R75LSi (VA2528FFUD)

 

 

 

Type of Appliance

Temperature controlled, continuous flow, gas hot water system

Rinnai Model Number

REU-VA2528FFUD(A)-UC

 

Operation / Exhaust System

Forced combustion / Direct vent

Minimum/Maximum Gas Rate (Input)

15,000 - 180,000 BTU/h (Natural Gas and Propane)

Electrical

Appliance:

AC 120 Volts - 60 Hz

 

Controller:

DC 12 Volts

Electrical Consumption

Normal

65 watts

 

Standby

2.0 watts

 

Anti-frost protection

100 watts

Ignition System

Direct electronic ignition

 

Hot Water Capacity

0.6 to 7.5 GPM (35° F rise)

 

Temperature

98° - 120° F (factory default)

Maximum temperature is selectable at

 

120° F or at 140° F; 98° - 160° F available with the MCC-91

 

controller for commercial and hydronic applications

Temperature (without remote)

120° F (factory default)

 

Approved Gas Types

Natural or Propane (ensure unit matches gas type)

Installation

Indoor only

 

Energy Factor

Natural Gas: 0.82

Propane: 0.82

Thermal Efficiency

Natural Gas: 84%

Propane: 84%

Service Connections

Gas supply: 3/4 inch MNPT

 

 

Cold water inlet: 3/4 inch MNPT

 

Hot water outlet: 3/4 inch MNPT

Water Flow Control

Water flow sensor, electronic water control device and fixed by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (recommended 30-80 PSI for maximum performance)

 

 

 

FLOW TABLE

8.0

 

 

 

 

 

 

 

7.0

 

 

 

 

 

 

 

6.0

 

 

 

 

 

 

 

(gpm)

 

 

 

 

 

 

 

5.0

 

 

 

 

 

 

 

4.0

 

 

 

 

 

 

 

Flow3.0

 

 

 

 

 

 

 

Water

 

 

 

 

 

 

 

2.0

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

 

0.0

 

 

 

 

 

 

 

0

25

50

75

100

125

150

delta T - Temperature Rise (ºF)

© 2008 Rinnai Corporation

R75LSi SP

8/2008

Loading...