RECOM R05X05, R05X09, R05X12, R05X13, R05X15 Datasheet

...
0 (0)
RECOM R05X05, R05X09, R05X12, R05X13, R05X15 Datasheet

EUROLINE - DC/DC-Converter

RxxX and RxxY Series, 1 Watt, SIP7/DIP14, Regulated / Isolated (Single Output)

Features

 

 

 

 

1kVDC Isolation

 

Toroidal Magnetics

 

 

Efficiency to 62%

 

Fully Encapsulated

 

 

UL 94V-O Package Material

MTTF up to 2.4 Million Hours

 

 

Internal SMD Construction

Output Regulation <1.5%

 

 

Selection Guide

 

 

 

 

Part

Output

Output

Power

Package

Number

Voltage

Current

Out

Style

 

(VDC)

(mA)

(mW)

 

Flash PROM types

 

 

 

 

R05X12

12

83

1000

DIP14

R05Y12

12

83

1000

SIP7

R05X13

12.75

78

1000

DIP14

R05Y13

12.75

78

1000

SIP7

5V and 12V input types

 

 

 

 

RxxX05

5

100

500

 

RxxX09

9

100

900

DIP14

RxxX12

12

83

1000

 

RxxX15

15

67

1000

 

RxxY05

5

100

500

 

RxxY09

9

100

900

SIP7

RxxY12

12

83

1000

 

RxxY15

15

67

1000

 

24V and 48V input types

 

 

 

 

RxxX05

5

100

500

 

RxxX09

9

100

900

DIP14

RxxX12

12

83

1000

 

RxxX15

15

67

1000

 

RxxY05

5

100

500

 

RxxY09

9

100

900

SIP7

RxxY12

12

83

1000

 

RxxY15

15

67

1000

 

Absolute Maximum Ratings Over Operating Free Air Temperature Range

Input Voltage VIN

5V types

7V

 

12V types

15V

 

24V types

28V

 

48V types

54V

Output Power Total

 

1W

Short Circuit Duration

 

1s

Maximum Ouput Voltage Rise Time (after control pin high)

 

35µs

Isolation Voltage (flash tested for 1 second)

 

1000VDC

Operating Free Air Temperature Range (requires a minimum of 10 mm air space around the component)

0°C to 70°C (see derating curve)

Storage Temperature Range

 

–55°C to 150°C

Lead Temperature (1.5 mm from case for 10 seconds)

 

300 °C

www.recom-international.com

 

EU 27

EUROLINE - DC/DC-Converter

RxxX and RxxY Series, 1 Watt, SIP7/DIP14, Regulated / Isolated (Single Output)

Typical Isolation Capacitance (pF)

Part Number

 

 

Output Voltage (V)

 

 

 

05

09

12

13

15

R05X/Yxx

28

32

33

31

39

R12X/Yxx

48

63

68

69

R24X/Yxx

84

106

132

152

R48X/Yxx

54

75

92

109

Electrical Specifications (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified)

Input Voltage Range VIN (continuous operation)

5V types

5V±5%

 

12V types

12V±5%

 

24V types

24V±5%

 

48V types

48V±5%

Load Voltage Regulation (10% load to 100% full load)

 

0.9% typ. / 1.5% max.

Line Voltage Regulation (depending on the Type)

 

0.25% / 1.0% of VIN

Output Voltage Accuracy (control pin open circuit)

 

±5%

Input Reflected Ripple (20MHz band limited)

 

40mVp-p max.

Output Ripple (20MHz band limited)

 

60mVp-p max.

Insulation Resistance (at 500VDC)

 

100MΩ min.

Efficiency (at full load)

5V output types

45% min. / 50% typ.

 

9V, 12V and 15V output types

55% min. / 62% typ.

Temperature Drift (VOUT)

 

0.03% per °C max.

Temperature Rise above Ambient (at full load)

 

8°C max.

Switching Frequency at Full Load (depending on the type)

 

80kHz typ.

Package Weight

SIP and DIP 5/12/24V types

2.3 g

 

SIP and DIP 48V types

2.9 g

MTTF 1) (depending on the type)

–25°C

165kHrs min. / 2406kHrs max.

 

+25°C

135kHrs min. / 1307kHrs max.

 

+70°C

69kHrs min. / 144kHrs max.

1). Calculated using MIL-HDBK-217F with nominal input voltage at full load.

 

 