Samsung NX-308 User Manual

0 (0)
Samsung NX-308 User Manual

1999.9.15 12:40 PM 1

NX-SERIES

Technical Manual

NX-308

NX-820

NX-1232

0preface 1999.9.15 12:46 PM 1

PUBLICATION INFORMATION

SAMSUNG ELECTRONICS Co. reserves the right to revise information in this publication for any reason without prior notice.

SAMSUNG ELECTRONICS Co.

also reserves the right to make changes in equipment design or components as engineering and manufacturing may warrant without prior notice .

COPYRIGHT 1997 SAMSUNG ELECTRONICS Co.

All rights reserved. No part of this manual may be reproduced in any form or by any means --- graphic, electronic or mechanical, including recording, taping, photocopying or information retrieval systems --- without express written permission of the publisher of this material.

0preface 1999.9.15 12:46 PM 2

0preface 1999.9.15 12:46 PM 3

NX-SERIES

NX-308 NX-820 NX-1232

ELECTRONIC KEY/HYBRID

TELEPHONE SYSTEM

TECHNICAL MANUAL

INCLUDES :

GENERAL DESCRIPTION SECTION

INSTALLATION SECTION

FEATURE SECTION

PROGRAMMING SECTION

APPENDIX SECTION

BACK-UP DATA SHEETS

0preface 1999.9.15 12:46 PM 4

1GENERAL 1999.9.15 12:46 PM 1

GENERAL DESCRIPTION

SECTION

1GENERAL 1999.9.15 12:46 PM 2

1GENERAL 1999.9.15 12:46 PM 3

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

TABLE OF CONTENTS

GENERAL DESCRIPTION

NX-SERIES GENERAL SYSTEM DIAGRAM . . . . . . . . . . . . . . . . . 1-1

1. SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

1.1 NX-308 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.2 NX-820 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.3 NX-1232 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

2. NX-SERIES LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

2.1 TOP VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2.2 SIDE VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

3. SYSTEM CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

3.1 NX-308 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 3.2 NX-820 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 3.3 NX-1232 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

4. HARDWARE DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

4.1 KSU (Key Service Unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 4.2 EXPANSION CARDS & OPTION BOARDS . . . . . . . . . . . . . . . 1-6 4.3 STATION EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

5. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

5.1 ELECTRICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . 1-8 5.2 DIMENSIONS AND WEIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

1GENERAL 1999.9.15 12:46 PM 4

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

5.3 ENVIRONMENTAL LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . 1-8 5.4 CABLE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 5.5 SYSTEM TONES AND RINGS . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 5.6 KEYSET LED INDICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10

1GENERAL 1999.9.15 12:46 PM 5

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

NX-SERIES GENERAL SYSTEM DIAGRAM

1 - 1

1GENERAL 1999.9.15 12:46 PM 6

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

1. SYSTEM OVERVIEW

The NX-series hybrid key system accomodates three kinds of Key Station:

NX-308, NX-820 and NX-1232.

1.1 NX-308 SYSTEM

The NX-308, with a maximum capacity of three telephone C.O. lines and eight stations, is an analog telephone system designed for the small-sized business.

A powerful HM64180R1 digital microprocessor controls all speech paths and system functions. The operating program with default memory is stored in nonvolatile ROM 27C020. Customer data is stored in RAM 62256 and is protected for up to seven continuous days' loss of system power by a Ni-Cd battery. When AC power is restored, the Ni-Cd battery is recharged automatically.

1.2 NX-820 SYSTEM

Designed for small to medium-sized businesses, the NX-820 is an analog telephone system featuring a maximum capacity of forty (40) ports, made up of the combined total of C.O. telephone lines and stations, permitting various configurations. Comprised of a Key Service Unit, expansion boards, electronic keysets and conventional single line telephones, the NX-820 offers small or medium-sized business users flexible control of telephone communications. A powerful HM64180R1 digital microprocessor controls all speech paths and system functions. The operating program with default memory is stored in non-volatile ROM 27C020. Customer data is stored in RAM 681000, and is protected for up to seven continuous days' loss of system power by a Ni-Cd battery. When AC power is restored, the Ni-Cd battery is recharged automatically.

1.3 NX-1232 SYSTEM

The NX-1232 is an analog telephone system designed for small to medium-sized business. The NX-1232 system has a maximum capacity of forty eight (48) ports, made up of the combined total of C.O. telephone lines and stations, permitting various configurations. Comprised of a Key Service Unit, expansion boards, electronic keysets and conventional single line telephones, the NX-1232 system offers small or medium-sized business users flexible control of telephone communications. A powerful HM64180R1 digital microprocessor controls all speech paths and system functions. The operating program with default memory is stored in non-volatile ROM 27C020. Customer data is stored in RAM 681000, and is protected for up to seven continuous days' loss of system power by a Ni-Cd battery. When AC power is restored, the Ni-Cd battery is recharged automatically.

1 - 2

1GENERAL 1999.9.15 12:46 PM 7

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

2.NX-SERIES LAYOUT

2.1TOP VIEW

“POWER” LED

“MONITOR” LED “IDLE” LCD

2.2 SIDE VIEW

MDF Cable Path

External Battery Connector

Fuse Holder

Power Switch

Power Cable

1 - 3

1GENERAL 1999.9.15 12:46 PM 8

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

3. SYSTEM CONFIGURATION

3.1 NX-308 SYSTEM

The basic KSU (Key Service Unit) comes equipped to operate three telephone lines and eight stations. Station #1 is assigned to be used with a keyset and stations #2 through #8 are assigned as keysets or single-line telephones.

The NX-SMDR/R-MMC board is the SMDR and REMOTE MMC serial interface, and the NX-DPH/PAGING board is the door phone and external paging interface. These optional boards can be installed on the base board

3.2 NX-820 SYSTEM

The basic KSU (Key Service Unit) comes equipped to operate four telephone lines and twelve stations. Stations #1 through #4 are assigned to be used with keysets and stations #5 through #12 are assigned for single-line telephones. The NX-820 system accomodates several kinds of expansion card. The NX-2TRK, NX-4TRK, NX-4KLI, NX-4SLI, NX-4OPX, NX-8KLI and NX-8SLI cards may be installed in any of the three expansion slots. By combining these cards, the NX-820 system can be increased to its maximum capacity of forty ports. Optionally, the NX-SMDR/R-MMC, NXDPH/PAGING, NX-MPD and NX-PRS board can be installed on the base board. The NX-SMDR/R-MMC board is the SMDR and REMOTE MMC serial interface, the NX-DPH/PAGING board is the door phone and external paging interface and the NX-MPD, NX-PRS board are interface for calculating call cost.

But, maximum keyphone part is restricted to twenty four(24) ports although three NX-8KLI cards are used.

16

12

8

4

4

8

12

20

28

36

No. of Stations

Basic KSU

Basic KSU, one 8 SLI (or 8 KLI) Board and one 4 TRK Card

Basic KSU, one 8 SLI (or 8 KLI) Board and two 4 TRK Cards

Basic KSU and three 4 TRK Cards

Basic KSU, two 8 SLI (or 8 KLI) Boards and one 4 TRK Cards

Basic KSU and three 8 SLI (or 8 KLI) Cards

1 - 4

1GENERAL 1999.9.15 12:46 PM 9

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

3.3 NX-1232 SYSTEM

The basic KSU (Key Service Unit) comes equipped to operate eight telephone lines and sixteen stations. Stations #1 through #8 are assigned to be used with keysets or single line telephones, and stations #9 through #16 are assigned for single line telephones. The NX-1232 system accepts several kinds of expansion cards. The NX-2TRK, NX-4TRK, NX-4KLI, NX-4SLI, NX-4OPX, NX-8KLI, NX8SLI cards can be installed in any of the three expansion slots. By combining these cards, the NX-1232 system can be increased to its maximum capacity of forty eight ports.

Optionally, the NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS board can be installed on the base board. The NX-SMDR/R-MMC board is the SMDR and REMOTE MMC serial interface, the NX-DPH/PAGING board is the door phone and external paging interface and the NX-MPD, NX-PRS board are interface for calculating call cost.

But, maximum keyphone part is restricted to twenty four(24) ports although three NX-8KLI cards are used.

20

16

12

8

8

16

24

32

40

No. of Stations

Basic KSU

Basic KSU, one 8 SLI (or 8 KLI) Board and one 4 TRK Card

Basic KSU, one 8 SLI (or 8 KLI) Board and two 4 TRK Cards

Basic KSU and three 4 TRK Cards

Basic KSU, two 8 SLI (or 8 KLI) Board and one 4 TRK Card

Basic KSU and three 8 SLI (or 8 KLI) Cards

1 - 5

1GENERAL 1999.9.15 12:46 PM 10

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

4. HARDWARE DESCRIPTION

4.1 KSU (Key Service Unit)

The KSU of the NX-series is a single cabinet, wall mounted, metal cased unit, containing the following:

Power Supply

Processing, switching, and customer memory for all ports.

Internal music source and External music interface

2 Power Failure Transfer

Back-up Battery for memory protection

Real Time Clock (RTC)

NX-308 SYSTEM

 

NX-820 SYSTEM

 

NX-1232 SYSTEM

3 Trunk interfaces

 

4 Trunk interfaces

 

8 Trunk interfaces

1 keyset, 7 Hybrid

 

4 KTS and 8 SLT

 

8 hybrid and 8 SLT

station interfaces

 

station interfaces

 

station interfaces

 

 

 

 

 

4.2EXPANSION CARDS & OPTION BOARDS

NX-2TRK card provides two loop start trunk interfaces.

can be installed NX-820 and NX-1232 system.

NX-4TRK card provides four loop start trunk interfaces.

can be installed NX-820 and NX-1232 system.

NX-4KLI card provides four ports for keysets.

can be installed NX-820 and NX-1232 system.

NX-4SLI card provides four SLI ports for industry standard single line telephones.

can be installed NX-820 and NX-1232 system.

NX-4OPX card provides four OPX line port for industry standard single line

telephones and can be connected to PBX lines.

can be installed NX-820 and NX-1232 system.

NX-8KLI card provides eight ports for keysets.

can be installed NX-820 and NX-1232 system.

NX-8SLI card provides eight SLI port for industry standard single line telephones.

can be installed NX-820 and NX-1232 system.

NX-MPD board provides two ports for metering pulse detection.

can be installed NX-820 and NX-1232 system.

NX-PRS board provides two ports for polarity reverse signal detection.

can be installed NX-820 and NX-1232 system.

NX-SMDR/R-MMC board provides two serial ports for SMDR and

REMOTE MMC.

can be installed all NX-SERIES system.

NX-DPH/PAGING board provides two DOOR PHONE interface and one

EXTERNAL PAGING interface.can be installed all NX-SERIES system.

1 - 6

1GENERAL 1999.9.15 12:46 PM 11

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

4.3STATION EQUIPMENT

Keyset with 24 buttons (NX-24E, NX-24B)

Built-in speakerphone

24 programmable soft keys (12 with tri-colored LEDs) and 10 fixed-function keys

UP/DOWN buttons for digital control of speaker, handset, and ringer volumes.

Four selectable ring tones per keyset

Deskor wallmount

NX-24E keyset with 16 character display

Keyset with 12 buttons (NX-12E, NX-12B)

Built-in speakerphone

12 programmable soft keys (6 with tri-colored LEDs) and 10 fixed-function keys

UP/DOWN buttons for digital control of speaker, handset, and ringer volumes.

Four selectable ring tones per keyset

Deskor wallmount

NX-12E keyset with 16 character display

Basic keyset with 6 buttons (NX-6B)

6 programmable soft keys and 10 fixed-function keys

UP/DOWN buttons for digital control of speaker, handset, and ringer volumes.

Four selectable ring tones per keyset

Deskor wallmount

Add On Module (NX-AOM)

24 programmable soft keys

 

NX-24E

 

NX-24B

 

NX-12E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NX-12B

NX-6B

NX-AOM

1 - 7

1GENERAL 1999.9.15 12:46 PM 12

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

5. SPECIFICATIONS

5.1 ELECTRICAL SPECIFICATIONS

AC INPUT

110/220 VAC, 50/60 Hz

 

POWER

NX-308

50 WATTS MAX

CONSUMPTION

NX-820

55 WATTS MAX

 

NX-1232

80 WATTS MAX

MAX CURRENT

NX-308

0.22 AMP

DRAW AT 220 VAC

NX-820

0.29 AMP

 

NX-1232

0.36 AMP

RING GENERATOR

AC 80 Vrms, 25 Hz

 

BATTERY BACKUP

24 VDC, 6 to 26Ah

 

SUPPLY

 

 

 

 

 

 

5.2 DIMENSIONS AND WEIGHTS

NX-308

530mm(H) x 348mm(W) x 102mm(D),

4.9Kg

KEY SERVICE UNIT NX-820

530mm(H) x 412mm(W) x 140mm(D),

8.9Kg

NX-1232

530mm(H) x 412mm(W) x 140mm(D),

8.9Kg

KEYSET

214mm(H) x 206mm(W) x 150mm(D),

1.1Kg

AOM

214mm(H) x 133mm(W) x 150mm(D),

0.4Kg

DOOR PHONE

158mm(H) x 89mm(W) x 41mm(D),

0.23Kg

 

 

 

5.3 ENVIRONMENTAL LIMITATIONS

OPERATING TEMPERATURES

0 - 45 (18 - 25 recommended)

OPERATING HUMIDITY

10% - 90% (non-condensing)

 

 

5.4 CABLE REQUIREMENTS

ELECTRONIC SET

2 pair twisted, Max. 400 m (24 AWG)

SINGLE LINE TELEPHONE

1 pair twisted, Max. 1 km (24 AWG)

DOOR PHONE

1 pair twisted, Max. 100 m (24 AWG)

4 OPX B’D

1 pair twisted, Max. 2Km (24 AWG)

 

 

1 - 8

1GENERAL 1999.9.15 12:46 PM 13

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

5.5 SYSTEM TONES AND RINGS

DIAL TONE : A steady tone that indicates dialing may begin

CONTINUOUS

RING-BACK TONE : Indicates the station dialed is ringing.

400 ON / 200 OFF/

400 ON / 3000 OFF

BUSY TONE: Indicates the station dialed is busy.

500 ON / 500 OFF/

500 ON / 500 OFF

TRANSFER TONE: Indicates a call is being held and you can dial another party.

200 ON / 200 OFF /

200 ON / 200 OFF

ERROR TONE: Indicates you have done something incorrectly.

500 ON / 250 OFF /

500 ON / 250 OFF

CONFIRMATION TONE: Indicates you have correctly set or canceled a system feature.

100 ON / 100 OFF /

100 ON / 100 OFF

INTRUSION TONE: Indicates you have been barged-in on.

200 ON / 200 OFF /

200 ON / 5000 OFF

MESSAGE WAITING TONE: Indicates messages on SLT type station.

1000 ON / 250 OFF /

1000 ON / 250 OFF

CAMP-ON REMINDER TONE: Indicates a call transfered to you while you are busy.

1000 ON / 15000 OFF /

1000 ON / 15000 OFF

CO LINE RING: Indicates an outside call is ringing on your station.

1000 ON / 3000 OFF /

1000 ON / 3000 OFF

1 - 9

1GENERAL 1999.9.15 12:46 PM 14

NX-SERIES HYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

STATION RING: Indicates an intercom call is ringing on your station.

400 ON / 200 OFF /

400 ON / 3000 OFF

DOORPHONE RING: Indicates a doorphone call is ringing on your station.

500 ON / 500 OFF /

500 ON / 500 OFF

ALARM RING: Indicates an alarm is ringing on your station.

500 ON / 500 OFF /

500 ON / 500 OFF

NOTE : The details may vary according to the regulations or customers reguest.

5.6 KEYSET LED INDICATIONS

CONDITION

LED COLOR

LED STATUS

LINE IDLE

OFF

LINE IN USE

RED or GREEN

STEADY ON

RECALL

AMBER

FAST FLASH

CALL ON HOLD

RED or GREEN

SLOW FLASH

RINGING C.O. CALL

RED or GREEN

FAST FLASH

RINGING INTERNAL CALL

GREEN

FAST FLASH

DND INDICATION

RED

STEADY ON

1 - 10

2INSTALL 1999.9.15 12:45 PM 1

INSTALLATION SECTION

2INSTALL 1999.9.15 12:45 PM 2

2INSTALL 1999.9.15 12:45 PM 4

NX-SERIES HYBRID KEY SYSTEM INSTALLATION SECTION

4 MDF CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-9

4.1 Clip type MDF Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-19

4.2

Using to Cable tie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-19

5. CONNECTING TELEPHONE LINES . . . . . . . . . . . . . . . . . . . . .

2-20

5.1

SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-20

5.2

LOOP START LINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-20

6. CONNECTING STATION EQUIPMENT . . . . . . . . . . . . . . . . . .

2-20

6.1 CONNECTING KEYSET / AOM . . . . . . . . . . . . . . . . . . . . . . . .

2-20

 

6.1.1 NX-308 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-20

 

6.1.2 NX-820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-21

 

6.1.3 NX-1232 Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . .

2-21

6.2 CONNECTING Single-Line Tel. . . . . . . . . . . . . . . . . . . . . . . . . 2-21

 

6.2.1 NX-308 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-22

 

6.2.2 NX-820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-22

 

6.2.3 NX-1232 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . .

2-22

7. CONNECTING OPTIONAL EQUIPMENT . . . . . . . . . . . . . . . .

2-27

7.1 EXTERNAL MUSIC SOURCE . . . . . . . . . . . . . . . . . . . . . . . . . .

2-27

7.2

EXTERNAL PAGING FOR STANDARD . . . . . . . . . . . . . . . . .

2-27

7.3

DOORPHONE AND DOOR LOCK RELEASE . . . . . . . . . . . .

2-28

7.4 SMDR / REMOTE PROGRAMMING . . . . . . . . . . . . . . . . . . . .

2-29

7.5 POWER FAILURE TRANSFER . . . . . . . . . . . . . . . . . . . . . . . .

2-31

 

7.5.1 NX-308 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-31

 

7.5.2 NX-820 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-31

 

7.5.3 NX-1232 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-31

7.6

EXTERNAL BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-31

8. BEFORE POWER UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-32

9 INSTALLING TO KEYSET . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-33

9-1 CONNECTING TO LINE CORD . . . . . . . . . . . . . . . . . . . . . . . .2-33 9-2 WALL-MOUNTING A KEYSET . . . . . . . . . . . . . . . . . . . . . . . . .2-33 9-3 HOW TO REMOVE THE HANDSET CORD FROM THE HANDSET .2-34

2INSTALL 1999.9.15 12:45 PM 6

NX-SERIES HYBRID KEY SYSTEM

INSTALLATION SECTION

FIGURE 2-1 MOUNTING THE KSU

2.3 AC Power Selection ( See FIGURE 2-2 )

Before pluging in the KSU, set the AC power selection connector.

The Power board of each system has three power connectors. One is for 0V (Ground) and the rest are for 110V/220V selection. The KSU has two lines; one black and the other sky-blue (or white); with a pink power connection jack.

Verify the AC voltage and connect the sky-blue (or white) line to the 0V connector, and black to the AC power connector.

Connect the BLACK wire to 110VAC or 220VAC power(LIVE).

Connect the SKY-BLUE (or

white) wire to 0V (NEUTRAL)

Connect the GREEN-YELLOW (or

green) line to FRAME GROUND

FIGURE 2-2 AC POWER SELECTION

2 - 2

2INSTALL 1999.9.15 12:45 PM 8

NX-SERIES HYBRID KEY SYSTEM

INSTALLATION SECTION

3. INSTALLATION EXPANSION CARDS & OPTION BOARDS

Unpack and inspect each card before installing. Check for signs of physical damage. If any damage is detected, do not attempt to install.

3.1 NX-2TRK Card ( See FIGURE 3 - 1 )

Insert the NX-2TRK Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.

3.2 NX-4TRK Card ( See FIGURE 3 - 1 )

Insert the NX-4TRK Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.

3.3 NX-4KLI Card ( See FIGURE 3 - 2 )

Insert the NX-4KLI Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.

FIGURE 3-1 NX-2/4 TRK CARD

FIGURE 3-2 NX-4KLI CARD

3.4 NX-4SLI Card ( See FIGURE 3 - 3)

Insert the NX-4SLI Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.

3.5 NX-4OPX Card ( See FIGURE 3 - 4 )

Insert the NX-4OPX Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.

2 - 4

2INSTALL 1999.9.15 12:45 PM 10

NX-SERIES HYBRID KEY SYSTEM

INSTALLATION SECTION

3.8 NX-SMDR/R-MMC Board ( See FIGURE 3 - 7 )

Install the NX-SMDR/R-MMC board on the bottom of the base board.

3.9 NX-DPH/PAGING Board ( See FIGURE 3 - 8 )

Install the NX-DPH/PAGING board on the middle of the base board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 3-7 NX-SMDR/R-MMC BOARD

FIGURE 3-8 NX-DPH/PAGING BOARD

3.10 NX-MPD Board ( See FIGURE 3 - 9 )

Install the NX-MPD board on the bottom of the base board.

3.11 NX-PRS Board ( See FIGURE 3 - 10 )

Install the NX-PRS board on the bottom of the base board.

FIGURE 3-9 NX-MPD BOARD

FIGURE 3-10 NX-PRS BOARD

2 - 6

2INSTALL 1999.9.15 12:45 PM 12

NX-SERIES HYBRID KEY SYSTEM

INSTALLATION SECTION

3.13.2 NX-820 SYSTEM ( See FIGURE 3-13)

NX-820 system can have up to three expansion cards under the base board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS option boards are installed on the surface of Base board.

NX-MPD or NX-PRS Board.

NX-820 system has two NX-DPH/PAGING Board connectors.

 

 

SUPPORT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NX-SMDR/R-MMC

 

 

 

 

 

 

Board

 

 

 

 

 

 

 

 

 

 

 

 

 

NX-820 Base Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MDF Cards

 

 

 

 

 

 

 

 

 

Three Expansion Cards in any slot. Push

 

 

 

 

 

 

 

 

 

 

firmly to ensure that it is fully inserted into the

 

 

 

 

 

back plane connector on the connection

 

 

 

 

 

board.

 

 

 

 

 

 

 

 

 

 

FIGURE 3-13 INSTALLING EXPANSION CARD & OPTION B’D FOR NX-820

3.13.3 NX-1232 SYSTEM ( See FIGURE 3-14 )

NX-1232 system can have up to three expansion cards under the base board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS option boards are installed on the surface of Base board.

NX-MPD or NX-PRS Board.

NX-1232 system has four NX-DPH/PAGING Board connectors.

SUPPORT

NX-SMDR/R-MMC

Board

NX-1232 Base Board

Three Expansion Cards in any slot. Push MDF Cards firmly to ensure that it is fully inserted into the

back plane connector on the connection board.

FIGURE 3-14 INSTALLING EXPANSION CARD & OPTION B’D FOR NX-1232

2 - 8

2INSTALL 1999.9.15 12:45 PM 14

NX-SERIES HYBRID KEY SYSTEM

INSTALLATION SECTION

50 PIN CHAMP

CONNECTOR

 

P1

 

 

 

 

 

 

 

 

 

 

PIN NO.

COLOR

MDFA-C

FUNCTION

1

BL-W

R1

1

C.O.1

TIP

26

W-BL

R2

1

 

RING

 

 

 

 

 

 

2

O-W

R1

2

C.O.2

TIP

27

W-O

R2

2

 

RING

 

 

 

 

 

 

3

GN-W

R1

3

C.O.3

TIP

28

W-GN

R2

3

 

RING

4

BR-W

R1

4

RESERVED

29

W-BR

R2

4

 

 

 

 

 

 

 

 

5

S-W

X

 

NC

30

W-S

 

 

 

 

 

 

 

 

 

 

 

6

BL-R

R1

5

STN1

L1

31

R-BL

R2

5

 

L2

 

 

 

 

 

 

7

O-R

R1

6

STN1

D+

32

R-O

R2

6

 

D-

 

 

 

 

 

 

8

GR-R

R1

7

STN2

L1

33

R-GR

R2

7

 

L2

 

 

 

 

 

 

9

BR-R

R1

8

STN2

D+

34

R-BR

R2

8

 

D-

 

 

 

 

 

 

10

S-R

R1

9

STN3

L1

35

R-S

R2

9

 

L2

 

 

 

 

 

 

11

BL-BK

R1

10

STN3

D+

36

BK-BL

R2

10

 

D-

 

 

 

 

 

 

12

O-BK

R1

11

STN4

L1

37

BK-O

R2

11

 

L2

 

 

 

 

 

 

13

GR-BK

R1

12

STN4

D+

38

BK-GR

R2

12

 

D-

 

 

 

 

 

 

14

BR-BK

R1

13

STN5

L1

39

BK-BR

R2

13

 

L2

15

S-BK

R1

14

STN5

D+

40

BK-S

R2

14

 

D-

 

 

 

 

 

 

16

BL-Y

R1

15

STN6

L1

41

Y-BL

R2

15

 

L2

 

 

 

 

 

 

17

S-Y

R1

16

STN6

D+

42

Y-S

R2

16

 

D-

 

 

 

 

 

 

18

GR-Y

R1

17

STN7

L1

43

Y-GR

R2

17

 

L2

 

 

 

 

 

 

19

BR-Y

R1

18

STN7

D+

44

Y-BR

R2

18

 

D-

 

 

 

 

 

 

20

S-Y

R1

19

STN8

L1

45

Y-S

R2

19

 

L2

21

BL-VL

R1

20

STN8

D+

46

VL-BL

R2

20

 

D-

 

 

 

 

 

 

22

O-VL

X

 

NC

 

47

VL-O

 

 

 

 

 

 

 

 

 

 

 

 

23

GR-VL

X

 

NC

 

48

VL-GR

 

 

 

 

 

 

 

 

 

 

 

 

24

BR-VL

X

 

NC

 

49

VL-BR

 

 

 

 

 

 

 

 

 

 

 

 

25

S-VL

X

 

NC

 

50

VL-S

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 4-1 MDFA-C CONNECTIONS FOR NX-308

2 - 10

2INSTALL 1999.9.15 12:45 PM 16

NX-SERIES HYBRID KEY SYSTEM

INSTALLATION SECTION

50 PIN CHAMP

CONNECTOR

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN NO.

COLOR

MDFB-C

FUNCTION

 

1

BL-W

R1

1

C.O.1

TIP

 

26

W-BL

R2

1

 

RING

 

2

O-W

R1

2

C.O.2

TIP

 

27

W-O

R2

2

 

RING

 

3

GN-W

R1

3

C.O.3

TIP

 

28

W-GN

R2

3

 

RING

 

4

BR-W

R1

4

C.O.4

TIP

 

29

W-BR

R2

4

 

RING

 

5

S-W

X

 

NC

 

 

30

W-S

 

 

 

 

 

 

 

 

6

BL-R

R1

1

STN1

L1

 

31

R-BL

R2

1

 

L2

 

7

O-R

R1

2

STN1

D+

 

32

R-O

R2

2

 

D-

 

8

GR-R

R1

3

STN2

L1

 

33

R-GR

R2

3

 

L2

 

 

 

 

 

 

 

 

9

BR-R

R1

4

STN2

D+

 

34

R-BR

R2

4

 

D-

 

10

S-R

R1

5

STN3

L1

 

35

R-S

R2

5

 

L2

 

11

BL-BK

R1

6

STN3

D+

 

36

BK-BL

R2

6

 

D-

 

12

O-BK

R1

7

STN4

L1

 

37

BK-O

R2

7

 

L2

 

13

GR-BK

R1

8

STN4

D+

 

38

BK-GR

R2

8

 

D-

 

14

BR-BK

R1

9

STN5

L1

 

39

BK-BR

R2

9

 

L2

 

15

S-BK

R1

10

STN5

D+

 

40

BK-S

R2

10

 

D-

 

16

BL-Y

R1

11

STN6

L1

 

41

Y-BL

R2

11

 

L2

 

17

S-Y

R1

12

STN6

D+

 

42

Y-S

R2

12

 

D-

 

18

GR-Y

R1

13

STN7

L1

 

43

Y-GR

R2

13

 

L2

 

19

BR-Y

R1

14

STN7

D+

 

44

Y-BR

R2

14

 

D-

 

20

S-Y

R1

15

STN8

L1

 

45

Y-S

R2

15

 

L2

 

21

BL-VL

R1

16

STN8

D+

 

46

VL-BL

R2

16

 

D-

 

22

O-VL

R1

17

STN9

L1

 

47

VL-O

R2

17

 

L2

 

23

GR-VL

R1

18

STN10 L1

 

48

VL-GR

R2

18

 

L2

 

24

BR-VL

R1

19

STN11 L1

 

49

VL-BR

R2

19

 

L2

 

25

S-VL

R1

20

STN12 L1

 

50

VL-S

R2

20

 

L2

 

 

 

 

 

 

 

 

CLIP

CLIP 1

CLIP 2

FIGURE 4-3 MDFB-C CONNECTIONS FOR NX-820

2 - 12

2INSTALL 1999.9.15 12:45 PM 18

NX-SERIES HYBRID KEY SYSTEM

INSTALLATION SECTION

50 PIN CHAMP

 

 

 

 

 

 

 

CONNECTOR

 

P1

 

 

 

P2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN NO.

COLOR

CLIP 1

FUNCTION

CLIP 2

FUNCTION

1

BL-W

R1 1

C.O.1

TIP

R1

1

STN5

L1

26

W-BL

R2 1

RING

R2

1

 

L2

2

O-W

R1 2

C.O.2

TIP

R1

2

STN5

D+

27

W-O

R2 2

 

RING

R2

2

 

D-

3

GN-W

R1 3

C.O.3

TIP

R1

3

STN6

L1

28

W-GN

R2 3

 

RING

R2

3

 

L2

4

BR-W

R1 4

C.O.4

TIP

R1

4

STN6

D+

29

W-BR

R2 4

 

RING

R2

4

 

D-

5

S-W

R1 5

C.O.5

TIP

R1

5

STN7

L1

30

W-S

R2 5

 

RING

R2

5

 

L2

6

BL-R

R1 6

C.O.6

TIP

R1

6

STN7

D+

31

R-BL

R2 6

 

RING

R2

6

 

D-

7

O-R

R1 7

C.O.7

TIP

R1

7

STN8

L1

32

R-O

R2 7

 

RING

R2

7

 

L2

8

GR-R

R1 8

C.O.8

TIP

R1

8

STN8

D+

33

R-GR

R2 8

 

RING

R2

8

 

D-

 

 

 

 

 

 

 

 

 

9

BR-R

R1 9

NC

 

R1

9

NC

 

34

R-BR

R2 9

 

R2

9

 

 

 

 

 

10

S-R

R1 10

NC

 

R1

10

NC

 

35

R-S

R2 10

 

R2

10

 

 

 

 

 

11

BL-BK

R1 11

NC

 

R1

11

NC

 

36

BK-BL

R2 11

 

R2

11

 

 

 

 

 

12

O-BK

R1 12

NC

 

R1

12

NC

 

37

BK-O

R2 12

 

R2

12

 

 

 

 

 

13

GR-BK

R1 13

STN1

L1

R1

13

STN9

L1

38

BK-GR

R2 13

 

L2

R2

13

 

L2

14

BR-BK

R1 14

STN1

D+

R1

14

STN10

L1

39

BK-BR

R2 14

 

D-

R2

14

 

L2

15

S-BK

R1 15

STN2

L1

R1

15

STN11

L1

40

BK-S

R2 15

 

L2

R2

15

 

L2

16

BL-Y

R1 16

STN2

D+

R1

16

STN12

L1

41

Y-BL

R2 16

 

D-

R2

16

 

L2

17

S-Y

R1 17

STN3

L1

R1

17

STN13

L1

42

Y-S

R2 17

 

L2

R2

17

 

L2

18

GR-Y

R1 18

STN3

D+

R1

18

STN14

L1

43

Y-GR

R2 18

 

D-

R2

18

 

L2

19

BR-Y

R1 19

STN4

L1

R1

19

STN15

L1

44

Y-BR

R2 19

 

L2

R2

19

 

L2

20

S-Y

R1 20

STN4

D+

R1

20

STN16

L1

45

Y-S

R2 20

 

D-

R2

20

 

L2

21

BL-VL

X

NC

 

X

NC

46

VL-BL

 

 

 

 

 

 

 

 

22

O-VL

X

 

 

X

 

47

VL-O

 

 

 

 

 

 

 

 

 

 

23

GR-VL

X

 

 

X

 

48

VL-GR

 

 

 

 

 

 

 

 

 

 

24

BR-VL

X

 

 

X

 

49

VL-BR

 

 

 

 

 

 

 

 

 

 

25

S-VL

X

 

 

X

 

50

VL-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 4-5 MDFC-C CONNECTIONS FOR NX-1232

2 - 14

2INSTALL 1999.9.15 12:45 PM 20

NX-SERIES HYBRID KEY SYSTEM

INSTALLATION SECTION

50 PIN CHAMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTOR

 

 

2 TRK

4TRK

4KLI

4 SLI

 

8 KLI

 

8 SLI

 

4 OPX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN NO.

COLOR

MDFD-M

FUNCTION

FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION

1

BL-W

R1

1

C.O.1

TIP

C.O.1 TIP

STN1

L1

STN1

L1

STN1

L1

STN1

L1

STN1

L1

26

W-BL

R2

1

RING

RING

 

L2

 

L2

 

L2

 

L2

 

L2

2

O-W

R1

2

RESERVED

RESERVED

STN1

D+

RESERVED

STN1

D+

RESERVED RESERVED

27

W-O

R2

2

 

D-

 

D-

3

GN-W

R1

3

C.O.2

TIP

C.O.2 TIP

STN2

L1

STN2

L1

STN2

L1

STN2

L1

STN2

L1

28

W-GN

R2

3

RING

RING

 

L2

 

L2

 

L2

 

L2

 

L2

4

BR-W

R1

4

RESERVED

RESERVED

STN2

D+

RESERVED

STN2

D+

RESERVED RESERVED

29

W-BR

R2

4

 

 

 

 

D-

 

 

 

D-

 

 

 

 

5

S-W

R1

5

 

C.O.3 TIP

STN3

L1

STN3

L1

STN3

L1

STN3

L1

STN3

L1

30

W-S

R2

5

 

RING

 

L2

 

L2

 

L2

 

L2

 

L2

 

 

 

 

 

 

 

6

BL-R

R1

6

 

RESERVED

STN3

D+

RESERVED

STN3

D+

RESERVED RESERVED

31

R-BL

R2

6

 

 

 

 

D-

 

 

 

D-

 

 

 

 

7

O-R

R1

7

 

C.O.4 TIP

STN4

L1

STN4

L1

STN4

L1

STN4

L1

STN4

L1

32

R-O

R2

7

 

RING

 

L2

 

L2

 

L2

 

L2

 

L2

 

 

 

 

 

 

 

8

GR-R

R1

8

 

RESERVED

STN4

D+

RESERVED

STN4

D+

RESERVED RESERVED

33

R-GR

R2

8

 

 

 

 

D-

 

 

 

D-

 

 

 

 

9

BR-R

R1

9

 

RESERVED

 

STN5

L1

STN5

L1

 

34

R-BR

R2

9

 

 

 

L2

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

10

S-R

R1 10

 

 

 

STN5

D+

RESERVED

 

35

R-S

R2 10

 

 

 

 

 

 

 

 

D-

 

 

 

 

11

BL-BK

R1 11

 

 

 

STN6

L1

STN6

L1

 

36

BK-BL

R2 11

 

 

 

 

L2

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

12

O-BK

R1 12

 

 

 

STN6

D+

RESERVED

 

37

BK-O

R2 12

 

 

 

 

 

 

 

 

D-

 

 

 

 

13

GR-BK

R1 13

 

 

 

STN7

L1

STN7

L1

 

38

BK-GR

R2 13

 

 

 

 

L2

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

14

BR-BK

R1 14

 

 

 

STN7

D+

RESERVED

 

39

BK-BR

R2 14

 

 

 

 

 

 

 

 

D-

 

 

 

 

15

S-BK

R1 15

 

 

 

STN8

L1

STN8

L1

 

40

BK-S

R2 15

 

 

 

 

L2

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

16

BL-Y

R1 16

 

 

 

STN8

D+

RESERVED

 

41

Y-BL

R2 16

 

 

 

 

 

 

 

 

D-

 

 

 

 

17

S-Y

X

 

NC

NC

NC

 

NC

 

NC

NC

 

NC

 

42

Y-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

GR-Y

X

 

 

 

 

 

 

 

43

Y-GR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

BR-Y

X

 

 

 

 

 

 

 

44

Y-BR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

S-Y

X

 

 

 

 

 

 

 

45

Y-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

BL-VL

X

 

 

 

 

 

 

 

46

VL-BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

O-VL

X

 

 

 

 

 

 

 

47

VL-O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

GR-VL

X

 

 

 

 

 

 

 

48

VL-GR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

BR-VL

X

 

 

 

 

 

 

 

49

VL-BR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

S-VL

X

 

 

 

 

 

 

 

50

VL-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 4-7 MDFD-C CONNECTIONS(EXPANSION CARD)