TECHNICAL & SERVICE MANUAL
STB0810C1 STB0811C1 STB1010C1 STB1023C1 STB1020C1 STB1123C1 STB1220C1 STB0823H1
FILE NO.
Destination: U.S.A.
SANYO 26˝ THROUGH THE WALL AIR CONDITIONERS & HEAT PUMP
COOLING ONLY MODEL
Model No. |
Product Code No. |
|||
|
|
|
|
|
STB0810C1–S |
1 |
851 |
005 |
66 |
|
|
|
|
|
STB1010C1–S |
1 |
851 |
005 |
65 |
|
|
|
|
|
STB1020C1–S |
1 |
851 |
005 |
68 |
|
|
|
|
|
STB1220C1–S |
1 |
851 |
005 |
67 |
|
|
|
|
|
COOLING & ELECTRIC HEATING MODEL
Model No. |
Product Code No. |
|||
|
|
|
|
|
STB0811C1–S |
1 |
851 |
005 |
69 |
|
|
|
|
|
STB1023C1–S |
1 |
851 |
005 |
51 |
|
|
|
|
|
STB1123C1–S |
1 |
851 |
005 |
70 |
|
|
|
|
|
|
|
|
|
|
HEAT PUMP MODEL |
|
|
||
|
|
|||
Model No. |
Product Code No. |
|||
|
|
|
|
|
STB0823H1–S |
1 |
851 |
005 |
52 |
|
|
|
|
|
STB0810C1 STB0811C1
STB1010C1 STB1023C1
STB1020C1 STB1123C1
STB1220C1 STB0823H1
REFERENCE NO. SM700487
IMPORTANT!
Please Read Before Starting
This air conditioner meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.
For safe installation and trouble-free operation, you must:
•Carefully read the INSTRUCTION MANUAL and INSTALLATION INSTRUCTIONS attached to each air conditioner before beginning.
•Follow each installation or repair step exactly as shown.
•Observe all local, state, and national electrical codes.
•Pay close attention to all warning and caution notices given in this manual.
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
If Necessary, Get Help
These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.
SPECIAL PRECAUTIONS
WARNING |
When Wiring |
|
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.
•All wiring must conform to local electrical codes.
•Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
•DO NOT, under any circumstances, cut or remove the third (ground) prong from the power cord plug.
•DO NOT use an adapter Plug or extension cord.
•DO NOT use a damaged power cord, plug, or wall outlet. Replace them immediately.
•DO NOT change the internal wiring or any part of the system.
•DO NOT turn the air conditioner on and off by plugging and unplugging. Use the Operation switch.
When Transporting
Be careful when picking up and moving the air conditioner. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.
When Installing
Place of Installation
•If possible, install the unit in a shady location.
•Install it at a spot where optimum air circulation can be obtained. No chairs or other obstructions are allowed in front of the air conditioner.
•Keep enough space from any outside obstruction (wall, bush, etc.).
Dimension of |
|
|
|
|
|
|
Wall Opening |
|
|
|
261/8 |
|
|
Wall opening of |
|
|
|
|
|
|
26-1/8" x 15-3/4" |
|
|
|
|
|
|
is required |
|
|
|
|
|
153/4 |
|
|
|
|
|
|
|
Minimum Wall Sleeve Opening |
|
|||||
Be sure to use lintel |
Trim |
|
|
|
|
|
molding |
|
|
|
|
||
to support the block |
|
|
|
|
||
(if desired) |
|
|
|
|||
and brick above the |
|
|
|
|
|
|
sleeve to retain the |
|
|
|
|
|
Caulk |
weight of the unit |
|
|
|
|
|
(4sides) |
|
|
|
|
|
|
|
Room side |
157 |
/8" |
16 |
7/8" |
Outside |
|
|
|
|
|
Minimum 5" from the floor
Box and receptacle
•As a safety measure, it is recommended that two people install the unit.
•Hold the unit securely, and be careful not to drop any parts if the air conditioner is being installed on an upper floor of a multistory building.
When Servicing
•Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.
•Keep fingers and clothing away from any moving parts.
•Clean up the site after you finish, remembering to check that no metal scraps or bits of tools have been left inside the unit being serviced.
Others
CAUTION
•Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.
•Confirm upon completing installation that no refrigerant gas is leaking. If escaped gas comes in contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas.
i
HOW TO USE THIS MANUAL
This manual is designed to help service personnel to understand basic functions, operation and possible troubles and their remedies on SANYO 26˝ Through The Wall Air Conditioner. You can use this manual both as a reference to find specific information about the capacity, construction of the unit, and as a source of information to help you set up and maintain the air conditioner. Please use this manual to make your work easier, keep the air conditioner functioning well, and keep your customer satisfied.
Please read IMPORTANT ! precautional information on the previous page before you start actual work.
SANYO 26˝ THROUGH THE WALL A/C MODEL IDENTIFICATION
SANYO 26˝ Through The Wall Air Conditioner is identified by a model number. Cooling or heating capacity, electrical information and special features included on the air conditioner are indicated on the model number.
|
|
|
|
|
|
|
|
Example |
|
|
|
|
||||||||||||||||
|
|
|
|
|
STB 1 0 2 3 C 1 |
|
|
|
|
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Development Flag |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
STB : SANYO 26˝Thru the wall |
|
|
|
|
|
|
C : Cooling H : Heat Pump |
|||||||||||||||||||||
Capacity |
|
|
|
|
|
|
|
|
Electric Heater Size |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|||||||||||||||||||||
08 : |
8,000 BTU/h class |
|
|
|
|
0 |
: No Electric Heater |
|||||||||||||||||||||
10 : |
10,000 BTU/h class |
|
|
|
|
|
|
|
|
|
|
|
|
1 |
: 1.2 kW |
|||||||||||||
|
|
|
|
3 |
: 3.4 kW |
|||||||||||||||||||||||
11 : |
11,000 BTU/h class |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
Power Supply |
||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
12 : |
12,000 BTU/h class |
|||||||||||||||||||||||||||
1 |
: 60Hz 115 V |
|||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
: 60Hz 230 / 208 V |
NOTE
To identify the correct model number of your air conditioner, you must find the nameplate.
The name plate is usually located in front of electric component box (behind the grille).
First, remove the grille to access the electric component box.
ii
Table of Contents
|
|
|
|
Page |
1. |
OPERATING RANGE ............................................................................................................................... |
1 |
||
2. |
SPECIFICATIONS |
|
||
|
2-1. |
Unit Specifications .......................................................................................................................... |
2 |
|
|
2-2. |
Major Component Specifications ................................................................................................... |
4 |
|
|
2-3. |
Other Component Specifications.................................................................................................... |
6 |
|
3. |
DIMENSIONAL DATA............................................................................................................................... |
7 |
||
4. |
REFRIGERANT FLOW DIAGRAM .......................................................................................................... |
8 |
||
5. |
PERFORMANCE DATA |
|
||
|
5-1. |
Cooling Capacity ........................................................................................................................... |
9 |
|
|
5-2. |
Heating Capacity ........................................................................................................................... |
17 |
|
6. |
ELECTRICAL DATA |
|
||
|
6-1. |
Electrical Characteristics ............................................................................................................... |
18 |
|
|
6-2. |
Electrical Wiring Diagrams ............................................................................................................ |
21 |
|
|
6-3. |
P.C.B. Ass'y (Printed Pattern)........................................................................................................ |
27 |
|
7. |
TROUBLESHOOTING |
|
||
|
7-1. |
Check before and after troubleshooting ........................................................................................ |
28 |
|
|
7-2. |
Air conditioner does not operate .................................................................................................... |
29 |
|
|
7-3. |
Some part of air conditioner does not operate .............................................................................. |
31 |
|
|
7-4. |
Air conditioner operates, but abnormalities are observed ............................................................. |
33 |
|
|
7-5. |
If a sensor is defective ................................................................................................................... |
34 |
|
8. |
CHECKING ELECTRICAL COMPONENTS |
|
||
|
8-1. |
Measurement of Insulation Resistance .......................................................................................... |
35 |
|
|
8-2. |
Checking Motor Capacitor .............................................................................................................. |
36 |
|
|
8-3. |
Checking Fan Motor Winding ......................................................................................................... |
36 |
|
|
8-4. |
Checking Compressor Motor Winding............................................................................................ |
36 |
|
|
8-5. |
Checking Thermistor ...................................................................................................................... |
36 |
|
9. |
DISASSEMBLY PROCEDURE |
|
||
|
9-1. |
Removing Front Grille..................................................................................................................... |
37 |
|
|
9-2. |
Removing Wall Sleeve ................................................................................................................... |
37 |
|
|
9-3. |
Removing Electrical Component Box ............................................................................................. |
37 |
|
|
9-4. |
Removing Electric Heater............................................................................................................... |
38 |
|
|
9-5. |
Removing Blower Wheel ................................................................................................................ |
39 |
|
|
9-6. |
Removing Evaporator..................................................................................................................... |
39 |
|
|
9-7. |
Removing Condenser..................................................................................................................... |
40 |
|
|
9-8. |
Removing Propeller Fan................................................................................................................. |
40 |
|
|
9-9. |
Removing Fan Motor ...................................................................................................................... |
41 |
|
10.FUNCTION |
|
|||
|
10-1. |
Room temperature Control ............................................................................................................ |
42 |
|
|
10-2. |
Defrosting Operation (Heating)....................................................................................................... |
45 |
|
|
|
|
||
APPENDIX |
.................................................................................................................................................. |
46 |
iii
1. OPERATING RANGE
■ COOLING ONLY MODEL
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1
|
Temperature |
Indoor Air Intake Temp. |
Outdoor Air Intake Temp. |
|
|
|
|
|
|
Cooling |
Maximum |
95°F D.B. / 71°F W.B. |
115°F D.B. |
|
|
|
|
||
Minimum |
67°F D.B. / 57°F W.B. |
67°F D.B. |
||
|
||||
|
|
|
|
■ COOLING & ELECTRIC HEATING MODEL
Models STB0811C1 STB1023C1 STB1123C1
|
Temperature |
Indoor Air Intake Temp. |
Outdoor Air Intake Temp. |
|||
|
|
|
|
|
|
|
Cooling |
Maximum |
95°F D.B. / 71°F W.B. |
115°F D.B. |
|||
|
|
|
|
|
||
Minimum |
67°F D.B. / 57°F W.B. |
67°F D.B. |
||||
|
||||||
|
|
|
|
|
|
|
Heating |
Maximum |
80°F D.B. / 67°F W.B. |
|
|
|
|
|
|
|
||||
|
|
|
|
|
||
Minimum |
— D.B. / — W.B. |
|
|
|
||
|
|
|
|
|||
|
|
|
|
|||
|
|
|
|
|
|
■ HEAT PUMP MODEL |
|
|
||
Model |
STB0823H1 |
|
|
|
|
|
|
|
|
|
Temperature |
Indoor Air Intake Temp. |
Outdoor Air Intake Temp. |
|
|
|
|
|
|
Cooling |
Maximum |
95°F D.B. / 71°F W.B. |
115°F D.B. |
|
|
|
|
||
Minimum |
67°F D.B. / 57°F W.B. |
67°F D.B. |
||
|
||||
|
|
|
|
|
Heating |
Maximum |
80°F D.B. / 67°F W.B. |
75°F D.B. / 65°F W.B. |
|
|
|
|
||
Minimum |
— D.B. / — W.B. |
17°F D.B. / 15°F W.B. |
||
|
||||
|
|
|
|
1
2. SPECIFICATIONS
2-1. Unit Specifications
Models STB0810C1 STB1010C1 STB1020C1 |
STB1220C1 |
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model Number |
|
|
|
|
|
STB0810C1 |
|
STB1010C1 |
|
|
STB1020C1 |
STB1220C1 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Voltage (V) |
|
|
|
|
|
115 |
|
115 |
|
|
|
230 / 208 |
230 / 208 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Performance |
|
|
|
|
|
|
|
COOLING |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Cooling Capacity |
|
|
|
|
BTU/h |
8,200 |
|
10,200 |
|
|
|
9,700 / 9,500 |
11,500 / 11,300 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Air Flow....Hi |
|
|
CFM (CMM) |
270 (7.65) |
|
270 (7.65) |
|
|
|
270 (7.65) |
270 (7.65) |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Dihumidification |
|
|
|
Pints/h |
2.0 |
|
2.7 |
|
|
|
2.6 |
3.2 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Electrical Rating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
Available voltage range |
|
|
|
V |
104 ~ 126 |
|
|
|
|
|
253 ~ 187 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Cooling |
Amperes |
|
|
|
A |
8.3 |
|
10.6 |
|
|
|
5.0 / 5.3 |
6.1 / 6.6 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Watts |
|
|
|
W |
940 |
|
1,200 |
|
|
|
1,140 |
/ 1,110 |
1,350 / 1,330 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
Power factor |
|
|
% |
98 |
|
98 |
|
|
|
99 / 100 |
96 / 97 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
EER |
|
|
BTU/hW |
8.7 |
|
8.5 |
|
|
|
8.5 / 8.5 |
8.5 / 8.5 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Starting amperes |
|
|
|
|
A |
43 |
|
53 |
|
|
|
30 |
34 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Recommeded Circuit Protection |
|
|
|
A |
15 |
|
15 |
|
|
|
|
|
15 |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Plug Type |
|
|
|
|
|
Parallel |
|
Parallel |
|
|
Tandem |
Tandem |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
Controls / Temperature control |
|
|
|
|
|
|
Mechanical / Thermostat |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Timer |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fan speeds |
|
|
|
|
|
2 |
|
2 |
|
|
|
|
|
2 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Airflow direction (Indoor) |
|
Horizontal |
|
|
Manual |
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
Vertical |
|
|
Manual |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Air filter |
|
|
|
|
|
|
|
Washable |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Air exhaust |
|
|
|
|
|
|
|
|
|
Yes |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Compressor |
|
|
|
|
|
|
|
Rotary (Hermetic) |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
R22-Amount charged at shipment |
|
|
OZ |
20.1 |
|
28.2 |
|
|
|
23.3 |
28.2 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Refrigerant control |
|
|
|
|
|
|
|
Capillary tube |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Operation sound |
Indoor : Hi / Lo |
|
|
dB-A |
57 / 55 |
|
60 / 57 |
|
|
|
60 |
/ 57 |
60 / 57 |
|||
|
|
|
Outdoor : Hi / Lo |
|
|
dB-A |
63 / 60 |
|
68 / 64 |
|
|
|
68 / 64 |
68 / 64 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dimensions & Weight |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Unit dimensions |
Height |
|
|
|
In |
|
15-3/4 |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
(Refer to page 7) |
Width |
|
|
|
In |
|
25-15/16 |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
Depth |
|
|
|
In |
|
21-1/2 |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Package dimensions |
Height |
|
|
|
In |
|
18-5/16 |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
Width |
|
|
|
In |
|
29-1/8 |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
Depth |
|
|
|
In |
|
24-11/16 |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Weight |
Net |
|
|
|
lbs |
82 |
|
90 |
|
|
|
|
|
89 |
93 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Shipping |
|
|
|
lbs |
93 |
|
101 |
|
|
|
100 |
104 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Shipping volume |
|
|
|
|
Cuft |
|
7.62 |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
||||||||||
|
Remarks: Rating conditions are: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Cooling : Indoor air temperature |
80°F D.B. / |
67°F W.B. Heating : |
Indoor air temperature |
70°F D.B. |
|||||||||||||
|
|
Outdoor air temperature |
95°F D.B. / |
75°F W.B. |
Outdoor air temperature |
47°F D.B. / 43°F W.B. |
||||||||||||
|
|
Parallele |
|
Tandem |
|
Perpendicular |
|
|
|
|
|
|
|
|||||
|
|
|
230/208V |
|
230/208V |
|
|
|
|
|
|
|
||||||
|
|
115V |
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
15AMP |
|
20AMP |
|
|
|
|
|
|
|
||||||
|
|
15AMP |
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wall Receptacles |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
Wall Sleeve Dimension |
|
2
Models STB0811C1 STB1023C1 STB1123C1 |
STB0823H1 |
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model Number |
|
|
|
STB0811C1 |
|
STB1023C1 |
|
STB1123C1 |
STB0823H1 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage (V) |
|
|
|
115 |
|
230 / 208 |
|
230 / 208 |
230 / 208 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Performance |
|
|
|
COOLING & ELECTRIC HEATING |
HEAT PUMP |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cooling Capacity |
|
|
BTU/h |
8,000 |
|
9,500 / 9,300 |
11,300 / 11,000 |
8,000 / 7,800 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Heat pump Capacity |
|
|
BTU/h |
— |
|
— |
|
— |
7,500 / 7,400 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Electric Heating Capacity |
|
BTU/h |
4,040 |
|
11,250 / 9,200 |
11,250 / 9,200 |
11,250 / 9,200 |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Air Flow....Hi |
|
CFM (CMM) |
250 (7.08) |
|
250 (7.08) |
|
250 (7.08) |
250 (7.08) |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dihumidification |
|
|
Pints/h |
2.0 |
|
2.6 |
|
3.2 |
2.0 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Electrical Rating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Available voltage range |
|
V |
104 ~ 126 |
|
|
|
|
|
253 ~ 187 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cooling |
Amperes |
|
A |
8.3 |
|
5.0 / 5.3 |
|
6.0 / 6.5 |
4.2 / 4.5 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Watts |
|
W |
920 |
|
1,120 / 1,090 |
1,330 / 1,310 |
940 / 920 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power factor |
% |
96 |
|
97 / 99 |
|
96 / 97 |
97 / 98 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EER |
|
BTU/hW |
8.7 |
|
8.5 / 8.5 |
|
8.5 / 8.5 |
8.5 / 8.5 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Starting amperes |
|
|
A |
43 |
|
30 |
|
34 |
25 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Heat pump |
Amperes |
|
A |
— |
|
— |
|
— |
4.0 / 4.3 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Watts |
|
W |
— |
|
— |
|
— |
880 / 870 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
COP |
|
W / W |
— |
|
— |
|
— |
2.5 / 2.5 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Electric Heater |
Amperes |
|
A |
12.0 |
|
15.5 / 14.2 |
|
15.5 / 14.2 |
15.5 / 14.2 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Watts |
|
W |
1,350 |
|
3,550 |
/ |
2,930 |
3,550 |
/ |
2,930 |
3,550 / 2,930 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Element |
|
kW |
1.22 |
|
3.4 |
|
3.4 |
3.4 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Recommeded Circuit Protection |
|
A |
15 |
|
20 |
|
20 |
20 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Plug Type |
|
|
|
Parallel |
|
|
|
|
|
Perpendicular |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Controls / Temperature control |
|
|
|
|
Mechanical / Thermostat |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Timer |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fan speeds |
|
|
|
2 |
|
2 |
|
2 |
2 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Airflow direction (Indoor) |
Horizontal |
|
|
|
|
Manual |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Vertical |
|
|
|
|
Manual |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Air filter |
|
|
|
|
|
|
|
Washable |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Air exhaust |
|
|
|
|
|
|
|
|
Yes |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Compressor |
|
|
|
|
|
|
Rotary (Hermetic) |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R22-Amount charged at shipment |
|
OZ |
20.1 |
|
23.3 |
|
27.2 |
28.2 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Refrigerant control |
|
|
|
|
|
Capillary tube |
3 |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operation sound |
Indoor : Hi / Lo |
|
dB-A |
57 / 55 |
|
60 / 56 |
|
60 / 56 |
57 / 55 |
|||||
|
|
|
Outdoor : Hi / Lo |
|
dB-A |
64 / 61 |
|
68 / 62 |
|
68 / 62 |
64 / 61 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dimensions & Weight |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Unit dimensions |
Height |
|
In |
|
|
15-3/4 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(Refer to page 7) |
Width |
|
In |
|
|
25-15/16 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Depth |
|
In |
|
|
21-1/2 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Package dimensions |
Height |
|
In |
|
|
18-5/16 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Width |
|
In |
|
|
29-1/8 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Depth |
|
In |
|
|
24-11/16 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Weight |
Net |
|
lbs |
82 |
|
89 |
|
95 |
90 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Shipping |
|
lbs |
93 |
|
100 |
|
106 |
101 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Shipping volume |
|
|
Cuft |
|
|
7.62 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
3
2-2. Major Component Specifications
Models STB0810C1 |
STB1010C1 |
STB1020C1 |
STB1220C1 |
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model Number |
|
|
|
|
|
STB0810C1 |
|
STB1010C1 |
|
STB1020C1 |
|
STB1220C1 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controller PCB |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Part No. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control circuit fuse |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type |
|
|
|
|
|
Rotary (Hermetic) |
|
Rotary (Hermetic) |
|
Rotary (Hermetic) |
|
Rotary (Hermetic) |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Compressor model |
|
|
|
|
C-1R62H2D |
|
C-R80H2C |
|
C-R76H6K |
|
C-R95H6C |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
( Parts code No. ) |
|
( 80663842-S ) |
|
( 80680342-S ) |
|
( 80677946-S ) |
|
( 80695246-S ) |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Source |
|
|
|
|
|
115V 1-phase 60Hz |
|
115V 1-phase 60Hz |
|
230-208V 1-phase 60Hz |
|
230-208V 1-phase 60Hz |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nominal output |
|
|
|
|
W |
625 |
|
800 |
|
|
750 |
|
950 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Compressor oil ... Amount |
|
|
|
cc |
SUNISO 4GSD-T....350 |
|
SUNISO 4GSD-T....350 |
|
SUNISO 4GSD-T....350 |
|
SUNISO 4GSD-T....450 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Coil resistance (at 77°F) |
|
|
|
Ω |
C-R: 1.010 |
|
C-R: 0.639 |
|
|
C-R: 2.288 |
|
C-R: 1.886 |
|||
|
|
|
|
|
|
|
|
|
C-S: 5.996 |
|
C-S: 2.410 |
|
|
C-S: 5.385 |
|
C-S: 0.639 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Safety device |
Type |
|
|
|
|
External protector |
|
External protector |
|
External protector |
|
External protector |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Overload relay |
|
MRA98869-9200 |
|
MRA98748-9200 |
|
MRA98735-9201 |
|
MRA99038-9201 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating temp. Open |
°F |
293±9 |
|
302±9 |
|
|
311±9 |
|
293±9 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Close |
°F |
156±20 |
|
156±20 |
|
|
156±20 |
|
156±20 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating amp.(at 77 °F) |
|
Trip in 6 to sec.at 30.5A |
|
Trip in 6 to 16 sec. at 40A |
|
Trip in 6 to 16 sec. at 24A |
|
Trip in 6 to 16 sec. at 24A |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Run capacitor |
|
|
|
|
µF |
25 |
|
35 |
|
|
20 |
|
22.5 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VAC |
400 |
|
400 |
|
|
400 |
|
400 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Fan & Fan Motor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
Fan Type |
Indoor (Dia. / Depth) |
In |
|
|
Centrifigal |
(Dia 7-3/32 : Depth 3-17/32) |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
Outdoor (Dia. / Depth) |
In |
|
|
Puropeller |
(Dia 12-19/32 : Depth 3-3/8) |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
Fan motor model ... Q'ty |
|
|
|
|
KFC6S-91A1P...1 |
|
|
|
KFC6S-91A6P...1 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
Source |
|
|
|
|
|
115V 1-phase 60Hz |
|
|
|
230-208V 1-phase 60Hz |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
No. of poles ... rpm, High |
(V) |
|
6...1,110(115V) |
|
|
|
6...1,080(208V) |
1,100(230V) |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Nominal output |
|
|
|
|
W |
|
90 |
|
|
90 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
Coil resistance (at 68°F) |
|
|
|
Ω |
BLU-BLN: 16.59 |
|
|
|
WHT-BLN: 60.10 |
||||||
|
|
|
|
|
|
|
|
|
BLU-YEL: 7.84 |
|
|
|
WHT-BLN: 33.46 |
||||
|
|
|
|
|
|
|
|
|
BLU-PNK: 17.19 |
|
|
|
WHT-PNK: 59.31 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
Safety device |
Type |
|
|
|
|
Thermal protector |
|
|
|
Thermal protector |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
Operating temp. Open |
°F |
248±9 |
|
|
248±9 |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
Close |
°F |
171±27 |
|
|
171±27 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Run capacitor |
|
|
|
|
µF |
|
16 |
|
|
4 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
VAC |
|
220 |
|
|
440 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Heat Exch. Coil |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
Evaporator |
Coil |
|
|
|
|
|
|
Aluminum plate fin / Copper tube |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
Rows |
|
|
|
|
2 |
|
2 |
|
|
2 |
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
Fins per inch |
|
19.5 |
|
19.5 |
|
|
19.5 |
|
15.9 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Face area |
|
|
|
ft2 |
1.049 |
|
1.049 |
|
|
1.049 |
|
1.049 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Condenser |
Coil |
|
|
|
|
|
|
Aluminum plate fin / Copper tube |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
Rows |
|
|
|
|
2 |
|
3 |
|
|
3 |
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
Fins per inch |
|
18.1 |
|
14.1 |
|
|
14.1 |
|
18.1 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Face area |
|
|
|
ft2 |
1.075 |
|
1.075 |
|
|
1.075 |
|
1.075 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
4
Models STB0811C1 |
STB1023C1 |
STB1123C1 |
STB0823H1 |
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model Number |
|
|
|
|
|
STB0811C1 |
|
STB1023C1 |
STB1123C1 |
|
STB0823H1 |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controller PCB |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Part No. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
851-0-5171-660-00 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
POW-STBH |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control circuit fuse |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Compressor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Type |
|
|
|
|
|
Rotary (Hermetic) |
|
Rotary (Hermetic) |
Rotary (Hermetic) |
|
Rotary (Hermetic) |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Compressor model |
|
|
|
|
C-1R62H2D |
|
C-R76H6K |
C-R95H6C |
|
C-1R65H6W |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
( Parts code No. ) |
|
( 80663842-s) |
|
( 80677946-S ) |
( 80695246-S ) |
|
( 80665146-S ) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Source |
|
|
|
|
|
115V 1-phase 60Hz |
|
230-208V 1-phase 60Hz |
230-208V 1-phase 60Hz |
|
230-208V 1-phase 60Hz |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Nominal output |
|
|
|
W |
625 |
|
|
750 |
|
950 |
|
|
650 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Compressor oil ... Amount |
|
|
|
cc |
SUNISO 4GSD-T....350 |
|
SUNISO 4GSD-T....350 |
SUNISO 4GSD-T....450 |
|
SUNISO 4GSD-T....350 |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Coil resistance (at 77°F) |
|
|
|
Ω |
|
C-R: 1.010 |
|
|
C-R: 2.288 |
|
C-R: 1.886 |
|
|
C-R: 3.311 |
||||||
|
|
|
|
|
|
|
|
|
|
C-S: 5.996 |
|
|
C-S: 5.385 |
|
C-S: 0.639 |
|
|
C-S: 3.529 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Safety devices Type |
|
|
|
|
External protector |
|
External protector |
External protector |
|
External protector |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
Overload relay |
|
MRA98869-9200 |
|
MRA98735-9201 |
MRA99038-9201 |
|
MRA99082-9201 |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating temp. Open |
°F |
293±9 |
|
|
311±9 |
|
293±9 |
|
|
293±9 |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Close |
°F |
156±20 |
|
|
156±20 |
|
156±20 |
|
|
156±20 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
Operating amp.(at 77 °F) |
|
Trip in 6 to sec.at 30.5A |
|
Trip in 6 to 16 sec. at 24A |
Trip in 6 to 16 sec. at 24A |
|
Trip in 6 to 16 sec. at 16.5A |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Run capacitor |
|
|
|
|
µF |
25 |
|
|
20 |
|
22.5 |
|
|
22.5 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VAC |
400 |
|
|
400 |
|
400 |
|
|
400 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Fan & Fan Motor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
Fan Type |
Indoor (Dia. / Depth) |
In |
|
|
|
|
Centrifigal |
(Dia 7-3/32 : Depth 3-17/32) |
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
Outdoor (Dia. / Depth) |
In |
|
|
|
|
Puropeller |
(Dia 12-19/32 : Depth 3-3/8) |
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Fan motor model ... Q'ty |
|
|
|
|
KFC6S-91A1P...1 |
|
|
|
|
KFC6S-91A6P...1 |
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Source |
|
|
|
|
|
115V 1-phase 60Hz |
|
|
|
|
230-208V 1-phase 60Hz |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
No. of poles ... rpm, High |
(V) |
|
6...1,110(115V) |
|
|
|
6...1,080(208V) 1,100(230V) |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Nominal output |
|
|
|
W |
90 |
|
|
|
|
|
90 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Coil resistance (at 68°F) |
|
|
|
Ω |
BLU-BLN: 16.59 |
|
|
|
|
WHT-BLN: 60.10 |
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
BLU-YEL: 7.84 |
|
|
|
|
WHT-BLN: 33.46 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
BLU-PNK: 17.19 |
|
|
|
|
WHT-PNK: 59.31 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Safety device |
Type |
|
|
|
|
Thermal protector |
|
|
|
|
Thermal protector |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
Operating temp. Open |
°F |
248±9 |
|
|
|
|
|
248±9 |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Close |
°F |
171±27 |
|
|
|
|
|
171±27 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Run capacitor |
|
|
|
|
µF |
16 |
|
|
|
|
|
4 |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
VAC |
220 |
|
|
|
|
|
440 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Heat Exch. Coil |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
Evaporator |
Coil |
|
|
|
|
|
|
|
|
|
Aluminum plate fin / Copper tube |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rows |
|
|
|
|
2 |
|
|
2 |
|
3 |
|
|
3 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
Fins per inch |
|
19.5 |
|
|
19.5 |
|
15.9 |
|
|
14.1 |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Face area |
|
|
|
ft2 |
1.049 |
|
|
1.049 |
|
1.049 |
|
|
1.049 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Condenser |
Coil |
|
|
|
|
|
|
|
|
|
Aluminum plate fin / Copper tube |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rows |
|
|
|
|
2 |
|
|
3 |
|
3 |
|
|
3 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
Fins per inch |
|
18.1 |
|
|
14.1 |
|
18.1 |
|
|
14.1 |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Face area |
|
|
|
ft2 |
1.075 |
|
|
1.075 |
|
1.075 |
|
|
1.075 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
5
2-3. Other Component Specifications
Models STB0810C1 |
STB1010C1 |
STB1020C1 |
STB1220C1 |
|
|
|
|
|
||||||
|
|
STB0811C1 |
STB1023C1 |
STB1123C1 |
STB0823H1 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Room Thermostat |
|
|
|
|
|
YTB-2U136 |
|
|
|
YTB-2U358 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Model |
|
|
|
|
|
STB1020C1 |
STB0810C1 |
|
STB0811C1 |
STB1023C1 |
||
|
|
|
|
|
|
|
|
STB1220C1 |
STB1010C1 |
|
|
STB1123C1 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Openrating temp. |
|
|
Cold |
°F |
|
|
ON: 65 |
/ |
OFF: 61±3 (Diff: 4 Deg) |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Warm |
°F |
|
|
ON: 90 |
/ |
OFF:86 |
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
||||||
|
PTC Thermister (for compressor start up) |
|
|
|
PTH491A04AR470N500 |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Model |
|
|
|
|
|
|
STB0810C1 |
STB0811C1 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Resistance |
|
|
at 77°F |
Ω |
|
|
|
|
47±30% |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Relay (Heater) |
|
|
|
|
|
VC20A-115-S |
|
|
|
VC20A-230-S |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
|
|
|
|
|
STB0811C1 |
|
|
|
STB1023C1 |
STB1123C1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Coil rating |
|
|
|
|
|
AC115V , 60Hz |
|
|
|
AC208/230V , 60Hz |
||
|
|
Contact rating |
|
|
|
|
|
AC265V , 22A |
|
|
|
AC265V , 22A |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Electoric Heater Ass'y |
|
|
|
|
|
AH-H06S |
|
|
|
AH-H10S |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
|
|
|
|
|
STB0811C1 |
|
|
|
STB1023C1 |
STB0823H1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
STB1123C1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Heater Element |
|
Rating |
|
|
|
1.22 kW , 115V |
|
|
|
3.4 kW , 230V |
||
|
|
|
|
Resistance |
|
Ω |
|
9.5±1.5% (at 68°F) |
|
|
|
13.6±1.5% (at 68°F) |
||
|
|
|
|
Watt Dinsty |
|
w/in2 |
|
8.9 |
|
|
|
13.2 |
||
|
|
|
|
Dimension |
|
In |
|
Dia 3/8 , Leng 36 |
|
|
|
Dia 3/8 , Leng 36 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Heater Thermo. |
|
Type |
|
|
|
|
|
|
CS-7L |
|
||
|
|
|
|
Openrating temp |
°F |
|
|
OFF : 122±5 / ON : 95±9 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Fuse |
|
Type |
|
|
|
|
|
|
SF-152U |
|
||
|
|
|
|
Openrating temp |
°F |
|
|
|
|
306±5 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Power Trnsformer |
|
|
|
|
|
|
|
|
ATR-J64ULN2 |
|
|||
|
|
Model |
|
|
|
|
|
|
|
|
STB0823H1 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Rating |
|
Primary |
|
|
|
|
|
|
AC220V , 60Hz |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
Secondary |
|
|
|
|
|
|
AC19V , 0.3A |
|
||
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|||||
|
Thermister (Room sensor) |
|
|
|
|
|
|
PBC-41E-S29 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Model |
|
|
|
|
|
|
|
|
STB0823H1 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Resistance |
|
|
at 32°F |
kΩ |
|
|
|
|
15±5% |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Thermister (Outdoor coil) |
|
|
|
|
|
|
|
|
PBC-41E-S14 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Model |
|
|
|
|
|
|
|
|
STB0823H1 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Resistance |
|
|
at 32°F |
kΩ |
|
|
|
|
15±5% |
|
||
|
|
|
|
|
|
|||||||||
|
4-way Valve (Solenoid coil) |
|
|
|
CHV-01AQ503UA1(Coil) / CHV-01U1(Valve) |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Model |
|
|
|
|
|
|
|
|
STB0823H1 |
|
||
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
Coil raiting |
|
|
|
|
|
|
AC208/230V (60Hz) , 6W |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6
3. DIMENSIONAL DATA
Models STB0810C1 |
STB1010C1 |
STB1020C1 |
STB1220C1 |
|||||||||||
|
|
STB0811C1 |
STB1023C1 |
STB1123C1 |
STB0823H1 |
|||||||||
|
■ Unit Dimension |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Topview
25 -15/16" 21 -1/2"
3 " 15 - /4
Frontview |
Sideview |
Unit : inch
■ Wall Sleeve Dimension |
■ Dimension of Wall Opening |
26 -1/8"
15 -5/8"
16 -7/8"
26"
Minimum Wall
Sleeve Opening
Wall opening of 26-1/8˝ x 15-3/4˝ is required
15 -3/4"
Unit : inch
7
4. REFRIGERANT FLOW DIAGRAM
Models |
STB0810C1 |
STB1010C1 |
STB1020C1 |
STB1220C1 |
|
STB0811C1 |
STB1023C1 |
STB1123C1 |
|
|
|
|
|
Compressor |
|
|
|
Accumulator |
|
|
|
|
Evaporator |
Condenser |
|
|
|
Capillary |
|
|
|
|
tube |
|
Model |
STB0823H1 |
|
|
|
|
|
Accumulator |
Compressor |
|
|
|
|
|
|
|
|
4-way |
|
|
|
|
valve |
|
|
Indoor heat |
exchanger |
Outdoor heat |
exchanger |
|
|
|
Capillary |
|
|
|
Capillary |
tube |
|
|
|
|
|
|
|
|
tube |
|
|
|
|
|
Check |
|
|
|
|
valve |
|
|
|
|
8 |
|
|
Cooling cycle
Heating cycle
5. PERFORMANCE DATA
5-1. Cooling Capacity
Model |
|
STB0810C1 |
|
|
|
|
|
|
|
|
|
|
|
|
115 V Single phase 60 Hz |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RATING CAPACITY |
|
8,200 BTU/h |
|
|
|
|
|
||||
|
|
AIR FLOW RATE |
|
270 CFM |
|
|
|
|
|
||||
|
|
EVAPORATOR |
|
|
|
|
|
CONDENSER |
|
|
|||
|
|
ENT. TEMP. °F (°C) |
|
|
|
OUTDOOR AMBIENT TEMP. °F( °C) |
|
|
|||||
|
|
W.B. |
D.B. |
|
|
67 |
75 |
85 |
95 |
|
105 |
110 |
|
|
|
|
|
|
|
|
(19.4) |
(23.9) |
(29.4) |
(35.0) |
|
(40.6) |
(43.3) |
|
|
|
|
|
|
TC |
8,260 |
7,900 |
7,540 |
7,180 |
|
6,750 |
6,210 |
|
|
|
|
|
|
CM |
0.60 |
0.65 |
0.70 |
0.75 |
|
0.79 |
0.84 |
|
|
|
70 |
(21.1) |
|
SHC |
6,260 |
6,100 |
5,940 |
5,780 |
|
5,580 |
5,350 |
|
|
59 |
73 |
(22.8) |
|
SHC |
7,310 |
7,150 |
6,990 |
6,830 |
|
6,630 |
6,210 |
|
|
(15.0) |
77 |
(25.0) |
|
SHC |
8,260 |
7,900 |
7,540 |
7,180 |
|
6,750 |
6,210 |
|
|
|
80 |
(26.7) |
|
SHC |
8,260 |
7,900 |
7,540 |
7,180 |
|
6,750 |
6,210 |
|
|
|
84 |
(28.9) |
|
SHC |
8,260 |
7,900 |
7,540 |
7,180 |
|
6,750 |
6,210 |
|
|
|
88 |
(31.1) |
|
SHC |
8,260 |
7,900 |
7,540 |
7,180 |
|
6,750 |
6,210 |
|
|
|
|
|
|
TC |
9,350 |
8,480 |
8,090 |
7,710 |
|
7,250 |
6,670 |
|
|
|
|
|
|
CM |
0.62 |
0.67 |
0.72 |
0.77 |
|
0.81 |
0.86 |
|
|
|
70 |
(21.1) |
|
SHC |
5,170 |
5,010 |
4,840 |
4,680 |
|
4,490 |
4,260 |
|
|
63 |
73 |
(22.8) |
|
SHC |
6,220 |
6,060 |
5,890 |
5,730 |
|
5,540 |
5,310 |
|
|
(17.2) |
77 |
(25.0) |
|
SHC |
7,270 |
7,110 |
6,940 |
6,780 |
|
6,590 |
6,360 |
|
|
|
80 |
(26.7) |
|
SHC |
8,320 |
8,160 |
7,990 |
7,710 |
|
7,250 |
6,670 |
|
|
|
84 |
(28.9) |
|
SHC |
8,860 |
8,480 |
8,090 |
7,710 |
|
7,250 |
6,670 |
|
|
|
88 |
(31.1) |
|
SHC |
8,860 |
8,480 |
8,090 |
7,710 |
|
7,250 |
6,670 |
|
|
|
|
|
|
TC |
9,430 |
9,020 |
8,610 |
# 8,200 |
|
7,710 |
7,090 |
|
|
|
|
|
|
CM |
0.64 |
0.69 |
0.74 |
0.79 |
|
0.84 |
0.89 |
|
|
|
70 |
(21.1) |
|
SHC |
4,050 |
3,890 |
3,730 |
3,570 |
|
3,380 |
3,150 |
|
|
67 |
73 |
(22.8) |
|
SHC |
5,100 |
4,940 |
4,780 |
4,620 |
|
4,430 |
4,200 |
|
|
(19.4) |
77 |
(25.0) |
|
SHC |
6,150 |
5,990 |
5,830 |
5,670 |
|
5,480 |
5,250 |
|
|
|
80 |
(26.7) |
|
SHC |
7,200 |
7,040 |
6,870 |
6,720 |
|
6,530 |
6,290 |
|
|
|
84 |
(28.9) |
|
SHC |
8,250 |
8,090 |
7,920 |
7,770 |
|
7,580 |
7,090 |
|
|
|
88 |
(31.1) |
|
SHC |
9,300 |
9,020 |
8,610 |
8,200 |
|
7,710 |
7,090 |
|
|
|
|
|
|
TC |
10,000 |
9,560 |
9,130 |
8,690 |
|
8,170 |
7,520 |
|
|
|
|
|
|
CM |
0.66 |
0.71 |
0.76 |
0.82 |
|
0.86 |
0.91 |
|
|
|
73 |
(22.8) |
|
SHC |
3,970 |
3,820 |
3,660 |
3,500 |
|
3,320 |
3,090 |
|
|
70 |
77 |
(25.0) |
|
SHC |
5,020 |
4,860 |
4,710 |
4,550 |
|
4,370 |
4,140 |
|
|
(21.1) |
80 |
(26.7) |
|
SHC |
6,070 |
5,910 |
5,760 |
5,600 |
|
5,420 |
5,190 |
|
|
|
84 |
(28.9) |
|
SHC |
7,120 |
6,960 |
6,810 |
6,650 |
|
6,470 |
6,240 |
|
|
|
88 |
(31.1) |
|
SHC |
8,170 |
8,010 |
7,860 |
7,700 |
|
7,520 |
7,290 |
|
|
|
|
|
|
TC |
10,610 |
10,150 |
9,670 |
9,130 |
|
8,540 |
7,950 |
|
|
|
|
|
|
CM |
0.67 |
0.73 |
0.78 |
0.84 |
|
0.89 |
0.94 |
|
|
73 |
77 |
(25.0) |
|
SHC |
3,850 |
3,690 |
3,530 |
3,360 |
|
3,170 |
2,970 |
|
|
(22.8) |
80 |
(26.7) |
|
SHC |
4,900 |
4,740 |
4,580 |
4,400 |
|
4,220 |
4,020 |
|
|
|
84 |
(28.9) |
|
SHC |
5,950 |
5,790 |
5,630 |
5,450 |
|
5,260 |
5,070 |
|
|
|
88 |
(31.1) |
|
SHC |
7,000 |
6,840 |
6,680 |
6,500 |
|
6,310 |
6,120 |
TC : Total Cooling Capacity (BTU/h)
SHC : Sensible Heat Capacity (BTU/h)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 95°F (35°C) D.B.
Indoor Air Intake Temp. 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
9
Model |
|
STB1010C1 |
|
|
|
|
|
|
|
|
|
|
|
|
115 V Single phase 60 Hz |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RATING CAPACITY |
|
10,200 BTU/h |
|
|
|
|
|
||||
|
|
AIR FLOW RATE |
|
270 CFM |
|
|
|
|
|
||||
|
|
EVAPORATOR |
|
|
|
|
|
CONDENSER |
|
|
|||
|
|
ENT. TEMP. °F (°C) |
|
|
|
OUTDOOR AMBIENT TEMP. °F( °C) |
|
|
|||||
|
|
W.B. |
D.B. |
|
|
67 |
75 |
85 |
95 |
|
105 |
110 |
|
|
|
|
|
|
|
|
(19.4) |
(23.9) |
(29.4) |
(35.0) |
|
(40.6) |
(43.3) |
|
|
|
|
|
|
TC |
10,280 |
9,830 |
9,380 |
8,940 |
|
8,390 |
7,730 |
|
|
|
|
|
|
CM |
0.80 |
0.87 |
0.93 |
1.00 |
|
1.06 |
1.13 |
|
|
|
70 |
(21.1) |
|
SHC |
7,220 |
7,000 |
6,790 |
6,580 |
|
6,320 |
6,020 |
|
|
59 |
73 |
(22.8) |
|
SHC |
8,270 |
8,050 |
7,840 |
7,630 |
|
7,370 |
7,070 |
|
|
(15.0) |
77 |
(25.0) |
|
SHC |
9,320 |
9,100 |
8,890 |
8,680 |
|
8,390 |
7,730 |
|
|
|
80 |
(26.7) |
|
SHC |
10,280 |
9,830 |
9,380 |
8,940 |
|
8,390 |
7,730 |
|
|
|
84 |
(28.9) |
|
SHC |
10,280 |
9,830 |
9,380 |
8,940 |
|
8,390 |
7,730 |
|
|
|
88 |
(31.1) |
|
SHC |
10,280 |
9,830 |
9,380 |
8,940 |
|
8,390 |
7,730 |
|
|
|
|
|
|
TC |
11,630 |
10,550 |
10,070 |
9,590 |
|
9,010 |
8,290 |
|
|
|
|
|
|
CM |
0.82 |
0.89 |
0.95 |
1.02 |
|
1.09 |
1.15 |
|
|
|
70 |
(21.1) |
|
SHC |
6,130 |
5,910 |
5,700 |
5,490 |
|
5,240 |
4,930 |
|
|
63 |
73 |
(22.8) |
|
SHC |
7,180 |
6,960 |
6,750 |
6,540 |
|
6,290 |
5,980 |
|
|
(17.2) |
77 |
(25.0) |
|
SHC |
8,230 |
8,010 |
7,800 |
7,580 |
|
7,330 |
7,030 |
|
|
|
80 |
(26.7) |
|
SHC |
9,280 |
9,060 |
8,850 |
8,630 |
|
8,380 |
8,080 |
|
|
|
84 |
(28.9) |
|
SHC |
10,330 |
10,110 |
9,900 |
9,590 |
|
9,010 |
8,290 |
|
|
|
88 |
(31.1) |
|
SHC |
11,030 |
10,550 |
10,070 |
9,590 |
|
9,010 |
8,290 |
|
|
|
|
|
|
TC |
11,730 |
11,220 |
10,710 |
# 10,200 |
|
9,590 |
8,820 |
|
|
|
|
|
|
CM |
0.85 |
0.92 |
0.98 |
1.05 |
|
1.12 |
1.19 |
|
|
|
70 |
(21.1) |
|
SHC |
5,000 |
4,780 |
4,570 |
4,360 |
|
4,110 |
3,810 |
|
|
67 |
73 |
(22.8) |
|
SHC |
6,050 |
5,830 |
5,620 |
5,410 |
|
5,160 |
4,860 |
|
|
(19.4) |
77 |
(25.0) |
|
SHC |
7,090 |
6,880 |
6,670 |
6,460 |
|
6,210 |
5,910 |
|
|
|
80 |
(26.7) |
|
SHC |
8,140 |
7,930 |
7,720 |
7,510 |
|
7,260 |
6,960 |
|
|
|
84 |
(28.9) |
|
SHC |
9,190 |
8,980 |
8,770 |
8,560 |
|
8,310 |
8,010 |
|
|
|
88 |
(31.1) |
|
SHC |
10,240 |
10,030 |
9,820 |
9,610 |
|
9,360 |
8,820 |
|
|
|
|
|
|
TC |
12,430 |
11,890 |
11,350 |
10,810 |
|
10,160 |
9,350 |
|
|
|
|
|
|
CM |
0.87 |
0.94 |
1.01 |
1.08 |
|
1.15 |
1.22 |
|
|
|
73 |
(22.8) |
|
SHC |
4,900 |
4,690 |
4,480 |
4,280 |
|
4,040 |
3,740 |
|
|
70 |
77 |
(25.0) |
|
SHC |
5,950 |
5,740 |
5,530 |
5,330 |
|
5,090 |
4,790 |
|
|
(21.1) |
80 |
(26.7) |
|
SHC |
7,000 |
6,790 |
6,580 |
6,380 |
|
6,140 |
5,840 |
|
|
|
84 |
(28.9) |
|
SHC |
8,050 |
7,840 |
7,630 |
7,430 |
|
7,190 |
6,890 |
|
|
|
88 |
(31.1) |
|
SHC |
9,100 |
8,890 |
8,680 |
8,480 |
|
8,240 |
7,940 |
|
|
|
|
|
|
TC |
13,190 |
12,620 |
12,030 |
11,350 |
|
10,630 |
9,880 |
|
|
|
|
|
|
CM |
0.89 |
0.97 |
1.04 |
1.11 |
|
1.18 |
1.26 |
|
|
73 |
77 |
(25.0) |
|
SHC |
4,760 |
4,550 |
4,340 |
4,100 |
|
3,860 |
3,610 |
|
|
(22.8) |
80 |
(26.7) |
|
SHC |
5,810 |
5,600 |
5,390 |
5,150 |
|
4,900 |
4,650 |
|
|
|
84 |
(28.9) |
|
SHC |
6,850 |
6,650 |
6,440 |
6,200 |
|
5,950 |
5,700 |
|
|
|
88 |
(31.1) |
|
SHC |
7,900 |
7,700 |
7,490 |
7,250 |
|
7,000 |
6,750 |
|
|
TC : |
Total Cooling Capacity (BTU/h) |
|
|
|
|
|
|
||||
|
|
SHC : Sensible Heat Capacity (BTU/h) |
|
|
|
|
|
|
|||||
|
|
CM : |
Compressor Input (kW) |
|
|
|
|
|
|
||||
|
|
Rating conditions (#Mark) are |
|
|
|
|
|
|
|
||||
|
|
|
Outdoor Ambient Temp. 95°F (35°C) D.B. |
|
|
|
|
|
|||||
|
|
|
Indoor Air Intake Temp. 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B. |
|
|
10
Model |
|
STB1020C1 |
|
|
|
|
|
|
|
|
|
|
|
|
230 V Single phase 60 Hz |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RATING CAPACITY |
|
9,700 BTU/h |
|
|
|
|
|
||||
|
|
AIR FLOW RATE |
|
270 CFM |
|
|
|
|
|
||||
|
|
EVAPORATOR |
|
|
|
|
|
CONDENSER |
|
|
|||
|
|
ENT. TEMP. °F (°C) |
|
|
|
OUTDOOR AMBIENT TEMP. °F( °C) |
|
|
|||||
|
|
W.B. |
D.B. |
|
|
67 |
75 |
85 |
95 |
|
105 |
110 |
|
|
|
|
|
|
|
|
(19.4) |
(23.9) |
(29.4) |
(35.0) |
|
(40.6) |
(43.3) |
|
|
|
|
|
|
TC |
9,770 |
9,350 |
8,920 |
8,500 |
|
7,980 |
7,350 |
|
|
|
|
|
|
CM |
0.76 |
0.82 |
0.88 |
0.94 |
|
0.97 |
1.00 |
|
|
|
70 |
(21.1) |
|
SHC |
6,980 |
6,780 |
6,580 |
6,380 |
|
6,140 |
5,860 |
|
|
59 |
73 |
(22.8) |
|
SHC |
8,030 |
7,830 |
7,630 |
7,430 |
|
7,190 |
6,910 |
|
|
(15.0) |
77 |
(25.0) |
|
SHC |
9,080 |
8,880 |
8,680 |
8,480 |
|
7,980 |
7,350 |
|
|
|
80 |
(26.7) |
|
SHC |
9,770 |
9,350 |
8,920 |
8,500 |
|
7,980 |
7,350 |
|
|
|
84 |
(28.9) |
|
SHC |
9,770 |
9,350 |
8,920 |
8,500 |
|
7,980 |
7,350 |
|
|
|
88 |
(31.1) |
|
SHC |
9,770 |
9,350 |
8,920 |
8,500 |
|
7,980 |
7,350 |
|
|
|
|
|
|
TC |
11,060 |
10,030 |
9,570 |
9,120 |
|
8,570 |
7,890 |
|
|
|
|
|
|
CM |
0.78 |
0.84 |
0.90 |
0.97 |
|
1.00 |
1.02 |
|
|
|
70 |
(21.1) |
|
SHC |
5,890 |
5,690 |
5,490 |
5,290 |
|
5,050 |
4,760 |
|
|
63 |
73 |
(22.8) |
|
SHC |
6,940 |
6,740 |
6,540 |
6,340 |
|
6,100 |
5,810 |
|
|
(17.2) |
77 |
(25.0) |
|
SHC |
7,990 |
7,790 |
7,580 |
7,390 |
|
7,150 |
6,860 |
|
|
|
80 |
(26.7) |
|
SHC |
9,040 |
8,840 |
8,630 |
8,440 |
|
8,200 |
7,890 |
|
|
|
84 |
(28.9) |
|
SHC |
10,090 |
9,890 |
9,570 |
9,120 |
|
8,570 |
7,890 |
|
|
|
88 |
(31.1) |
|
SHC |
10,490 |
10,030 |
9,570 |
9,120 |
|
8,570 |
7,890 |
|
|
|
|
|
|
TC |
11,150 |
10,670 |
10,180 |
# 9,700 |
|
9,120 |
8,390 |
|
|
|
|
|
|
CM |
0.80 |
0.87 |
0.93 |
1.00 |
|
1.03 |
1.06 |
|
|
|
70 |
(21.1) |
|
SHC |
4,760 |
4,560 |
4,360 |
4,160 |
|
3,930 |
3,650 |
|
|
67 |
73 |
(22.8) |
|
SHC |
5,810 |
5,610 |
5,410 |
5,210 |
|
4,980 |
4,700 |
|
|
(19.4) |
77 |
(25.0) |
|
SHC |
6,860 |
6,660 |
6,460 |
6,260 |
|
6,030 |
5,750 |
|
|
|
80 |
(26.7) |
|
SHC |
7,910 |
7,710 |
7,510 |
7,310 |
|
7,080 |
6,800 |
|
|
|
84 |
(28.9) |
|
SHC |
8,960 |
8,760 |
8,560 |
8,360 |
|
8,130 |
7,850 |
|
|
|
88 |
(31.1) |
|
SHC |
10,010 |
9,810 |
9,610 |
9,410 |
|
9,120 |
8,390 |
|
|
|
|
|
|
TC |
11,820 |
11,310 |
10,800 |
10,280 |
|
9,670 |
8,890 |
|
|
|
|
|
|
CM |
0.83 |
0.89 |
0.96 |
1.03 |
|
1.06 |
1.09 |
|
|
|
73 |
(22.8) |
|
SHC |
4,670 |
4,470 |
4,280 |
4,090 |
|
3,860 |
3,580 |
|
|
70 |
77 |
(25.0) |
|
SHC |
5,720 |
5,520 |
5,330 |
5,140 |
|
4,910 |
4,630 |
|
|
(21.1) |
80 |
(26.7) |
|
SHC |
6,770 |
6,570 |
6,380 |
6,190 |
|
5,960 |
5,680 |
|
|
|
84 |
(28.9) |
|
SHC |
7,820 |
7,620 |
7,430 |
7,240 |
|
7,010 |
6,730 |
|
|
|
88 |
(31.1) |
|
SHC |
8,870 |
8,670 |
8,480 |
8,290 |
|
8,060 |
7,780 |
|
|
|
|
|
|
TC |
12,550 |
12,000 |
11,440 |
10,800 |
|
10,110 |
9,400 |
|
|
|
|
|
|
CM |
0.84 |
0.92 |
0.98 |
1.05 |
|
1.09 |
1.12 |
|
|
73 |
77 |
(25.0) |
|
SHC |
4,530 |
4,340 |
4,140 |
3,920 |
|
3,690 |
3,450 |
|
|
(22.8) |
80 |
(26.7) |
|
SHC |
5,580 |
5,390 |
5,190 |
4,970 |
|
4,740 |
4,500 |
|
|
|
84 |
(28.9) |
|
SHC |
6,630 |
6,440 |
6,240 |
6,020 |
|
5,790 |
5,550 |
|
|
|
88 |
(31.1) |
|
SHC |
7,680 |
7,490 |
7,290 |
7,070 |
|
6,840 |
6,600 |
|
|
TC : |
Total Cooling Capacity (BTU/h) |
|
|
|
|
|
|
||||
|
|
SHC : Sensible Heat Capacity (BTU/h) |
|
|
|
|
|
|
|||||
|
|
CM : |
Compressor Input (kW) |
|
|
|
|
|
|
||||
|
|
Rating conditions (#Mark) are |
|
|
|
|
|
|
|
||||
|
|
|
Outdoor Ambient Temp. 95°F (35°C) D.B. |
|
|
|
|
|
|||||
|
|
|
Indoor Air Intake Temp. 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B. |
|
|
11
Model |
|
STB1220C1 |
|
|
|
|
|
|
|
|
|
|
|
|
230 V Single phase 60 Hz |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RATING CAPACITY |
|
11,500 BTU/h |
|
|
|
|
|
||||
|
|
AIR FLOW RATE |
|
270 CFM |
|
|
|
|
|
||||
|
|
EVAPORATOR |
|
|
|
|
|
CONDENSER |
|
|
|||
|
|
ENT. TEMP. °F (°C) |
|
|
|
OUTDOOR AMBIENT TEMP. °F( °C) |
|
|
|||||
|
|
W.B. |
D.B. |
|
|
67 |
75 |
85 |
95 |
|
105 |
110 |
|
|
|
|
|
|
|
|
(19.4) |
(23.9) |
(29.4) |
(35.0) |
|
(40.6) |
(43.3) |
|
|
|
|
|
|
TC |
11,590 |
11,080 |
10,580 |
10,070 |
|
9,460 |
8,710 |
|
|
|
|
|
|
CM |
0.92 |
0.99 |
1.06 |
1.14 |
|
1.21 |
1.28 |
|
|
|
70 |
(21.1) |
|
SHC |
7,880 |
7,620 |
7,370 |
7,130 |
|
6,830 |
6,480 |
|
|
59 |
73 |
(22.8) |
|
SHC |
8,930 |
8,670 |
8,420 |
8,180 |
|
7,880 |
7,530 |
|
|
(15.0) |
77 |
(25.0) |
|
SHC |
9,980 |
9,720 |
9,470 |
9,230 |
|
8,930 |
8,580 |
|
|
|
80 |
(26.7) |
|
SHC |
11,030 |
10,770 |
10,520 |
10,070 |
|
9,460 |
8,710 |
|
|
|
84 |
(28.9) |
|
SHC |
11,590 |
11,080 |
10,580 |
10,070 |
|
9,460 |
8,710 |
|
|
|
88 |
(31.1) |
|
SHC |
11,590 |
11,080 |
10,580 |
10,070 |
|
9,460 |
8,710 |
|
|
|
|
|
|
TC |
13,110 |
11,890 |
11,350 |
10,810 |
|
10,160 |
9,350 |
|
|
|
|
|
|
CM |
0.94 |
1.02 |
1.09 |
1.17 |
|
1.24 |
1.31 |
|
|
|
70 |
(21.1) |
|
SHC |
6,790 |
6,530 |
6,280 |
6,040 |
|
5,740 |
5,390 |
|
|
63 |
73 |
(22.8) |
|
SHC |
7,840 |
7,580 |
7,330 |
7,090 |
|
6,790 |
6,440 |
|
|
(17.2) |
77 |
(25.0) |
|
SHC |
8,890 |
8,630 |
8,380 |
8,140 |
|
7,840 |
7,490 |
|
|
|
80 |
(26.7) |
|
SHC |
9,940 |
9,680 |
9,430 |
9,190 |
|
8,890 |
8,540 |
|
|
|
84 |
(28.9) |
|
SHC |
10,990 |
10,730 |
10,480 |
10,230 |
|
9,940 |
9,350 |
|
|
|
88 |
(31.1) |
|
SHC |
12,040 |
11,780 |
11,350 |
10,810 |
|
10,160 |
9,350 |
|
|
|
|
|
|
TC |
13,220 |
12,650 |
12,070 |
# 11,500 |
|
10,810 |
9,950 |
|
|
|
|
|
|
CM |
0.97 |
1.05 |
1.13 |
1.21 |
|
1.28 |
1.35 |
|
|
|
70 |
(21.1) |
|
SHC |
5,650 |
5,400 |
5,150 |
4,900 |
|
4,620 |
4,260 |
|
|
67 |
73 |
(22.8) |
|
SHC |
6,700 |
6,450 |
6,200 |
5,950 |
|
5,670 |
5,310 |
|
|
(19.4) |
77 |
(25.0) |
|
SHC |
7,750 |
7,500 |
7,250 |
7,000 |
|
6,720 |
6,360 |
|
|
|
80 |
(26.7) |
|
SHC |
8,800 |
8,550 |
8,300 |
8,050 |
|
7,770 |
7,410 |
|
|
|
84 |
(28.9) |
|
SHC |
9,850 |
9,600 |
9,350 |
9,100 |
|
8,810 |
8,460 |
|
|
|
88 |
(31.1) |
|
SHC |
10,900 |
10,650 |
10,400 |
10,150 |
|
9,860 |
9,510 |
|
|
|
|
|
|
TC |
14,020 |
13,410 |
12,800 |
12,190 |
|
11,460 |
10,540 |
|
|
|
|
|
|
CM |
1.00 |
1.08 |
1.16 |
1.24 |
|
1.32 |
1.39 |
|
|
|
73 |
(22.8) |
|
SHC |
5,550 |
5,300 |
5,050 |
4,810 |
|
4,530 |
4,190 |
|
|
70 |
77 |
(25.0) |
|
SHC |
6,600 |
6,350 |
6,100 |
5,860 |
|
5,580 |
5,230 |
|
|
(21.1) |
80 |
(26.7) |
|
SHC |
7,650 |
7,400 |
7,150 |
6,910 |
|
6,630 |
6,280 |
|
|
|
84 |
(28.9) |
|
SHC |
8,700 |
8,450 |
8,200 |
7,960 |
|
7,680 |
7,330 |
|
|
|
88 |
(31.1) |
|
SHC |
9,750 |
9,500 |
9,250 |
9,010 |
|
8,730 |
8,380 |
|
|
|
|
|
|
TC |
14,880 |
14,230 |
13,560 |
12,800 |
|
11,980 |
11,140 |
|
|
|
|
|
|
CM |
1.02 |
1.11 |
1.19 |
1.27 |
|
1.35 |
1.43 |
|
|
73 |
77 |
(25.0) |
|
SHC |
5,380 |
5,140 |
4,890 |
4,620 |
|
4,330 |
4,040 |
|
|
(22.8) |
80 |
(26.7) |
|
SHC |
6,430 |
6,190 |
5,940 |
5,670 |
|
5,380 |
5,090 |
|
|
|
84 |
(28.9) |
|
SHC |
7,480 |
7,240 |
6,990 |
6,720 |
|
6,430 |
6,140 |
|
|
|
88 |
(31.1) |
|
SHC |
8,530 |
8,290 |
8,040 |
7,770 |
|
7,480 |
7,190 |
|
|
TC : |
Total Cooling Capacity (BTU/h) |
|
|
|
|
|
|
||||
|
|
SHC : Sensible Heat Capacity (BTU/h) |
|
|
|
|
|
|
|||||
|
|
CM : |
Compressor Input (kW) |
|
|
|
|
|
|
||||
|
|
Rating conditions (#Mark) are |
|
|
|
|
|
|
|
||||
|
|
|
Outdoor Ambient Temp. 95°F (35°C) D.B. |
|
|
|
|
|
|||||
|
|
|
Indoor Air Intake Temp. 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B. |
|
|