Rex D21 User Manual

5 (1)
Rex D21 User Manual

Time switch

MicroRex D21

NT 29 17 86 02

 

 

 

 

 

 

 

 

Technical data

 

 

 

 

 

 

Connection

Supply voltage:

230V 50/60Hz

120V 50/60Hz

 

 

 

 

 

 

Consumption:

ca. 0,5W

 

 

 

 

 

 

 

Contact rating:

changeover contact 16A 250V~µ cos ϕ = 1

 

1

2

 

 

 

Parallel compensation:

60VA max. 7µF

 

 

 

 

 

 

 

Accuracy:

±2,5s/d

 

 

 

 

 

 

 

Terminal capacity:

single strand

multi strand

 

 

 

 

 

 

 

4 mm2

2,5 mm2

 

 

 

 

 

 

Program pictures:

8

 

 

 

 

 

 

 

Battery reserve:

100h

 

 

6

7

8

 

 

Storage ambient:

-10°C to +60°C

 

 

 

 

 

 

3

4

5

 

 

Working ambient:

-10°C to +55°C

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

Safty notes

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Installation of these products should only be undertaken by a qualified electrician.

 

 

 

 

 

 

 

 

• The operational and electrical safety is only guaranteed, if the product is installed using its proper

 

 

 

 

 

 

 

accessories, in a position as specified in the installation instructions.

 

 

 

 

 

 

 

 

• Any interference with the product makes the guarantee void.

 

 

 

 

 

 

 

 

• If the time switch is mounted near equipment where heat produced raises the local ambient above 55°C. Then a space should be put

 

 

 

 

 

 

between the time switch and the equipment.

 

700W

700W

2500W

700W

2900W

900W

 

 

Function

The MicroRex D22 is a microprocessor controlled digital time switch. Eight programs of your choice can be stored and used to control the automatic operation of your electrical equipment. Each individual weekday can have a separate program or you can have several days operating on the same „Block“program. To program the MicroRex D22 a „picture“is used and when this is complete the chosen times are stored in the microprocessor memory. The MicroRex D22 makes available 2 separate switching channels. The summer-/winter changeover can be programmed for hand or automatic operation.

Presentation

Liquid Crystal Display

Actual or „On“time

 

Weekday

1

1 2 3 4 5 6 7

Day number „Off“time

Programming Buttons

Delete

Choose function

Summer- / winter

± 1h

1

C

changeover

 

 

Setting the hours, minutes,

S

OK

 

 

days and channels

 

R

Symbol for

„Set actual time“

State of output

= On

= Off

„Off“days

Hand switch

Channel 1

Fixing the hours, minutes, days, channels and continuous switching

1. Starting

Approximately 30 seconds after the supply voltage is connected the symbols appear on the LCD.

Before any operations the complete memory must be reset.

2. Memory reset

S + OK press both at the same time

The time switch memory is completely clear.

3. Setting date and summer- / winter changeover

This can only be done after a Reset.

Summer- / winter changeover can be made manually or automatically if set. If manual changeover is required choose no during the date input. Automatic changeover depends on your country / area. Choose the appropriate setting for your country / area.