Sanyo THX1852, THX1252, AHX1252, XHX2452, XHX1252 User Manual

...
0 (0)

Save These Instructions!

This air conditioner uses the new refrigerant R410A.

 

 

 

 

 

 

 

 

 

 

 

 

SEMI-CONCEALED

CEILING-MOUNTED

WALL-MOUNTED

CONCEALED-DUCT

 

 

 

 

 

 

 

(4-WAY)

(1-WAY)

THX1252

KHX0752

(Standard Static Pressure)

 

XHX1252

AHX0752

THX1852

KHX0952

UHX0752

 

XHX1852

AHX0952

THX2452

KHX1252

UHX1252

 

XHX2452

AHX1252

 

KHX1852

UHX1852

 

XHX3652

 

 

KHX2452

UHX2452

 

 

 

 

 

UHX3652

 

 

 

 

 

(High Static Pressure)

 

 

 

 

 

DHX3652

 

 

 

 

 

DHX4852

 

 

 

 

 

 

 

Split System Air Conditioner • INSTRUCTION MANUAL

Remote Controllers

Timer Wired Remote Controller

RCS-TM80BG

 

 

Wireless Remote Controller (for U, D type)

RCS-BH80AAB.WL

 

 

Wireless Remote Controller (for X type)

RCS-SH80AAB.WL

 

 

Wireless Remote Controller (for A, T type)

RCS-TRP80AAB.WL

 

 

Wireless Remote Controller (for K type)

RCS-SH1AAB

 

 

* Timer Wired Remote Controller comes with Instruction Manual.

Pub. OI-85464189837000

SANYO Electric Co., Ltd.

© SANYO 2006

Gunma, Japan

 

Contents

 

 

Page

Product Information .......................................................................................................................

2

Alert Symbols ................................................................................................................................

2

Installation Location.......................................................................................................................

3

Electrical Requirements ................................................................................................................

3

Safety Instructions.........................................................................................................................

3

Wireless Remote Control Unit (Optional parts) .............................................................................

4

Parts Name and Functions ......................................................................................................

4

Receiver...................................................................................................................................

7

Operation .................................................................................................................................

8

Using the Wireless Remote Control Unit .................................................................................

9

Address Settings....................................................................................................................

10

Emergency Operation............................................................................................................

12

Troubleshooting .....................................................................................................................

14

Adjusting the Airflow Direction.....................................................................................................

15

Adjusting the Airflow Direction for Multiple Indoor Units Using a Single Remote Control Unit ....17

Special Remarks .........................................................................................................................

17

Setting the Timer .........................................................................................................................

18

Product Information

 

If you have problems or questions concerning your Air Conditioner, you will need the following

information. Model and serial numbers are on the nameplate on the bottom of the cabinet.

Model No. _________________________________

Serial No. _______________________

Date of purchase ______________________________________________________________

Dealer’s address ______________________________________________________________

 

Phone number ___________________

Alert Symbols

The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

2

OI-837-2-EG

 

Installation Location

We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.

Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.

Do not install this air conditioner where there are fumes or flammable gases, or in an

extremely humid space such as a greenhouse.

Do not install the air conditioner where excessively high heat-generating objects are placed.

Avoid: To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.

Electrical Requirements

1.All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.

2.Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.

3.Wiring must be done by a qualified electrician.

 

 

 

To warm up the system, the power mains must be turned on

Power mains

 

 

 

at least five (5) hours before operation. Leave the power

ON

 

 

 

 

 

 

 

 

 

mains ON unless you will not be using this appliance for an

 

 

 

 

 

 

 

extended period.

 

 

 

 

 

 

Safety Instructions

Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.

This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.

Never touch the unit with wet hands.

• Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous.

This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.

Do not turn the air conditioner on and off from the power mains switch. Use the ON/ OFF operation button.

Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.

Do not let children play with the air conditioner.

Do not cool or heat the room too much if babies or invalids are present.

OI-837-3-EG

3

 

Sanyo THX1852, THX1252, AHX1252, XHX2452, XHX1252 User Manual

Wireless Remote Control Unit (Optional parts)

Parts Name and Functions

 

B: Transmitter

 

O: Remote control sensor

C: MODE button

A: ON/OFF operation button

 

E: FAN SPEED selector button

D: Temperature setting buttons

 

J: TIMER SET button

I: FLAP button

 

K: Time setting buttons

 

 

G: ADDRESS button

L: SET button

 

M: CL button

F: FILTER button

 

P: ACL button

N: VENTILATION button

 

(ALL CLEAR)

H: A/C SENSOR button

 

 

Q: Slide switch

NOTE The illustration above pictures the wireless remote control unit after the cover has been lowered and removed.

A:

ON/OFF operation

This button is for turning the air conditioner on and off.

 

 

 

button

 

 

 

 

 

 

 

B:

Transmitter

When you press the buttons on the wireless remote control unit, the

mark appears in the

 

 

display to transmit the setting changes to the receiver in the air conditioner.

 

 

 

C: MODE button

Use this button to select one of the following five operating modes.

 

 

(AUTO)

: Used to automatically set cooling or heating operation. Only for single heat pump type

 

 

 

 

 

(temperature range: 62 to 80°F)

 

(HEAT)

: Used for normal heating operation. Only for heat pump type

 

 

 

 

(temperature range: 60 to 78°F)

 

(DRY)

: Used for dehumidifying without changing the room temperature.

 

 

 

 

(temperature range: 64 to 86°F)

 

(COOL)

: Used for normal cooling operation.

(temperature range: 64 to 86°F)

 

(FAN)

: Used to run the fan only, without heating or cooling operation.

 

 

 

 

 

 

D:

Temperature setting

: Press this button to increase the temperature setting.

 

 

 

buttons

: Press this button to decrease the temperature setting.

 

 

E:FAN SPEED selector button

(AUTO)

: The air conditioner automatically decides the fan speeds.

(HI.)

: High fan speed

(MED.)

: Medium fan speed

(LO.)

: Low fan speed

 

 

F: FILTER button

If a separately installed signal receiver is being employed, this button is used to turn off its

 

filter lamp. When the filter lamp has lighted, first clean the filter, and then press the FILTER

 

button to turn off the filter lamp.

 

When a wired remote control unit and wireless remote control unit are both used, the filter sign

 

on the wired remote control unit will be appeared. When this happens, first clean the filter, and

 

then press the FILTER button on one of the remote control units to turn off the filter sign.

4

OI-837-4-EG

 

 

 

Parts Name and Functions (continued)

 

 

 

G: ADDRESS button

When a multiple number of indoor units that can be operated by the wireless remote control

 

 

unit have been installed in the same room with a multi-unit or single-unit installation, this

 

 

button enables addresses to be set in order to prevent the sending of signals to the wrong

 

 

indoor unit. Each of up to six indoor units can be controlled separately using its own wireless

 

 

remote control unit by matching the number of the address switch on the operation area of the

 

 

indoor unit and the number used for the address of its remote control unit. (The indoor units

 

 

cannot be controlled separately when they are used in a flexible combination format,

 

 

simultaneous operation of multi units format or any other such format since they will all

 

 

operate at the same time.)

 

 

 

When the batteries are replaced, the address setting returns to “ALL”, and so please make the

 

NOTE

 

 

setting again.

 

 

 

 

 

 

 

 

 

H: A/C SENSOR button

When you press this button (use a small-tipped object such as a ballpoint pen), the

 

 

indication will disappear at the display. And the room temperature is detected by the sensor

 

 

which is built in the indoor unit and the air conditioner is controlled accordingly.

 

 

If the remote control is located near a heat source, such as a space heater or in direct

 

NOTE

 

 

sunlight, press the A/C SENSOR button to switch to the sensor on the indoor unit.

 

 

 

 

 

I: FLAP button

1. Use this button to set the airflow direction to a specific angle.

 

 

The airflow direction is displayed on the remote control unit.

 

 

Operation mode

Number of airflow direction settings

 

 

(COOL) or

(DRY)

3

 

 

(HEAT) or

(FAN)

5

 

 

(AUTO)

 

 

 

 

Cooling mode:

3

 

 

Heating mode:

5

• In the cool mode and dry mode, if the flaps are set in a downward position, condensation may form and drip around the vent.

• Do not move the flap with your hands.

NOTE This function is available only for models X, A, T and K.

(SWEEP) 2. Use this button to make the airflow direction sweep up and down automatically.

Press this button several times until the symbol appears on the display.

To stop the swing operation

Press the FLAP button again during the flap swing operation to stop the flap at the desired position. Then, the airflow can be set from the top position by pressing the FLAP button again.

Indicator when swing operation is stopped

Fan and heating

Cooling and drying

 

 

 

 

During cooling and drying, the flap does not stop at the downward position. Even if the flap is stopped at the downward position during the swing operation, it does not stop until it moves to the third position from the top.

 

NOTE

This function is available only for models X, A, T and K.

 

 

 

 

 

 

J: TIMER SET button

Use this button while the unit is operating to switch between timer settings.

(OFF Timer)

:

The air conditioner stops after a preset time elapses.

(OFF Cycle Timer)

 

 

 

:The air conditioner always stops after a preset time elapses.

(ON Timer)

 

 

:

The air conditioner starts after a preset time elapses.

 

OI-837-5-EG

5

 

 

 

Parts Name and Functions (continued)

 

 

 

K:

Time setting buttons

: Press this button to increase the time.

 

 

: Press this button to decrease the time.

 

 

 

L:

SET button

Use this button to set the timer.

 

 

 

M:

CL button

Use this button to clear the timer setting.

N: VENTILATION button This is used when a ventilation fan (available commercially) is connected. Pressing the VENTILATION button turns the fan on and off. The ventilation fan also turns on and off when the air conditioner unit is turned on and off. (The display of the remote control unit shows

” while the ventilation fan is running.)

*If the VENTILATION button is held down for 4 or more seconds when the batteries have been replaced, “ ” appears on the display, and the ventilation fan can be used.

O:Remote control sensor This detects the temperature around the remote control unit when the remote control unit

position has been selected using the sensor button.

P:

ACL button (ALL CLEAR)

Puts the wireless remote control unit into pre-operation status. This is used after the batteries

 

 

 

have been replaced or when the slide switch setting has been changed.

 

 

 

 

Q:

Slide switch

This switch is for setting the operation mode of the indoor unit and setting the flaps.

 

 

 

 

 

 

 

• The wireless remote control unit sends the temperature signal to the air conditioner

 

 

NOTE

regularly at five-minute intervals. If the signal from the wireless remote control unit stops for more than ten minutes due to the loss of the wireless remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the wireless remote control unit may differ from the temperature detected at the air conditioner’s position.

• When low fan speed is selected and the air conditioner is in cooling operation at a low outdoor temperature of less than 50°F, the air conditioner may automatically switch to medium fan speed to prevent freezing.

6

OI-837-6-EG

 

Loading...