Prince Castle 625-A User Manual

0 (0)

Operation

Manual

Steamer

625-A

Product Identification

 

Temperature &

Celsius/Fahrenheit &

On/Off Rocker Switch

UP Arrow Button

DOWN Arrow Button Steamer

(left-side of unit)

Prince Castle

Logo Button

 

Logo Button

 

Spatula

 

External Meter Plug Inlet

 

 

 

(for calibration)

 

 

Control Panel

Product

LED Display

Start Button

 

Buttons

 

 

 

(1 thru 4)

 

 

LIMITED WARRANTY

This product (with the exception of the water tube, part no. 625-197S) is warranted to be free from defects in material and/or workmanship for a period of two (2) years from date of original installation, not to exceed 30 months from date of shipment from our factory. P.C. Boards and Heater Assemblies are warranted for three (3) years from date of installation, not to exceed 42 months from date of shipment. Any component which proves to be faulty in

material and/or workmanship will be replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer for parts or labor. This warranty covers on location service (i.e. trip charges and/or mileage). Travel mileage is limited to 100 miles (200 kilometers) round trip (one trip warranty) from an authorized service agency or its sub-service agency.

This warranty is subject to the following exceptions/conditions:

Use of any non-genuine Prince Castle parts voids this warranty.

All labor shall be performed during regular work hours. Overtime premium will be charged to the buyer.

Damage caused by carelessness, neglect, and/or abuse (e.g., dropping, tampering or altering parts, equipment damaged in shipment, by fire, flood or an act of God) is not covered under this warranty.

TABLE OF CONTENTS

Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Temperature Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

View Firmware Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Manual Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Programming Product Name & Water Cycle . . . . . . . . . . . . . . . . . . . . . . . .4

Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Cleaning - Daily . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Cleaning - Monthly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Exploded View and Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

SANITATION

355 East Kehoe Blvd. • Carol Stream, IL 60188

Phone: 630-462-8800 • Toll Free: 1-800-PCASTLE Fax: 630-462-1460 • www.princecastle.com

Steamer 625-502revA

Printed in USA 0910 © 2003

Steamer 625-A

Safety Information

WARNING

Indicates information important to the proper operation of the unit. Failure to observe may result in damage to the equipment and/or severe bodily injury or death.

CAUTION

Indicates information important to the operation of the unit. Failure to observe may result in damage to the equipment.

Important

Prince Castle reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.

Installation

Remove the unit from the carton and inspect for signs of damage. If

NOTE: When installing this unit, the ambient temperature at the

there is damage to the unit:

mounting site should not exceed 37.8°C (100°F) .

notify the carrier within 24 hours of delivery

CAUTION

save carton and packaging materials for inspection purposes

All electrical connections must be in accordance with local electrical

contact your local dealer, or if purchased directly, the Prince Castle

codes and any other applicable codes.

 

Sales Department at 800-722-7853 or 1-630-462-8800 to arrange for a

Plug the unit into an applicable electrical receptacle.

 

replacement unit.

WATER CONNECTION REQUIREMENTS

Connect the water line to the back of the unit.

 

If this is a new installation, accessory - 625-104 Regulatory Assembly Kit

CAUTION

is required. You may also need accessory part #625-103 Coil Hose Kit

Water connection must provide maximum water pressure of

Assembly. Always use area codes for determination.

20-30 psi (138-207 kPa).

 

Operation

A.Turn unit power On/Off switch to ON position. The display

1flashes PRINCE CASTLE for ten seconds.

B.After ten seconds the display will show PR.E-HEAT.

NOTE: The next-to-left most decimal point appears

indicating power is applied to the platen. Platen will heat to the setpoint temperature.

prince castle

 

pr.e-heat

 

 

 

 

 

Place the spatula fully into the unit and press the START button. 3 The display will start to count down the steam cycle.

A. When the unit reaches the setpoint temperature, display will

2

show the product name assigned to button 1.

 

 

B. If 1 is the desired product to be steamed, pull out the

 

spatula and place the product onto the spatula, cut side

 

down.

 

Or

 

press product buttons 2, 3 or 4, then place product on the

 

spatula, cut side down.

filet

When steam cycle is complete, the unit will sound a tone and 4 the display will flash REMOVE.

Pull out the spatula and remove the finished product.

8

remove

Steamer 625-502revA

2

Printed in USA 0910 © 2003

Prince Castle 625-A User Manual

Steamer 625-A

Temperature Adjustment

A.Press and hold the TEMPERATURE button. The display will

1show the current temperature setting for Celsius (C) or Fahrenheit (F).

B.While holding the TEMPERATURE button, press the C/F button to change the setting between Fahrenheit and Celsius.

C.Release the TEMPERATURE button to store the new value.

 

129 C

 

 

255 F

 

 

 

 

 

 

3

Platen temperature can be set between 129°-152°C (265°- 305°F).

Pre-set at factory to 140°C (285°F) .

 

 

A.Press the UP or DOWN Arrow buttons to scroll to the desired temperature.

B.Press the Steamer LOGO button to store the desired temperature and exit the SET TEMP mode.

NOTE: Pressing the PRODUCT 3 button at any time exits the Program mode without storing the change.

 

TEMP 275

TEMP 275

 

 

 

5

A. Press the UP or DOWN Arrow buttons until the temperature

readout matches the calibration reading.

B.Press the Steamer LOGO button to store the desired temperature and exit CAL TEMP mode.

NOTE: Pressing the Product 3 button at any time exits the Program mode without storing the change.

CAL 265

CAL 265

 

 

2

A. Press and hold the Steamer LOGO button first, then

press and hold TEMPERATURE button for approximately

6 seconds.

The display will show SET TEMP.

B. Press the Steamer LOGO button again to display the current set temperature.

set temp

 

255

 

 

 

 

 

 

 

 

 

The CAL TEMP mode is used to calibrate the platen temperature 4 with an external meter connected to the meter plug inlet on the

bottom right side of the unit. Add ± 5°C (± 10°F) . Repeat Step 2A

A.Press the UP and DOWN Arrow buttons to scroll to CAL TEMP.

B.Press the Steamer LOGO button again to display the current calibration temperature.

C.Press the PRODUCT 2 button to zero any previous calibration offset value. The display will now show the platen temperature without any calibration offset.

CAL TEMP

CAL 245

Factory Presets

Loading factory presets restores the unit to factory settings and voids all user programmed information.

A.During power up, press and hold both PRODUCT 1 and PRODUCT 4 buttons within 3 seconds. The display will flash PRESETS LOADED.

B.Release both buttons.

Default Factory Presets:

 

ON

OFF Cycles

All

1

3

2

presets loaded

View Firmware Version

Press and hold the Seamer LOGO button first, then press and hold the START button.

The display will show the current firmware version.

. VERS XX.XX

Manual Reset

A hi-limit thermostat will turn off electrical power to the platen and control circuits if the unit overheats.

Turn the unit off and allow to cool (approximately 10-15 minutes).

A manual reset is located on the back of the unit. Once the unit has cooled sufficiently, press the manual reset and restart the unit.

NOTE: If the unit continues to shut-off due to overheating, contact your authorized Prince Castle Service Agency.

Manual Reset

Steamer 625-502revA

3

Printed in USA 0910 © 2003

Steamer 625-A

Programming Product Name & Water Cycle

The Program button menus can be changed to any of the following menu items.

PROD1 thru PROD12 can be selected to program additional product names.

“– – – –” can be used when no product name selection is desired.

Filet

Large

PROD1

PROD2

PROD3

PROD4

PROD5

PROD6

PROD7

PROD8

PROD9

PROD10

PROD11

PROD12

– – – –

A.Press and hold the LOGO button and a PRODUCT button for

1approximately 6 seconds. The display will show the current assigned product for the button pressed.

NOTE: A decimal point will appear and flash on the right side of the display to indicate Programming mode.

FILET

2

B. Press the UP or DOWN Arrow button to scroll through the

product selections.

C. Press the Steamer LOGO button to store the new product name.

To enter custom product names, proceed to step 3.

NOTE: Pressing the Product 3 button at any time exits the Program mode without storing the change.

PROD 1

PROD 1

Press and hold the Prince Castle LOGO button first, then press 3 and hold the Steamer Logo button for 6 seconds.

The display will show the product name with the left-most character display or decimal point flashing.

NOTE: Must be in Programming mode.

PROD 1

A.Press the UP or DOWN Arrow buttons to change the 4 left-most character.

B.Press the Product 1 or Product 4 button to move the cursor to the next character.

C.Repeat steps A and B for each character.

D.Press the Steamer LOGO button to store the new product name.

NOTE: Pressing the Product 3 button at any time exits the Program mode without storing the change.

CROD 1

CHKN 1

5

The display now shows the product’s water valve ON time in

seconds.

ON 1.1

A.Press the UP or DOWN Arrow buttons to change the valve 6 ON time.

B.Press the Steamer LOGO button to store the new valve ON time.

NOTE: Pressing the Product 3 button at any time exits the Program mode without storing the change.

7

The display now shows the product’s water valve OFF time

in seconds.

OFF 2.5

ON 1.1

ON 1.1

Steamer 625-502revA

4

Printed in USA 0910 © 2003