Rane RS 1 User Manual

DATA SHEET
General Description
e RS 1 Remote Power Supply is a general purpose AC to AC adapter designed to power any Rane products equipped with red AC remote power mod jacks. And since the output voltage is classified as safety extra-low voltage, then all units powered from this unit are exempt from safety agency approval requirements.
Caution—ermal Switch Resetting
If the thermal protection switch is activated (due to short circuit, etc.):
1. Remove the AC mains power.
2. Wait 15 minutes for the thermal switch to reach ambient temperature and reset itself.
3. Reapply AC mains power.
Caution—Damage to the power supply will occur if this supply is plugged into older Rane products with DC (black color) power jacks. Use only with AC (red color) power jacks.
RS 1
120 VAC REMOTE POWER SUPPLY
Daisychaining Precautions: Daisychaining is acceptable
only where balanced wiring is used exclusively, and the total cur­rent demand of all products being powered does not exceed the maximum output current rating.
e connector wiring (see diagram) of the RS 1 allows for easy daisychaining. Plug a 6-wire modular wye adaptor (male to 2 females) into the first product to be powered. Connect the RS 1 output cable into one side of this adaptor, and then use another 6-wire mod cable from the other side of the adaptor to the next unit to be powered. IMPORTANT: BOTH THE ADAPTOR AND THE CABLE MUST BE 6-WIRE; 4-WIRE VERSIONS WILL NOT WORK.
Parameter Specifications Limit Units Conditions/Comments
Output Voltage 18 CT (center-tap: 9+9) 10% VAC Rated load, 120 VAC line Maximum Output Current 750 +10% mA Max/Min Output Voltage 23.3 CT/16.2 CT 10% VAC No-load/full-load, ±10% line Input Cord 2-Wire, 2-Prong AC Line Cord 18 AWG, 6 feet long Output Cord 6-Wire Modular RJ-12 Plug 26 AWG, 6 feet long Safety Agency Class 2 transformer
..........U.L. Listed E90493 & E88261 U.L. 1012
..........C.S.A. Certified LR91687 & LR58948 C.S.A. C22.2 No. 223
Maximum Power 25 W RS 1 Line Voltage 105-130 VAC, 50/60 Hz Enclosure Black High Impact Plastic With integral mounting tabs Weight 1.5 lb 0.7 kg
RS 1
CLASS II Double Insulated
Indoor Use Only
Safety Transformer
Thermal Switch
230 VAC REMOTE POWER SUPPLY
General Description
e RS 1 Remote Power Supply is a general purpose AC to AC adapter designed to power any Rane products equipped with red AC re­mote power mod jacks. e RS 1 meets the EN 60950 Safety Standard and complies with the European EMC directive 89/336/EEC. And since the output voltage is classified as safety extra-low voltage, then all units powered from this unit are exempt from safety agency approval requirements.
e 230VAC version of the RS 1 comes from the factory with an integral mounted Eurocord.
e table-top design of the RS 1, along with the 2-meter line cord and the two meter output cable, allows installation in any convenient location away from the powered unit and the AC outlet strip. Conve-
nient mounting tabs are integral to the rugged high impact housing.
DATA SHEET
Daisychaining Precautions: Daisychaining is acceptable only
where balanced wiring is used exclusively, and the total current demand of all products being powered does not exceed the maximum output
current rating.
e connector wiring (see diagram) of the RS 1 allows for easy dai-
sychaining. Plug a 6-wire modular wye adapter (male to 2 females) into the first product to be powered. Connect the RS 1 output cable into one side of this adapter, and then use another 6-wire mod cable from the other side of the adapter to the next unit. IMPORTANT: BOTH THE ADAPTER AND THE CABLE MUST BE 6-WIR E; 4-WIRE VERSIONS WILL NOT WORK.
Caution—ermal Switch Resetting:
If the thermal protection switch is activated (short circuit, etc.):
1. Remove the AC mains power.
2. Wait 15 minutes for the thermal switch to reach ambient tempera­ture and reset itself.
3. Reapply AC mains power.
Caution—Use only with Rane products with AC (red color) power jacks. Damage will occur into older DC (black color) power jacks. Finnish Note: Laitteen verkkoliitantajomtoa ei voi vaihtaa johdon viot-
tuessa on koko verkkomuuntaja johtoineen vaimdettava uuteen.
Swedish Note: Anslutningssladden till denna transformator kan icke
ersattas. Om sladden skadas skall darfor transformatorn kasseras.
Parameter Specifications Limit Units Conditions/Comments
Output Voltage 2x9 CT (center-tap: 9+9) 10% VAC Rated load, 230 VAC line Maximum Output Current 750 +10% mA Max/Min Output Voltage 23.3 CT/16.2 CT 10% VAC No-load/full-load, ±10% line Input Cord Class II, CEE 7/16 Eurocord, 2 meters long Output Cord 6-Wire Modular RJ-12 Plug 26 AWG, 2 meters long Safety Agency Class II transformer
..........EMC European Directive 89/336/EEC E1 and E2 environments
..........IEC Meets EN 60950-1:2001 & EN 60065:2002 TUV approved with GS mark
..........Scandinavian Approved Semko
Maximum Power 20 W Line Voltage 190-250 VAC, 50/60 Hz Enclosure Black High Impact Plastic With integral mounting tabs Weight 0.7 kg
©Rane Corporation 10802 47th Ave. W., Mukilte o WA 98275-5 098 TEL 425-3 55-60 00 FAX 425-347-77 57 WEB www.rane.co m