LOW NOx TURBOPOWER® • PACKAGED WATER HEATER

POLYSHIELD® POLYMER-LINED STORAGE TANK

TANK SERIES 1250 GALLONS VERTICAL

MODEL

Recovery gph c

INPUT

Min. Inlet

SCAQMD Energy

Dimensions

 

Blower

Shipping

Flow Gas

 

(inches)

 

Motor

Weight

 

 

 

 

NUMBER

40° - 120°F

40° - 140°F

Btu/h

Pressure

Model No.

A

 

B

C

HP

 

Amps

#

 

 

" W.C. d

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000 P 1250A-TPL

1000

800

800,000

4.5

8TPL

800 MBtu/h

33

 

8

1

1/2

 

7

4570

1500 P 1250A-TPL

1500

1200

1,200,000

4.5

12TPL

1200 MBtu/h

33

 

8

1-1/4

1

 

14

4580

c Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss. d With standard gas train

*The information presented is for natural gas 0.6 S.G. Dimensions are in inches unless otherwise specified.

For standard and optional equipment, see form #PV 6453.

STANDARD GAS PRESSURE REQUIREMENTS:

SEE TABLE FOR MINIMUM PRESSURE BY MODEL. MAXIMUM STATIC INLET GAS PRESSURE IS 10.5" W.C.

FOR GAS PRESSURES OUTSIDE OF THIS RANGE,

CONTACT YOUR PVI REPRESENTATIVE.

VENTING REQUIREMENTS:

-.02" TO -.06" W.C. (NEGATIVE PRESSURE).

TYPE B VENTING.

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY. CHECK NATIONAL FUEL GAS CODE UNDER "FAN ASSISTED."

STANDARD ELECTRICAL REQUIREMENTS:

VOLTAGE: 120V, 1Ø, 60 HZ., 20 AMPS.

OTHER VOLTAGES REQUIRE AN EXTERNAL

STEPDOWN TRANSFORMER.