Roberts Gorden CGTH-40, CGTH-30, CGTH-50 User Manual

0 (0)
Roberts Gorden CGTH-40, CGTH-30, CGTH-50 User Manual

FOR YOUR SAFETY

If you smell gas:

1.Open windows.

2.DO NOT try to light any appliance.

3.DO NOT use electrical switches.

4.DO NOT use any telephone in your building.

5.Leave the building.

6.Immediately call your local gas supplier after leaving the building. Follow the gas supplier’s instructions.

7.If you cannot reach your gas supplier, call the Fire Department.

WARNING

Fire Hazard

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Some objects will catch fire or explode when placed close to heater.

Failure to follow these instructions can result in death, injury or property damage.

Caribe®

Gas-Fired, Low-Intensity

Infrared Heaters for

Residential Garages and

Light Industrial/Commercial

Applications

CGTH-30

CGTH-40

CGTH-50

Use and

Care Manual

WARNING

Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and Service Manual thoroughly before installing or servicing this equipment.

Installation must be done by a contractor qualified in the installation and service of gas-fired heating equipment or your gas supplier.

Installer

Please take the time to read and understand these instructions prior to any installation.

Installer must give a copy of this manual to the owner.

Owner

Keep this manual in a safe place in order to provide your serviceman with necessary information.

Roberts-Gordon, LLC

1250 William Street

P.O. Box 44

Buffalo, New York 14240-0044

Telephone: 716.852.4400

Fax: 716.852.0854

Toll Free: 800.828.7450

Quality in Any Language™

www.rg-inc.com

© Copyright 2007 Roberts-Gordon

P/N 180101NA Rev. B 1/07

TABLE OF CONTENTS

 

SECTION 1: Before You Begin ...............................................

1

1.1 Read This Manual ........................................................

1

1.2 Questions, Comments or Suggestions.........................

1

SECTION 2: Heater Safety......................................................

2

SECTION 3: Introduction........................................................

3

3.1

About Roberts-Gordon ................................................

3

3.2

About the Heater..........................................................

3

3.3

Unpacking the Heater ..................................................

3

3.4

Components Identification ...........................................

4

3.5

Where Can the Heater Be Installed? ...........................

5

3.6

Where Can't the Heater Be Installed?..........................

5

3.7

Installer's Responsibility ..............................................

5

SECTION 4: Before Using The Heater...................................

6

4.1

System Requirements..................................................

6

4.2

Gas Service Requirements:.........................................

6

4.3

Electrical Service Requirements..................................

6

4.4

Venting Requirements..................................................

7

4.5

Non-Residential Installations .......................................

7

4.6

Heater Location ...........................................................

8

SECTION 5: Using The Heater ...............................................

9

5.1

Required Safe Distances from Combustibles...............

9

5.2

Protective Grille..........................................................

13

5.3

Rear Movable Hanger Limits .....................................

14

5.4

Operating Instructions................................................

15

5.5

To Turn Off Gas To Heater .........................................

15

5.6

Sequence of Operation..............................................

16

5.7

Venting.......................................................................

16

SECTION 6: Caring For The Heater .....................................

18

6.1

Annual Inspection ......................................................

18

6.2

Monthly Inspection.....................................................

18

6.3

Maintenance Checklist...............................................

18

6.4

Basic Heater Care......................................................

19

6.5

Replacement Parts ....................................................

19

SECTION 7: The ROBERTS GORDON® CARIBE® LIMITED

 

Warranty.............................................................

21

© 2007 Roberts-Gordon, LLC

All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the written permission of Roberts-Gordon, LLC.

Printed in the U.S.A.

TABLE OF FIGURES

 

Figure 1: Components Identification .........................................

4

Figure 2: Balanced Flue............................................................

7

Figure 3: Thermostat Tag .........................................................

9

Figure 4: Horizontal Installation...............................................

10

Figure 5: 45° Tilted Installation................................................

10

Figure 6: Vent Terminal Clearances ........................................

11

Figure 7: Reflector and Grille ..................................................

13

Figure 8: Typical Installation....................................................

14

Figure 9: Horizontal Venting Through The Wall ......................

16

Figure 10: Horizontal Venting With An Elbow .........................

17

Figure 11: Roof Venting..........................................................

17

SECTION 1: BEFORE YOU BEGIN

SECTION 1: BEFORE YOU BEGIN

Thank you for purchasing a ROBERTS GORDON® heating product. We are pleased you have chosen the CGTH Series overhead tube heater. In addition to the quality you receive from our company, you also receive over 30 years of infrared heating experience.

For years of trouble-free operation from your heater, carefully read this Use & Care Manual. This Manual contains valuable information to help you use the heater safely and properly.

To obtain warranty service, please complete and mail the Owner Warranty Registration Card found on the last page of this manual. In addition to activating your warranty, registering your heater enables us to contact you with safety and product updates.

Keep this manual in a safe place in case you have any questions or require service in the future. Also, since proof of purchase is required to obtain warranty coverage, keep the original sales receipt in a safe place. Remember to record the model and serial numbers of your heater below. Model and serial numbers are found on the rating tag affixed to the heater. See Page 10 for rating tag location.

Model Number:

Serial Number:

Fuel:

Installation Date:

 

 

 

 

Installed By:

 

Purchased From (if different from installer):

Company

 

Company

 

 

 

 

 

Name

 

Name

 

 

 

 

 

Address

 

Address

 

 

 

 

 

Phine

 

Phone

 

 

 

 

 

Fax

 

Fax

 

 

 

 

 

E-mail

 

E-mail

 

 

 

 

 

1.1 Read This Manual

 

1.2 Questions, Comments or Suggestions

Read this manual carefully before installing or servicing this equipment. Improper installation, servicing or maintenance can result in death, injury or property damage. Check the required safe distances from combustibles given on the outside of each burner to make sure that the product is suitable for your application. The required safe distances from combustibles are also found on Pages 9 and 10 of this manual. Installer must be a contractor qualified in the installation and service of gas-fired heating equipment. After the installation is complete, check product operation as provided in these instructions.

Please direct any questions, comments or suggestions to:

Roberts-Gordon, LLC

1250 William Street P.O. Box 44

Buffalo, New York 14240-0044 Telephone: 716.852.4400 Fax: 716.852.0854

Toll Free: 800.828.7450

1

CGTH USE AND CARE MANUAL

SECTION 2: HEATER SAFETY

Your Safety is Important to Us! This symbol is used throughout the manual to notify you of possible fire, electrical or burn hazards. Please pay special attention when reading and following the warnings in these sections.

Installation, Service and Annual Inspection of heater must be done by a contractor qualified in the installation and service of gas-fired heating equipment.

WARNING

Read this manual carefully before using the heater.

Plug the heater into a grounded three-prong ceiling outlet.

Do not install or service any part of the heater. Installation must be done by a contractor qualified in the installation and service of gas-fired heating equipment or your gas supplier.

Installer must exhaust heater outside.

Keep all persons, especially children, away from the heater.

Keep the heater out of the weather. The heater is for indoor areas such as residential garages, workshops, hobby greenhouses, small warehouses, service centers or lobbies. Do not use the heater in living or sleeping areas such as a bedroom or basement.

CAUTION

Do not use heater in an area containing corrosive chemicals.

Avoid the use of corrosive chemicals to ensure a longer life of the burner, tubing and other parts.

Failure to follow these instructions can result in property damage.

2

SECTION 3: INTRODUCTION

SECTION 3: INTRODUCTION

3.1 About Roberts-Gordon

Roberts-Gordon pioneered low-intensity infrared heating systems in 1962 with the introduction of its revolutionary custom-engineered CORAYVAC® system. After more than 40 years of infrared expertise in commercial and industrial applications, Roberts-Gor- don now offers the CGTH-Series heater for use in residential garages and light industrial/commercial applications.

3.2 About the Heater

The CGTH-Series is a factory-assembled, gas-fired, low-intensity heating system that incorporates a balanced flue. The system has been designed for easy installation and will provide years of economical operation and trouble-free service. Not only is infrared heat efficient, it also provides the most comfortable conditions in open areas, such as garages.

Gas-Fired means it uses clean-burning natural or LP gas.

Low-Intensity means that the radiant surface of the tube does not glow red. Instead, it operates at a lower temperature (less than 1000°F) and radiates energy at a lower intensity per square foot of radiating surface. The lower temperature and intensity levels are within a range that is most effective in establishing and maintaining personal comfort levels. An aluminum reflector directs the radiant energy downward to the occupied area.

Balanced Flue means that the burner draws combustion air from outdoors and exhausts the products of combustion, also to the outdoors, through a shared opening. This is accomplished through two concentric tubes.

Radiant refers to the energy radiated by the CGTHSeries heater. Because the energy is in the form of infrared rays, it does not directly heat the air. Instead, the rays heat objects such as the floor, cars, machines and people. The warm objects, in turn, heat the air.

These combined features are the key to the exceptional comfort and fuel efficiency provided by the CGTH-Series heater.

3.3 Unpacking the Heater

3.3.1 Manpower Requirements

To prevent personal injury and damage to the heater, two persons will be required to remove the heater from the carton. Both ends of the heater should be

lifted from the carton at the same time. The burner should be lifted by gripping the bottom. The reflector of the heater should be lifted using the hanger.

3.3.2 Safety

WARNING

Cut Hazard

Wear protective gloves when handling aluminum reflectors.

Edges are sharp.

Failure to follow these instructions can result in injury.

Thin sheet metal parts, such as the reflector portion of the heater and the various venting components, have sharp edges. To prevent injury, the use of work gloves is recommended. The use of gloves will also prevent the transfer of body oils from the hands to the surface of the reflector.

3