E-4
Deciding the Installation Place
You should observe the following restrictions when you decide the installation place.
General
Do NOT install the air conditioner under the following conditions;
◆ Combustible gases
◆ Saline air
◆ Machine oil
◆ Sulfide gas
◆ Special environmental conditions
If you have no alternative place to install it, first consult your dealer or a qualified person.
Indoor Unit
◆ There must be no obstacles near the air inlet and outlet.
◆ Install the indoor unit on a surface that can support its weight.
◆ Choose a place where you can easily connect the pipes and cables to the outdoor unit.
The recommended length of the pipes and cables is 5 meters. The maximum length is ‘L’ meters.
◆ Leave sufficient space below the indoor unit to remove the filters easily.
◆ Maintain sufficient space around the indoor unit as seen in the picture on page 5.
◆ Make sure that the water dripping from the drain hose runs off correctly and safely.
◆ Install the indoor unit higher than 2.5m from the ground.
Outdoor Unit
◆ NEVER place the outdoor unit on its side or upside down. The compressor lubricating oil may run into the circuit and
damage the outdoor unit seriously.
◆ Choose a dry and sunny place avoiding direct sunlight or strong winds.
◆ Do not obstruct the passage.
◆ Avoid a place that may disturb your neighbor. A noise may occur from the outdoor unit and the discharged air may
run into the neighborhood.
◆ Choose a place where you can easily connect the pipes and cables to the indoor unit. The recommended length of
the pipes and cables is 5 meters. The maximum length is ‘L’ meters.
◆ Install the outdoor unit on a flat and stable surface. Otherwise it may slant and make some noise and vibration.
◆ Install the outdoor unit on a hard and even place that can support its weight.
◆ Place the outdoor unit so as to let the discharged air out properly.
◆ Maintain sufficient space around the outdoor unit as seen in the picture on page 5.
◆ When you install the outdoor unit at a height, you should firmly fix it in its place. The maximum height is ‘H’ meters.
◆ Make sure that the water dripping from the drain hose runs off correctly and safely.
◆ The air conditioner must be installed according to the national electrical rules.
◆ Max input power & current is measured according to IEC standard and input power &
current is measured according to ISO standard.
CCCCAAAAUUUUTTTTIIIIOOOONN
NN
PREPARING THE INSTALLATION