Renesas H8/3937 Series, TFP-100G User Manual

Loading...

H8/3937R, H8/3937 Series TFP-100G

User System Interface Cable

(HS3937ECN61H)

for E6000 Emulator

User’s Manual

HS3937ECN61HE(B)

Cautions

1.Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.

2.Products and product specifications may be subject to change without notice. Confirm that you have received the latest product standards or specifications before final design, purchase or use.

3.Renesas makes every attempt to ensure that its products are of high quality and reliability. However, contact Renesas’s sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment or medical equipment for life support.

4.Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating, operating supply voltage range, heat radiation characteristics, installation conditions and other characteristics. Renesas bears no responsibility for failure or damage when used beyond the guaranteed ranges. Even within the guaranteed ranges, consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so that the equipment incorporating Renesas product does not cause bodily injury, fire or other consequential damage due to operation of the Renesas product.

5.This product is not designed to be radiation resistant.

6.No one is permitted to reproduce or duplicate, in any form, the whole or part of this document without written approval from Renesas.

7.Contact Renesas’s sales office for any questions regarding this document or Renesas semiconductor products.

Preface

Thank you for purchasing this user system interface cable (HS3937ECN61H) for the Renesas’s original microcomputer H8/3937R, H8/3937 series.

The HS3937ECN61H is a user system interface cable that connects an H8/300L series E6000 emulator (HS388REPI60H; hereinafter referred to as the emulator) through the expansion board to the IC socket for a TFP-100G package for the H8/3937R, H8/3937 series MCU on the user system.

i

Contents

Section 1

Configuration....................................................................................

1

Section 2

Connection Procedures......................................................................

3

2.1

Connecting User System Interface Cable to Expansion Board.........................................

3

2.2

Connecting User System Interface Cable to User System ................................................

5

 

2.2.1

Installing IC Socket .............................................................................................

6

 

2.2.2

Soldering IC Socket.............................................................................................

6

 

2.2.3

Inserting Cable Head ...........................................................................................

7

 

2.2.4

Fastening Cable Head ..........................................................................................

7

 

2.2.5

Fastening Cable Body..........................................................................................

9

2.3

Recommended Dimensions for User System Mount Pad .................................................

10

2.4

Dimensions for User System Interface Cable Head..........................................................

11

2.5

Resulting Dimensions after Connecting User System Interface Cable.............................

12

Section 3 Installing the MCU to the User System.............................................

13

Section 4

Verifying Operation...........................................................................

15

Section 5

Notice ................................................................................................

17

ii

Renesas H8/3937 Series, TFP-100G User Manual

Section 1 Configuration

CAUTION

Use an NQPACK100SE socket (manufactured by Tokyo Eletech Corporation) for the TFP-100G package IC socket on the user system.

Figure 1 shows the configuration of the HS3937ECN61H user system interface cable for the TFP-100G package.

Figure 1 HS3937ECN61H User System Interface Cable

1

Table 1 lists the HS3937ECN61H components. Please make sure you have all of these components when unpacking.

Table 1 HS3937ECN61H Components

No.

Component

Quantity

Remarks

1

Cable body

1

Flat cable

 

 

 

 

2

Cable head

1

 

 

 

 

 

3

IC socket

1

For the TFP-100G package

 

 

 

 

4

Socket cover

1

For installing an TFP-100G packaged MCU

 

 

 

 

5

Screws (M2.0 x 10 mm)

4

For fastening cable head

 

 

 

 

6

Screws (M2.0 x 6 mm)

4

For installing an TFP-100G packaged MCU

 

 

 

 

7

Guide pins (φ 1 mm)

3

For determining the IC socket location

 

 

 

 

8

Screwdriver

1

For tightening screws

 

 

 

 

9

Documentation

1

User’s manual for HS3937ECN61H (this manual)

 

 

 

 

2

Section 2 Connection Procedures

2.1Connecting User System Interface Cable to Expansion Board

WARNING

Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be

LOST.

1.Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.

2.The user system interface cable dedicated to the emulator must be used.

To connect the cable body to the emulator station, follow the instructions below. 1. Make sure the user system and emulator station are turned off.

CAUTION

When connecting or removing the user system interface cable, apply force only in the direction suitable for connection or removal, while making sure not to bend or twist the cable or connectors. Otherwise, the connectors will be damaged. The user system interface cable must be connected to an H8/300L Series E6000 emulator through the H8/3937R, 3937 Series expansion board. Do not connect the

user system interface cable directly to the E6000 emulator.

3