in. (mm) |
12-13/32 (315) |
|
|
4-3/32 (104) |
|
52-3/8 (1,330 ) |
|
||||||||||||||||
|
|
|
Width |
|
in. (mm) |
44-19/64 (1,125) |
|
49-31/64 (1,257) |
3931/32 (1,015) |
|
||||||||||||||||||
|
|
|
Depth |
|
in. (mm) |
33-9/32 (845) |
|
|
39-21/64 (999) |
|
16- 3/32 (409) |
|
||||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
60 (27) |
|
|
|
|
|
|
16 (7) |
|
|
220 (100) |
|
||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
71 (32) |
|
|
|
|
|
|
22 (10) |
|
|
240 (109 ) |
|
||||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
10.6 (0.299) |
|
|
4.6 (0.131) |
|
|
19.5 (0.552 ) |
|
|||||||||||||||||
|
|
|
|
|
|
DATA SUBJECT |
TO CHANGE |
WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-11
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
1. Specifications |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
4-Way Air Discharge Semi-Concealed Type |
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
XH2672R |
|
|
|||||
|
|
|
Outdoor Unit |
|
|
|
|
C2672R |
|
|
|||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
||||||||||
|
PERFORMANCE |
|
|
|
|
Cooling |
|
|
|||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
24,800 [9,500~24,800] |
|
||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
8.1 |
|
|
|
|||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
|
710 / 530 / 450 |
|
|
|||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
|
14.1 |
|
|
|
||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
|
|
208 |
|
||
|
Available voltage range |
|
|
V |
|
|
|
VAC 187 - 253 |
|
|
|||||
|
Max. Running amperes* |
|
|
A |
15.6 |
|
|
|
|
|
|
17.3 |
|
||
|
Power input |
|
|
W |
2,920 |
|
|
|
|
|
|
2,920 |
|
||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
15 / 30 |
|
|
|
||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
Microprocessor |
|
|
|||||
|
Low ambient control |
|
|
|
|
|
|
Built-in 0˚F |
|
|
|||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
|||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
|||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
|||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
/ Automatic (Vertical ) |
|
||||||||
|
|
|
|
||||||||||||
|
Air filter |
|
|
|
Washable, long life (2,500 hr) |
|
|||||||||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
|||||||||||
|
Compressor |
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
|
38 / 35 / 31 |
|
|
||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
49 |
|
|
|
||||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
|||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
165 (50) |
|
|
|
|||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
|
10~100 (3~30) |
|
|
|||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
|||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
3 / 8 (6.35) |
|
|
||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
|
5 / 8 (15.88) |
|
|
||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
4.19 (1.9) - R410A |
|
|
|||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit (Include panel) |
Outdoor unit |
|
||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
13-5/16 (338) |
|
|
|
|
3023/32 (780) |
|
||||
|
|
|
Width |
|
in. (mm) |
33-55/64 (860) |
|
|
|
|
37 (940) |
|
|||
|
|
|
Depth |
|
in. (mm) |
33-55/64 (860) |
|
|
|
|
13- 3/8 (340) |
|
|||
|
Package dimensions |
|
|
|
Body |
|
Panel |
Outdoor unit |
|
||||||
|
|
|
Height |
|
in. (mm) |
11-9/64 (283) |
|
4-3/32 (104) |
3431/32 (888) |
|
|||||
|
|
|
Width |
|
in. (mm) |
32-7/8 (835) |
|
37-61/64 (964) |
3931/32 (1,015) |
|
|||||
|
|
|
Depth |
|
in. (mm) |
33-9/32 (845) |
|
39-21/64 (999) |
16- 3/32 (409) |
|
|||||
|
Net weight |
|
|
lbs. (kg) |
49 (22) |
|
|
11 (5) |
|
128 (58) |
|
||||
|
Shipping weight |
|
|
lbs. (kg) |
57 (26) |
|
|
18 (8) |
|
148 (67) |
|
||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
7.1 (0.200) |
|
|
3.6 (0.100) |
|
13.0 (0.369) |
|
|||||
|
|
|
|
|
|
DATA SUBJECT |
TO CHANGE |
WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-12
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
4-Way Air Discharge Semi-Concealed Type |
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
XH3672R |
|
|
|||||
|
|
|
Outdoor Unit |
|
|
|
|
|
C3672R |
|
|
|||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||
|
PERFORMANCE |
|
|
|
|
|
Cooling |
|
|
|||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
32,600 [9,500~32,600] |
|
|||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
|
10.6 |
|
|
|
|||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
|
|
1050 / 840 / 720 |
|
|
|||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
|
|
14.6 |
|
|
|
||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
|
|
|
208 |
|
||
|
Available voltage range |
|
|
V |
|
|
|
|
VAC 187 - 253 |
|
|
|||||
|
Max. Running amperes* |
|
|
A |
18.7 |
|
|
|
|
|
|
|
20.7 |
|
||
|
Power input |
|
|
W |
3,950 |
|
|
|
|
|
|
|
3,950 |
|
||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
15 / 35 |
|
|
|
||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
Microprocessor |
|
|
|||||
|
Low ambient control |
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
/ Automatic (Vertical ) |
|
||||||||
|
|
|
|
|
||||||||||||
|
Air filter |
|
|
|
Washable, long life (2,500 hr) |
|
||||||||||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
||||||||||||
|
Compressor |
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
|
|
44 / 37 / 33 |
|
|
||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
52 |
|
|
|
||||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
165 (50) |
|
|
|
|||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
|
|
10~100 (3~30) |
|
|
|||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
3 / 8 (6.35) |
|
|
||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
|
|
5 / 8 (15.88) |
|
|
||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
6.17 (2.8) - R410A |
|
|
|||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit (Include panel) |
Outdoor unit |
|
|||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
14-31/64 (368) |
|
|
|
|
3023/32 (780) |
|
|||||
|
|
|
Width |
|
in. (mm) |
45-9/32 (1,150) |
|
|
|
|
37 (940) |
|
||||
|
|
|
Depth |
|
in. (mm) |
33-55/64 (860) |
|
|
|
|
13- 3/8 (340) |
|
||||
|
Package dimensions |
|
|
|
Body |
|
Panel |
Outdoor unit |
|
|||||||
|
|
|
Height |
|
in. (mm) |
12-13/32 (315) |
|
|
4-3/32 (104) |
3431/32 (888) |
|
|||||
|
|
|
Width |
|
in. (mm) |
44-19/64 (1,125) |
|
49-31/64 (1,257) |
3931/32 (1,015) |
|
||||||
|
|
|
Depth |
|
in. (mm) |
33-9/32 (845) |
|
|
39-21/64 (999) |
16- 3/32 (409) |
|
|||||
|
Net weight |
|
|
lbs. (kg) |
60 (27) |
|
|
|
16 (7) |
|
143 (65) |
|
||||
|
Shipping weight |
|
|
lbs. (kg) |
71 (32) |
|
|
|
22 (10) |
|
161 (73) |
|
||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
10.6 (0.299) |
|
|
4.6 (0.131) |
|
13.0 (0.369) |
|
||||||
|
|
|
|
|
|
DATA SUBJECT |
TO CHANGE |
WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-13
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
4-Way Air Discharge Semi-Concealed Type |
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
XH4272R |
|
|
|||||
|
|
|
Outdoor Unit |
|
|
|
|
|
C4272R |
|
|
|||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||
|
PERFORMANCE |
|
|
|
|
|
Cooling |
|
|
|||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
39,500 [9,500~39,500] |
|
|||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
|
12.6 |
|
|
|
|||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
|
|
1050 / 840 / 720 |
|
|
|||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
|
|
14.6 |
|
|
|
||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
|
|
|
208 |
|
||
|
Available voltage range |
|
|
V |
|
|
|
|
VAC 187 - 253 |
|
|
|||||
|
Max. Running amperes* |
|
|
A |
23.0 |
|
|
|
|
|
|
|
25.4 |
|
||
|
Power input |
|
|
W |
4,520 |
|
|
|
|
|
|
|
4,520 |
|
||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
15 / 40 |
|
|
|
||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
Microprocessor |
|
|
|||||
|
Low ambient control |
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
/ Automatic (Vertical ) |
|
||||||||
|
|
|
|
|
||||||||||||
|
Air filter |
|
|
|
Washable, long life (2,500 hr) |
|
||||||||||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
||||||||||||
|
Compressor |
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
|
|
45 / 38 / 34 |
|
|
||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
53 |
|
|
|
||||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
165 (50) |
|
|
|
|||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
|
|
10~100 (3~30) |
|
|
|||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
3 / 8 (6.35) |
|
|
||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
|
|
5 / 8 (15.88) |
|
|
||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
7.94 (3.6) - R410A |
|
|
|||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit (Include panel) |
Outdoor unit |
|
|||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
14-31/64 (368) |
|
|
|
|
48-7/16 (1,230 ) |
|
|||||
|
|
|
Width |
|
in. (mm) |
45-9/32 (1,150) |
|
|
|
|
37 (940) |
|
||||
|
|
|
Depth |
|
in. (mm) |
33-55/64 (860) |
|
|
|
|
13- 3/8 (340) |
|
||||
|
Package dimensions |
|
|
|
Body |
|
Panel |
Outdoor unit |
|
|||||||
|
|
|
Height |
|
in. (mm) |
12-13/32 (315) |
|
|
4-3/32 (104) |
52-3/8 (1,330 ) |
|
|||||
|
|
|
Width |
|
in. (mm) |
44-19/64 (1,125) |
|
49-31/64 (1,257) |
3931/32 (1,015) |
|
||||||
|
|
|
Depth |
|
in. (mm) |
33-9/32 (845) |
|
|
39-21/64 (999) |
16- 3/32 (409) |
|
|||||
|
Net weight |
|
|
lbs. (kg) |
60 (27) |
|
|
|
16 (7) |
|
220 (100) |
|
||||
|
Shipping weight |
|
|
lbs. (kg) |
71 (32) |
|
|
|
22 (10) |
|
240 (109 ) |
|
||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
10.6 (0.299) |
|
|
4.6 (0.131) |
|
19.5 (0.552 ) |
|
||||||
|
|
|
|
|
|
DATA SUBJECT |
TO CHANGE |
WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-14
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Concealed-Duct Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
UH2672R |
|
|
|
|
|
||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
CH2672R |
|
|
|
|
|
|||||||
|
|
POWER SOURCE |
|
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
|
Heating |
|
|||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
24,000 [9,500~24,000] |
|
28,600 [8,000~28,600] |
|
|||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
17,100 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
7.7 |
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
670 / 530 / 460 |
|
|
|
|
|
||||||||||||
|
External Static Pressure |
|
|
in.WG |
0.2:at shipment / 0.4:using jumper cable |
|
||||||||||||||||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
14.0 |
|
|
|
|
|
9.7 |
|
||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
208 |
|
230 |
|
208 |
|
||||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
VAC 187 - 253 |
|
|||||||||||
|
Max. Running amperes* |
|
|
A |
13.6 |
|
15.0 |
|
12.5 |
|
13.8 |
|
||||||||||
|
Power input |
|
|
W |
2,600 |
|
2,600 |
|
2,400 |
|
2,400 |
|
||||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
1,980 |
|
1,980 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 30 |
|
|
|
|
|
|
|||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|
|
|
||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|
|
|
||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|||||||||||||||||
|
Optional Wireless Remote Controller |
|
|
|
|
|
|
|
RCS-BH80UA. WL |
|
|
|
|
|
||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Air filter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
||||||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|
|
|
||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
34 / 30 / 27 |
|
|
|
|
|
|||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
49 |
|
|
|
|
|
|
|||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
|||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
|||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
4.19 (1.9) - R410A |
|
|
|
|
|
|||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
12-7/32 (310) |
|
3023/32 (780) |
|
||||||||||||||
|
|
|
Width |
|
in. (mm) |
39-3/8 (1,000) |
|
|
|
|
|
37 (940) |
|
|||||||||
|
|
|
Depth |
|
in. (mm) |
24-13/16 (630) |
|
13- 3/8 (340) |
|
|||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||||||||
|
|
|
Height |
|
in. (mm) |
14-3/32 (358) |
|
3431/32 (888) |
|
|||||||||||||
|
|
|
Width |
|
in. (mm) |
46-7/8 (1,191) |
|
3931/32 (1,015) |
|
|||||||||||||
|
|
|
Depth |
|
in. (mm) |
30-13/16 (783) |
|
16- 3/32 (409) |
|
|||||||||||||
|
Net weight |
|
|
lbs. (kg) |
|
71 (32) |
|
|
|
|
|
128 (58) |
|
|||||||||
|
Shipping weight |
|
|
lbs. (kg) |
|
82 (37) |
|
|
|
|
|
148 (67) |
|
|||||||||
|
Shipping volume |
|
|
cu.ft. (m 3 ) |
11.8 (0.334) |
|
13.0 (0.369) |
|
||||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-15
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Concealed-Duct Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
UH3672R |
|
|
|
|
|
||||||
|
|
|
Outdoor Unit |
|
|
|
|
CH3672R |
|
|
|
|
|
|||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
|
Heating |
|
|||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
31,200 [9,500~31,200] |
|
36,200 [8,000~36,200] |
|
|||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
20,200 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
10.0 |
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
670 / 530 / 460 |
|
|
|
|
|
||||||||||
|
External Static Pressure |
|
|
in. WG |
0.24:at shipment / 0.4:using jumper cable |
|
||||||||||||||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
13.9 |
|
|
|
|
|
8.7 |
|
||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
208 |
|
230 |
|
208 |
|
||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
VAC 187 - 253 |
|
|||||||||
|
Max. Running amperes* |
|
|
A |
18.6 |
|
20.6 |
|
15.9 |
|
17.6 |
|
||||||||
|
Power input |
|
|
W |
3,920 |
|
3,920 |
|
3,340 |
|
3,340 |
|
||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
2,570 |
|
2,570 |
|
|||||
|
|
|
|
|
|
|
|
|
||||||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 35 |
|
|
|
|
|
|
|||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
Microprocessor |
|
|
|
|
|
||||||
|
Low ambient control |
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|
|
|
||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|||||||||||||||
|
Optional Wireless Remote Controller |
|
|
|
|
|
RCS-BH80UA. WL |
|
|
|
|
|
||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Air filter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
||||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|
|
|
||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
38 / 33 / 31 |
|
|
|
|
|
|||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
52 |
|
|
|
|
|
|
|||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
|||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
|||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
6.17 (2.8) - R410A |
|
|
|
|
|
|||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
12-7/32 (310) |
|
3023/32 (780) |
|
||||||||||||
|
|
|
Width |
|
in. (mm) |
58-9/32 (1,480) |
|
|
|
|
|
37 (940) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
24-13/16 (630) |
|
13- 3/8 (340) |
|
|||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||||||
|
|
|
Height |
|
in. (mm) |
14-3/32 (358) |
|
3431/32 (888) |
|
|||||||||||
|
|
|
Width |
|
in. (mm) |
65-25/32 (1,671) |
|
3931/32 (1,015) |
|
|||||||||||
|
|
|
Depth |
|
in. (mm) |
30-13/16 (783) |
|
16- 3/32 (409) |
|
|||||||||||
|
Net weight |
|
|
lbs. (kg) |
|
104 (47) |
|
|
|
|
|
143 (65) |
|
|||||||
|
Shipping weight |
|
|
lbs. (kg) |
|
115 (52) |
|
|
|
|
|
161 (73) |
|
|||||||
|
Shipping volume |
|
|
cu.ft. (m 3 ) |
16.5 0.468) |
|
13.0 (0.369) |
|
||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-16
1-1 Unit Specifications |
|
|
|
|
|
|
1. Specifications |
|||
|
|
|
|
|
|
|
|
|||
|
Concealed-Duct Type |
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
MODEL No. |
|
Indoor Unit |
|
|
UH2672R |
|
|||
|
|
|
Outdoor Unit |
|
C2672R |
|
||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||
|
PERFORMANCE |
|
|
Cooling |
|
|||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
24,000 [9,500~24,000] |
|
|||||
|
|
|
(17˚F)** |
|
BTU / h |
|
— |
|
||
|
Moisture removal (High) |
|
|
Pints / h |
|
7.7 |
|
|
||
|
Air circulation (H / M / L) 230 V |
|
CFM |
670 / 530 / 460 |
|
|||||
|
External Static Pressure |
|
|
in. WG |
0.2:at shipment / 0.4:using jumper cable |
|
||||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
14.0 |
|
|
|||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
208 |
|
||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
||||
|
Max. Running amperes* |
|
|
A |
13.6 |
|
15.0 |
|
||
|
Power input |
|
|
W |
2,600 |
|
2,600 |
|
||
|
|
|
(17˚F)** |
|
W |
|
— |
|
||
|
Back-up Heater |
|
|
kW |
|
— |
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 30 |
|
|
|||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
Microprocessor |
|
||||
|
Low ambient control |
|
|
|
|
Built-in 0˚F |
|
|||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||
|
Optional Wireless Remote Controller |
|
RCS-BH80UA. WL |
|
||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
— |
|
|||||
|
Air filter |
|
|
|
|
— |
|
|||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
||||||
|
Compressor |
|
|
|
Rotary(SANYO) |
|
||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
34 / 30 / 27 |
|
|||
|
|
|
Outdoor - Hi |
|
dB - A |
|
49 |
|
|
|
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
||
|
Limit of tubing length at shipment |
|
ft. (m) |
10~100 (3~30) |
|
|||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
4.19 (1.9) - R410A |
|
|||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
Outdoor unit |
|
|
|
Unit dimensions |
Height |
|
in. (mm) |
12-7/32 (310) |
|
3023/32 (780) |
|
||
|
|
|
Width |
|
in. (mm) |
39-3/8 (1,000) |
|
37 (940) |
|
|
|
|
|
Depth |
|
in. (mm) |
24-13/16 (630) |
|
13- 3/8 (340) |
|
|
|
Package dimensions |
|
|
|
Indoor unit |
|
|
Outdoor unit |
|
|
|
|
|
Height |
|
in. (mm) |
14-3/32 (358) |
|
3431/32 (888) |
|
|
|
|
|
Width |
|
in. (mm) |
46-7/8 (1,191) |
|
3931/32 (1,015) |
|
|
|
|
|
Depth |
|
in. (mm) |
30-13/16 (783) |
|
16- 3/32 (409) |
|
|
|
Net weight |
|
|
lbs. (kg) |
71 (32) |
|
128 (58) |
|
||
|
Shipping weight |
|
|
lbs. (kg) |
82 (37) |
|
148 (67) |
|
||
|
Shipping volume |
|
|
cu.ft. (m 3 ) |
11.8 (0.334) |
|
13.0 (0.369) |
|
||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-17
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
1. Specifications |
||||
|
|
|
|
|
|
|
|
||||
|
Concealed-Duct Type |
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
MODEL No. |
|
|
Indoor Unit |
|
|
UH3672R |
|
|||
|
|
|
|
Outdoor Unit |
|
C3672R |
|
||||
|
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||
|
|
PERFORMANCE |
|
|
Cooling |
|
|||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
31,200 [9,500~31,200] |
|
||||||
|
|
|
|
(17˚F)** |
|
BTU / h |
|
— |
|
||
|
Moisture removal (High) |
|
|
Pints / h |
|
10.0 |
|
|
|||
|
Air circulation (H / M / L) 230 V |
|
CFM |
670 / 530 / 460 |
|
||||||
|
External Static Pressure |
|
|
in. WG |
0.24:at shipment / 0.4:using jumper cable |
|
|||||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
13.9 |
|
|
||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|||
|
Voltage rating |
|
|
|
|
V |
230 |
|
208 |
|
|
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|||||
|
Max. Running amperes* |
|
|
A |
18.6 |
|
20.6 |
|
|||
|
Power input |
|
|
|
|
W |
3,920 |
|
3,920 |
|
|
|
|
|
|
(17˚F)** |
|
W |
|
— |
|
||
|
Back-up Heater |
|
|
kW |
|
— |
|
||||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 35 |
|
|
||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
Controls |
Microprocessor |
|
Microprocessor |
|
||||||
|
Low ambient control |
|
|
|
Built-in 0˚F |
|
|||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
|||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
|||||||
|
Optional Wireless Remote Controller |
|
RCS-SH1UA / RCS-BH80UA. WL |
|
|||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
— |
|
||||||
|
Air filter |
|
|
|
|
|
|
— |
|
||
|
Drain pump (Drain connection) |
|
Max.head 2-33/64 in. above drain connection (25A , OD32mm) |
|
|||||||
|
Compressor |
|
|
|
|
|
Rotary(SANYO) |
|
|||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
38 / 33 / 31 |
|
|||||
|
|
|
|
Outdoor - Hi |
|
dB - A |
|
52 |
|
|
|
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
|||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
||
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|||
|
Limit of tubing length at shipment |
|
ft. (m) |
10~100 (3~30) |
|
||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
|||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
||||
|
outer diameter |
|
|
Wide tube |
|
in. (mm) |
5 / 8 (15.88) |
|
|||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
6.17 (2.8) - R410A |
|
||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
Outdoor unit |
|
||
|
Unit dimensions |
Height |
|
in. (mm) |
12-7/32 (310) |
|
3023/32 (780) |
|
|||
|
|
|
|
Width |
|
in. (mm) |
58-9/32 (1,480) |
|
37 (940) |
|
|
|
|
|
|
Depth |
|
in. (mm) |
24-13/16 (630) |
|
13- 3/8 (340) |
|
|
|
Package dimensions |
|
|
|
Indoor unit |
|
|
Outdoor unit |
|
||
|
|
|
|
Height |
|
in. (mm) |
14-3/32 (358) |
|
3431/32 (888) |
|
|
|
|
|
|
Width |
|
in. (mm) |
65-25/32 (1,671) |
|
3931/32 (1,015) |
|
|
|
|
|
|
Depth |
|
in. (mm) |
30-13/16 (783) |
|
16- 3/32 (409) |
|
|
|
Net weight |
|
|
|
|
lbs. (kg) |
104 (47) |
|
143 (65) |
|
|
|
Shipping weight |
|
|
lbs. (kg) |
115 (52) |
|
161 (73) |
|
|||
|
Shipping volume |
|
|
cu.ft. (m 3 ) |
16.5 0.468) |
|
13.0 (0.369) |
|
|||
|
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-18
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Ceiling-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
THH2672R |
|
|
||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
CH2672R |
|
|
|||||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
|||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
Heating |
|
|||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
24,400 [9,500~24,400] |
|
30,800 [8,000~30,800] |
|
||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
17,900 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
7.7 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
550 / 490 / 460 |
|
|
|
|
||||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
14.5 |
|
|
|
10.3 |
|
|
||||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
208 |
|
230 |
|
|
208 |
|
||||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
VAC 187 - 253 |
|
||||||||||||
|
Max. Running amperes* (Without Back-up Heater) |
|
A |
15.6 |
|
17.3 |
|
16.4 |
|
|
18.1 |
|
|||||||||||
|
Power input |
|
|
W |
2,880 |
|
2,880 |
|
3,000 |
|
|
3,000 |
|
||||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
2,190 |
|
|
2,190 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
1.8 |
|
|
1.47 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 30 |
|
|
|
|
|
|||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
|||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
|||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
|||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Air filter |
|
|
|
|
|
Washable, long life (2,500 hr) |
|
|
||||||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
39 / 37 / 33 |
|
|
|
|
|||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
49 |
|
|
|
|
|
|||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
|||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
||||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
||||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
|||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|||||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
4.19 (1.9) - R410A |
|
|
||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
7-17/32 (190) |
|
3023/32 (780) |
|
|||||||||||||||
|
|
|
Width |
|
in. (mm) |
51-3/16 (1,300) |
|
37 (940) |
|
||||||||||||||
|
|
|
Depth |
|
in. (mm) |
26-3/8 (670) |
|
13- 3/8 (340) |
|
||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
||||||||||||
|
|
|
Height |
|
in. (mm) |
9-7/16 (240) |
|
3431/32 (888) |
|
||||||||||||||
|
|
|
Width |
|
in. (mm) |
54-19/32 (1,387) |
|
3931/32 (1,015) |
|
||||||||||||||
|
|
|
Depth |
|
in. (mm) |
31-1/16 (789) |
|
16- 3/32 (409) |
|
||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
|
64 (29) |
|
|
|
128 (58) |
|
||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
|
75 (34) |
|
|
|
148 (67) |
|
||||||||||||
|
Shipping volume |
|
|
cu.ft. (m 3 ) |
8.9 (0.253) |
|
|
13.0 (0.369) |
|
||||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-19
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Ceiling-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
MODEL No. |
|
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
|
TH2672R |
|
|
||||||||||
|
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
|
CH2672R |
|
|
||||||||||
|
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
||||||||||||||||||
|
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
|
Heating |
|
|||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
24,400 [9,500~24,400] |
|
30,800 [8,000~30,800] |
|
||||||||||||||||||||
|
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
17,900 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
7.7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
550 / 490 / 460 |
|
|
|
|
|
|||||||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
14.5 |
|
|
|
|
10.3 |
|
|
|||||||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Voltage rating |
|
|
|
|
V |
230 |
|
208 |
|
230 |
|
|
|
208 |
|
|||||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
|
VAC 187 - 253 |
|
|||||||||||||||
|
Max. Running amperes* (Without Back-up Heater) |
|
A |
15.6 |
|
17.3 |
|
16.4 |
|
|
|
18.1 |
|
||||||||||||||
|
Power input |
|
|
|
|
W |
2,880 |
|
2,880 |
|
3,000 |
|
|
|
3,000 |
|
|||||||||||
|
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
2,190 |
|
|
|
2,190 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 30 |
|
|
|
|
|
|
||||||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
Microprocessor |
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|||||||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
|||||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
|||||||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
|||||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
|||||||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
Air filter |
|
|
|
|
|
|
|
Washable, long life (2,500 hr) |
|
|
||||||||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
||||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
39 / 37 / 33 |
|
|
|
|
|
||||||||||||||||
|
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
|
49 |
|
|
|
|
|
|
||||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
|||||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
|||||||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
|||||||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
||||||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
|||||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
||||||||||||||||
|
outer diameter |
|
|
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
||||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
|
4.19 (1.9) - R410A |
|
|
|||||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
|
Outdoor unit |
|
|||||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
7-17/32 (190) |
|
3023/32 (780) |
|
|||||||||||||||||||
|
|
|
|
Width |
|
in. (mm) |
51-3/16 (1,300) |
|
37 (940) |
|
|||||||||||||||||
|
|
|
|
Depth |
|
in. (mm) |
26-3/8 (670) |
|
13- 3/8 (340) |
|
|||||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
|
Outdoor unit |
|
|||||||||||||||
|
|
|
|
Height |
|
in. (mm) |
9-7/16 (240) |
|
3431/32 (888) |
|
|||||||||||||||||
|
|
|
|
Width |
|
in. (mm) |
54-19/32 (1,387) |
|
3931/32 (1,015) |
|
|||||||||||||||||
|
|
|
|
Depth |
|
in. (mm) |
31-1/16 (789) |
|
16- 3/32 (409) |
|
|||||||||||||||||
|
Net weight |
|
|
|
|
lbs. (kg) |
|
57 (26) |
|
|
|
|
128 (58) |
|
|||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
|
68 (31) |
|
|
|
|
148 (67) |
|
|||||||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
8.9 (0.253) |
|
|
13.0 (0.369) |
|
|||||||||||||||||||
|
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-20
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Ceiling-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
MODEL No. |
|
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
|
THH3672R |
|
|
|||||||||
|
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
CH3672R |
|
|
||||||||||
|
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
|||||||||||||||||
|
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
Heating |
|
|||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
31,200 [9,500~31,200] |
|
37,400 [8,000~37,400] |
|
|||||||||||||||||||
|
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
21,000 |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
10.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
1100 / 930 / 750 |
|
|
|
|
|
||||||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
15.1 |
|
|
|
|
9.6 |
|
|
||||||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Voltage rating |
|
|
|
|
V |
230 |
|
|
|
208 |
|
230 |
|
|
|
208 |
|
||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
VAC 187 - 253 |
|
|||||||||||||||
|
Max. Running amperes* |
|
|
A |
18.2 |
|
|
|
20.1 |
|
15.6 |
|
|
|
17.3 |
|
||||||||||
|
Power input |
|
|
|
|
W |
3,840 |
|
|
|
3,840 |
|
3,250 |
|
|
|
3,250 |
|
||||||||
|
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
2,470 |
|
|
|
2,470 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
2.4 |
|
|
|
1.95 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 35 |
|
|
|
|
|
|
|||||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
Microprocessor |
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
||||||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
||||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
||||||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
||||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
Air filter |
|
|
|
|
|
|
|
Washable, long life (2,500 hr) |
|
|
|||||||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
42 / 40 / 35 |
|
|
|
|
|
|||||||||||||||
|
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
|
52 |
|
|
|
|
|
|
|||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
||||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
||||||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
||||||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
|||||||||||||||
|
outer diameter |
|
|
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
|||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
|
6.17 (2.8) - R410A |
|
|
||||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
9-7/16 (240) |
|
3023/32 (780) |
|
||||||||||||||||||
|
|
|
|
Width |
|
in. (mm) |
62-1/32 (1,575) |
|
37 (940) |
|
||||||||||||||||
|
|
|
|
Depth |
|
in. (mm) |
26-3/8 (670) |
|
13- 3/8 (340) |
|
||||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||||||||||||
|
|
|
|
Height |
|
in. (mm) |
12-15/32 (317) |
|
3431/32 (888) |
|
||||||||||||||||
|
|
|
|
Width |
|
in. (mm) |
66-1/16 (1,678) |
|
3931/32 (1,015) |
|
||||||||||||||||
|
|
|
|
Depth |
|
in. (mm) |
31-1/16 (789) |
|
16- 3/32 (409) |
|
||||||||||||||||
|
Net weight |
|
|
|
|
lbs. (kg) |
|
90 (41) |
|
|
|
|
143 (65) |
|
||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
|
104 (47) |
|
|
161 (73) |
|
||||||||||||||||
|
Shipping volume |
|
|
cu.ft. (m 3 ) |
14.8 (0.420) |
|
13.0 (0.369) |
|
||||||||||||||||||
|
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-21
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Ceiling-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
|
TH3672R |
|
|
||||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
|
CH3672R |
|
|
||||||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
||||||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
|
Heating |
|
|||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
31,200 [9,500~31,200] |
|
37,400 [8,000~37,400] |
|
|||||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
21,000 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
10.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
1100 / 930 / 750 |
|
|
|
|
|
||||||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
15.1 |
|
|
|
|
9.6 |
|
|
||||||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
208 |
|
230 |
|
|
|
208 |
|
||||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
|
VAC 187 - 253 |
|
||||||||||||||
|
Max. Running amperes* |
|
|
A |
18.2 |
|
|
|
20.1 |
|
15.6 |
|
|
|
17.3 |
|
||||||||||
|
Power input |
|
|
W |
3,840 |
|
|
|
3,840 |
|
3,250 |
|
|
|
3,250 |
|
||||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
2,470 |
|
|
|
2,470 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 35 |
|
|
|
|
|
|
|||||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|||||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
||||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
||||||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
||||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
Air filter |
|
|
|
|
|
Washable, long life (2,500 hr) |
|
|
|||||||||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
42 / 40 / 35 |
|
|
|
|
|
|||||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
|
52 |
|
|
|
|
|
|
||||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
||||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
||||||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
||||||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
|||||||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
|||||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
|
6.17 (2.8) - R410A |
|
|
||||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
|
Outdoor unit |
|
||||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
9-7/16 (240) |
|
3023/32 (780) |
|
||||||||||||||||||
|
|
|
Width |
|
in. (mm) |
62-1/32 (1,575) |
|
37 (940) |
|
|||||||||||||||||
|
|
|
Depth |
|
in. (mm) |
26-3/8 (670) |
|
13- 3/8 (340) |
|
|||||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
|
Outdoor unit |
|
||||||||||||||
|
|
|
Height |
|
in. (mm) |
12-15/32 (317) |
|
3431/32 (888) |
|
|||||||||||||||||
|
|
|
Width |
|
in. (mm) |
66-1/16 (1,678) |
|
3931/32 (1,015) |
|
|||||||||||||||||
|
|
|
Depth |
|
in. (mm) |
31-1/16 (789) |
|
16- 3/32 (409) |
|
|||||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
|
84 (38) |
|
|
|
|
143 (65) |
|
||||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
|
97 (44) |
|
|
|
|
161 (73) |
|
||||||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
14.8 (0.420) |
|
13.0 (0.369) |
|
|||||||||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-22
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Ceiling-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
|
TH4272R |
|
|
||||||||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
|
|
|
|
CH4272R |
|
|
||||||||||
|
|
POWER SOURCE |
|
|
|
230 - 208 V / 1 Phase / 60 Hz |
|
|
||||||||||||||||||
|
PERFORMANCE |
|
|
Cooling |
|
|
|
|
|
Heating |
|
|||||||||||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
39,000 [9,500~39,000] |
|
44,500 [8,000~44,500] |
|
|||||||||||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
28,800 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Moisture removal (High) |
|
|
Pints / h |
|
12.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
|
1100 / 930 / 750 |
|
|
|
|
|
||||||||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
15.6 |
|
|
|
|
10.2 |
|
|
||||||||||||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
208 |
|
230 |
|
|
|
208 |
|
||||||||||
|
Available voltage range |
|
|
V |
VAC 187 - 253 |
|
|
|
|
|
VAC 187 - 253 |
|
||||||||||||||
|
Max. Running amperes* |
|
|
A |
21.1 |
|
|
|
23.3 |
|
18.6 |
|
|
|
20.6 |
|
||||||||||
|
Power input |
|
|
W |
4,140 |
|
|
|
4,140 |
|
3,630 |
|
|
|
3,630 |
|
||||||||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
3,110 |
|
|
|
3,110 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
15 / 40 |
|
|
|
|
|
|
|||||||||||||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
Microprocessor |
|
|
|||||||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|
||||||||||
|
Fan speeds Indoor / Outdoor |
|
|
3 and Automatic control / Variable |
|
|
||||||||||||||||||||
|
Optional Wired Remote Controller |
|
|
RCS-SH80UG / RCS-TM80BG |
|
|
||||||||||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
|
/ Automatic (Vertical ) |
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
Air filter |
|
|
|
|
|
Washable, long life (2,500 hr) |
|
|
|||||||||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
|
(20A , OD26mm) |
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
Rotary(SANYO) |
|
|
|||||||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
44 / 41 / 37 |
|
|
|
|
|
|||||||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
|
|
|
|
|
53 |
|
|
|
|
|
|
||||
|
Refrigerant control |
|
|
|
|
Electronic Expansion Valve (MOV) |
|
|
||||||||||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
165 (50) |
|
|
|
|
|
|
||||||||||||||
|
Limit of tubing length at shipment |
|
ft. (m) |
|
10~100 (3~30) |
|
|
|
|
|
||||||||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
3 / 8 (6.35) |
|
|
|
|
|
|||||||||||||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
5 / 8 (15.88) |
|
|
|
|
|
|||||||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
|
|
|
|
|
|
7.94 (3.6) - R410A |
|
|
||||||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
|
Outdoor unit |
|
||||||||||||||
|
Unit dimensions |
Height |
|
in. (mm) |
9-7/16 (240) |
|
48-7/16 (1,230 ) |
|
||||||||||||||||||
|
|
|
Width |
|
in. (mm) |
62-1/32 (1,575) |
|
37 (940) |
|
|||||||||||||||||
|
|
|
Depth |
|
in. (mm) |
26-3/8 (670) |
|
13- 3/8 (340) |
|
|||||||||||||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
|
Outdoor unit |
|
||||||||||||||
|
|
|
Height |
|
in. (mm) |
12-15/32 (317) |
|
52-3/8 (1,330 ) |
|
|||||||||||||||||
|
|
|
Width |
|
in. (mm) |
66-1/16 (1,678) |
|
3931/32 (1,015) |
|
|||||||||||||||||
|
|
|
Depth |
|
in. (mm) |
31-1/16 (789) |
|
16- 3/32 (409) |
|
|||||||||||||||||
|
Net weight |
|
|
lbs. (kg) |
|
84 (38) |
|
|
|
|
220 (100) |
|
||||||||||||||
|
Shipping weight |
|
|
lbs. (kg) |
|
97 (44) |
|
|
|
|
240 (109 ) |
|
||||||||||||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
14.8 (0.420) |
|
19.5 (0.552 ) |
|
|||||||||||||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-23
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Ceiling-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
TH2672R |
|
|||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
C2672R |
|
|||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||
|
PERFORMANCE |
|
|
|
|
|
|
Cooling |
|
|||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
24,400 [9,500~24,400] |
|
|||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
|
|
|
7.7 |
|
|
||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
550 / 490 / 460 |
|
|||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
|
|
|
|
14.5 |
|
|
|||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
208 |
|
|||||
|
Available voltage range |
|
|
V |
|
|
|
VAC 187 - 253 |
|
|||||||
|
Max. Running amperes* (Without Back-up Heater) |
|
A |
15.6 |
|
|
|
|
17.3 |
|
||||||
|
Power input |
|
|
W |
2,880 |
|
|
|
|
2,880 |
|
|||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
15 / 30 |
|
|
|||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
Microprocessor |
|
|||||||
|
Low ambient control |
|
|
|
|
|
|
|
Built-in 0˚F |
|
||||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
/ Automatic (Vertical ) |
|
|||||||||
|
|
|
|
|
||||||||||||
|
Air filter |
|
|
|
Washable, long life (2,500 hr) |
|
||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
(20A , OD26mm) |
|
||||||||
|
|
|
|
|
|
|||||||||||
|
Compressor |
|
|
|
|
|
|
Rotary(SANYO) |
|
|||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
39 / 37 / 33 |
|
||||||||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
49 |
|
|
|||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
165 (50) |
|
|
||||
|
Limit of tubing length at shipment |
|
ft. (m) |
10~100 (3~30) |
|
|||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
|
|
3 / 8 (6.35) |
|
|||||
|
outer diameter |
Wide tube |
|
in. (mm) |
5 / 8 (15.88) |
|
||||||||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
4.19 (1.9) - R410A |
|
|||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||
|
Unit dimensions |
Height |
|
in. (mm) |
7-17/32 (190) |
|
3023/32 (780) |
|
||||||||
|
|
|
Width |
|
in. (mm) |
51-3/16 (1,300) |
|
37 (940) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
26-3/8 (670) |
|
|
13- 3/8 (340) |
|
||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||
|
|
|
Height |
|
in. (mm) |
9-7/16 (240) |
|
|
3431/32 (888) |
|
||||||
|
|
|
Width |
|
in. (mm) |
54-19/32 (1,387) |
|
3931/32 (1,015) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
31-1/16 (789) |
|
16- 3/32 (409) |
|
|||||||
|
Net weight |
|
|
lbs. (kg) |
57 (26) |
|
|
|
|
128 (58) |
|
|||||
|
Shipping weight |
|
|
lbs. (kg) |
68 (31) |
|
|
|
|
148 (67) |
|
|||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
8.9 (0.253) |
|
|
13.0 (0.369) |
|
||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-24
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Ceiling-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
TH3672R |
|
|||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
C3672R |
|
|||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||
|
PERFORMANCE |
|
|
|
|
|
|
Cooling |
|
|||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
31,200 [9,500~31,200] |
|
|||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
|
|
|
10.0 |
|
|
||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
1100 / 930 / 750 |
|
|||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
|
|
|
|
15.1 |
|
|
|||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
208 |
|
|||||
|
Available voltage range |
|
|
V |
|
|
|
VAC 187 - 253 |
|
|||||||
|
Max. Running amperes* |
|
|
A |
18.2 |
|
|
|
|
20.1 |
|
|||||
|
Power input |
|
|
W |
3,840 |
|
|
|
|
3,840 |
|
|||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
15 / 35 |
|
|
|||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
Microprocessor |
|
|||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
/ Automatic (Vertical ) |
|
|||||||||
|
|
|
|
|||||||||||||
|
Air filter |
|
|
|
Washable, long life (2,500 hr) |
|
||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
(20A , OD26mm) |
|
||||||||
|
|
|
|
|
|
|
||||||||||
|
Compressor |
|
|
|
|
|
|
Rotary(SANYO) |
|
|||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
|
|
|
|
42 / 40 / 35 |
|
|||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
52 |
|
|
|||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
165 (50) |
|
|
||||
|
Limit of tubing length at shipment |
|
ft. (m) |
10~100 (3~30) |
|
|||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
|
|
3 / 8 (6.35) |
|
|||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
|
|
|
|
5 / 8 (15.88) |
|
|||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
6.17 (2.8) - R410A |
|
|||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||
|
Unit dimensions |
Height |
|
in. (mm) |
9-7/16 (240) |
|
|
3023/32 (780) |
|
|||||||
|
|
|
Width |
|
in. (mm) |
62-1/32 (1,575) |
|
37 (940) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
26-3/8 (670) |
|
|
13- 3/8 (340) |
|
||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||
|
|
|
Height |
|
in. (mm) |
12-15/32 (317) |
|
3431/32 (888) |
|
|||||||
|
|
|
Width |
|
in. (mm) |
66-1/16 (1,678) |
|
3931/32 (1,015) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
31-1/16 (789) |
|
16- 3/32 (409) |
|
|||||||
|
Net weight |
|
|
lbs. (kg) |
84 (38) |
|
|
|
|
143 (65) |
|
|||||
|
Shipping weight |
|
|
lbs. (kg) |
97 (44) |
|
|
|
|
161 (73) |
|
|||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
14.8 (0.420) |
|
|
13.0 (0.369) |
|
||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-25
1
2
3
4
5
6
1
2
3
4
5
6
1-1 Unit Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
1. Specifications |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Ceiling-Mounted Type |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
MODEL No. |
|
Indoor Unit |
|
|
|
|
|
|
TH4272R |
|
|||||
|
|
|
Outdoor Unit |
|
|
|
|
|
|
C4272R |
|
|||||
|
|
POWER SOURCE |
|
230 - 208 V / 1 Phase / 60 Hz |
|
|||||||||||
|
PERFORMANCE |
|
|
|
|
|
|
Cooling |
|
|||||||
|
Capacity * [minimum~muximum] |
|
BTU / h |
39,000 [9,500~39,000] |
|
|||||||||||
|
|
|
(17˚F)** |
|
BTU / h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Moisture removal (High) |
|
|
Pints / h |
|
|
|
|
|
12.6 |
|
|
||||
|
Air circulation (H / M / L) 230 V |
|
CFM |
1100 / 930 / 750 |
|
|||||||||||
|
External Static Pressure |
|
|
in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S.E.E.R. / H.S.P.F. (Region 4) |
|
BTU / Wh |
|
|
|
|
|
15.6 |
|
|
|||||
|
ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Voltage rating |
|
|
V |
230 |
|
|
|
|
208 |
|
|||||
|
Available voltage range |
|
|
V |
|
|
|
VAC 187 - 253 |
|
|||||||
|
Max. Running amperes* |
|
|
A |
21.1 |
|
|
|
|
23.3 |
|
|||||
|
Power input |
|
|
W |
4,140 |
|
|
|
|
4,140 |
|
|||||
|
|
|
(17˚F)** |
|
W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Back-up Heater |
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Maximum overcurrent protection (Indoor/Outdoor) |
|
A |
|
|
|
|
|
15 / 40 |
|
|
|||||
|
FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
Microprocessor |
|
|||||||
|
Low ambient control |
|
|
|
|
|
|
|
|
Built-in 0˚F |
|
|||||
|
Fan speeds Indoor / Outdoor |
|
3 and Automatic control / Variable |
|
||||||||||||
|
Optional Wired Remote Controller |
|
RCS-SH80UG / RCS-TM80BG |
|
||||||||||||
|
Optional Wireless Remote Controller |
|
RCS-SH80UA. WL / RCS-BH80UA. WL |
|
||||||||||||
|
Air deflection (Horizontal / Vertical ) |
|
|
|
|
/ Automatic (Vertical ) |
|
|||||||||
|
|
|
|
|||||||||||||
|
Air filter |
|
|
|
Washable, long life (2,500 hr) |
|
||||||||||
|
Drain pump (Drain connection) |
|
|
|
|
|
(20A , OD26mm) |
|
||||||||
|
|
|
|
|
|
|
||||||||||
|
Compressor |
|
|
|
|
|
|
Rotary(SANYO) |
|
|||||||
|
Operation sound |
Indoor - Hi/Me/Lo |
|
dB - A |
|
|
|
|
|
44 / 41 / 37 |
|
|||||
|
|
|
Outdoor - Hi |
|
dB - A |
|
|
|
|
|
53 |
|
|
|||
|
Refrigerant control |
|
|
|
Electronic Expansion Valve (MOV) |
|
||||||||||
|
REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Limit of tubing length |
|
|
ft. (m) |
|
|
|
|
|
165 (50) |
|
|
||||
|
Limit of tubing length at shipment |
|
ft. (m) |
10~100 (3~30) |
|
|||||||||||
|
Limit of elevation difference |
|
ft. (m) |
Outdoor unit is higher than indoor unit : 100 (30) |
|
|||||||||||
|
between the two units |
|
|
ft. (m) |
Outdoor unit is lower than indoor unit : 50 (15) |
|
||||||||||
|
Refrigerant tube |
Narrow tube |
|
in. (mm) |
|
|
|
|
|
3 / 8 (6.35) |
|
|||||
|
outer diameter |
Wide tube |
|
in. (mm) |
|
|
|
|
|
5 / 8 (15.88) |
|
|||||
|
Refrigerant amount at shipment |
|
lbs. (kg) |
|
|
7.94 (3.6) - R410A |
|
|||||||||
|
DIMENSIONS & WEIGHT |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||
|
Unit dimensions |
Height |
|
in. (mm) |
9-7/16 (240) |
|
|
48-7/16 (1,230 ) |
|
|||||||
|
|
|
Width |
|
in. (mm) |
62-1/32 (1,575) |
|
37 (940) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
26-3/8 (670) |
|
|
13- 3/8 (340) |
|
||||||
|
Package dimensions |
|
|
|
Indoor unit |
|
|
|
|
Outdoor unit |
|
|||||
|
|
|
Height |
|
in. (mm) |
12-15/32 (317) |
|
52-3/8 (1,330 ) |
|
|||||||
|
|
|
Width |
|
in. (mm) |
66-1/16 (1,678) |
|
3931/32 (1,015) |
|
|||||||
|
|
|
Depth |
|
in. (mm) |
31-1/16 (789) |
|
16- 3/32 (409) |
|
|||||||
|
Net weight |
|
|
lbs. (kg) |
84 (38) |
|
|
|
|
220 (100) |
|
|||||
|
Shipping weight |
|
|
lbs. (kg) |
97 (44) |
|
|
|
|
240 (109 ) |
|
|||||
|
Shipping volume |
|
cu.ft. (m 3 ) |
14.8 (0.420) |
|
|
19.5 (0.552 ) |
|
||||||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148
I-26