Rinnai Q130SP, Q130SN, Q175CN, Q175CP, Q175SN User Manual

...
0 (0)
Rinnai Q130SP, Q130SN, Q175CN, Q175CP, Q175SN User Manual

User information manual

High efficiency condensing gas boiler

Q85SN/Q130SN/Q175SN/Q205SN/Q175CN

Q85SP/Q130SP/Q175SP/Q205SP/Q175CP

WARNING! Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Pictured: Q85SN, Q130SN

Q85SP, Q130SP

WARNING!

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

-WHAT TO DO IF YOU SMELL GAS

-Do NOT try to light any appliance.

-Do NOT touch any electrical switch.

-Do NOT use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Français: voir page 17

Address: 103 International Drive, Peachtree City, GA, 30269

Toll-free: 1-800-621-9419 Fax: 678-829-1666 www.rinnai.us

8W.52.4000/11.09 Changes reserved

Notice! This manual must be retained for future reference.

Contents of instructions

These instructions contain important information for the safe use of Rinnai Q-Series gas boilers.

These user instructions are intended for the owner or responsible tenant of the premises where the boiler is installed.

Subject to technical changes

Changes may be made to the illustrations, process steps and technical data as a result of our policy of continuous improvement without prior notice.

Updating of documentation

Please contact us if you have any suggestions for improvements or corrections.

Find our contact details on the back of this manual.

Operating instructions Rinnai Q-Series

2

Operating instructions Rinnai Q-Series

Safety and general instructions

Please observe these instructions in the interest of your own safety.

Designated use

The boiler is designed to heat water for a central heating system and, if applicable, generating domestic hot water. The boiler is delivered with a burner controller pre-installed.The boiler can be fitted with a modulating outdoor reset control

ARV12 (included), a room controller RS100 (optional), a zone controller (optional) or an On/Off thermostat or relay panel end switch (accessories).

Hazard definitions

The following defined terms are used throughout the documentation to bring attention to the presence of hazards of various risk levels. Notices give important information concerning the operation of the product.

!

DANGER

DANGER:

the

presence of

hazards

that

 

 

Indicates

 

 

will cause severe personal injury, death or

 

 

substantial property damage.

 

 

!

WARNING

WARNING:

 

 

 

 

Indicates

the

presence of

hazards

that

 

 

can cause severe personal injury, death or substantial property damage.

!

i

CAUTION

NOTICE

CAUTION:

Indicates presence of hazards that will or can cause minor personal injury or property damage.

NOTICE:

 

Indicates special instructions on installation,

 

operation or maintenance that are important

 

but not related to personal injury or property

3

damage.

These operating instructions describe the operation of the Rinnai Q-Series condensing gas boilers. This manual is for the end user. For installation and servicing there is a installation & servicing instructions manual for the installer.

Read this manual fully before operating the boiler. In case of doubt or errors contact your installer. The manufacturer reserves the right to change the specifications and dimensions without prior notice.

Work on the boiler must be carried out by a State licenced contractor, (Ref: Gas Safety Installation and Use) using correctly calibrated instruments with current test certification.

Operating instructions Rinnai Q-Series

4

Safety

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do NOT try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do NOT try to light any appliance.

-Do NOT touch any electrical switch.

-Do NOT use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools.

If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any parts have been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above this label.

2.Turn off al electrical power of the appliance.

3.Set the thermostat or other operating control to the lowest setting.

4.This appliance is equipped with an ignition device

which automatically lights the burner. Do NOT try to light the burner by hand.

5.Close main gas shut off valve.

6.Wait (5) minutes to clear out any gas. Then smell for

gas. Including near the floor.

If you smell gas, STOP! Follow “B” in the safety information above on this label.

If you don’t smell gas, go to the next step.

Manual Gas Valve (Main valve) CLOSE OPEN

7.Open main shut off valve.

8.Set the thermostat or other operation control to desired setting.

9.Turn on all electric power to the appliance.

10.If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Turn off all electric power to the appliance if service is to be performed.

2.Set the thermostat or other operating control to the lowest setting.

3.Close main gas shut off valve.

8U.34.01.00 / 05.09

Operating instructions Rinnai Q-Series

5

Operating instructions Rinnai Q-Series

6

!

!

i

DANGER

WARNING

NOTICE

Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance.

Protection for corrosion

Do not use any sprays, chlorine containing agents, solvents, paint etc. around the boiler or around the air intake supply entrance of the boiler. These substances have negative influences on the boiler and can lead to corrosion resulting in failure of the boiler.

Products to avoid present in boiler room and/or around combustion air intake

Spray cans containing chloro-/fluorcarbons Ammonium and/or ammonium solutions Permanent wave solutions

Chlorinated waxes and/or cleaners Swimming pool chemicals based on chlorine Calcium chloride used for thawing

Sodium chloride used for water softening Refrigerant leaks

Paint or varnish removers Hydrochloric acid/muriatic acid Cements and glues

Antistatic fabric softeners used in clothes dryers Chlorine-type bleaches, detergents, and cleaning solvents found in household laundry rooms

Adhesives used to fasten building products and other similar products

Areas likely to have contaminants

Dry cleaning/laundry areas and establishments

Swimming pools

Metal fabrication plants

Beauty shops

Refrigeration repair shops

Photo processing plants

Auto body shops

Plastic manufacturing plants

Furniture refinishing areas and establishments

New building construction

Remodeling areas

Garages with workshops

Checking the water pressure

Check the water pressure in the central heating installation regularly.

Use only potable water for filling.

Additives only after clearance by Rinnai. Contact your installer in case of doubt.

Description of the boiler

The Rinnai Q boiler is a room sealed, condensing and modulating central heating boiler. The Q175C has an integrated domestic hot water feature.

The boiler is provided with a integrated control system. Because an outdoor sensor is connected to the boiler, the boiler works weather dependantly. This means that the boiler control measures the outside temperature and flow temperature. With this data the boiler calculates the optimal flow temperature for the installation.

When the boiler is connected to an RS100 room thermostat information can be retrieved from the boiler. For more information about the Rinnai thermostats. Please refer to the user manuals.

RS100

On the bottom left side of the front panel there is a

 

 

small door. Through the transparent panel you can

 

see the boiler status on the display. After opening

 

this door you will find the function buttons.

 

Onthefollowingpagesyouwillfindtheexplanation

 

of the function buttons and display messages.

Operating instructions Rinnai Q-Series

7

Explanation of the function buttons

1

3

4

5

6

i NOTICE

-Series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

i

NOTICE

Q

When the pump is switched

Rinnai

on continuously it can lead

 

instructions

to undesired heating up of

the central heating system

 

 

during the summer.

Operating

i

NOTICE

 

 

 

 

 

 

 

 

 

 

 

 

8

2

7

8

Only qualified personel who are trained for these boilers are permitted to make alterations in the controller to chronolize the boiler to the installation.

1.Display.

See following pages for further information.

2.ON-OFF Switch

This switch turns the power supply to the boiler on or off.

3.Central Heating program button.

Switching the Central Heating on or off (Led on/off);

4.Hot Water program button.

Switching the Domestic Hot Water (DHW) facility on or off (Led on/off);

5.Pump program button.

When the pump program LED is ON, the pump is switched into a continuous circulation mode. When the pump mode is switched OFF, LED is off the pump is control by the boiler processor. In most situations it is best to leave the pump mode OFF and let the boiler control cycle the pump as needed.

During freezing temperatures it is possible (when there is no outside sensor connected), to manually place the circulation pump in constant circulation mode, thus reducing the chance of freezing pipes (garage, attic or other cold spaces / rooms) which are sensitive to frost.

6 Mode-button.

Only for Service personel

7Step-button.

After briefly pressing, the water pressure can be retrieved.

After pressing for 5 seconds it switches from the Good-state to technical read out and vice versa (see following pages);

8Reset-button.

When a fault occurs it will be shown by the flashing E (Error) with a number code after which the boiler is shut down. After pressing the reset key you can try to start the boiler again. If the error message keeps occurring contact your installer.

! WARNING DO NOT attempt to make repairs or remove any of the boiler panels. Contact a qualified

service agency to make necessary repairs or adjustments.

Operating instructions Rinnai Q-Series

9

The boiler display

Two boiler displays, “Good or Technical” see below.

Good

or standard read out.

During this reading the display will only show what is necessary. Under normal circumstances the display will give a Good reading. In case of a fault this will be shown with, alternate display of

Good, with an E or BL code. See further "Errors, maintenance and warranty" .

Operating instructions Rinnai Q-Series

10

0

1

2

3

4

5

6

7

8

9 A

Technical

The second way is a technical read out. In normal situations the following will be shown:

ontheleftthestatusinwhichtheboilerisactive

(see bottom of this page);

on the right the supply temperature in °F;

the water pressure in the installation in PSI.

When a message (E or BL code) is necessary this will be shown instead of the technical read out.

To switch over from the Good-state to the Technical read out (and vice versa):

- Press 5 sec. on the STEP-button.

Operation indication

(in the first display position by technical read out)

No heat demand Fan pre/post purge

Ignition phase

Burner active on central heating

Burner active on DHW

Fan check

Burner off when room thermostat is demanding Pump overrun phase for central heating

Pump overrun phase for hot water

Burner off because of to high flow temperature

Automatic de-aeration program (Press no button for 17 min.)

Loading...
+ 22 hidden pages