1999.9.15 12:40 PM 1
NX-SERIES
Technical Manual
NX-308
NX-820
NX-1232
0preface 1999.9.15 12:46 PM 1
PUBLICATION INFORMATION
SAMSUNG ELECTRONICS Co. reserves the right to revise information in this publication for any reason without prior notice.
SAMSUNG ELECTRONICS Co.
also reserves the right to make changes in equipment design or components as engineering and manufacturing may warrant without prior notice .
COPYRIGHT 1997 SAMSUNG ELECTRONICS Co.
All rights reserved. No part of this manual may be reproduced in any form or by any means --- graphic, electronic or mechanical, including recording, taping, photocopying or information retrieval systems --- without express written permission of the publisher of this material.
0preface 1999.9.15 12:46 PM 2
0preface 1999.9.15 12:46 PM 3
NX-SERIES
NX-308 NX-820 NX-1232
ELECTRONIC KEY/HYBRID
TELEPHONE SYSTEM
TECHNICAL MANUAL
INCLUDES :
GENERAL DESCRIPTION SECTION
INSTALLATION SECTION
FEATURE SECTION
PROGRAMMING SECTION
APPENDIX SECTION
BACK-UP DATA SHEETS
0preface 1999.9.15 12:46 PM 4
1GENERAL 1999.9.15 12:46 PM 1
GENERAL DESCRIPTION
SECTION
1GENERAL 1999.9.15 12:46 PM 2
1GENERAL 1999.9.15 12:46 PM 3
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
TABLE OF CONTENTS
GENERAL DESCRIPTION
NX-SERIES GENERAL SYSTEM DIAGRAM . . . . . . . . . . . . . . . . . 1-1
1. SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.1 NX-308 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.2 NX-820 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.3 NX-1232 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
2. NX-SERIES LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2.1 TOP VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2.2 SIDE VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
3. SYSTEM CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
3.1 NX-308 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 3.2 NX-820 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 3.3 NX-1232 SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
4. HARDWARE DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
4.1 KSU (Key Service Unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 4.2 EXPANSION CARDS & OPTION BOARDS . . . . . . . . . . . . . . . 1-6 4.3 STATION EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
5. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
5.1 ELECTRICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . 1-8 5.2 DIMENSIONS AND WEIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1GENERAL 1999.9.15 12:46 PM 4
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
5.3 ENVIRONMENTAL LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . 1-8 5.4 CABLE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 5.5 SYSTEM TONES AND RINGS . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 5.6 KEYSET LED INDICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
1GENERAL 1999.9.15 12:46 PM 5
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
NX-SERIES GENERAL SYSTEM DIAGRAM
1 - 1
1GENERAL 1999.9.15 12:46 PM 6
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
1. SYSTEM OVERVIEW
The NX-series hybrid key system accomodates three kinds of Key Station:
NX-308, NX-820 and NX-1232.
1.1 NX-308 SYSTEM
The NX-308, with a maximum capacity of three telephone C.O. lines and eight stations, is an analog telephone system designed for the small-sized business.
A powerful HM64180R1 digital microprocessor controls all speech paths and system functions. The operating program with default memory is stored in nonvolatile ROM 27C020. Customer data is stored in RAM 62256 and is protected for up to seven continuous days' loss of system power by a Ni-Cd battery. When AC power is restored, the Ni-Cd battery is recharged automatically.
1.2 NX-820 SYSTEM
Designed for small to medium-sized businesses, the NX-820 is an analog telephone system featuring a maximum capacity of forty (40) ports, made up of the combined total of C.O. telephone lines and stations, permitting various configurations. Comprised of a Key Service Unit, expansion boards, electronic keysets and conventional single line telephones, the NX-820 offers small or medium-sized business users flexible control of telephone communications. A powerful HM64180R1 digital microprocessor controls all speech paths and system functions. The operating program with default memory is stored in non-volatile ROM 27C020. Customer data is stored in RAM 681000, and is protected for up to seven continuous days' loss of system power by a Ni-Cd battery. When AC power is restored, the Ni-Cd battery is recharged automatically.
1.3 NX-1232 SYSTEM
The NX-1232 is an analog telephone system designed for small to medium-sized business. The NX-1232 system has a maximum capacity of forty eight (48) ports, made up of the combined total of C.O. telephone lines and stations, permitting various configurations. Comprised of a Key Service Unit, expansion boards, electronic keysets and conventional single line telephones, the NX-1232 system offers small or medium-sized business users flexible control of telephone communications. A powerful HM64180R1 digital microprocessor controls all speech paths and system functions. The operating program with default memory is stored in non-volatile ROM 27C020. Customer data is stored in RAM 681000, and is protected for up to seven continuous days' loss of system power by a Ni-Cd battery. When AC power is restored, the Ni-Cd battery is recharged automatically.
1 - 2
1GENERAL 1999.9.15 12:46 PM 7
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
2.NX-SERIES LAYOUT
2.1TOP VIEW
“POWER” LED
“MONITOR” LED “IDLE” LCD
2.2 SIDE VIEW
MDF Cable Path
External Battery Connector
Fuse Holder
Power Switch
Power Cable
1 - 3
1GENERAL 1999.9.15 12:46 PM 8
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
3. SYSTEM CONFIGURATION
3.1 NX-308 SYSTEM
The basic KSU (Key Service Unit) comes equipped to operate three telephone lines and eight stations. Station #1 is assigned to be used with a keyset and stations #2 through #8 are assigned as keysets or single-line telephones.
The NX-SMDR/R-MMC board is the SMDR and REMOTE MMC serial interface, and the NX-DPH/PAGING board is the door phone and external paging interface. These optional boards can be installed on the base board
3.2 NX-820 SYSTEM
The basic KSU (Key Service Unit) comes equipped to operate four telephone lines and twelve stations. Stations #1 through #4 are assigned to be used with keysets and stations #5 through #12 are assigned for single-line telephones. The NX-820 system accomodates several kinds of expansion card. The NX-2TRK, NX-4TRK, NX-4KLI, NX-4SLI, NX-4OPX, NX-8KLI and NX-8SLI cards may be installed in any of the three expansion slots. By combining these cards, the NX-820 system can be increased to its maximum capacity of forty ports. Optionally, the NX-SMDR/R-MMC, NXDPH/PAGING, NX-MPD and NX-PRS board can be installed on the base board. The NX-SMDR/R-MMC board is the SMDR and REMOTE MMC serial interface, the NX-DPH/PAGING board is the door phone and external paging interface and the NX-MPD, NX-PRS board are interface for calculating call cost.
But, maximum keyphone part is restricted to twenty four(24) ports although three NX-8KLI cards are used.
16
12
8
4
4 |
8 |
12 |
20 |
28 |
36 |
No. of Stations
Basic KSU
Basic KSU, one 8 SLI (or 8 KLI) Board and one 4 TRK Card
Basic KSU, one 8 SLI (or 8 KLI) Board and two 4 TRK Cards
Basic KSU and three 4 TRK Cards
Basic KSU, two 8 SLI (or 8 KLI) Boards and one 4 TRK Cards
Basic KSU and three 8 SLI (or 8 KLI) Cards
1 - 4
1GENERAL 1999.9.15 12:46 PM 9
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
3.3 NX-1232 SYSTEM
The basic KSU (Key Service Unit) comes equipped to operate eight telephone lines and sixteen stations. Stations #1 through #8 are assigned to be used with keysets or single line telephones, and stations #9 through #16 are assigned for single line telephones. The NX-1232 system accepts several kinds of expansion cards. The NX-2TRK, NX-4TRK, NX-4KLI, NX-4SLI, NX-4OPX, NX-8KLI, NX8SLI cards can be installed in any of the three expansion slots. By combining these cards, the NX-1232 system can be increased to its maximum capacity of forty eight ports.
Optionally, the NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS board can be installed on the base board. The NX-SMDR/R-MMC board is the SMDR and REMOTE MMC serial interface, the NX-DPH/PAGING board is the door phone and external paging interface and the NX-MPD, NX-PRS board are interface for calculating call cost.
But, maximum keyphone part is restricted to twenty four(24) ports although three NX-8KLI cards are used.
20
16
12
8
8 |
16 |
24 |
32 |
40 |
No. of Stations
Basic KSU
Basic KSU, one 8 SLI (or 8 KLI) Board and one 4 TRK Card
Basic KSU, one 8 SLI (or 8 KLI) Board and two 4 TRK Cards
Basic KSU and three 4 TRK Cards
Basic KSU, two 8 SLI (or 8 KLI) Board and one 4 TRK Card
Basic KSU and three 8 SLI (or 8 KLI) Cards
1 - 5
1GENERAL 1999.9.15 12:46 PM 10
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
4. HARDWARE DESCRIPTION
4.1 KSU (Key Service Unit)
The KSU of the NX-series is a single cabinet, wall mounted, metal cased unit, containing the following:
●Power Supply
●Processing, switching, and customer memory for all ports.
●Internal music source and External music interface
●2 Power Failure Transfer
●Back-up Battery for memory protection
●Real Time Clock (RTC)
NX-308 SYSTEM |
|
NX-820 SYSTEM |
|
NX-1232 SYSTEM |
3 Trunk interfaces |
|
4 Trunk interfaces |
|
8 Trunk interfaces |
1 keyset, 7 Hybrid |
|
4 KTS and 8 SLT |
|
8 hybrid and 8 SLT |
station interfaces |
|
station interfaces |
|
station interfaces |
|
|
|
|
|
4.2EXPANSION CARDS & OPTION BOARDS
●NX-2TRK card provides two loop start trunk interfaces.
can be installed NX-820 and NX-1232 system.
●NX-4TRK card provides four loop start trunk interfaces.
can be installed NX-820 and NX-1232 system.
●NX-4KLI card provides four ports for keysets.
can be installed NX-820 and NX-1232 system.
●NX-4SLI card provides four SLI ports for industry standard single line telephones.
can be installed NX-820 and NX-1232 system.
●NX-4OPX card provides four OPX line port for industry standard single line
telephones and can be connected to PBX lines.
can be installed NX-820 and NX-1232 system.
●NX-8KLI card provides eight ports for keysets.
can be installed NX-820 and NX-1232 system.
●NX-8SLI card provides eight SLI port for industry standard single line telephones.
can be installed NX-820 and NX-1232 system.
●NX-MPD board provides two ports for metering pulse detection.
can be installed NX-820 and NX-1232 system.
●NX-PRS board provides two ports for polarity reverse signal detection.
can be installed NX-820 and NX-1232 system.
●NX-SMDR/R-MMC board provides two serial ports for SMDR and
REMOTE MMC.
can be installed all NX-SERIES system.
●NX-DPH/PAGING board provides two DOOR PHONE interface and one
EXTERNAL PAGING interface.can be installed all NX-SERIES system.
1 - 6
1GENERAL 1999.9.15 12:46 PM 11
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
4.3STATION EQUIPMENT
●Keyset with 24 buttons (NX-24E, NX-24B)
Built-in speakerphone
24 programmable soft keys (12 with tri-colored LEDs) and 10 fixed-function keys
UP/DOWN buttons for digital control of speaker, handset, and ringer volumes.
Four selectable ring tones per keyset
Deskor wallmount
NX-24E keyset with 16 character display
●Keyset with 12 buttons (NX-12E, NX-12B)
Built-in speakerphone
12 programmable soft keys (6 with tri-colored LEDs) and 10 fixed-function keys
UP/DOWN buttons for digital control of speaker, handset, and ringer volumes.
Four selectable ring tones per keyset
Deskor wallmount
NX-12E keyset with 16 character display
●Basic keyset with 6 buttons (NX-6B)
6 programmable soft keys and 10 fixed-function keys
UP/DOWN buttons for digital control of speaker, handset, and ringer volumes.
Four selectable ring tones per keyset
Deskor wallmount
●Add On Module (NX-AOM)
24 programmable soft keys
|
NX-24E |
|
NX-24B |
|
NX-12E |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NX-12B |
NX-6B |
NX-AOM |
1 - 7
1GENERAL 1999.9.15 12:46 PM 12
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
5. SPECIFICATIONS
5.1 ELECTRICAL SPECIFICATIONS
AC INPUT |
110/220 VAC, 50/60 Hz |
|
POWER |
NX-308 |
50 WATTS MAX |
CONSUMPTION |
NX-820 |
55 WATTS MAX |
|
NX-1232 |
80 WATTS MAX |
MAX CURRENT |
NX-308 |
0.22 AMP |
DRAW AT 220 VAC |
NX-820 |
0.29 AMP |
|
NX-1232 |
0.36 AMP |
RING GENERATOR |
AC 80 Vrms, 25 Hz |
|
BATTERY BACKUP |
24 VDC, 6 to 26Ah |
|
SUPPLY |
|
|
|
|
|
|
|
|
5.2 DIMENSIONS AND WEIGHTS
NX-308 |
530mm(H) x 348mm(W) x 102mm(D), |
4.9Kg |
KEY SERVICE UNIT NX-820 |
530mm(H) x 412mm(W) x 140mm(D), |
8.9Kg |
NX-1232 |
530mm(H) x 412mm(W) x 140mm(D), |
8.9Kg |
KEYSET |
214mm(H) x 206mm(W) x 150mm(D), |
1.1Kg |
AOM |
214mm(H) x 133mm(W) x 150mm(D), |
0.4Kg |
DOOR PHONE |
158mm(H) x 89mm(W) x 41mm(D), |
0.23Kg |
|
|
|
5.3 ENVIRONMENTAL LIMITATIONS
OPERATING TEMPERATURES |
0 - 45 (18 - 25 recommended) |
OPERATING HUMIDITY |
10% - 90% (non-condensing) |
|
|
5.4 CABLE REQUIREMENTS
ELECTRONIC SET |
2 pair twisted, Max. 400 m (24 AWG) |
SINGLE LINE TELEPHONE |
1 pair twisted, Max. 1 km (24 AWG) |
DOOR PHONE |
1 pair twisted, Max. 100 m (24 AWG) |
4 OPX B’D |
1 pair twisted, Max. 2Km (24 AWG) |
|
|
1 - 8
1GENERAL 1999.9.15 12:46 PM 13
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
5.5 SYSTEM TONES AND RINGS
DIAL TONE : A steady tone that indicates dialing may begin
CONTINUOUS
RING-BACK TONE : Indicates the station dialed is ringing.
400 ON / 200 OFF/
400 ON / 3000 OFF
BUSY TONE: Indicates the station dialed is busy.
500 ON / 500 OFF/
500 ON / 500 OFF
TRANSFER TONE: Indicates a call is being held and you can dial another party.
200 ON / 200 OFF /
200 ON / 200 OFF
ERROR TONE: Indicates you have done something incorrectly.
500 ON / 250 OFF /
500 ON / 250 OFF
CONFIRMATION TONE: Indicates you have correctly set or canceled a system feature.
100 ON / 100 OFF /
100 ON / 100 OFF
INTRUSION TONE: Indicates you have been barged-in on.
200 ON / 200 OFF /
200 ON / 5000 OFF
MESSAGE WAITING TONE: Indicates messages on SLT type station.
1000 ON / 250 OFF /
1000 ON / 250 OFF
CAMP-ON REMINDER TONE: Indicates a call transfered to you while you are busy.
1000 ON / 15000 OFF /
1000 ON / 15000 OFF
CO LINE RING: Indicates an outside call is ringing on your station.
1000 ON / 3000 OFF /
1000 ON / 3000 OFF
1 - 9
1GENERAL 1999.9.15 12:46 PM 14
NX-SERIES HYBRID KEY SYSTEM |
GENERAL DESCRIPTION SECTION |
STATION RING: Indicates an intercom call is ringing on your station.
400 ON / 200 OFF /
400 ON / 3000 OFF
DOORPHONE RING: Indicates a doorphone call is ringing on your station.
500 ON / 500 OFF /
500 ON / 500 OFF
ALARM RING: Indicates an alarm is ringing on your station.
500 ON / 500 OFF /
500 ON / 500 OFF
NOTE : The details may vary according to the regulations or customers reguest.
5.6 KEYSET LED INDICATIONS
CONDITION |
LED COLOR |
LED STATUS |
LINE IDLE |
— |
OFF |
LINE IN USE |
RED or GREEN |
STEADY ON |
RECALL |
AMBER |
FAST FLASH |
CALL ON HOLD |
RED or GREEN |
SLOW FLASH |
RINGING C.O. CALL |
RED or GREEN |
FAST FLASH |
RINGING INTERNAL CALL |
GREEN |
FAST FLASH |
DND INDICATION |
RED |
STEADY ON |
1 - 10
2INSTALL 1999.9.15 12:45 PM 1
INSTALLATION SECTION
2INSTALL 1999.9.15 12:45 PM 2
2INSTALL 1999.9.15 12:45 PM 4
NX-SERIES HYBRID KEY SYSTEM INSTALLATION SECTION
4 MDF CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-9 |
|
4.1 Clip type MDF Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-19 |
|
4.2 |
Using to Cable tie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-19 |
5. CONNECTING TELEPHONE LINES . . . . . . . . . . . . . . . . . . . . . |
2-20 |
|
5.1 |
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-20 |
5.2 |
LOOP START LINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-20 |
6. CONNECTING STATION EQUIPMENT . . . . . . . . . . . . . . . . . . |
2-20 |
|
6.1 CONNECTING KEYSET / AOM . . . . . . . . . . . . . . . . . . . . . . . . |
2-20 |
|
|
6.1.1 NX-308 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-20 |
|
6.1.2 NX-820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-21 |
|
6.1.3 NX-1232 Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-21 |
6.2 CONNECTING Single-Line Tel. . . . . . . . . . . . . . . . . . . . . . . . . 2-21 |
||
|
6.2.1 NX-308 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-22 |
|
6.2.2 NX-820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-22 |
|
6.2.3 NX-1232 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-22 |
7. CONNECTING OPTIONAL EQUIPMENT . . . . . . . . . . . . . . . . |
2-27 |
|
7.1 EXTERNAL MUSIC SOURCE . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-27 |
|
7.2 |
EXTERNAL PAGING FOR STANDARD . . . . . . . . . . . . . . . . . |
2-27 |
7.3 |
DOORPHONE AND DOOR LOCK RELEASE . . . . . . . . . . . . |
2-28 |
7.4 SMDR / REMOTE PROGRAMMING . . . . . . . . . . . . . . . . . . . . |
2-29 |
|
7.5 POWER FAILURE TRANSFER . . . . . . . . . . . . . . . . . . . . . . . . |
2-31 |
|
|
7.5.1 NX-308 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-31 |
|
7.5.2 NX-820 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-31 |
|
7.5.3 NX-1232 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-31 |
7.6 |
EXTERNAL BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-31 |
8. BEFORE POWER UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-32 |
|
9 INSTALLING TO KEYSET . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-33 |
9-1 CONNECTING TO LINE CORD . . . . . . . . . . . . . . . . . . . . . . . .2-33 9-2 WALL-MOUNTING A KEYSET . . . . . . . . . . . . . . . . . . . . . . . . .2-33 9-3 HOW TO REMOVE THE HANDSET CORD FROM THE HANDSET .2-34
2INSTALL 1999.9.15 12:45 PM 6
NX-SERIES HYBRID KEY SYSTEM |
INSTALLATION SECTION |
FIGURE 2-1 MOUNTING THE KSU
2.3 AC Power Selection ( See FIGURE 2-2 )
Before pluging in the KSU, set the AC power selection connector.
The Power board of each system has three power connectors. One is for 0V (Ground) and the rest are for 110V/220V selection. The KSU has two lines; one black and the other sky-blue (or white); with a pink power connection jack.
Verify the AC voltage and connect the sky-blue (or white) line to the 0V connector, and black to the AC power connector.
Connect the BLACK wire to 110VAC or 220VAC power(LIVE).
Connect the SKY-BLUE (or
white) wire to 0V (NEUTRAL)
Connect the GREEN-YELLOW (or
green) line to FRAME GROUND
FIGURE 2-2 AC POWER SELECTION
2 - 2
2INSTALL 1999.9.15 12:45 PM 8
NX-SERIES HYBRID KEY SYSTEM |
INSTALLATION SECTION |
3. INSTALLATION EXPANSION CARDS & OPTION BOARDS
Unpack and inspect each card before installing. Check for signs of physical damage. If any damage is detected, do not attempt to install.
3.1 NX-2TRK Card ( See FIGURE 3 - 1 )
Insert the NX-2TRK Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.
3.2 NX-4TRK Card ( See FIGURE 3 - 1 )
Insert the NX-4TRK Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.
3.3 NX-4KLI Card ( See FIGURE 3 - 2 )
Insert the NX-4KLI Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.
FIGURE 3-1 NX-2/4 TRK CARD |
FIGURE 3-2 NX-4KLI CARD |
3.4 NX-4SLI Card ( See FIGURE 3 - 3)
Insert the NX-4SLI Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.
3.5 NX-4OPX Card ( See FIGURE 3 - 4 )
Insert the NX-4OPX Card into any expansion slot. Push firmly to ensure that it is fully inserted into the backplane connector.
2 - 4
2INSTALL 1999.9.15 12:45 PM 10
NX-SERIES HYBRID KEY SYSTEM |
INSTALLATION SECTION |
3.8 NX-SMDR/R-MMC Board ( See FIGURE 3 - 7 )
Install the NX-SMDR/R-MMC board on the bottom of the base board.
3.9 NX-DPH/PAGING Board ( See FIGURE 3 - 8 )
Install the NX-DPH/PAGING board on the middle of the base board.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FIGURE 3-7 NX-SMDR/R-MMC BOARD |
FIGURE 3-8 NX-DPH/PAGING BOARD |
3.10 NX-MPD Board ( See FIGURE 3 - 9 )
Install the NX-MPD board on the bottom of the base board.
3.11 NX-PRS Board ( See FIGURE 3 - 10 )
Install the NX-PRS board on the bottom of the base board.
FIGURE 3-9 NX-MPD BOARD |
FIGURE 3-10 NX-PRS BOARD |
2 - 6
2INSTALL 1999.9.15 12:45 PM 12
NX-SERIES HYBRID KEY SYSTEM |
INSTALLATION SECTION |
3.13.2 NX-820 SYSTEM ( See FIGURE 3-13)
NX-820 system can have up to three expansion cards under the base board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS option boards are installed on the surface of Base board.
NX-MPD or NX-PRS Board.
NX-820 system has two NX-DPH/PAGING Board connectors.
|
|
SUPPORT |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NX-SMDR/R-MMC |
||
|
|
|
|
|
|
Board |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NX-820 Base Board |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MDF Cards |
|
|
|
|
|
|
|
|
|
|
Three Expansion Cards in any slot. Push |
|
|||||
|
|
|
|
|
||||
|
|
|
|
firmly to ensure that it is fully inserted into the |
|
|||
|
|
|
|
back plane connector on the connection |
|
|||
|
|
|
|
board. |
|
|||
|
|
|
|
|
|
|
|
|
FIGURE 3-13 INSTALLING EXPANSION CARD & OPTION B’D FOR NX-820
3.13.3 NX-1232 SYSTEM ( See FIGURE 3-14 )
NX-1232 system can have up to three expansion cards under the base board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS option boards are installed on the surface of Base board.
NX-MPD or NX-PRS Board.
NX-1232 system has four NX-DPH/PAGING Board connectors.
SUPPORT
NX-SMDR/R-MMC
Board
NX-1232 Base Board
Three Expansion Cards in any slot. Push MDF Cards firmly to ensure that it is fully inserted into the
back plane connector on the connection board.
FIGURE 3-14 INSTALLING EXPANSION CARD & OPTION B’D FOR NX-1232
2 - 8
2INSTALL 1999.9.15 12:45 PM 14
NX-SERIES HYBRID KEY SYSTEM |
INSTALLATION SECTION |
50 PIN CHAMP
CONNECTOR |
|
P1 |
|
|
||
|
|
|
|
|||
|
|
|
|
|||
PIN NO. |
COLOR |
MDFA-C |
FUNCTION |
|||
1 |
BL-W |
R1 |
1 |
C.O.1 |
TIP |
|
26 |
W-BL |
R2 |
1 |
|
RING |
|
|
|
|
|
|
|
|
2 |
O-W |
R1 |
2 |
C.O.2 |
TIP |
|
27 |
W-O |
R2 |
2 |
|
RING |
|
|
|
|
|
|
|
|
3 |
GN-W |
R1 |
3 |
C.O.3 |
TIP |
|
28 |
W-GN |
R2 |
3 |
|
RING |
|
4 |
BR-W |
R1 |
4 |
RESERVED |
||
29 |
W-BR |
R2 |
4 |
|||
|
|
|||||
|
|
|
|
|
|
|
5 |
S-W |
X |
|
NC |
||
30 |
W-S |
|
||||
|
|
|
|
|||
|
|
|
|
|
|
|
6 |
BL-R |
R1 |
5 |
STN1 |
L1 |
|
31 |
R-BL |
R2 |
5 |
|
L2 |
|
|
|
|
|
|
|
|
7 |
O-R |
R1 |
6 |
STN1 |
D+ |
|
32 |
R-O |
R2 |
6 |
|
D- |
|
|
|
|
|
|
|
|
8 |
GR-R |
R1 |
7 |
STN2 |
L1 |
|
33 |
R-GR |
R2 |
7 |
|
L2 |
|
|
|
|
|
|
|
|
9 |
BR-R |
R1 |
8 |
STN2 |
D+ |
|
34 |
R-BR |
R2 |
8 |
|
D- |
|
|
|
|
|
|
|
|
10 |
S-R |
R1 |
9 |
STN3 |
L1 |
|
35 |
R-S |
R2 |
9 |
|
L2 |
|
|
|
|
|
|
|
|
11 |
BL-BK |
R1 |
10 |
STN3 |
D+ |
|
36 |
BK-BL |
R2 |
10 |
|
D- |
|
|
|
|
|
|
|
|
12 |
O-BK |
R1 |
11 |
STN4 |
L1 |
|
37 |
BK-O |
R2 |
11 |
|
L2 |
|
|
|
|
|
|
|
|
13 |
GR-BK |
R1 |
12 |
STN4 |
D+ |
|
38 |
BK-GR |
R2 |
12 |
|
D- |
|
|
|
|
|
|
|
|
14 |
BR-BK |
R1 |
13 |
STN5 |
L1 |
|
39 |
BK-BR |
R2 |
13 |
|
L2 |
|
15 |
S-BK |
R1 |
14 |
STN5 |
D+ |
|
40 |
BK-S |
R2 |
14 |
|
D- |
|
|
|
|
|
|
|
|
16 |
BL-Y |
R1 |
15 |
STN6 |
L1 |
|
41 |
Y-BL |
R2 |
15 |
|
L2 |
|
|
|
|
|
|
|
|
17 |
S-Y |
R1 |
16 |
STN6 |
D+ |
|
42 |
Y-S |
R2 |
16 |
|
D- |
|
|
|
|
|
|
|
|
18 |
GR-Y |
R1 |
17 |
STN7 |
L1 |
|
43 |
Y-GR |
R2 |
17 |
|
L2 |
|
|
|
|
|
|
|
|
19 |
BR-Y |
R1 |
18 |
STN7 |
D+ |
|
44 |
Y-BR |
R2 |
18 |
|
D- |
|
|
|
|
|
|
|
|
20 |
S-Y |
R1 |
19 |
STN8 |
L1 |
|
45 |
Y-S |
R2 |
19 |
|
L2 |
|
21 |
BL-VL |
R1 |
20 |
STN8 |
D+ |
|
46 |
VL-BL |
R2 |
20 |
|
D- |
|
|
|
|
|
|
|
|
22 |
O-VL |
X |
|
NC |
|
|
47 |
VL-O |
|
|
|||
|
|
|
|
|||
|
|
|
|
|
|
|
23 |
GR-VL |
X |
|
NC |
|
|
48 |
VL-GR |
|
|
|||
|
|
|
|
|||
|
|
|
|
|
|
|
24 |
BR-VL |
X |
|
NC |
|
|
49 |
VL-BR |
|
|
|||
|
|
|
|
|||
|
|
|
|
|
|
|
25 |
S-VL |
X |
|
NC |
|
|
50 |
VL-S |
|
|
|||
|
|
|
|
|||
|
|
|
|
|
|
FIGURE 4-1 MDFA-C CONNECTIONS FOR NX-308
2 - 10
2INSTALL 1999.9.15 12:45 PM 16
NX-SERIES HYBRID KEY SYSTEM |
INSTALLATION SECTION |
50 PIN CHAMP
CONNECTOR |
|
P1 |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
||
PIN NO. |
COLOR |
MDFB-C |
FUNCTION |
|
||
1 |
BL-W |
R1 |
1 |
C.O.1 |
TIP |
|
26 |
W-BL |
R2 |
1 |
|
RING |
|
2 |
O-W |
R1 |
2 |
C.O.2 |
TIP |
|
27 |
W-O |
R2 |
2 |
|
RING |
|
3 |
GN-W |
R1 |
3 |
C.O.3 |
TIP |
|
28 |
W-GN |
R2 |
3 |
|
RING |
|
4 |
BR-W |
R1 |
4 |
C.O.4 |
TIP |
|
29 |
W-BR |
R2 |
4 |
|
RING |
|
5 |
S-W |
X |
|
NC |
|
|
30 |
W-S |
|
|
|
||
|
|
|
|
|
||
6 |
BL-R |
R1 |
1 |
STN1 |
L1 |
|
31 |
R-BL |
R2 |
1 |
|
L2 |
|
7 |
O-R |
R1 |
2 |
STN1 |
D+ |
|
32 |
R-O |
R2 |
2 |
|
D- |
|
8 |
GR-R |
R1 |
3 |
STN2 |
L1 |
|
33 |
R-GR |
R2 |
3 |
|
L2 |
|
|
|
|
|
|
|
|
9 |
BR-R |
R1 |
4 |
STN2 |
D+ |
|
34 |
R-BR |
R2 |
4 |
|
D- |
|
10 |
S-R |
R1 |
5 |
STN3 |
L1 |
|
35 |
R-S |
R2 |
5 |
|
L2 |
|
11 |
BL-BK |
R1 |
6 |
STN3 |
D+ |
|
36 |
BK-BL |
R2 |
6 |
|
D- |
|
12 |
O-BK |
R1 |
7 |
STN4 |
L1 |
|
37 |
BK-O |
R2 |
7 |
|
L2 |
|
13 |
GR-BK |
R1 |
8 |
STN4 |
D+ |
|
38 |
BK-GR |
R2 |
8 |
|
D- |
|
14 |
BR-BK |
R1 |
9 |
STN5 |
L1 |
|
39 |
BK-BR |
R2 |
9 |
|
L2 |
|
15 |
S-BK |
R1 |
10 |
STN5 |
D+ |
|
40 |
BK-S |
R2 |
10 |
|
D- |
|
16 |
BL-Y |
R1 |
11 |
STN6 |
L1 |
|
41 |
Y-BL |
R2 |
11 |
|
L2 |
|
17 |
S-Y |
R1 |
12 |
STN6 |
D+ |
|
42 |
Y-S |
R2 |
12 |
|
D- |
|
18 |
GR-Y |
R1 |
13 |
STN7 |
L1 |
|
43 |
Y-GR |
R2 |
13 |
|
L2 |
|
19 |
BR-Y |
R1 |
14 |
STN7 |
D+ |
|
44 |
Y-BR |
R2 |
14 |
|
D- |
|
20 |
S-Y |
R1 |
15 |
STN8 |
L1 |
|
45 |
Y-S |
R2 |
15 |
|
L2 |
|
21 |
BL-VL |
R1 |
16 |
STN8 |
D+ |
|
46 |
VL-BL |
R2 |
16 |
|
D- |
|
22 |
O-VL |
R1 |
17 |
STN9 |
L1 |
|
47 |
VL-O |
R2 |
17 |
|
L2 |
|
23 |
GR-VL |
R1 |
18 |
STN10 L1 |
|
|
48 |
VL-GR |
R2 |
18 |
|
L2 |
|
24 |
BR-VL |
R1 |
19 |
STN11 L1 |
|
|
49 |
VL-BR |
R2 |
19 |
|
L2 |
|
25 |
S-VL |
R1 |
20 |
STN12 L1 |
|
|
50 |
VL-S |
R2 |
20 |
|
L2 |
|
|
|
|
|
|
|
|
CLIP
CLIP 1
CLIP 2
FIGURE 4-3 MDFB-C CONNECTIONS FOR NX-820
2 - 12
2INSTALL 1999.9.15 12:45 PM 18
NX-SERIES HYBRID KEY SYSTEM |
INSTALLATION SECTION |
50 PIN CHAMP |
|
|
|
|
|
|
|
|
CONNECTOR |
|
P1 |
|
|
|
P2 |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|||
PIN NO. |
COLOR |
CLIP 1 |
FUNCTION |
CLIP 2 |
FUNCTION |
|||
1 |
BL-W |
R1 1 |
C.O.1 |
TIP |
R1 |
1 |
STN5 |
L1 |
26 |
W-BL |
R2 1 |
RING |
R2 |
1 |
|
L2 |
|
2 |
O-W |
R1 2 |
C.O.2 |
TIP |
R1 |
2 |
STN5 |
D+ |
27 |
W-O |
R2 2 |
|
RING |
R2 |
2 |
|
D- |
3 |
GN-W |
R1 3 |
C.O.3 |
TIP |
R1 |
3 |
STN6 |
L1 |
28 |
W-GN |
R2 3 |
|
RING |
R2 |
3 |
|
L2 |
4 |
BR-W |
R1 4 |
C.O.4 |
TIP |
R1 |
4 |
STN6 |
D+ |
29 |
W-BR |
R2 4 |
|
RING |
R2 |
4 |
|
D- |
5 |
S-W |
R1 5 |
C.O.5 |
TIP |
R1 |
5 |
STN7 |
L1 |
30 |
W-S |
R2 5 |
|
RING |
R2 |
5 |
|
L2 |
6 |
BL-R |
R1 6 |
C.O.6 |
TIP |
R1 |
6 |
STN7 |
D+ |
31 |
R-BL |
R2 6 |
|
RING |
R2 |
6 |
|
D- |
7 |
O-R |
R1 7 |
C.O.7 |
TIP |
R1 |
7 |
STN8 |
L1 |
32 |
R-O |
R2 7 |
|
RING |
R2 |
7 |
|
L2 |
8 |
GR-R |
R1 8 |
C.O.8 |
TIP |
R1 |
8 |
STN8 |
D+ |
33 |
R-GR |
R2 8 |
|
RING |
R2 |
8 |
|
D- |
|
|
|
|
|
|
|
|
|
9 |
BR-R |
R1 9 |
NC |
|
R1 |
9 |
NC |
|
34 |
R-BR |
R2 9 |
|
R2 |
9 |
|
||
|
|
|
|
|||||
10 |
S-R |
R1 10 |
NC |
|
R1 |
10 |
NC |
|
35 |
R-S |
R2 10 |
|
R2 |
10 |
|
||
|
|
|
|
|||||
11 |
BL-BK |
R1 11 |
NC |
|
R1 |
11 |
NC |
|
36 |
BK-BL |
R2 11 |
|
R2 |
11 |
|
||
|
|
|
|
|||||
12 |
O-BK |
R1 12 |
NC |
|
R1 |
12 |
NC |
|
37 |
BK-O |
R2 12 |
|
R2 |
12 |
|
||
|
|
|
|
|||||
13 |
GR-BK |
R1 13 |
STN1 |
L1 |
R1 |
13 |
STN9 |
L1 |
38 |
BK-GR |
R2 13 |
|
L2 |
R2 |
13 |
|
L2 |
14 |
BR-BK |
R1 14 |
STN1 |
D+ |
R1 |
14 |
STN10 |
L1 |
39 |
BK-BR |
R2 14 |
|
D- |
R2 |
14 |
|
L2 |
15 |
S-BK |
R1 15 |
STN2 |
L1 |
R1 |
15 |
STN11 |
L1 |
40 |
BK-S |
R2 15 |
|
L2 |
R2 |
15 |
|
L2 |
16 |
BL-Y |
R1 16 |
STN2 |
D+ |
R1 |
16 |
STN12 |
L1 |
41 |
Y-BL |
R2 16 |
|
D- |
R2 |
16 |
|
L2 |
17 |
S-Y |
R1 17 |
STN3 |
L1 |
R1 |
17 |
STN13 |
L1 |
42 |
Y-S |
R2 17 |
|
L2 |
R2 |
17 |
|
L2 |
18 |
GR-Y |
R1 18 |
STN3 |
D+ |
R1 |
18 |
STN14 |
L1 |
43 |
Y-GR |
R2 18 |
|
D- |
R2 |
18 |
|
L2 |
19 |
BR-Y |
R1 19 |
STN4 |
L1 |
R1 |
19 |
STN15 |
L1 |
44 |
Y-BR |
R2 19 |
|
L2 |
R2 |
19 |
|
L2 |
20 |
S-Y |
R1 20 |
STN4 |
D+ |
R1 |
20 |
STN16 |
L1 |
45 |
Y-S |
R2 20 |
|
D- |
R2 |
20 |
|
L2 |
21 |
BL-VL |
X |
NC |
|
X |
NC |
||
46 |
VL-BL |
|
||||||
|
|
|
|
|
|
|
||
22 |
O-VL |
X |
” |
|
|
X |
” |
|
47 |
VL-O |
|
|
|
||||
|
|
|
|
|
|
|
||
23 |
GR-VL |
X |
” |
|
|
X |
” |
|
48 |
VL-GR |
|
|
|
||||
|
|
|
|
|
|
|
||
24 |
BR-VL |
X |
” |
|
|
X |
” |
|
49 |
VL-BR |
|
|
|
||||
|
|
|
|
|
|
|
||
25 |
S-VL |
X |
” |
|
|
X |
” |
|
50 |
VL-S |
|
|
|
||||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
FIGURE 4-5 MDFC-C CONNECTIONS FOR NX-1232
2 - 14
2INSTALL 1999.9.15 12:45 PM 20
NX-SERIES HYBRID KEY SYSTEM |
INSTALLATION SECTION |
50 PIN CHAMP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CONNECTOR |
|
|
2 TRK |
4TRK |
4KLI |
4 SLI |
|
8 KLI |
|
8 SLI |
|
4 OPX |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
||||||||||||
PIN NO. |
COLOR |
MDFD-M |
FUNCTION |
FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION |
||||||||||||
1 |
BL-W |
R1 |
1 |
C.O.1 |
TIP |
C.O.1 TIP |
STN1 |
L1 |
STN1 |
L1 |
STN1 |
L1 |
STN1 |
L1 |
STN1 |
L1 |
26 |
W-BL |
R2 |
1 |
RING |
RING |
|
L2 |
|
L2 |
|
L2 |
|
L2 |
|
L2 |
|
2 |
O-W |
R1 |
2 |
RESERVED |
RESERVED |
STN1 |
D+ |
RESERVED |
STN1 |
D+ |
RESERVED RESERVED |
|||||
27 |
W-O |
R2 |
2 |
|
D- |
|
D- |
|||||||||
3 |
GN-W |
R1 |
3 |
C.O.2 |
TIP |
C.O.2 TIP |
STN2 |
L1 |
STN2 |
L1 |
STN2 |
L1 |
STN2 |
L1 |
STN2 |
L1 |
28 |
W-GN |
R2 |
3 |
RING |
RING |
|
L2 |
|
L2 |
|
L2 |
|
L2 |
|
L2 |
|
4 |
BR-W |
R1 |
4 |
RESERVED |
RESERVED |
STN2 |
D+ |
RESERVED |
STN2 |
D+ |
RESERVED RESERVED |
|||||
29 |
W-BR |
R2 |
4 |
|
|
|
|
D- |
|
|
|
D- |
|
|
|
|
5 |
S-W |
R1 |
5 |
” |
|
C.O.3 TIP |
STN3 |
L1 |
STN3 |
L1 |
STN3 |
L1 |
STN3 |
L1 |
STN3 |
L1 |
30 |
W-S |
R2 |
5 |
|
RING |
|
L2 |
|
L2 |
|
L2 |
|
L2 |
|
L2 |
|
|
|
|
|
|
|
|
||||||||||
6 |
BL-R |
R1 |
6 |
” |
|
RESERVED |
STN3 |
D+ |
RESERVED |
STN3 |
D+ |
RESERVED RESERVED |
||||
31 |
R-BL |
R2 |
6 |
|
|
|
|
D- |
|
|
|
D- |
|
|
|
|
7 |
O-R |
R1 |
7 |
” |
|
C.O.4 TIP |
STN4 |
L1 |
STN4 |
L1 |
STN4 |
L1 |
STN4 |
L1 |
STN4 |
L1 |
32 |
R-O |
R2 |
7 |
|
RING |
|
L2 |
|
L2 |
|
L2 |
|
L2 |
|
L2 |
|
|
|
|
|
|
|
|
||||||||||
8 |
GR-R |
R1 |
8 |
” |
|
RESERVED |
STN4 |
D+ |
RESERVED |
STN4 |
D+ |
RESERVED RESERVED |
||||
33 |
R-GR |
R2 |
8 |
|
|
|
|
D- |
|
|
|
D- |
|
|
|
|
9 |
BR-R |
R1 |
9 |
” |
|
” |
RESERVED |
” |
|
STN5 |
L1 |
STN5 |
L1 |
” |
|
|
34 |
R-BR |
R2 |
9 |
|
|
|
L2 |
|
L2 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
||||||
10 |
S-R |
R1 10 |
” |
|
” |
” |
|
” |
|
STN5 |
D+ |
RESERVED |
” |
|
||
35 |
R-S |
R2 10 |
|
|
|
|
|
|
|
|
D- |
|
|
|
|
|
11 |
BL-BK |
R1 11 |
” |
|
” |
” |
|
” |
|
STN6 |
L1 |
STN6 |
L1 |
” |
|
|
36 |
BK-BL |
R2 11 |
|
|
|
|
L2 |
|
L2 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
||||||
12 |
O-BK |
R1 12 |
” |
|
” |
” |
|
” |
|
STN6 |
D+ |
RESERVED |
” |
|
||
37 |
BK-O |
R2 12 |
|
|
|
|
|
|
|
|
D- |
|
|
|
|
|
13 |
GR-BK |
R1 13 |
” |
|
” |
” |
|
” |
|
STN7 |
L1 |
STN7 |
L1 |
” |
|
|
38 |
BK-GR |
R2 13 |
|
|
|
|
L2 |
|
L2 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
||||||
14 |
BR-BK |
R1 14 |
” |
|
” |
” |
|
” |
|
STN7 |
D+ |
RESERVED |
” |
|
||
39 |
BK-BR |
R2 14 |
|
|
|
|
|
|
|
|
D- |
|
|
|
|
|
15 |
S-BK |
R1 15 |
” |
|
” |
” |
|
” |
|
STN8 |
L1 |
STN8 |
L1 |
” |
|
|
40 |
BK-S |
R2 15 |
|
|
|
|
L2 |
|
L2 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
||||||
16 |
BL-Y |
R1 16 |
” |
|
” |
” |
|
” |
|
STN8 |
D+ |
RESERVED |
” |
|
||
41 |
Y-BL |
R2 16 |
|
|
|
|
|
|
|
|
D- |
|
|
|
|
|
17 |
S-Y |
X |
|
NC |
NC |
NC |
|
NC |
|
NC |
NC |
|
NC |
|
||
42 |
Y-S |
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
18 |
GR-Y |
X |
|
” |
|
” |
” |
|
” |
|
” |
|
” |
|
” |
|
43 |
Y-GR |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
19 |
BR-Y |
X |
|
” |
|
” |
” |
|
” |
|
” |
|
” |
|
” |
|
44 |
Y-BR |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
20 |
S-Y |
X |
|
” |
|
” |
” |
|
” |
|
” |
|
” |
|
” |
|
45 |
Y-S |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
21 |
BL-VL |
X |
|
” |
|
” |
” |
|
” |
|
” |
|
” |
|
” |
|
46 |
VL-BL |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
22 |
O-VL |
X |
|
” |
|
” |
” |
|
” |
|
” |
|
” |
|
” |
|
47 |
VL-O |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
23 |
GR-VL |
X |
|
” |
|
” |
” |
|
” |
|
” |
|
” |
|
” |
|
48 |
VL-GR |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
24 |
BR-VL |
X |
|
” |
|
” |
” |
|
” |
|
” |
|
” |
|
” |
|
49 |
VL-BR |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
25 |
S-VL |
X |
|
” |
|
” |
” |
|
” |
|
” |
|
” |
|
” |
|
50 |
VL-S |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FIGURE 4-7 MDFD-C CONNECTIONS(EXPANSION CARD)
2 - 16