M-200i Owner’s Manual Supplement
This Owner’s Manual describes functions that have been added or modified since version 1.00 of the M-200i’s system software.
Changes in Version 1.02
♦♦S-4000M control functions have been added. (p. 3)
From the M-200i, you can control the following functions on an S-4000M connected to the M-200i’s REAC port.
Changes in Version 1.01
♦♦New functionality has been added for monitoring. (p. 9)
• Dimmer function (p. 9)
•Merge Patchbay operations (p. 4)
•Output Patchbay operations (p. 5)
•Auto Map operations (p. 5)
•PORT 4 Split Merged Inputs operations (p. 6)
•Saving/loading input/output settings files (p. 7)
♦♦The REAC screen has been changed. (p. 3)
Along with the added functionality for controlling the S-4000M, the REAC screen has changed. Settings for the REAC mode are made at the newly added REAC MODE screen.
♦♦V-LINK source channels have been added.
The following channels have been added to the channels that accommodate V-LINK sources.
•MAIN L/R
•AUX 1–8
•MTX 1–4
•DCA GROUP 1–8
♦♦New functionality has been added for MIDI send.
It is now possible to send MIDI control changes during scene recall.
*This is enabled only when “FADER, MUTE CHANGE (CC)” at the MIDI SEND SETTING screen is set to ON.
♦♦New functionality has been added to scene memory. (p. 10)
•The Global Scope function (p. 10)
•The Recall Safe function (p. 11)
♦♦New functionality has been added to user button functions.
The following functions can be assigned to user buttons.
For details of how to edit the user button assignments, refer to the owner’s manual of the M-200i or the owner’s manual of the M-200i Remote.
•BYPASS GEQ
•EDIT GEQ
•MONITOR DIMMER
♦♦RS-232C commands have been added.
The following RS-232C commands have been added.
For more information, refer to “V-Mixer RS-232C Reference”.
Control Commands
•Monitor dimmer ON/OFF
•USB memory recorder transport
•USB memory recorder locate
•Song select
Request Commands
•Monitor dimmer request
•USB memory recorder status request
•USB memory recorder current position request
•Song number request
•Song name request
•Recording remain time request
♦♦Telnet server functions have been added.
Telnet server functions control the M-200i via a LAN (TCP/IP protocol). For more information, refer to “M-200i Telnet Reference”.
Copyright © 2013 ROLAND CORPORATION
All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION.
1PS
Changes in Version 1.02
♦♦S-4000M control functions have been added. (p. 3)
From the M-200i, you can control the following functions on an S-4000M connected to the M-200i’s REAC port.
•Merge Patchbay operations (p. 4)
•Output Patchbay operations (p. 5)
•Auto Map operations (p. 5)
•PORT 4 Split Merged Inputs operations (p. 6)
•Saving/loading input/output settings files (p. 7)
♦♦The REAC screen has been changed. (p. 3)
Along with the added functionality for controlling the S-4000M, the REAC screen has changed. Settings for the REAC mode are made at the newly added REAC MODE screen.
♦♦V-LINK source channels have been added.
The following channels have been added to the channels that accommodate V-LINK sources.
•MAIN L/R
•AUX 1–8
•MTX 1–4
•DCA GROUP 1–8
♦♦New functionality has been added for MIDI send.
It is now possible to send MIDI control changes during scene recall.
* This is enabled only when “FADER, MUTE CHANGE (CC)” at the MIDI SEND SETTING screen is set to ON.
2
New functionality for Controlling S-4000M
Editing the S-4000M’s Input/Output Settings
The S-4000M has a Merge patchbay and an Output patchbay . * Output patchbay supports S-0808 8x8 I/O UNITS only.
Merge Patchbay |
Accessing the S-4000M CONFIG screen |
|
|
This merges the inputs of the REAC slave units (connected to the REAC ports 1–4 of the S-4000M) into the channels to the M-200i’s REAC port.
Output Patchbay
This assigns channels from the M-200i to the outputs of the S-0808 units (REAC ports 1–4).
NOTE
You cannot edit an S-4000M’s input/output settings when the S-4000M is set to the THRU mode.
Storing Input/Output Setups
The S-4000M input/output setup is saved to internal memory.
The S-4000M CONFIG screen loads and displays the setup from the connected S-4000M.
You can save/load the S-4000M input and output setups to a USB memory as an S-4000M Input/Output Setup file (p. 7).
MEMO
S-4000M’s input/output setups cannot be saved as part of scene memory.
Merge Patchbay and Output Patchbay operations for the S-4000M are made using the S-4000M CONFIG screen.
1.Press [SETUP] to access the SETUP screen.
2.Select “REAC” and press [ENTER].
The REAC screen is displayed.
3. Select “REAC S-4000M” and press [ENTER].
The REAC DEVICE (S-4000M) screen is displayed.
Information about devices connected to the REAC ports is displayed on the REAC DEVICE screen. The icons and menu items vary according to the connected devices.
4. Select “CONFIG” and press [ENTER].
The S-4000M CONFIG screen is displayed.
Changes about the REAC screen
Along with the added functionality for controlling the S-4000M, the REAC screen has changed.
The values for “REAC settings” in the M-200i Owner’s Manual (p. 98) are made at the REAC
MODE screen.
Going to the REAC screen, selecting “REAC MODE” and pressing [ENTER] calls up the REAC
MODE screen.
The names of connected REAC devices are displayed.
3
New functionality for Controlling S-4000M
Merge Patchbay Operations
You can use either of the following two methods to make the settings for Merge Patchbay on the S-4000M, depending on your objective.
(1)Selecting the source to output to REAC port A on the S-4000M (MERGE PATCHBAY screen)
(2)Setting the output destinations of input ports on REAC slave devices connected to REAC ports 1–4 on the S-4000M (S-4000M PORT MERGE screen)
Making the Settings at the MERGE
PATCHBAY Screen
1. Access the S-4000M CONFIG screen.
Making the Settings at S-4000M PORT
MERGE screen
1. Access the S-4000M CONFIG screen.
2. Select “MERGE PATCHBAY” and press [ENTER].
2.Select the port from “PORT1” to “PORT4” where the device you want to change is connected, then press [ENTER].
The S-4000M MERGE PATCHBAY screen is displayed.
3.Select the output connector you want to change and press [ENTER].
MEMO
Selecting “CLEAR MERGE PATCHBAY” and pressing [ENTER] clears (unassigns) all Merge Patchbay settings.
4.From the list, select the REAC port that has the input connector you want to assign, then press [ENTER].
5.From the list, select the input connector you want to assign, press [ENTER], and change the patch.
S-4000M PORT DEVICE screen is displayed.
3. Select “MERGE PATCHBAY” and press [ENTER].
The S-4000M PORT MERGE screen is displayed.
4. Select the target input connector and press [ENTER].
MEMO
Selecting “CLEAR MERGE PATCHBAY” and pressing [ENTER] clears (unassigns) Merge Patchbay settings of the selected port.
5.From the list, select the output connector you want to assign, press [ENTER], and change the patch.
MEMO
You can select and place check marks for multiple output destinations.
4