Roberts Gorden BH-40, BH-200, BH-80, BH-115, BH-140 User Manual

...
4 (1)
Roberts Gorden BH-40, BH-200, BH-80, BH-115, BH-140 User Manual

FOR YOUR SAFETY

GordonRay

 

BH

If you smell gas:

®

1.

Open windows.

7.

Immediately call your local gas

2.

DO NOT try to light any appliance.

 

 

 

3.

DO NOT use electrical switches.

 

 

 

4.

DO NOT use any telephone in

 

 

 

 

your building.

 

 

 

5.

Extinguish any open flame.

 

 

 

6.

Leave the building.

 

 

 

 

supplier after leaving the building.

The Economical Unitary

 

instructions.

 

Follow the gas supplier’s

 

 

 

8.

If you cannot reach your gas

Infrared Heater

 

supplier, call the Fire Department.

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

Installation, Operation &

 

 

 

 

 

 

 

 

Service Manual

 

 

 

 

BH-40

BH-125

 

 

 

 

 

Fire Hazard

BH-60

BH-140

Do not store or use gasoline or other

BH-80

BH-150

flammable vapors and liquids in the

BH-100

BH-175

vicinity of this or any other appliance.

Some objects can catch fire or explode

BH-115

BH-200

when placed close to heater.

 

 

 

Failure to follow these instructions can result in death, injury or property damage.

WARNING

 

Installer

 

 

Improper installation, adjustment, alteration, service

Please take the time to read and understand

these instructions prior to any installation.

or maintenance can result in death, injury or property

Installer must give a copy of this manual to the owner.

damage. Read the Installation, Operation and Service

 

 

Manual thoroughly before installing or servicing

 

Owner

this equipment.

 

 

 

Installation must be done by a contractor qualified

Keep this manual in a safe place in order to provide

your serviceman with necessary information.

in the installation and service of gas-fired heating

 

 

equipment or your gas supplier.

 

 

 

Roberts-Gordon LLC

 

 

1250 William Street

 

 

P.O. Box 44

 

 

Buffalo, New York 14240-0044

 

Telephone: 716.852.4400

 

 

Fax: 716.852.0854

 

 

Toll Free: 800.828.7450

 

 

www.rg-inc.com

 

© 2009 Roberts-Gordon LLC

www.radiantheaters.com

P/N 170101NA Rev. K 03/09

TABLE OF CONTENTS

SECTION 1: Heater Safety......................................................

1

SECTION 9: Gas Piping........................................................

41

1.1 Manpower Requirements .............................................

1

SECTION 10: Wiring..............................................................

43

1.2 Safety Labels and Their Placement .............................

1

10.1

Line Voltage Thermostat Wiring...............................

43

SECTION 2: Installer Responsibility .....................................

3

10.2

Low Voltage Thermostat Wiring...............................

44

2.1

Wall Tag .......................................................................

3

10.3

Internal Wiring .........................................................

45

2.2

Corrosive Chemicals....................................................

3

10.4

Ladder Diagram.......................................................

46

2.3

National Standards and Applicable Codes ..................

3

10.5

Electrical Connection to the Burner .........................

46

SECTION 3: Clearances to Combustibles.............................

4

SECTION 11: Operation and Maintenance..........................

47

3.1

Required Clearances to Combustibles.........................

4

11.1 Sequence of Operation ............................................

47

SECTION 4: National Standards and Applicable Codes .....

9

11.2 To Shut Off Heater....................................................

47

4.1

Gas Codes...................................................................

9

11.3 To Start Heater .........................................................

47

4.2

Aircraft Hangars ...........................................................

9

11.4 Pre-Season Maintenance and Annual Inspection.....

47

4.3

Public Garages ............................................................

9

11.5 Maintenance Checklist .............................................

49

4.4

Electrical ......................................................................

9

SECTION 12: Troubleshooting.............................................

51

4.5

Venting.........................................................................

9

12.1

Troubleshooting Flow Chart.....................................

52

4.6

High Altitude ................................................................

9

12.2

Manifold Gas Pressure Setting ................................

54

SECTION 5: Major Components ..........................................

10

SECTION 13: Replacement Parts ........................................

55

5.1

Standard Parts List ....................................................

11

SECTION 14: General Specifications ..................................

58

SECTION 6: Heater Installation............................................

13

14.1

Material Specifications.............................................

58

6.1

Burner Tube Installation ............................................

17

14.2

Heater Specifications...............................................

58

6.2

Tube Clamp Package Installation..............................

18

14.3

Suspension Specifications.......................................

58

6.3

Coupling and Tube Assembly....................................

18

14.4

Controls Specifications ............................................

58

6.4

Turbulator Installation ................................................

20

SECTION 15: The ROBERTS GORDON® GORDONRAY® BH

6.5

Reflector Installation ..................................................

21

 

Warranty .........................................................

59

6.6

Burner Installation......................................................

23

 

 

 

SECTION 7: Optional Heater Accessories..........................

24

 

 

 

7.1 U-Tube Configuration..................................................

24

 

 

 

7.2 Elbow Package Configuration.....................................

27

 

 

 

7.3 Reflector Side Extension ............................................

30

 

 

 

7.4 Lower Clearance Shield Installation ...........................

31

 

 

 

7.5 Two-Foot Decorative Grille Installation .......................

31

 

 

 

7.6 Protective Grille Installation ........................................

33

 

 

 

SECTION 8: Venting..............................................................

34

 

 

 

8.1

Venting.......................................................................

34

 

 

 

8.2

Unvented Operation...................................................

35

 

 

 

8.3

Horizontal Venting......................................................

35

 

 

 

8.4

Vertical Venting..........................................................

35

 

 

 

8.5

Unvented Operation Tube Termination ......................

35

 

 

 

8.6

Length Requirements ................................................

35

 

 

 

8.7

Horizontal Ventilation 4'' (10 cm) Pipe .......................

36

 

 

 

8.8

Vertical Ventilation 4'' (10 cm) Pipe............................

36

 

 

 

8.9

Common Side Wall Venting .......................................

37

 

 

 

8.10 Common Vertical Venting ........................................

38

 

 

 

8.11 Outside Combustion Air Supply ...............................

39

 

 

 

© 2009 Roberts-Gordon LLC

All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the written permission of Roberts-Gordon LLC.

Printed in U.S.A.

TABLE OF FIGURES

 

Figure 1: Top and Bottom Panel Label Placement ....................

1

Figure 2: Side and Back Panel Label Placement......................

2

Figure 3: Standard Reflector .....................................................

5

Figure 4: One Side Reflector.....................................................

5

Figure 5: Two Side Reflectors ...................................................

5

Figure 6: 45° Tilt Reflector ........................................................

6

Figure 7: U-Tube, Standard Reflector........................................

6

Figure 8: U-Tube, 45° ................................................................

6

Figure 9: U-Tube, Opposite 45° Reflector .................................

7

Figure 10: 2-Foot Deco Grille and Protective Grille ...................

7

Figure 11: Lower Clearance Shield ...........................................

7

Figure 12: Venting .....................................................................

8

Figure 13: Major Component Descriptions..............................

10

Figure 14: Critical Hanger Placement .....................................

14

Figure 15: Linear Heater Assembly Overview ........................

15

Figure 16: Linear Heater Layout Overview .............................

16

Figure 17: Linear Heater Layout Overview (Continued) ..........

17

Figure 18: U-Tube Heater Assembly Overview ......................

25

Figure 19: U-Tube Heater Layout Overview ...........................

26

Figure 20: U-Tube Layout Overview (Continued) ....................

27

Figure 21: Reflector Joint Detail..............................................

29

Figure 22: Tube Termination ...................................................

35

Figure 23: Gas Connection with Flexible Gas Hose................

42

LIST OF TABLES

 

Table 1: Contents of BH-Series Burner Carton.......................

11

Table 2: Contents of Core and Extension Packages ..............

11

Table 3: BH-Series Component Package Guide ....................

12

Loading...
+ 14 hidden pages