Promise Technology J610S, J310S User Manual

Page 1
VT
RAK
J610S, J310
P
RODUCT
M
Version 1.1
S
Page 2
VTrak J610s, J310s Product Manual
Copyright
© 2007 Promise Technology, Inc. All Rights Reserved.
Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted in any form without the expressed, written permission of Promise Technology.
Trademarks
Promise, and the Promise logo are registered in U.S. Patent and Trademark Office. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies.
Important data protection information
You should back up all data before installing any drive controller or storage peripheral. Promise Technology is not responsible for any loss of data resulting from the use, disuse or misuse of this or any other Promise Technology product.
Notice
Although Promise Technology has attempted to ensure the accuracy of the content of this manual, it is possible that this document may contain technical inaccuracies, typographical, or other errors. Promise Technology assumes no liability for any error in this publication, and for damages, whether direct, indirect, incidental, consequential or otherwise, that may result from such error, including, but not limited to loss of data or profits.
Promise Technology provides this publication “as is” without warranty of any kind, either express or implied, including, but not limited to implied warranties of merchantability or fitness for a particular purpose.
The published information in the manual is subject to change without notice. Promise Technology reserves the right to make changes in the product design, layout, and driver revisions without notification to its users.
This version of the Product Manual supersedes all previous versions.
Recommendations
In this Product Manual, the appearance of products made by other companies, including, but not limited to software, servers and disk drives, is for the purpose of illustration and explanation only. Promise Technology does not recommend, endorse, prefer, or support any product made by another manufacturer.
ii
Page 3

Contents

Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Architectural Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Warranty and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
CE Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
GOST-R Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
IRAM Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
MIC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Chapter 2: Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Unpacking the VTrak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Mounting VTrak J610s in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Mounting VTrak J310s in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Installing Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Drive Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Setting Up Data Cable Connections . . . . . . . . . . . . . . . . . . . . . . . .20
Basic DAS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Cascading DAS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Redundant DAS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Setting Up Serial Cable Connections . . . . . . . . . . . . . . . . . . . . . . .27
Connecting the Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Setting Up the CLI Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Chapter 3: Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Front Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Drive Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
I/O Module Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
CLI Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Cable Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Enclosure Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Information List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Viewing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Settings List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Making Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Help Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Link Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
iii
Page 4
VTrak J610s, J310s Product Manual
Chapter 3: Management, cont.
CLI Command Set, cont.
Viewing Link Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Clearing the Error Count . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Route Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Route Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Uptime Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
VPDR Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
? Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Chapter 4: Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Contacting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Returning Product For Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Appendix A: Second I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
iv
Page 5

Chapter 1: Introduction

About This Manual (below)
Overview (page 2)
Architectural Description (page 4)
Features and Benefits (page 5)
Specifications (page 6)
Thank you for purchasing Promise Technology’s VTrak J610s or J310s external disk array subsystem.

About This Manual

This Product Manual describes how to setup, use and maintain the VTrak J610s or J310s external disk subsystem. It also describes how to use the built-in command-line interface (CLI) software.
This manual includes a full table of contents, index, chapter task lists and numerous cross-references to help you find the specific information you are looking for.
Also included are four levels of notices:
Note
A Note provides helpful information such as hints or alternative ways of doing a task.
Important
An Important calls attention to an essential step or point required to complete a task. Important items include things often missed.
Caution
A Caution informs you of possible equipment damage or loss of data and how to avoid them.
Warning
A Warning notifies you of probable equipment damage or loss of data, or the possibility of physical injury, and how to avoid them.
1
Page 6
VTrak J610s, J310s Product Manual

Overview

The Promise VTrak J610s and J310s are optimized for organizations deploying cost-effective small-to-medium application clusters, disk-to-disk backup and midrange storage solutions.
Figure 1. VTrak J610s front view
Drive Carrier LEDs
Drive Carriers Power and Status LEDs
Figure 2. VTrak J310s front view with bezel removed
Drive Carrier LEDs
Drive Carriers Power and Status LEDs
The dual 3Gb SAS host interface ports offer the ease of management and performance required by companies running popular departmental and back­office applications including file/print, e-mail, database and Web services
2
Page 7
Figure 3. VTrak J610s rear view
Chapter 1: Introduction
I/O module 2I/O module 1
Power Supply 1
115200
8 N 1
Cooling Unit 1
Cooling Unit 2
Power Supply 2
115200
8 N 1
Figure 4. VTrak J310s rear view
Power Supply 1
I/O module 1
Cooling Unit 1
O
I
Cooling Unit 2
115200
8 N 1
Power Supply 2
I/O module 2
O
I
115200 8 N 1
The two external SAS ports provide the needed connectivity and bandwidth for large capacity solutions requiring multiple JBOD boxes cascaded together while still providing dual server support and host port failover or aggregation.
3
Page 8
VTrak J610s, J310s Product Manual

Architectural Description

The VTrak J610s packs up to 16 drives per system, offering industry-leading capacity in just 3U of standard 19-inch rack space. The VTrak J310s supports up to 12 drives per system, in just 2U of standard 19-inch rack space. The J610s and J310s unit’s compact form factor maximizes density, increasing capacity per unit of rack space.
Multiple J610s and J310s systems can also be connected to the same server using standard SAS features to deliver massive storage to capacity hungry applications such as disk-to-disk backup, media archiving, video surveillance and compliance storage
Promise has designed the J610s and J310s chassis to be fully compatible with all future Promise external storage products. By using the same chassis, drive carriers, and cooling units, upgrading the RAID controllers and JBOD modules is fast and simple.
With the VTrak J610s and J310s, Promise has dramatically narrowed the gap between simple fault tolerance and No Single Point of Failure. The VTrak J610s and J310s use a fully redundant, hot-swap design and continuously monitors all system components. It can withstand failures to disks, power supplies, cooling and I/O modules without interrupting system operation.
4
Page 9
Chapter 1: Introduction

Features and Benefits

Feature Benefit
3U or 2U 19-inch wide enclosure Installs easily in any standard rackmount.
Supports Serial Attached SCSI disk drives
Supports Serial ATA disk drives Allows you to use your legacy SATA disk
Hot-swap feature for drive carriers, I/O modules, power supplies and fans
Tool-less field-replaceable units (FRUs)
Complete cable-less design All components easily plug directly into
Redundant, hot-swappable cooling units
Redundant, hot-swappable power supplies
Dual, active/active I/O Modules High level of availability even with a failed
One expansion SAS port I/O module
Allows you to use the new dual-port SAS disk drives.
drives.
Allows a defective component to be replaced without interrupting data accessibility to the host system.
All FRUs can be replaced without tools, saving time and effort for support personnel.
boards. No cables to complicate setup or maintenance.
Load sharing and full operation even with multiple failed fans.
Load sharing and full operation even with a failed power supply.
I/O module.
Enables cascading JBOD subsystems.
Command-line interface Control and monitoring with simple,
straightforward interface.
Management through in-band SAS or serial port
Compatible with leading SAS HBA and RAID cards
Choice of local or network management options
Easy, works-the-first-time connections with your current systems
5
Page 10
VTrak J610s, J310s Product Manual

Specifications

Drive Capacity: J610s, 16 drives. J310s, 12 drives.
External I/O Ports: SAS host port and SAS expansion port.
Supported Disk Interfaces: Serial Attached SCSI (SAS) and Serial ATA (SATA), 3Gb/s and 1.5Gb/s
Supported Operating Systems:
Windows Vista, Business, Enterprise, or Ultimate
Windows 2003 Server
Windows XP Professional
Windows 2000
The list above refers to 32-bit and 64-bit versions of the OS in the Host PC or server. The actual OS support depends upon your SAS HBA or RAID adapter. Check your SAS HBA or RAID adapter user documentation.
Voltage: 100–240 VAC Auto-ranging.
Current: 8 A @ 100 VAC; 4 A @ 240 VAC Current rating with two power cords
Power Consumption (not including disk drives):
J610s, 108.38 W.
J310s, 100.87 W.
Power Consumption (including disk drives):
J610s, 523.91 W.
J310s, 412.51 W.
Power Supply:
J610s, Dual 500W, 100–240 VAC auto-ranging, 50–60 Hz, dual hot swap and redundant with PFC, N+1 design.
J310s, Dual 400W, 100–240 VAC auto-ranging, 50–60 Hz, dual hot swap and redundant with PFC, N+1 design.
Operating Temperature:
5° to 40°C operational
-40° to 60°C non-operational
Relative Humidity: Maximum 95%
RedHat Linux
SuSE Linux
Novell Netware
Sun Solaris
Vibration: Random, 0.21 grms, 5 to 500 Hz, 30 Mins, X, Y, Z axis
6
Page 11
Chapter 1: Introduction
Dimensions (H x W x D):
J610s, 13.1 x 44.7 x 56.1 cm (5.2 x 17.6 x 22.1 in)
J310s, 8.8 x 44.7 x 56.1 cm (3.5 x 17.6 x 22.1 in)
Net Weight:
J610s, 30.5 kg (67.2 lb) without drives, 38.5 kg (84.9 lb) with 16 drives, assuming
0.5 kg (1.1 lb) per drive.
J310s, 26.5 kg (58.4 lb) without drives, 32.5 kg (71.7 lb) with 12 drives, assuming
0.5 kg (1.1 lb) per drive.
Gross Weight (including carton):
J610s, 37.5 kg (82.7 lb) without drives.
J310s, 33.0 kg (72.8 lb) without drives.
Safety: CE, FCC Class A, VCCI, C-Tick, cUL, TUV, CB, BSMI, MIC.

Warranty and Support

Warranty: Three years complete system limited warranty.
Support: 24x 7 email and phone support (English only). 24x7 access to Promise support site for drivers, firmware, and compatibility.

CE Statement

Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

GOST-R Statement

ɉɪɟɞɭɩɪɟɠɞɟɧɢɟ. Ⱦɚɧɧɵɣ ɩɪɨɞɭɤɬ ɨɬɧɨɫɢɬɫɹ ɤ ɤɥɚɫɫɭ A. ȼ ɞɨɦɚɲɧɢɯ ɭɫɥɨɜɢɹɯ ɨɧ ɦɨɠɟɬ ɛɵɬɶ ɩɪɢɱɢɧɨɣ ɜɨɡɧɢɤɧɨɜɟɧɢɹ ɪɚɞɢɨɩɨɦɟɯ, ɜ ɷɬɨɦ ɫɥɭɱɚɟ ɩɨɥɶɡɨɜɚɬɟɥɸ, ɜɨɡɦɨɠɧɨ, ɩɨɬɪɟɛɭɟɬɫɹ ɩɪɢɧɹɬɶ ɫɨɨɬɜɟɬɫɬɜɭɸɳɢɟ ɦɟɪɵ.
7
Page 12
VTrak J610s, J310s Product Manual

IRAM Statement

Advertencia: Este es un producto de clase A. En un ambiente doméstico, este producto puede causar interferencia de las ondas de radio, en cuyo caso se podría requerir que el usuario tome las medidas adecuadas.

MIC Statement

8
Page 13

Chapter 2: Installation

Unpacking the VTrak (below)
Mounting VTrak J610s in a Rack (page 11)
Mounting VTrak J310s in a Rack (page 13)
Installing Disk Drives (page 16)
Setting Up Data Cable Connections (page 20)
Setting Up Serial Cable Connections (page 27)
Connecting the Power (page 28)
Setting Up the CLI Connection (page 29)

Unpacking the VTrak

The VTrak J610s or J310s box contains the following items:
VTrak J610s or J310s Unit
•Quick Start Guide
Front bezel and key (J310s only)
RJ11-to-DB9 serial data cable (Units with one I/O module: 1) (Units with two I/O modules: 2)
1.0m (3.3 ft) SFF-8088 4X to 4X external SAS cable (Units with one I/O module: 1) (Units with two I/O modules: 2)
The electronic components within the VTrak are sensitive to damage from Electro-Static Discharge (ESD). Observe appropriate precautions at all times when handling the VTrak or its subassemblies.
Screws for disk drives (J610s: 70, including 6 spares) (J310s: 50, including 2 spares)
Left and right mounting rails
Left and right center-mount brackets
1.5m (4.9 ft) Power cords (2)
•CD with Product Manual and Quick
Start Guide
Warning
9
Page 14
VTrak J610s, J310s Product Manual
Figure 1. VTrak J610s rear view
I/O module 2I/O module 1
Power Supply 1
115200
8 N 1
Cooling Unit 1
Cooling Unit 2
Power Supply 2
115200
8 N 1
Figure 2. VTrak J310s rear view
Power Supply 1
I/O module 1
Cooling Unit 1
O
I
Cooling Unit 2
115200
8 N 1
Power Supply 2
I/O module 2
O
I
115200 8 N 1
Some VTraks ship with a single I/O module and a blank unit installed in the place of the second I/O module. You can upgrade your VTrak by installing a second I/O module. See page 53.
Some VTraks ship with a single power supply and an auxiliary cooling unit installed in the place of the second power supply to provide a comparable level of air circulation inside the enclosure.
10
Page 15
Chapter 2: Installation

Mounting VTrak J610s in a Rack

The J610s subsystem installs to the rack using the supplied mounting rails. You can also use your existing rails.
Figure 3. VTrak J610s mounted in a rack with the supplied rails
Vertical Rack Post VTrak J610s
Handles mount outside the rack post
At least two persons are required to safely lift, place, and attach the VTrak subsystem into a rack system.
Do not lift or move the VTrak subsystem by the handles, power supplies or the controller units. Hold the subsystem itself.
Do not install the VTrak subsystem into a rack without rails to support the subsystem.
Only a qualified electrician who is familiar with the installation procedure should mount and install the VTrak subsystem.
Be sure all switches are OFF before installing the VTrak subsystem or exchanging components.
To install the J610s subsystem into a rack with the supplied mounting rails:
1. Check the fit of the mounting rails in your rack system. See Figure 4.
2. Adjust the length of the mounting rails as needed.
3. Attach the mounting rail assemblies to the outside of the rack posts, using the attaching screws from your rack system.
Be sure the support is on the bottom facing inward.
Mounting rails (included) mount outside the rack post
Cautions
11
Page 16
VTrak J610s, J310s Product Manual
4. Square the rail assemblies in the rack.
5. Tighten the adjustment screws and the attaching screws.
6. Place the VTrak subsystem onto the rails.
7. Secure the VTrak subsystem to the rack through each handle, using the attaching screws from your rack system.
Figure 4. Rack mount assembly diagram
Rack front post
Inside of post
Rail attaching screw (not included)
Front rail
Rail adjustment screw
Rack back post
Rail attaching screw (not included)
Rear rail
Flange
Support
Rail adjustment screw
Inside of post
12
Page 17
Chapter 2: Installation

Mounting VTrak J310s in a Rack

The J310s subsystem installs to the rack using the supplied mounting rails. You can also use your existing rails.
Figure 5. VTrak J310s mounted in a rack with the supplied rails
Vertical Rack Post
Handles mount outside the rack post
At least two persons are required to safely lift, place, and attach the VTrak subsystem into a rack system.
Do not lift or move the VTrak subsystem by the handles, power supplies or the controller units. Hold the subsystem itself.
Do not install the VTrak subsystem into a rack without rails to support the subsystem.
Only a qualified electrician who is familiar with the installation procedure should mount and install the VTrak subsystem.
Be sure all switches are OFF before installing the VTrak subsystem or exchanging components.
VTrak J310s
Mounting rails (included) mount outside the rack post
Cautions
To install the VTrak subsystem into a rack with the supplied mounting rails:
1. Check the fit of the mounting rails in your rack system. See Figure 7.
2. Slide the plates out of the mounting rails.
3. Attach one plate to each side of the VTrak subsystem.
Line-up the six holes in the plate with the corresponding holes in the subsystem. Attach each plate with six screws (included). See Figure 6.
4. Slide one of the rails over the plate on one side of the enclosure.
13
Page 18
VTrak J610s, J310s Product Manual
The rail is designed to slide freely over the plate.
5. Attach a flange to each end of the rail, with the rail on the opposite side of the flange from the two-hole bracket.
6. Install the rail adjustment screws (included) through the flange into the rail.
There are four screws for each flange. See Figure 7.
7. Place the subsystem with mounting rails into your rack system.
8. Attach the mounting rail assemblies to the outside of the rack posts, using the attaching screws from your rack system.
9. Square the rail assemblies in the rack.
10. Tighten the adjustment screws and the attaching screws.
11. Place the VTrak subsystem onto the rails.
12. Secure the VTrak subsystem to the rack through each handle, using the attaching screws from your rack system.
Figure 6. Sliding flange installation
Rear (connector end) of the subsystem
VTrak J310s
14
Sliding plate
Screws (6 each side)
Page 19
Figure 7. Mounting rail installation
Chapter 2: Installation
Rack front post
Rail attaching screw (not included)
Inside of post
Rack back
Rail adjustment screw
Mounting Rail
Sliding plate
Rail attaching screw (not included)
Inside of post
15
Page 20
VTrak J610s, J310s Product Manual

Installing Disk Drives

Populate the VTrak with 3.5-inch SAS or SATA disk drives.
Install all of the drive carriers into the VTrak enclosure to ensure proper airflow, even if you do not populate all the carriers with disk drives.
Caution
Use only the counter-sink screws supplied with the VTrak. Use of other types of screws can damage the enclosure or the adjacent drives.
Figure 8. Drive carrier mounting holes
AAMUX Mounting Holes
Disk Drive Mounting Holes with AAMUX
WARNING:
Counter-sink screws only.
Disk Drive Mounting Holes without AAMUX
1. Remove the front bezel (J310s only).
2. Remove a disk drive carrier.
3. Optional. The AAMUX adapter is recommended for SATA disk drives used with VTraks with two I/O modules, so that both modules can access a SATA disk drive.
Place the optional AAMUX into the disk drive carrier and attach it with the four screws.
Install only the screws supplied with the AAMUX.
The AAMUX fits into the carrier with the SAS connector at the back. See
Figure 10.
Snug each screw. Be careful not to over tighten.
4. Carefully lay the drive into the drive carrier at the front, so that the screw holes on the bottom line up.
16
Page 21
Chapter 2: Installation
If you installed an AAMUX, lay the SATA disk drive in the carrier and slide it so the power and data connectors insert in to the AAMUX. See Figure 10.
5. Insert the screws through the holes in the drive carrier and into the bottom of the disk drive. See Figure 8.
Install only the screws supplied with the VTrak.
Install four screws per drive.
Snug each screw. Be careful not to over tighten.
6. Reinstall the drive carrier into the VTrak chassis.
7. Repeat steps 2 through 5 until all of your disk drives are installed.
8. Replace the front bezel.
Figure 9. Drive carrier with SAS disk drive
SAS Disk Drive
17
Page 22
VTrak J610s, J310s Product Manual
Figure 10.Drive carrier with SATA disk drive and AAMUX
SATA Disk Drive
AAMUX adapter SAS connector
Cautions
If you plan to operate your VTrak with fewer than a full load of disk drives, install all of the drive carriers into the enclosure, to ensure proper airflow for cooling.
A VTrak J610s or J310s carrier is similar in appearance but is NOT interchangeable with a VTrak M500f/i/p drive carrier.
Important
Be sure each drive is securely fastened to its carrier. Proper installation ensures adequate grounding and minimizes vibration. Do not install drives with fewer than four screws.
18
Page 23
Chapter 2: Installation

Drive Numbering

Each disk drive in the J610s or J310s unit is identified by a number that corresponds to the Port number used for management. See “Link Command” on page 40.
Numbers are stamped above each drive bay for easy identification.
Figure 11.VTrak J610s drive slot numbering
1234
65
9101112
13
Figure 12.VTrak J310s drive slot numbering
14
7
15
8
16
123
65
91011
19
7
4
8
12
Page 24
VTrak J610s, J310s Product Manual

Setting Up Data Cable Connections

VTraks provide Direct Attached Storage (DAS) support to the Host PC.
Figure 13. VTrak J610s has one or two I/O modules
I/O module 1 (default primary)
I/O module 2
115200
8 N 1
115200
8 N 1
Figure 14.VTrak J310s has one or two I/O modules
O
I
I/O module 1
115200
8 N 1
I/O module 2
O
I
115200 8 N 1
(default primary)
There can be one or two Input Output Modules (I/O modules) on the VTrak.
If your VTrak has two I/O modules, I/O module 1 (on the left) is the default primary.
If your VTrak has only one I/O module, that I/O module is the default primary.
Under SAS specifications, both I/O modules are active at the same time. The terms primary and secondary are for enclosure management purposes only. To verify which I/O module is the default primary, see “Enclosure Command” on page 36.
20
Page 25
Chapter 2: Installation
Figure 15.I/O modules have a circle-icon port and a diamond-icon port
115200
8 N 1
Diamond-icon port (CN2) LED
Circle-icon port (CN1) LED
I/O Module Status LED
Each I/O module has one circle-icon port and one diamond-icon port.
In the CLI command set, the circle-icon port is called CN1 and the diamond-icon port is called CN2. See “CLI Command Set” on page 35.
Note
SAS HBA cards are User-supplied items. They are not included with the VTrak unit.
21
Page 26
VTrak J610s, J310s Product Manual

Basic DAS Connection

Figure 16. An example of a basic DAS connection between one Host PC and one VTrak J310s unit. The J610s is similar
Connect to either data port
O
I
115200 8 N 1
O
I
115200 8 N 1
VTrak J310s
SFF-8088 external 4X to 4X SAS cable
SAS HBA Card
PC
The arrangement above is the minimum DAS system with a single SAS HBA card in the Host PC. Connect the SAS HBA card to either port of the I/O module on the VTrak.
Use a SFF-8088 4X to 4X external SAS cable (supplied with the VTrak).
Because the Host SAS HBA card is an end device, you can connect it to either SAS data port on the VTrak.
22
Page 27
Chapter 2: Installation

Cascading DAS Connection

If you have multiple VTraks and want to manage them from the same SAS HBA card in the Host PC, connect the VTraks in a cascade. See Figure 17.
To setup a cascading DAS connection:
1. Connect the SAS HBA card in the Host PC to either of the SAS ports, circle­or diamond-icon) on the I/O module of the first VTrak.
Use a SFF-8088 4X to 4X external SAS cable (supplied with the VTrak).
2. Connect the remaining port on the same I/O module of the first VTrak to the I/O module of the next VTrak.
Be sure to connect circle icon to diamond icon or vice versa.
Use a SFF-8088 to SFF-8088 SAS cable to connect the VTraks.
You can cascade up to four VTraks in this manner. You can mix J610s and J310s units in the same cascade.
23
Page 28
VTrak J610s, J310s Product Manual
s
s
Figure 17. Two examples of cascaded DAS connections between one Host PC and two VTrak J310s units. The J610s is similar
SAS HBA Card
SFF-8088 external 4X to 4X SAS cable
CN1
CN2
Cascade Configuration 1 Cascade Configuration 2
SFF-8088 to SFF-8088
PC
SAS cable
CN2
O
I
115200 8 N 1
O
I
VTrak J310
115200 8 N 1
CN1
O
I
115200 8 N 1
O
I
VTrak J310
115200 8 N 1
24
Page 29
Chapter 2: Installation

Redundant DAS Connection

A fully redundant arrangement requires:
Two VTrak J610s or J310s units with dual I/O modules
Two Host PCs with a SAS HBA card in each PC
Each HBA card connects to a different I/O module in the first VTrak, to provide a separate cascade. See Figure 18.
To setup a redundant DAS connection:
1. Connect the SAS HBA card in the first Host PC to either of the SAS ports, circle- or diamond-icon) on the first I/O module of the first VTrak.
Use a SFF-8088 4X to 4X external SAS cable (supplied with the VTrak).
2. Connect the SAS HBA card in the second Host PC to either of the SAS ports, circle- or diamond-icon) on the second I/O module of the first VTrak.
Use a SFF-8088 4X to 4X external SAS cable (supplied with another VTrak).
3. Connect the remaining port on the first I/O module of the first VTrak to the first I/O module of the next VTrak.
Be sure to connect circle icon to diamond icon or vice versa.
4. Connect the remaining port on the second I/O module of the first VTrak to the second I/O module of the next VTrak.
Be sure to connect circle icon to diamond icon or vice versa.
Use SFF-8088 to SFF-8088 SAS cables to connect the VTraks.
5. Connect the remaining VTraks in the same manner.
You can cascade up to four VTraks in this manner. You can mix J610s and J310s units in the same cascade.
25
Page 30
VTrak J610s, J310s Product Manual
Figure 18. An example of a redundant DAS connection between two Host PCs and four cascaded VTrak J310s units. The J610s is similar
SAS HBA Cards
SFF-8088 external 4X to 4X SAS cables
PC
CN2
SFF-8088 to SFF-8088 SAS cable
CN1
CN2
CN2
CN1
O
I
115200
8 N 1
O
I
VTrak J310s
115200 8 N 1
CN2
O
I
115200
8 N 1
O
I
VTrak J310s
115200 8 N 1
CN1
O
I
115200
8 N 1
O
I
VTrak J310s
115200 8 N 1
CN1
O
I
115200
8 N 1
O
I
VTrak J310s
115200 8 N 1
Cascade Configuration 1 Cascade Configuration 2
PC
26
Page 31
Chapter 2: Installation

Setting Up Serial Cable Connections

Serial communication enables the Command Line Interface (CLI) on your PC to monitor to control the VTrak. The VTrak package includes one RJ11-to-DB9 serial data cable for each I/O module.
Figure 19. A serial connector is located on the I/O module. The J310s is shown. The J610s is similar
RJ11 Serial Connector
115200
8 N 1
O
I
115200 8 N 1
O
I
115200 8 N 1
To set up a serial cable connection:
1. Attach the RJ11 end of the serial data cable to the RJ11 serial connector on one of the I/O modules.
2. Attach the DB9 end of the serial data cable to a serial port on the Host PC or Server.
If your PC has two DB9 COM ports, and your VTrak has two I/O modules, you can connect a second serial data cable to the I/O module on the right.
See “Setting Up Data Cable Connections” on page 20 for an explanation of which I/O module is the default primary. To verify which I/O module is the default primary, see “Enclosure Command” on page 36.
27
Page 32
VTrak J610s, J310s Product Manual

Connecting the Power

Plug the power cords and switch on both power supplies. When the power is switched on, the LEDs on the front of the VTrak will light up.
Figure 20.VTrak J310s front panel LED display. The J610s is similar
Power
FRU Status
Not Used
I/O module-1 activity
I/O module-2 activity
Heartbeat
When boot-up is finished and the VTrak is functioning normally:
The heartbeat LED blinks green once every 3 seconds if one I/O module is installed, or twice every 3 seconds if two I/O modules are installed.
Power and FRU LEDs display green continuously.
I/O module LEDs flash green if there is activity on that connection.
There are two LEDs on each Drive Carrier. They report the presence of power and a disk drive, and the current condition of the drive.
Figure 21.Drive carrier LEDs
Disk Status
Power/Activity
Within one minute, the Power/Activity should display Green.
If there is no disk drive in the carrier, the Disk Status LED and the Power/Activity LED will remain dark.
28
Page 33
Chapter 2: Installation

Setting Up the CLI Connection

The VTrak has a Command Line Interface (CLI) to manage all of its functions, including customization. Access the CLI via your PC’s terminal VT100 or ANSI emulation program, such as Microsoft HyperTerminal.
With the VTrak running and the RJ11-to-DB9 serial data cable connected to the primary I/O module:
1. Change your terminal emulation program settings to agree with the following:
Bits per second: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: none
2. Start your PC’s terminal emulation program.
3. Press Enter once to launch the CLI.
The cli> prompt on your screen indicates that you have a connection and the CLI is ready to accept commands.
See “CLI Command Set” on page 35.
29
Page 34
VTrak J610s, J310s Product Manual
30
Page 35

Chapter 3: Management

Front Status Indicators (below)
Drive Status Indicators (page 24)
I/O Module Status Indicators (page 25)
CLI Command Set (page 26)

Front Status Indicators

Even though the Command Line Interface (CLI) offers comprehensive monitoring of VTrak, the LED indicators on the VTrak J610s or J310s unit provide important status information.
When the power is switched on, the LEDs on the front of the VTrak will light up.
Figure 1. VTrak J310s front panel LED display. The J610s is similar
Power
FRU Status
Not Used
I/O module-1 activity
I/O module-2 activity
Heartbeat
When boot-up is finished and the VTrak is functioning normally:
The heartbeat LED blinks green once every 3 seconds if one I/O module is installed, or twice every 3 seconds if two I/O modules are installed.
Power and FRU LEDs display green continuously.
I/O module LEDs flash green if there is activity on that connection.
31
Page 36
VTrak J610s, J310s Product Manual
LEDs
Dark
Power System Off Normal
Steady
Green
State
Flashing
Green
Amber Red
FRU* System Off Normal
I/O Module 1 or 2
Heartbeat System Off Normal**
* Field Replacement Unit: Cooling Unit (CU) or Power Supply Unit (PSU)
** Blinks intermittently.
No Activity Activity
1 CU and/or 1 PSU failed
2 CU and/or 2 PSU failed

Drive Status Indicators

After a few moments the Power/Activity should display Green.
If there is no disk drive in the carrier, the Disk Status LED and the Power/Activity LED will remain dark.
Figure 2. VTrak disk carrier LEDs
Disk Status
Power/Activity
The VTrak spins up the disk drives sequentially in order to equalize power draw during start-up. After a few moments the Power/Activity and Disk Status LEDs should display green.
If you have SATA disk drives installed without an AAMUX adapter (see page 16), the Power/Activity LED behavior depends on the specific disk drive.
The Disk Status LED behavior depends on your HBA or RAID controller. See the table below.
32
Page 37
Chapter 3: Management
LEDs
State
Dark Steady Green Flashing Green
Power/Activity* No Drive Drive Present Activity
Status HBA/RAID controller determines the LED behavior**
* Refers to SAS drives or SATA drives with an AAMUX adapter.
For SATA drives without an AAMUX adapter, LED behavior depends on the specific disk drive.
** Refer to the user documentation for your HBA or RAID controller for this
information.

I/O Module Status Indicators

The VTrak J610s or J310s I/O module has LEDs that indicate activity on each of its SAS ports.
Figure 3. The I/O modules have two SAS ports
115200
8 N 1
Diamond-icon port (CN2) LED
Circle-icon port (CN1) LED
I/O Module Status LED
The I/O module status LED shows red at startup. Within 2 or 3 seconds, it turns green to indicate that the I/O module is ready.
State
LEDs
Dark
Connectors Link Down Link Up Activity
I/O Module Status
* Turns green 2 to 3 seconds after subsystem startup.
Off Ready Starting up*
Steady
Green
33
Flashing
Green
Red
Page 38
VTrak J610s, J310s Product Manual
Figure 4. VTrak J610s power supply and fan LEDs
Fan LEDPower Supply LED
The battery LED on the cooling unit has no function on the VTrak J610s and J310s models.
Figure 5. VTrak J310s power supply and fan LEDs
Power Supply LED Fan LED
O
I
Under normal conditions, the power supply and fan LEDs should display green.
LEDs
State
Dark Green Red
Power supply Not detected OK Failed
Fan Not detected OK Failed
To check a component’s installation, follow the same procedure as replacing the component, except that you reinstall the original component rather than a new one. In most cases, this action fixes a bad connection and allows VTrak to detect the component. If this action does not correct the problem, replace the unit.
34
Page 39
Chapter 3: Management

CLI Command Set

The CLI uses the following set of commands:
cable – Specifies the length of cable for optimal signal quality.
enclosure – Displays full information on the VTrak enclosure and all its
components, expander addresses, and SAS addresses.
help – Use alone to see the list of commands. Use with a command to see a list of options. Examples: enclosure -help or enclosure -h.
link – Displays the current status of the PHYs (links) and the error counter.
route – Displays addresses of components through a downstream (expansion)
connection.
uptime – Displays the number of days, hours, minutes and seconds since the firmware was loaded (since the VTrak was started or restarted).
vpdr – Displays vital product data on field replaceable units.
? – Use alone to see the list of commands. Use with a command to see a list of options. Example: enclosure -?
Note
Command options are case-sensitive. Disable the Caps Lock on your keyboard.

Cable Command

The Cable command displays the current cable length settings for the two Host ports and the Expansion port. The I/O module supports cables from 1 to 8 meters in length.
To view current settings:
cli>cable
The system returns:
CN#1 Cable Length = 1 meter CN#2 Cable Length = 1 meter
CN#1 and CN#2 are the external SAS connectors on the I/O module. CN#1 is labeled with a circle icon. CN#2 is labeled with a diamond icon. See Figure 3.
To set Expansion connector CN2 for a 3-meter cable:
cli> cable -a mod -s “cn2=3”
To verify the setting change:
cli>cable
35
Page 40
VTrak J610s, J310s Product Manual
The system returns:
CN#1 Cable Length = 1 meter CN#2 Cable Length = 3 meter
Note the cable length change for CN2.

Enclosure Command

The Enclosure command:
Displays information about the J610s or J310s enclosure (below)
Enables you to make enclosure settings (page 38)
Information List
The Enclosure command displays information about the J610s or J310s enclosure, including:
Time since power-up
Enclosure type
I/O module information
PSU (power supply) status and fan speeds
Blower status and fan speeds
The CLI reports information for the I/O module to which it is connected and for the rest of the components in the J310s enclosure.
Under SAS specifications, both I/O modules are active at the same time. For management purposes, the default primary I/O module role is Primary. If a second I/O module is present, its role is Secondary. See the arrow below for I/O Module Role in the display. Also see “Setting Up Data Cable Connections” on page 20.
In a J610s or J310s unit with two I/O modules, if the primary I/O module fails or is removed, the remaining I/O module becomes the default primary I/O module and assumes the Primary role. If the other I/O module is repaired or replaced, it becomes the secondary I/O module and assumes the Secondary role.
Temperature sensor readings
Temperature threshold settings
Voltage sensor readings
Expander SAS addresses
Attached SAS addresses
Viewing Information
To view enclosure information:
cli>enclosure
36
Page 41
Chapter 3: Management
The system returns:
-------------------------------------------------------------------------------------
Time Since Power Up: 1 day 9 hours 46 minutes 36 seconds Enclosure: SAS JBOD [2U-12Bay or 3U-16 Bay] I/O Module ID: 1 Max Num Of I/O Modules: 2
FwVersion: 1.07.0000.00 I/O Module Role: Primary MaxNumOfHDSlots: [12 or 16] MaxNumOfPSUs: 2 MaxNumOfFans: 4 MaxNumOfBlowers: 2 MaxNumOfTempSensors: 8 MaxNumOfVoltageSensors: 5
=========================================== PSU Status Fan1Speed Fan2Speed =========================================== 1 Operational 14735 rpm 15037 rpm 2 Operational 15340 rpm 14361 rpm
=========================================== Blower Status Speed =========================================== 1 Operational 4017 rpm 2 Operational 4066 rpm
=========================================== ID Location Temp Reading ID Location Temp Reading ===========================================
1. Backplane 27C/80F 2. Backplane 28C/82F
3. Backplane 26C/78F 4. Backplane 26C/78F
5. I/O Module1 35C/95F 6. I/O Module1 26C/78F
7. I/O Module2 33C/91F 8. I/O Module2 38C/100F
Thermal Management: Enabled Allows to shut down the system when critical temperature is reached: Yes Current minimum fan speed setting: medium low Enclosure Temp Threshold: 61C/141F (critical) 51C/123F (warning) Controller Temp Threshold: 71C/159F (critical) 61C/141F (warning)
=========================================== VoltageSensor Voltage ===========================================
13.3V
25.0V
35.0V 4 12.0V
51.1V
37
Page 42
VTrak J610s, J310s Product Manual
Expander SAS Address: SAS Base Addr:50 00 15 5D 21 AB 02 00 SSP SAS Addr: 50 00 15 5D 21 AB 02 3E SMP SAS Addr: 50 00 15 5D 21 AB 02 3F
Attached SAS Address: D01 SAS Addr: 50 00 15 E0 11 4E 5E B2 D02 SAS Addr: 50 00 15 E0 11 4E 80 C2 D03 SAS Addr: 50 00 15 E0 11 4C 22 02 D04 SAS Addr: 50 00 15 E0 11 4D E2 22 D05 SAS Addr: 50 00 15 E0 11 4D 8F B2 D06 SAS Addr: 50 00 15 E0 11 4D D0 62 D07 SAS Addr: 50 00 15 E0 11 4D DE E2 D08 SAS Addr: 50 00 15 E0 11 4D 8E F2 D09 SAS Addr: 50 00 15 E0 11 4C 97 62 D10 SAS Addr: 50 00 15 E0 11 4C 36 62 D11 SAS Addr: 50 00 00 E0 11 4F 18 E2 D12 SAS Addr: 50 00 00 E0 11 4F 18 D2 D13 SAS Addr: 50 00 00 E0 11 4D 8E 52 D14 SAS Addr: 50 00 00 E0 11 4D E2 22 D15 SAS Addr: 50 00 00 E0 11 4E 49 C2 D16 SAS Addr: 50 00 00 E0 11 4D DC F2 CN1 SAS Addr: No Device Attached CN2 SAS Addr: 50 00 15 5F FF C0 22 3F
SAS addresses with a “D” represent physical drives. J310s units display only D01 through D12. J610s units display D01 through D16.
Settings List
The Enclosure command enables you to make settings for the enclosure. The J610s is shown. The J310s is similar.
Enclosure Warning Temperature – 51° to 61°C (123° to 141°F), measured at the backplane. Fan speed increases until temperature falls below the threshold.
Enclosure Critical Temperature – Exceeds 61°C (141°F). System shutdown after 30 seconds.
Controller Warning Temperature – 61° to 71°C (141° to 160°F), measured inside the I/O module. Fan speed increases until temperature falls below the threshold.
Controller Critical Temperature – Exceeds 71°C (160°F). System shutdown after 30 seconds.
Thermal Management – Monitors enclosure temperature, adjusts fan speeds, displays red LED on cooling unit when a fan fails
38
Page 43
Chapter 3: Management
Automatic Shutdown – Shuts down the VTrak 30 seconds after the enclosure or controller reaches critical temperature.
Minimum Fan Speed – Specifies the minimum fan speed when the VTrak reaches enclosure or controller warning temperature.
Making Settings
To set the enclosure critical temperature to 61°C (141°F):
cli>enclosure -a mod -s “enc_critical=61”
To enable Thermal Management:
cli>enclosure -a mod -s “thermalmanager=1”
For this command, a 1 enables and a 0 disables.
To enable Automatic Shutdown:
cli>enclosure -a mod -s “allowshutdown=1”
For this command, a 1 enables and a 0 disables.
To set the minimum fan speed to medium high:
cli>enclosure -a mod -s “minfanspeed=3”
For this command:
1 means low
2 means medium-low
3 means medium-high
4 means high
The actual speed depends on the fan manufacturer.
To display a complete list of Enclosure commands:
cli>enclosure -h

Help Command

The VTrak CLI uses the standard Unix online help system.
To access general help:
cli>help
39
Page 44
VTrak J610s, J310s Product Manual
To access help with a specific function:
cli>help cable
cli>cable -help
cli>cable -h
Choose any command from the list under “CLI Command Set” on page 35.

Link Command

The Link command displays information about J610s and J310s links, including:
•Link Status
•Link Counter
Viewing Link Status
To view link status:
cli>link
The system returns:
Link Status:
Port Type Rate Init Dev Link PRdy P 0 D01 SAS 3.0G OK End ---- Rdy P 1 D02 SAS 3.0G OK End ---- Rdy P 2 D03 SAS 3.0G OK End ---- Rdy P 3 D04 SAS 3.0G OK End ---- Rdy P 4 D05 SAS 3.0G OK End ---- Rdy P 5 D06 SAS 3.0G OK End ---- Rdy P 6 D07 SAS 3.0G OK End ---- Rdy P 7 D08 SAS 3.0G OK End ---- Rdy P 8 D09 SAS 3.0G OK End ---- Rdy P 9 D10 SAS 3.0G OK End ---- Rdy P10 D11 SAS 3.0G OK End ---- Rdy P11 D12 SAS 3.0G OK End ---- Rdy P12 D13 SAS 3.0G OK End ---- Rdy P13 D14 SAS 3.0G OK End ---- Rdy P14 D15 SAS 3.0G OK End ---- Rdy P15 D16 SAS 3.0G OK End ---- Rdy P16 CN1 ---- ---- ---- ---- ---- ---­P17 CN1 ---- ---- ---- ---- ---- ---­P18 CN1 ---- ---- ---- ---- ---- ---­P19 CN1 ---- ---- ---- ---- ---- ---­P20 CN2 SAS 3.0G OK End ---- Rdy P21 CN2 SAS 3.0G OK End ---- Rdy
40
Page 45
Chapter 3: Management
P22 CN2 SAS 3.0G OK End ---- Rdy P23 CN2 SAS 3.0G OK End ---- Rdy
Port:Port Id Type:SAS Rate:Rate 3G Init:Init Passed Dev:Device Type Link:Link Connected PRdy:Phy Ready
The following items are reported in the table above:
Link number – The links are PHYs, numbered P0 through P23
Port number – D01 through D16 represent drive slots. Each slot has one PHY. D13 through D16 are empty on J310s units. See “Drive Numbering” on page 19.
CN1 and CN2 represent the external SAS port connectors. Each port has four PHYs. CN1 is labeled with a circle icon. CN2 is labeled with a diamond icon. See Figure 3 on page 33
Drive Type – SAS
Data Rate – 3.0 Gb/s
Device Type – End means an end device. Exp means an expansion device
Link Connection – Normally, ---- is displayed. If there is a connection at the moment the link command runs, it will display CONN
Phy Ready Status – If the port is ready, it will display Rdy
Link Counter:
InDW DsEr DwLo PhRe CoVi PhCh P 0 ---------- ---------- ---------- ---------- ---------- 0x11 P 1 ---------- ---------- ---------- ---------- ---------- 0x61 P 2 ---------- ---------- ---------- ---------- ---------- 0x0D P 3 ---------- ---------- ---------- ---------- ---------- 0x0D P 4 ---------- ---------- ---------- ---------- ---------- 0x01 P 5 ---------- ---------- ---------- ---------- ---------- 0x61 P 6 ---------- ---------- ---------- ---------- ---------- 0x11 P 7 ---------- ---------- ---------- ---------- ---------- 0x0D P 8 ---------- ---------- ---------- ---------- ---------- 0x0D P 9 ---------- ---------- ---------- ---------- ---------- 0x01 P10 ---------- ---------- ---------- ---------- ---------- 0x0D P11 ---------- ---------- ---------- ---------- ---------- 0x0D P12 ---------- ---------- ---------- ---------- ---------- 0x01 P13 ---------- ---------- ---------- ---------- ---------- 0x5D P14 ---------- ---------- ---------- ---------- ---------- 0x0D P15 ---------- ---------- ---------- ---------- ---------- 0x09 P16 ---------- ---------- ---------- ---------- ---------- ---­P17 ---------- ---------- ---------- ---------- ---------- ---­P18 ---------- ---------- ---------- ---------- ---------- ---­P19 ---------- ---------- ---------- ---------- ---------- ----
41
Page 46
VTrak J610s, J310s Product Manual
P20 ---------- ---------- ---------- ---------- ---------- 0x8F P21 ---------- ---------- ---------- ---------- ---------- 0x8F P22 ---------- ---------- ---------- ---------- ---------- 0x8F P23 ---------- ---------- ---------- ---------- ---------- 0x8F
InDW:Invalid Dword Count DsEr:Disparity Err Count DwLo:Dword Sync Loss Count PhRe:Phy Reset Problem Count CoVi:Code Violations Cnt PhCh:Phy Change Count
The following items are reported in the table above. All counts are hexadecimal:
Link number – Links are PHYs, numbered P0 through P23.
The Link Status list matches Link number to Port number, where you can identify the specific disk drive or external SAS port reported in the Link Counter. See page 40.
Invalid D-word Count
Disparity Error Count
PHY Reset Problem Count
Code Violation Count
PHY Change Count
If the count is zero, the counter shows dashes (----------). The fact that errors occur does not necessarily indicate a problem or that the J610s or J310s unit is malfunctioning.
An individual error count that increments regularly indicates a possible problem and requires further investigation.
Clearing the Error Count
To clear the link error count:
cli>link -a clear

Route Command

To view the SAS addresses of the devices in your domain:
cli>route
The system returns:
Routing Table Mapping: Entry# SAS Address CnID
--------------------------------------------------­0159 500000E0114D8FB2 CN2 0163 500000E0114C2252 CN2 0202 500000E0120B3562 CN2
42
Page 47
Chapter 3: Management
0238 500000E01212F582 CN2 0287 500000E0120B26B2 CN2
0365 5000155FFFC0223E CN2 0462 500000E0114F18F2 CN2 0468 500000E01205B472 CN2 0542 500000E01122C5B2 CN2 0624 500000E0114E4A32 CN2
0639 500000E0114D8E32 CN2 0700 500000E0120B2A62 CN2 0721 500000E0114DE7A2 CN2 0751 500000E0114E5EA2 CN2 0764 500000E0120B28F2 CN2
0765 500000E0114C2342 CN2 0977 500000E0120A2472 CN2 1023 5000155FFFC02408 CN2
The route command displays SAS addresses that are attached to the SAS ports of the J610s or J310s unit. Three items are reported:
Entry# – Arbitrary numbers, listed in sequence
SAS Address – Of the disk drive or other component
CnID – External SAS port connector number 1 or 2
The device in this example is connected to a J610s unit through connector CN2. See page 21 for a diagram of connectors on the I/O module.
Route Troubleshooting
If your system returns:
No SAS Routing Entry Exists
...it indicates that no downstream devices are found.

Uptime Command

The uptime command informs you of the elapsed period of time since the J610s or J310s unit was powered on.
To display uptime:
cli>uptime
The system returns:
System has been running 1 day 9 hours 46 minutes 36 seconds
43
Page 48
VTrak J610s, J310s Product Manual

VPDR Command

The vpdr command displays vital product data on the major components of the VTrak. There are six components that report vital product information.
1 – Controller (I/O module)
2 – Power Supply 1
3 – Cooling Unit 1
4 – Power Supply 2
5 – Cooling Unit 2
6 – Backplane
Specify the component by its number. For I/O modules, the system reports for the module to which you made your CLI connection. See “Setting Up the CLI Connection” on page 29
For example, to display vital product data for the I/O module:
cli>vpdr -i 1
The system returns:
Board ID :0 OEM Name :PROMISE OEM Model :3U-SAS-16-D BP Mfg Part :IOC-J610s-01 Mfg SN :B17D07138400004 Mfg Rev :A1R1.0 Mfg Date :2007:02:15 WWN :20 00 00 01 55 FF FC 0D

? Command

The VTrak CLI uses the standard Unix online help system.
For the command usage of a particular function:
cli>cable -?
cli>? cable
Choose any command from the list under “CLI Command Set” on page 35.
44
Page 49

Chapter 4: Support

Frequently Asked Questions (below)
Contacting Technical Support (page 46)
Limited Warranty (page 49)
Returning product for repair (page 50)

Frequently Asked Questions

What kind of disk drives can I use with VTrak?
The J610s and J310s support 3.5-inch Serial Attached SCSI (SAS) disk drives and SATA II disk drives. If your VTrak has dual I/O modules, you must install an AAMUX adapter on each of your SATAII drives.
How can I tell when the VTrak has fully booted?
When the J610s or J310s unit is fully booted up, the Power and FRU LEDs will light up green. The heartbeat LED blinks green once every 3 seconds if one I/O module is installed, or twice every 3 seconds if two I/O modules are installed.
How can I tell my CLI connection is to the primary default I/O module?
After you establish the CLI connection, type Enclosure and press Enter. Look at the top of the display for an item called I/O Module Role. If the Role is Primary, you are connected to the default primary I/O module. If the Role is Secondary, you are connected to the default secondary.
What happens if a disk drive fails?
Depending on the nature of the failure, the failed drive the drive might not appear in the CLI—or the failed drive might appear with some errors—when you run the enclosure command (see page 36) or the link command (see page 40).
Can I hot-swap a failed drive with a new one?
Yes. Disk drives are hot-swappable on the J610s and J310s units.
Can the VTrak run using just one power supply?
Yes, it is possible to run J610s and J310s unit on a single power supply. The units will continue running if one of the power supply fails. However, leaving one power supply off reduces air flow through the enclosure and can contribute to overheating. Always switch on both power supplies.
45
Page 50
VTrak J610s, J310s Product Manual

Contacting Technical Support

Promise Technical Support provides several support options for Promise users to access information and updates. We encourage you to use one of our electronic services, which provide product information updates for the most efficient service and support.
Important
Promise offers 24x7 live technical support (in English only) for registered owners of VTrak products. To register, point your browser to:
http://www.promise.com/support/warranty/ warranty_eng_pdchoose.asp
If you decide to contact us, please have the following information available:
Product model and serial number
BIOS, firmware and driver version numbers
A description of the problem / situation
System configuration information, including: motherboard and CPU type, hard drive model(s), SAS/SATA/ATA/ATAPI drives & devices, and other controllers.

Technical Support Services

Promise Online™ Web Site http://www.promise.com/support
(technical documents, drivers, utilities, etc.)

United States

E-mail Support e-Support On-Line
Fax Support (408) 228-1097 Attn: Technical Support
Phone Support (408) 228-1400 option 4
If you wish to write us for support:
Promise Technology, Inc. 580 Cottonwood Drive Milpitas, CA 95035, USA
46
Page 51

The Netherlands

E-mail Support e-Support On-Line
Fax Support +31 (0) 40 256 9463 Attn: Technical Support
Phone Support +31 (0) 40 235 2600
Chapter 4: Support
If you wish to write us for support:
Promise Technology Europe B.V. Science Park Eindhoven 5542 5692 EL Son, The Netherlands

Germany

E-mail Support e-Support On-Line
Fax Technical Support +49 (0) 2 31 56 76 48 - 29
Attn: Technical Support
Phone Technical Support +49 (0) 2 31 56 76 48 - 10
If you wish to write us for support:
Promise Technology Germany Europaplatz 9 44269 Dortmund, Germany

Italy

E-mail Support e-Support On-Line
Fax Support 0039 06 367 12400 Attn: Technical Support
Phone Support 0039 06 367 12626
If you wish to write us for support:
Promise Technology Italy Piazza del Popolo 18 00187 Roma, Italia
47
Page 52
VTrak J610s, J310s Product Manual

Taiwan

E-mail Support e-Support On-Line
Fax Support +886 3 578 2390 Attn: Technical Support
Phone Support +886 3 578 2395 (ext. 8811)
If you wish to write us for support:
Promise Technology, Inc. 2F, No. 30, Industry E. Rd. IX Science-based Industrial Park Hsin-Chu 30075, Taiwan, (R.O.C.)

China

E-mail Support e-Support On-Line
Fax Support
Phone Support +86-10-8857-8085/8095
If you wish to write us for support:
+86-10-8857-8015
Promise Technology China Room 1205, Tower C Webok Time Center, No.17 South Zhong Guan Cun Street Hai Dian District, Beijing 100081, China
Attn: Technical Support
48
Page 53
Chapter 4: Support

Limited Warranty

Promise Technology, Inc. (“Promise”) warrants that for three (3) years from the time of the delivery of the product to the original end user:
a) the product will conform to Promise’s specifications;
b) the product will be free from defects in material and workmanship under
normal use and service.
This warranty:
a) applies only to products which are new and in cartons on the date of
purchase;
b) is not transferable;
c) is valid only when accompanied by a copy of the original purchase
invoice.
d) Is not valid on spare parts, fans, and power supplies
This warranty shall not apply to defects resulting from:
a) improper or inadequate maintenance, or unauthorized modification(s),
performed by the end user;
b) operation outside the environmental specifications for the product;
c) accident, misuse, negligence, misapplication, abuse, natural or
personal disaster, or maintenance by anyone other than a Promise or a Promise-authorized service center.

Disclaimer of other warranties

This warranty covers only parts and labor, and excludes coverage on software items as expressly set above.
Except as expressly set forth above, Promise DISCLAIMS any warranties, expressed or implied, by statute or otherwise, regarding the product, including, without limitation, any warranties for fitness for any purpose, quality, merchantability, non-infringement, or otherwise. Promise makes no warranty or representation concerning the suitability of any product for use with any other item. You assume full responsibility for selecting products and for ensuring that the products selected are compatible and appropriate for use with other goods with which they will be used.
Promise DOES NOT WARRANT that any product is free from errors or that it will interface without problems with your computer system. It is your responsibility to back up or otherwise save important data before installing any product and continue to back up your important data regularly.
49
Page 54
VTrak J610s, J310s Product Manual
No other document, statement or representation may be relied on to vary the terms of this limited warranty.
Promise’s sole responsibility with respect to any product is to do one of the following:
a) replace the product with a conforming unit of the same or superior
product;
b) repair the product.
Promise shall not be liable for the cost of procuring substitute goods, services, lost profits, unrealized savings, equipment damage, costs of recovering, reprogramming, or reproducing of programs or data stored in or used with the products, or for any other general, special, consequential, indirect, incidental, or punitive damages, whether in contract, tort, or otherwise, notwithstanding the failure of the essential purpose of the foregoing remedy and regardless of whether Promise has been advised of the possibility of such damages. Promise is not an insurer. If you desire insurance against such damage, you must obtain insurance from another party.
Some states do not allow the exclusion or limitation of incidental or consequential damages for consumer products, so the above limitation may not apply to you.
This warranty gives specific legal rights, and you may also have other rights that vary from state to state. This limited warranty is governed by the State of California.

Your Responsibilities

You are responsible for determining whether the product is appropriate for your use and will interface with your equipment without malfunction or damage. You are also responsible for backing up your data before installing any product and for regularly backing up your data after installing the product. Promise is not liable for any damage to equipment or data loss resulting from the use of any product.

Returning Product For Repair

If you suspect a product is not working properly, or if you have any questions about your product, contact our Technical Support Staff through one of our Technical Services, making sure to provide the following information:
Product model and serial number (required)
Return shipping address
Daytime phone number
Description of the problem
Copy of the original purchase invoice
50
Page 55
Chapter 4: Support
The technician will assist you in determining whether the product requires repair. If the product needs repair, the Technical Support Department will issue an RMA
(Return Merchandise Authorization) number.
Important
Obtain an RMA number from Technical Support before you return the product and write the RMA number on the label. The RMA number is essential for tracking your product and providing the proper service.
Return ONLY the specific product covered by the warranty (do not ship cables, manuals, diskettes, etc.), with a copy of your proof of purchase to:
USA and Canada: Promise Technology, Inc.
Customer Service Dept. Attn.: RMA # ______ 47654 Kato Road Fremont, CA 94538
Other Countries: Return the product to your dealer
or retailer.
Contact them for instructions before shipping the product.
You must follow the packaging guidelines for returning products:
Use the original shipping carton and packaging
Include a summary of the product’s problem(s)
Write an attention line on the box with the RMA number
Include a copy of proof of purchase
You are responsible for the cost of insurance and shipment of the product to Promise. Note that damage incurred due to improper transport or packaging is not covered under the Limited Warranty.
When repairing returned product(s), Promise may replace defective parts with new or reconditioned parts, or replace the entire unit with a new or reconditioned unit. In the event of a replacement, the replacement unit will be under warranty for the remainder of the original warranty term from purchase date, or 30 days, whichever is longer.
Promise will pay for standard return shipping charges only. You will be required to pay for any additional shipping options (such as express shipping).
51
Page 56
VTrak J610s, J310s Product Manual
52
Page 57

Appendix A: Second I/O Module

The VTrak J610s and J310s units ship with one or two I/O modules. If your VTrak came with only one I/O module, you can upgrade by installing a second I/O module. The following instructions describe how to install a second I/O module.
To install a second I/O module into a VTrak J610s or J310s unit:
1. Power down the VTrak.
2. Press the release button on the dummy I/O module, pull the handle down and remove the dummy I/O module from the enclosure.
3. Slide the new I/O module into the slot.
4. Gently push the new I/O module all the way into the slot until the handle locks.
5. Connect your data cables to the new I/O module.
See page 20 for more information.
6. Optional. Connect your serial cable to the second I/O module.
See page 27 for more information.
7. Power up the VTrak.
To verify proper installation and function, run the enclosure command in the CLI. Because the new I/O module is installed in the right slot, it will automatically take the Standby role in the CLI screen. See page 36 for more information.
53
Page 58
VTrak J610s, J310s Product Manual
54
Page 59

Index

Symbols
? command 44
A
AAMUX adapter 16, 18, 32 About This Manual 1 Attached SAS addresses 36 automatic shutdown setting 39
B
blower status 36
C
cable
command RJ11-to-DB9 9, 27, 29
SAS SFF-8088 9, 22, 23, 25 CE statement 7 Certifications 7 circle-icon port 21, 23, 25 CN1, CN2 21 Command
?
44
cable 35
CLI 35
enclosure 36, 45
help 39
link 40, 45
route 42
set 35
uptime 43
vpdr 44 component data 44 Connection
CLI
data cables 20
power 28
serial 27
35
29
cooling unit LED 34
D
DAS
basic
22
cascade 23 redundant 25 supported 20
Data cable connections 20
Basic DAS 22 Cascading DAS 23
Redundant DAS 25 diamond-icon port 21, 23, 25 Dimensions 7 disk drives
drive carriers
hot-swappable 45
install 16
numbering 19
supported 16, 45
18
E
enclosure command 36, 45 end device 22 Environmental 6 error counts 42 ESD Warning 9 expander SAS addresses 36
F
FCC statement 8 Features and Benefits 5 Frequently Asked Questions 45 FRU LED 28, 31
G
GOST-R statement 7
55
Page 60
VTrak J610s, J310s Product Manual
H
HBA card 21, 22, 23, 25 Heartbeat LED 28, 31 help command 39
I
I/O module 10, 27
add second module 53 default primary 20 dual 25 role 36, 45, 53 SAS ports 22, 23, 25
IRAM statement 8
L
LEDs
cooling unit disk drives 32 drive carrier 28 fan 34 front 31 front panel 28, 31 FRU 31 heartbeat 31 I/O module 33 power 31 power supply 34
link
command connection 41 number 41 status and counter 40
34
40, 45
M
mapping, routing table 42 MIC statement 8 minimum fan speed setting 39
O
Operating Systems, supported 6
P
PHY ready status 41 port
circle icon
CN1, CN2 21
diamond icon 21, 23, 25
number 41 Power
connection
LED 28, 31
requirements 6 power supply 10
LED 34
single 45
status 36 primary I/O module 20
21, 23, 25
28
R
rackmount
E310f/s
E610f/s 11 regulatory statements 7, 8 RJ11-to-DB9 cable 9, 27, 29 RMA number 51 role, I/O module 36, 45, 53 route command 42 routing table mapping 42 RS232 serial communication 27
13
S
SAS
address
end device 22
expander address 36
HBA card 21, 22, 23, 25 screws, counter-sink 16 Serial cable connections 27, 29
42
56
Page 61
Index
serial communication 27 setting
automatic shutdown minimum fan speed 39 temperature 38
thermal management 38 SFF-8088 cable 9, 22, 23, 25 Specifications 6 Status Indicators
disk drives
front 31
I/O module 33 status, PHY 41
32
39
T
Technical Support 46 temperature
sensors
settings 38 thermal management setting 38
36
U
Unpack the VTrak 9 uptime command 43
V
vital product data 44 voltage sensors 36 vpdr command 44 VTrak
rackmount E310f/s rackmount E610f/s 11 returning for repair 50 unpack 9 warranty 7
W
Warranty 49
13
57
Page 62
VTrak J610s, J310s Product Manual
58
Loading...