Rinnai INFINITY 26i, REU-VR2632FFUG, HD 200i, REU-VRM2632FFUC User Manual

0 (0)

UP

FF Flue

Installation

Manual

Rinnai FF coaxial flue system, suitable for use with the following Rinnai internal continous flow water heater models:

INFINITY 26i

REU-VR2632FFUG

HD 200i

REU-VRM2632FFUC

These components shall be installed in accordance with:

Manufacturer’s Installation Instructions

Current AS/NZS 3000, AS/NZS 3500 & AS 5601

Local Regulations and Municipal Building Codes

These components must be installed, serviced and removed by an Authorised Person.

INSTALLATION GENERAL

This flue must be installed by an authorised person. The Installation must conform to local

regulations.

 

Installation must comply with the instructions supplied by Rinnai.

Service and removal must be carried out by an authorised person.

TABLE OF CONTENTS

 

CERTIFICATION .......................................................................................

1

GENERAL ..................................................................................................

1

FF FLUEING OPTIONS .............................................................................

2

GENERAL INSTALLATION METHODS ...................................................

3

DIRECT HORIZONTAL FLUE ...................................................................

4

EXTENDED HORIZONTAL FLUE .............................................................

4

VERTICAL FLUE .......................................................................................

5

COMBINED VERTICAL & HORIZONTAL FLUE ......................................

5

CONDENSATE DRAIN ..............................................................................

6

DIMENSIONS ............................................................................................

8

CLEARANCES ..........................................................................................

9

CONTACT INFORMATION .....................................................................

10

CERTIFICATION

Certified by the Australian Gas Association (AGA) For use only with Rinnai internal continuous flow water heaters.

GENERAL

1.These instructions only apply to the Rinnai FF water heater coaxial flueing system. This flue system utilises pipe components with an aluminium inner pipe and a white plastic outer pipe.

These instructions DO NOT apply to older Rinnai water heater flueing that has either a stainless steel single skin or stainless steel coaxial construction. If in doubt contact Rinnai.

2.Before commencing installation, please read the 'Installation Instructions - General', located inside a pouch behind the front cover of all Rinnai water heater models. The Rinnai internal water heater range must only be installed with Rinnai water heater flueing as referred to in these instructions.

3.The requirements of the current AS5601/AG601 and local authorities must be met, which is the installers responsibility.

4.The required clearances of Rinnai internal continuous flow water heater when installed as a single unit are shown in Fig.1A. The appliances are certified to be installed side by side as shown on page 7, allowing a minimum distance between flues as follows:

270mm between horizontal terminals.

160mm between vertical cowls.

5.Rinnai internal continuous flow water heaters fitted with FF flue systems are room sealed as defined in AS5601. No ventilation in the space where the water heater is installed is required.

6.The outer plastic section of the coaxial flue complies with temperature hazard requirements and can be installed with zero clearance to combustible material.

Rinnai Australia

1

Installation Manual

Rinnai INFINITY 26i, REU-VR2632FFUG, HD 200i, REU-VRM2632FFUC User Manual

FF FLUEING OPTIONS

FFWPLATE or FFWSEAL (Optional)

FFSBEND

Cap Tube Drain

Fig. 1

127mm Hole

FFWPLATE or

127mm Hole

FFWSEAL (Optional)

 

FFSBEND

 

 

2° fall to

2° fall to

 

terminal

 

terminal

 

FFWPLATE

FFWPLATE

 

 

 

FFWALLTERM

FFWALLTERM

Tube Drain

 

 

Cap

 

 

 

minimum 45

FFSBEND

FFPIPE1000

FFWALLTERM

 

2° fall to terminal

 

Drain Tube Cap

 

FFROOFCOWL

Fig. 3

 

Minimum

 

Minimum

Clearance

 

Clearance

500 mm

Decktite or lead

500 mm

 

 

 

collar flushing

 

 

Flue pipe clip

 

 

supplied with

 

 

FFROOFCOWL

 

Flue pipe clip

 

Flue pipe clip

supplied with

 

supplied with

FFPIPE1000

 

FFPIPE1000

FFPIPE1000

FFWSEAL

FFPIPE1000

 

Flue pipe clip

FFBEND

 

supplied with

 

 

 

FFPIPE1000

 

FFPIPE1000

 

FFPIPE1000

Drain Tube

(See Page 6)

FFPIPE1000

FFBEND

FFPIPE1000

FFSBEND

Fig. 2

FFROOFCOWL

Decktite or lead collar flushing

Flue pipe clip supplied with FFROOFCOWL

FFWSEAL

 

FFPIPE1000

 

FFWALLTERM

FFBEND

2° fall t

 

Termina

2° fall

Fig. 4

to trap

 

 

 

Drain Tube

Flue pipe clip supplied with FFPIPE1000

 

 

 

 

 

 

(See Page 6)

 

 

 

 

DIRECT HORIZONTAL (FIG. 1)

A horizontal flue installation that consists of a starter bend (FFSBEND) and a wall terminal (FFWALLTERM) only. See page 4 for details.

HORIZONTAL EXTENDED (FIG. 2)

A horizontal flue installation that consists of a starter bend (FFSBEND), flue pipe(s) (FFPIPE1000) and a wall terminal (FFWALLTERM). See page 4 for details.

VERTICAL (FIG. 3)

A vertical installation that consists of flue pipe(s) (FFPIPE1000) and a roof terminal (FFROOFCOWL). See page 5 for details.

VERTICAL / HORIZONTAL (FIG. 4)

A combination of pipe(s) (FFPIPE1000) and bends (FFSBEND/FFBEND) that terminate with either a wall (FFWALLTERM) or roof (FFROOFCOWL) terminal. See page 5 for details.

For condensation drain fitting requirements see the section “CONDENSATE DRAIN” on page 6.