Quikserv BP-7241E-IP Installation Manual

FIG. A
CONTRACTOR)
(SUPPLIED BY
JUNCTION BOX
TOP VIEW
115V- POWER SUPPLY
EYE WIRE
TO BE SUPPLIED
ANCHOR SCREWS
CAUTION: POWER SUPPLY IS LOCATED
DRILL THRU CENTER WITH CAUTION
IN LEFT-HAND JAMB - PLEASE
CABLE
FIG. D
EYE WIRE
CABLE
EYE BAR SENSOR
110 Volt Power Source
Eye Wire Cable
Eye Set to Be Mounted In Middle Of Service Opening
EYE BAR
SIDE VIEW
Drawing Name: Scale:
Rev.Drawn By:
Quikserv Corp.
1-800-388-8307 www.quikserv.com
Date:
BP-7241E-IP TB Installation Drawing
9/25/2014
BC
N/A
BP-7241E-IP THRU-BEAM INSTALLATION DRAWING
Rough Opening:
Actual Dimension:
Service Opening:
NOTE:THIS DRAWING EMBODIES A CONFIDENTIAL PROPRIETY DESIGN ORIGINATED AND OWNED BY QUIKSERV CORP., AND IS SUBMITTED UNDER A CONFIDENTIAL
RELATIONSHIP. ALL PATENT, MANUFACTURING, SALE RIGHTS REGARDING THE SAME ARE RESERVED EXCEPT TO THE EXTENT RIGHTS ARE EXPRESSLY GRANTED TO
OTHERS. THE RECIPIENT AGREES BY ACCEPTING THESE DRAWINGS NOT TO SUPPLY OR DISCLOSE ANY INFORMATION REGARDING THEM TO ANY UNAUTHORIZED PERSON.
72-1/2" (W) X 41-1/2" (H)
72" (W) X 41" (H)
27-1/4" (W) X 27" (H)
BY CERTIFIED ENGINEER.
LOCATED IN LEFT SIDE JAMB. (SEE FIG. A)
SCHEDULE.
3) ANCHOR PER FLORIDA BLDG. CODES ANCHOR
10) ALL OTHER TYPE OF ANCHORING TO BE APPROVED
TO BE 36". (CHECK ANY AND ALL LOCAL OR CITY CODES)
7) RECOMMENDED HEIGHT FROM FLOOR TO SERVICE OPENING
5) CAUTION WHEN DRILLING - EYE WIRE CABLE IS
2) ANCHOR SCREWS TO BE SUPPLIED BY CONTRACTOR.
SQUARE TO WORK PROPERLY.
1) QUIKSERV WINDOWS MUST BE INSTALLED LEVEL AND
TYPICAL
BP-7241E-IP THRU-BEAM
9) SILICONE ALL EXTERIOR AND INTERIOR JOINTS.
4) CAUTION WHEN DRILLING-115V POWER SUPPLY WIRE LOCATED IN LEFT SIDE JAMB. (SEE FIG. A)
6) 115V/15AMP DEDICATED CIRCUIT REQUIRED.
INSTALLATION
OPENING. (BAR IS TO BE MOUNTED ON THE WALL)
8) MOUNT EYE BAR TO WALL DIRECTLY BELOW SERVICE