POWEREX P1Z7ABR700W, P2Z7ABB700W, P3Z7ABT700W, P3Z9AAT900W, P3Z9ABT900W Datasheet

...
0 (0)

 

POW-R-BRIK™

 

 

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Phase Control Modules

 

345-800 Amperes/400-3000 Volts

OUTLINE DRAWING

 

 

 

MARKING: DEVICE

 

 

 

AND DIRECTION

 

 

 

ACCORDING TO CIRCUIT

 

L TYP. 4 PLACES

 

CONFIGURATION CHART

 

 

 

 

 

G TAPPED HOLE

C

 

 

 

 

 

x 0.50 DEEP

 

MARKING: K1

 

TYP. 3 PLACES

C

AI/K2 (ANODE)/(CATHODE),

 

AND A2 (ANODE) AS SHOWN

 

L

K1

X2

A2

 

C

 

D

B

L

 

 

 

F F

A

MARKING: STYLE NO. WITH DATE CODE & MFG. LOCATION CODE (CUSTOMER PART NO. OPTIONAL)

E Ø THRU HOLE TYP. 4 PLACES (FOR TYP. 1/4-20 SOCKET HD. SCR.)

(& BELLEVILLE SPRING WASHER)

GATE (WHITE) & CATHODE

 

 

 

 

 

 

 

 

 

SENSOR (WHITE) LEADS

 

(RED) LEADS 12.5" LONG

 

 

 

 

 

 

 

 

 

12.5 ±0.5" LONG WITH

 

WITH 0.375" LONG

 

 

 

 

 

 

 

 

 

0.375" IN LONG STRIPED ENDS

 

STRIPPED ENDS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

THIS SURFACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CASE ANODIZED PER

 

 

 

 

L

 

MUST BE PROTECTED

 

MIL-A-8625, TYPE II

 

 

 

 

 

 

 

 

 

 

 

 

 

AND NOT DAMAGED

 

 

 

 

 

 

 

 

 

 

 

Outline Drawing

 

 

 

 

 

 

 

 

 

Z7A Outline

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimension

Inches

Millimeters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

6.30

 

 

 

 

 

 

 

153.16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

3.02

 

 

 

 

 

 

 

76.70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

3.15

 

 

 

 

 

 

 

80.01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

2.47

 

 

 

 

 

 

 

62.73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

0.328 Dia.

 

 

Dia. 8.33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

1.83

 

 

 

 

 

 

 

46.48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

5/16-18

 

 

 

 

 

5/16-18

 

 

 

 

 

 

 

 

UNC-2B

 

UNC-2B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

1.27

 

 

 

 

 

 

 

32.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

2.09

 

 

 

 

 

 

 

53.08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

2.25

 

 

 

 

 

 

 

57.15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

0.56

 

 

 

 

 

 

 

14.22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Bolt (E) Torque Limit is 11 ft.-lb.

Electrical terminal (G) torque limit is 11 ft.-lb. for type Z7A and 20 ft.-lb. for Z9A.

Apply a thin coating of thermal joint compound to heat sink surface prior to module mounting.

Module weights: Z7A weighs 6 lbs. while the Z9A module weighs 11 lbs.

If incoming tests are done for isolation voltage, the voltage should be applied in a slow manner rather than abruptly imposed on the device. The voltage should be applied between the top terminals, which must be shorted together, and the metal case.

The metal case is anodized and provides added voltage isolation capability if not damaged: factory hi-pot test is achieved without the benefit of the anodized coating.

POW-R-BRIK™

Phase Control Modules

345-800 Amperes/400-3000 Volts

Z9A Outline

Dimension

Inches

Millimeters

A

7.50

190.50

 

 

 

B

3.70

93.98

 

 

 

C

3.15

80.01

 

 

 

D

3.15

80.01

 

 

 

E

0.328 Dia.

Dia. 8.33

 

 

 

F

2.03

51.56

 

 

 

G

3/8-16

3/8-16

 

UNC-2B

UNC-2B

 

 

 

H

1.51

38.35

 

 

 

J

2.52

64.00

 

 

 

K

2.75

69.85

 

 

 

L

0.56

14.22

 

 

 

Ordering Information:

Select the complete thirteen digit module part number you desire from the Configuration Reference Description.

Example: P3Z7ACT700W16 is a 1600 Volt, 375 Ampere Average, Dual SCR POW-R-BRIK™ Module with the standard thermistor.

Description:

Powerex POW-R-BRIK™ Modules are designed for medium and high current power control applications. POW-R-BRIK™ Modules feature an electrically isolated package that simplifies system packaging, installation and cooling. POW-R-BRIK™ Modules utilize Compression Bonded Encapsulation (CBE) mounting and double side cooling of the semiconductor elements. The Z7A outline POW-R-BRIK™ uses 33mm or 38mm elements and the Z9A outline POW-R-BRIK™ uses 50mm elements. Standard circuit configurations include Dual SCR, Dual Diode, SCR/Diode, and Diode/SCR. Additional circuit configurations, e.g. Single Element, Common Cathode, Common Anode, and special element types, e.g. Fast Switch SCRs, Fast Recovery Diodes, GTOs, and Transistors are available.

Features:

MElectrically Isolated Packaging

MAnodized Aluminum Housing

MInternal Copper Contacting

MGold Element Contacting

MInternal Temperature Sensor

MCompression Element Contacting

Applications:

MAC Motor Starters

MDC Motor Controls

MResistance Welding Controls

MMining Power Centers

MHigh Voltage Motor Starters

MTransportation Systems

P-1

POWEREX P1Z7ABR700W, P2Z7ABB700W, P3Z7ABT700W, P3Z9AAT900W, P3Z9ABT900W Datasheet

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

POW-R-BRIK™

Phase Control Modules

345-800 Amperes/400-3000 Volts

Configuration Reference:

The POW-R-BRIK™ part number system takes the form P3 Z7A CT7 00 W16 where:

P3 is the configuration number. The configurations are shown pictorially in the right hand column.

Z7A is the package type per the outline drawings Z7A and Z9A on this data sheet.

CT7 denotes the element code. The Element Code Reference at the end of this data sheet provides information on the standard element codes including the corresponding disc device using the element. Refer to the appropriate disc package data sheets in the Powerex Semiconductor Data Book for additional device specifications.

00 denotes special features:

00 – module includes standard thermistor XT – no thermistor

AA-ZZ – denotes unique customer specification

W16 denotes voltage code per the table below. Note that not all voltage ratings are available for every element. Refer to the Element Code Reference for available voltage ranges for a given element.

Elements

Voltage

Circuit Configurations:

Voltage Rating

Code

P1

- DIODE

 

400

V04

P4

- FAST DIODE*

 

 

 

 

600

V06

 

 

 

800

V08

 

 

S

1000

W10

 

 

 

1200

W12

 

Element 1

Element 2

 

 

 

1400

W14

 

 

 

1600

W16

P2

- SCR/DIODE

 

P5

- FAST SCR/FAST DIODE*

 

 

 

 

1800

W18

 

 

 

2000

W20

 

 

S

 

 

 

 

2200

W22

 

 

 

2400

W24

 

 

 

2600

W26

 

Element 1

Element 2

 

 

 

2800

W28

P3

- SCR/SCR

 

P6

- FAST SCR/FAST SCR*

 

 

 

 

3000

W30

 

 

 

 

 

 

 

S

 

 

 

Element 1

Element 2

 

 

P7

- DIODE/SCR

 

 

 

P8

- FAST DIODE/FAST SCR*

 

S

Element 1

Element 2

* Consult Factory for Available Ratings.

P-2

Loading...