EUROLINE - DC/DC-Converter
RxxVxx-Series, 2 Watt, DIP24, 6kVDC Isolation (Dual Output)
Features
● 6kVDC Isolation |
● MTTF up to 1.0 Million Hours |
● Efficiency to 80% |
● BS EN 60950 Certified |
● UL 94V-0 Package Material |
● Fully Encapsulated |
● Internal SMD Construction |
● UL1950 E196683 Recognised |
|
|
Selection Guide 5V, 12V Input types
Part Number |
Nom. Input |
Output |
Output |
Efficiency |
Isolation |
Package |
|
Voltage |
Voltage |
Current |
|
Capacitance |
Style |
|
(VDC) |
(VDC) |
(mA) |
(%) |
(pF) |
|
R05V05 |
5 |
±5 |
±200 |
74 |
1.8 |
|
R05V09 |
5 |
±9 |
±111 |
76 |
1.9 |
|
R05V12 |
5 |
±12 |
±83 |
77 |
2.0 |
|
R05V15 |
5 |
±15 |
±67 |
78 |
2.1 |
DIP24 |
R12V05 |
12 |
±5 |
±200 |
78 |
1.9 |
|
R12V09 |
12 |
±9 |
±111 |
81 |
2.0 |
|
R12V12 |
12 |
±12 |
±83 |
82 |
2.1 |
|
R12V15 |
12 |
±15 |
±67 |
82 |
2.2 |
|
Absolute Maximum Ratings
Input Voltage VIN |
05V types |
7VDC |
|
12V types |
15VDC |
Short Circuit Duration 1) |
|
1 s |
Internal Power Dissipation |
|
0.9W |
Lead Temperature 1.5 mm from Case for 10 seconds |
|
300°C |
Electrical Specifications (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified) |
||
Input Voltage Range VIN (continuous operation) |
5V types |
4.5VDC min. / 5.5VDC max. |
|
12V types |
10.8VDC min. / 13.2VDC max. |
Output Voltage Accuracy (see tolerance envelope) |
|
–7.5% min. / 10% max. |
Line Regulation (highVIN to low VIN) |
|
1.0% typ. / 1.0% of VIN |
Load Regulation (10% load to rated load) (depending on the type) |
|
6% min. / 12% max. |
Output Ripple (BW=DC to 20MHz, all output types) |
|
200mVp-p max. |
Isolation Voltage (flash tested for 1 second) |
|
6000VDC min. |
Resistance (Viso = 500VDC) |
|
10 GΩ min. |
Switching Frequency at Full Load (depending on the type) |
|
35kHz max. |
Package Weight |
|
7.5 g |
Operating Temperature Range |
|
0°C to +70°C |
Storage Temperature Range |
|
+50°C to +130°C |
Temperature Rise Above Ambient (all output types) |
|
+32°C max. |
MTTF 2) (depending on the type) |
– 0°C |
89kHrs min. / 961kHrs max. |
|
+25°C |
82kHrs min. / 747kHrs max. |
|
+85°C |
62kHrs min. / 311kHrs max. |
1). Supply voltage must be discontinued at the end of the short circuit duration |
|
|
2). Calculated using MIL-HDBK-217F with nominal input voltage at full load. |
|
|
EU 36 |
Updated: 6. Dec. 2001 |
www.recom-international.com |