Rheem RF1T, RF1P Specification

4 (1)

Air Handlers

Air

RF1T/RF1P Series

Rheem Air Handler

RF1TSeries

X-13 (ECM) Motor

Efficiencies up to 16 SEER

RF1PSeries

PSC Motor

Efficiencies up to 14.5 SEER

Front or Bottom Return with aluminum tube and fin coil

Flow Check Piston for cooling or heat pump operation

Wall-hanging brackets

Built in Filter Rack

Suitable for R-410A or R-22 Refrigerants (RF1P Only)

AHRI Certified

UL Certified

Molex Plug Connections for field installed heater kits

Dual Voltage Direct Drive Blower with multi-speed motor

Thermoplastic Drain Pan with bottom primary and secondary connections

Optional Decorative Grill for front return applications

Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in event the condensate pan becomes clogged

FORM NO. H11-555

Table of Contents

 

Air

 

RF1T/RF1P Series

 

TABLE OF CONTENTS

 

Engineering Features ......................................................................................

3

Model Number Identification ............................................................................

4

Dimensional Data ........................................................................................

5-6

Airflow Performance Data ............................................................................

7-9

Piston Sizing Chart ........................................................................................

10

Electrical Data ..............................................................................................

11

Accessories ............................................................................................................

12

Limited Warranty ..........................................................................................

13

2

Engineering Features

RF1T/RF1PSeries

The most compact unit design available, all standard heat air handler models only 36" [915 mm].

Rugged wall steel cabinet construction, designed for added strength and versatility.

1.0" foil faced insulation for excellent thermal and sound performance.

Four leg blower motor mount.

Traditional open wire element design for heat applications.

Indoor coil design provides low air side pressure drop, high performance and extremely compact size.

[ ] Designates Metric Conversions

Engineering Features

Air

RF1T/RF1P Series

Coils are constructed of aluminum fins and internally grooved aluminum tubing.

Molded polymer corrosion resistant condensate drain pan is provided for all indoor coils.

Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet.

Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 13/8 inch inches [35 mm] for 7/8 inch [22 mm] conduit.

3

Model Number Identification

Air

RF1T/RF1P Series

Model Number Identification

R F 1 T 24 21 S P A N J A N 00 ***

Option Code

Blank = None

Factory Heat

00 = NO HEAT

03 = 3 kW

05 = 5 kW

08 = 8 kW

10 = 10 kW

Disconnect

B = Breaker

N = None

Minor Series

A = First

Voltage

J = 208/240/1/60

Controls

N = Non-communicating

Major Series

A = First

Metering Device

T = TEV

P = Piston

Efficiency

S = Standard

M = Medium

H = High

Width

21 = 21.5"

24 = 24"

Nominal Capacity

18 = 18,000 BTU/H [5.30 kW]

24 = 24,000 BTU/H [7.03 kW]

30 = 30,000 BTU/H [8.80 kW]

36 = 36,000 BTU/H [10.6 kW]

Motor Type

P = PSC

T = Constant Torque

Stage of Air Flow

1 = Single

Product Category

F = Front Return Air Handler

Rheem

4

Available Models

RF1P1821SPANJAB03

RF1P1821SPANJAB05

RF1P1821SPANJAB08

RF1P1821SPANJAN00

RF1P2421SPANJAB03

RF1P2421SPANJAB05

RF1P2421SPANJAB08

RF1P2421SPANJAB10

RF1P2421SPANJAN00

RF1P3024SPANJAB03

RF1P3024SPANJAB05

RF1P3024SPANJAB08

RF1P3024SPANJAB10

RF1P3024SPANJAN00

RF1P3624SPANJAB03

RF1P3624SPANJAB05

RF1P3624SPANJAB10

RF1P3624SPANJAN00

RF1P3624STANJAB03

RF1P3624STANJAB05

RF1P3624STANJAB08

RF1P3624STANJAB10

RF1P3624STANJAN00

RF1T2421MTANJAB03

RF1T2421MTANJAB05

RF1T2421MTANJAB08

RF1T2421MTANJAB10

RF1T2421MTANJAN00

RF1T3624MTANJAB03

RF1T3624MTANJAB05

RF1T3624MTANJAB08

RF1T3624MTANJAB10

RF1T3624MTANJAN00

Note: All models available with option code 417 (float switch)

Supply circuit protective devices may be fuses or “HACR” type circuit breakers.

Largest motor load is included in single circuit.

If non-standard fuse size is specified, use the next larger fuse size.

J Voltage (230V) single-phase air handler is designed to be used with single or three phase 230 volt power. In the case of connecting 3-phase power to the air handler terminal block, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead.

The air handlers are shipped from the factory with the proper indoor coil installed, and cannot be ordered without a coil.

Rheem RF1T, RF1P Specification

Dimensional Data

Air

RF1T/RF1P Series

Unit Dimensions

Unit Dimensions & Weights

Dimensional Data

 

(A) Unit

(B) Unit

(C) Unit

(D) Return

(E) Return

 

Air Flow

 

 

Air Opening

Air Opening

CFM (Nom.) [L/s]

Unit Weight/

Model

Width

Height

Depth

Width

Height

 

 

 

Shipping Weight (Lbs.) [kg]

 

In. [mm]

In. [mm]

In. [mm]

In. [mm]

In. [mm]

Low

High

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF1P18

211/2 [546.1]

36 [914.4]

17 [431.8]

20

[508]

177/16 [442.9]

600

[283]

80 [36] / 90 [41]

RF1P24

211/2 [546.1]

36 [914.4]

17 [431.8]

20

[508]

177/16 [442.9]

800

[378]

80 [36] / 90 [41]

RF1P30

241/2 [609.6]

36 [914.4]

21 [533.4]

23 [584.2]

213/88 [542.9]

1000

[472]

95 [43] / 105 [48]

RF1P36

241/2 [609.6]

36 [914.4]

21 [533.4]

23 [584.2]

213/88 [542.9]

1200

[566]

95 [43] / 105 [48]

RF1T24

211/2 [546.1]

36 [914.4]

17 [431.8]

20

[508]

177/16 [442.9]

600

[283]

800 [378]

95 [43] / 105 [48]

RF1T36

241/2 [609.6]

36 [914.4]

21 [533.4]

23 [584.2]

213/88 [542.9]

1000

[472]

1200 [566]

95 [43] / 105 [48]

[ ] Designates Metric Conversions