OPERATOR’S MANUAL

POWER USAGE METER

E49CM01

IMPORTANT SAFETY

INSTRUCTIONS

WARNING!

R e a d a n d u n d e r s ta n d a l l instructions. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury.

This product is for indoor use only.

Do not get the product wet. Do not use if this product is exposed to moisture.

Do not disassemble. This product has no user-serviceable parts.

As with all electrical devices, use caution when plugging and unplugging this unit into an outlet or plugging/unplugging other devices into this unit. Do not force this unit into an outlet. Do not force plugs into this outlet.

If required, use only UL/ETL approved extension cords with this product.

If this unit is used in a manner not specified by the manufacturer, the protection provided by this equipment may be impaired.

Do not overload the tool. It must be used for powering devices less than the product rating.

For use in grounded outlets only. Do not remove grounding prong from back of product.

Operate this product using only the AC power type listed in the product specifications.

Twoor three-prong plugs may be used with this product. Do not force a polarized plug (one prong larger than the other) into this product. Flip plug over and retry.

Save these instructions. Refer to them frequently and use them to instruct others who may use this product. If you loan someone this product, loan them these instructions also.

specifications

Ratings:

0.2 to 15 Amps max or 24 to 1800 watts max. @ 100-120V AC (50-60Hz)

Display Auto Off: 2 minutes

Input: 120V AC @60Hz

Output: 15 Amps Max 120V AC @60Hz

Operating Temperature:

32º to 104ºF (0º to 40 Cº)

Operating Humidity:

20% to 80% Relative Humidity

Operating Altitude:

Up to 6500 ft. (2000m)

Battery Requirement:

(2) LR44 Button Cells

Transient Voltage:1500V

Degree of Protection:

IP20 (Protected against solid objects up to 12 mm)

Pollution Degree: 2

Grounding:

Measurement Category: CAT III

OPERATION

USING THE POWER USAGE METER

See Figure 1.

Thepowerusagemetercalculatesthecostofpower usage by most electronic devices which plug into a 120 volt AC outlet.

Cost is determined by the rate per Kilowatt hour (kWh) charged by your local electric company. Call your electric company for rates, or check your most recent statement.

NOTE: The cost of operation is only calculated after the rate per kilowatt hour is programmed.

This product displays Amps, Kilowatt Hours, Watts, cost of operation, and the total price for the time period the device was connected.

Before first use, remove the plastic strip from the battery compartment on the back of unit.

Press and hold the Enter button (C) until the time display flashes.

The default setting is a 12 hour clock.

To set hours and minutes, press the Clock/timer button(A) or Center button (B).

Press Enter button (C) again to set the price per kilowatt hour (max. 0.99). Press the Clock/ timer and Center buttons (A) or (B) to change the amount in cents.

When you have input the time and price per kilowatt hour, press and hold the Enter button

(C) until the display stops flashing.

Plug the power usage meter into a standard, grounded wall outlet or UL/ETL approved, grounded 15 Amp capable extension cord.

Plug the device you wish to monitor into the power usage meter.

When the device is plugged into the power usage meter, it will begin displaying power used in Watts. This is the default setting.

• TotogglethedisplaybetweenKilowatthours,

Amps, and Watts, press the Center button

(B).

• Press to change to a 24-hour clock.

• Press again to change to the duration of time the device has been connected to the meter.

The display shows minutes from 1-59, then shows the time in hours. At 24 hours, the meter switches to time displayed in days.

Fig. 1

 

 

06:42PM

E

 

 

$ 19.85

A

 

 

 

B

 

 

 

D

 

VER

 

 

O

RESET

 

 

 

 

C

 

 

 

A- Clock/timer button

(Bouton « Clock/timer » (Horloge/chronomètre), Botón Reloj/cronómetro)

B- Center button (Bouton « Center » [Centre], Botón Centro)

C- Enter button (Bouton « Enter » [Entrée], Botón Entrar)

D- Overload indicator (Indicateur de surcharge, Indicador de sobrecarga)

E - LCD display (Afficheur ACL, Pantalla de LCD)

OPERATION

To display the cost per kilowatt hour, press the Enter button (C).

To toggle between Cost Per Day, Cost Per

Week, Cost Per Month, Cost Per Year, and Total Cost calculated so far, press the Center button (B).

The meter will continue to calculate cost until the device is unplugged. The information on the display will remain in memory until the meter is reset.

To reset the power usage meter, press the Clock/ timer and Enter buttons (A) and (C) at the same time, until the display shows all zeros.

NOTE: If you do not reset the meter to clear the memory, it will retain the most recent reading and add it to the next one.

The meter goes into Automatic Off mode after two minutes of inactivity. Pressing any button will bring the display back up.

OVERLOAD WARNING

If the electrical current going through the power usage meter exceeds 15 Amps, the overload indicator light (D) will come on. If this occurs, the power usage meter should not be used, and the device you are attempting to measure should be powered down and disconnected from the meter.

replacing the batterIES

See Figure 2.

The power usage meter uses two (2) LR44 button cell batteries to retain readings in memory. Estimated battery life is 4-6 months.

To replace the batteries:

Push on the two latches of the battery cover to remove it.

Remove the depleted batteries.

Install two new batteries as shown and push the cover back into place until it clicks to close.

Reset the unit as previously instructed in Using the Power Usage Meter.

cleaning

If the unit becomes dirty or dusty, unplug it from outlet. Unplug any attached devices. Wipe outside of product with a dry or lightly dampened rag only. Allow to dry completely prior to use. Do not use spray cleaners.

Fig. 2

WARRANTY

LIMITED TWO YEAR WARRANTY AND 30 DAY EXCHANGE POLICY

30-DAY EXCHANGE POLICY: During the first 30 days after date of purchasing this product, you may either request service under this warranty or you may exchange it by returning it with proof of purchase and all original equipment packaged with the original product to the dealer from which it was purchased. The replacement product will be covered by the limited warranty for the balance of the two year period from the date of the original purchase.

LIMITED TWO YEAR WARRANTY. This product is warranted against all defects in workmanship or materials for a period of two years from the date of purchase. The warranty on any accessories for this product, excluding batteries, is limited to 90 days from the date the accessory is purchased. To obtain warranty service, call Customer Service at 1-800-525-2579 for warranty return instructions. The product must be properly packaged and returned with all equipment that was included with the original product. When you request warranty service, you must also present proof of purchase documentation, which includes the date of purchase (for example, a receipt or a bill of sale). Defective products returned within the warranty period will be repaired or replaced, at our option, free of charge, within ninety (90) days or less. The cost of shipping the product to us is your responsibility. This warranty only covers defects arising under normal usage and does not cover any malfunction, failure or defects resulting from misuse, abuse, neglect, alteration, modification or unauthorized repairs. It applies only to the original purchaser at retail, and may not be transferred. One World Technologies, Inc. makes no warranties, representations or promises as to the quality or performance of this product other than those specifically stated in this warranty. Any implied warranties granted under state law, includingwarrantiesofmerchantabilityorfitnessfor a particular purpose, are limited to two years from the date of purchase. One World Technologies, Inc. is not responsible for direct, indirect, or incidental damages Some states do not allow limitations on how long an implied warranty lasts, or the exclusionorlimitationofincidentalorconsequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

one world TECHNOLOGIES, INC.

1428 Pearman Dairy Road, Anderson, SC 29625

Phone 1-800-525-2579 www.ryobitools.com

CUS

3189400

Ryobi® is a registered trademark of Ryobi Limited used under license.

Français

manuel d’utilisation

DISPOSITIF DE CALCUL DE LA CONSOMMATION D’ÉLECTRICITÉ E49CM01

instructions importantes concernant lA sécurité

AVERTISSEMENT !

LIRE ET VEILLER À BIEN COMPRENDRE TOUTES LES INSTRUCTIONS. Le nonrespect de toutes les instructions ci-dessous peut entraîner un choc électrique, un incendie et/ou des blessures graves.

Ce produit est conçu pour être utilisé uniquement à l’intérieur.

Ne pas mouiller le produit. Ne pas utiliser le produit s’il est exposé à l’humidité.

Ne pas désassembler le produit. Aucune de ses pièces ne peut être réparée par l’utilisateur.

Comme c’est le cas avec tous les dispositifs électriques, agir avec précaution au moment de brancher l’unité dans une prise et de l’en débrancher ou de brancher d’autres dispositifs dans cette unité et de les en débrancher. Ne pas brancher de force l’unité dans une prise. Ne pas forcer les fiches à s’insérer dans cette prise.

Au besoin, utiliser uniquement des cordons prolongateurs approuvés par Underwriters Laboratories, Inc. (UL) et Electrical Testing Laboratories (ETL) avec ce produit.

Si cette unité est utilisée d’une façon non conforme aux directives du fabricant, la protection fournie par cet équipement peut être détériorée.

Ne pas surcharger l’outil. Il doit être utilisé pour alimenter des dispositifs dotés d’une puissance inférieure à la sienne.

Compatible uniquement avec des prises mises à la terre. Ne pas retirer la branche de mise à la terre située au dos du produit.

Utiliser ce produit uniquement avec le type d’alimentation c.a. mentionnée dans les spécifications du produit.

Il est possible d’utiliser des fiches à deux ou à trois branches avec ce produit. Ne pas insérer de force une fiche polarisée (une branche plus grande que l’autre) dans le produit. Retourner la fiche et essayer de nouveau.

Conserver ces instructions. Les consulter fréquemment et les utiliser pour instruire d’autres utilisateurs. Si cet outil est prêté, il doit être accompagné de ces instructions.

FICHE TECHNIQUE

Puissance :

0,2 à 15 A maximum ou 24 à 1 800 W maximum, 100 à 120 V c.a. (50 à 60 Hz)

Arrêt automatique de l’affichage :

2 min.

Entrée : 120 V AC @60Hz

Sortie :15 Amps Max 120V AC @60Hz

Température de service :

32º to 104ºF (0º to 40 Cº)

Humidité d’exploitation :

20% - 80% d’humidité

Altitude d’exploitation: jusqu’à 6500 ft. (2000m)

Pile requise : deux (2) piles boutons LR44

Surtension : 1 500 V

Niveau de protection :

IP20 (protection contre les objets solides mesurant jusqu’à 12 mm);

Niveau de pollution : 2

Mise à la terre :

Catégorie de mesure : CAT III

UTILISATION

UTILISATION DE L’APPAREIL DE MESURE DE LA CONSOMMATION D’ÉLECTRICITÉ

Voir la figure 1.

L’instrument de mesure de la consommation d’électricité calcule le coût de la consommation électrique de la plupart des dispositifs électriques qui se branchent dans une prise de 120 V c.a.

Le coût est déterminé selon le tarif par kilowattheure (kWh) facturé par la compagnie d’électricité locale. Communiquez avec votre compagnie d’électricité afin de connaître ses tarifs ou vérifiez votre relevé de compte le plus récent.

NOTE : Le coût d’exploitation est uniquement calculé une fois que le tarif par kWh a été saisi.

Ceproduitaffichelesampères,leskilowattheures, les watts, le coût d’exploitation ainsi que le coût total pour la période au cours de laquelle l’appareil a été branché.

Avant la première utilisation, retirer la bande de plastique du compartiment des piles situé

àl’arrière de l’unité.

Appuyer sur le bouton « Enter » (Entrée)

(C) et le tenir enfoncé jusqu’à ce que l’heure clignote.

Le réglage par défaut est fixé pour un cycle de 12 heures.

Pourréglerlesheuresetlesminutes,appuyersur le bouton « Clock/timer » (Horloge/chronomètre)

(A)ou sur le bouton « Center » (Centre)

(B).

Appuyer sur le bouton « Enter » (Entrée) (C) pour ajuster le prix par kWh. Appuyer sur les boutons « Clock/timer » et « Center » (A) ou (B) pour modifier le montant en cent.

Une fois que le temps et le prix par kWh ont été saisis, appuyer sur le bouton « Enter » (Entrée)

(C) et le tenir enfoncé jusqu’à ce que l’afficheur cesse de clignoter.

Brancher l’appareil de mesure de la consommation d’électricité dans une prise murale standard mise à la terre, ou le relier au moyen d’un cordon prolongateur mis à la terre de 15 A approuvé par UL et ETL.

Brancher le dispositif qui doit être évalué dans l’appareil de mesure de la consommation d’électricité.

Loading...
+ 1 hidden pages