MAP80 SERIES
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) – 80W CONTINUOUS OUTPUT POWER
MODEL
OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4010
+12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V
-12V Fixed 3A 3A 0.5% 2% 1% -11.5V to -12.5V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4020
+12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V
-12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V
-5V Fixed 3A 3A 0.5% 2% 1% -4.8V to -5.4V
NOTES: 1) Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 90 135 VAC
175 264
Input Frequency AC input. 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC
Hold-up Time Nominal AC input voltage (115VAC), full rated load. 20 mS
Input Current 90 VAC (80W load). 2.5 ARMS
110VAC (80W load). 2.8
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C. 45 APK
Operating Frequency Switching frequency of power supply (varies with load). 22 120 kHz
OUTPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full load, 115VAC. Varies with distribution of loads among outputs. 73 75 80 %
Minimum Loads MAP80-1012 0.42
MAP80-1024 0.21 Amps
MAP80-1005 and all multiple output models, main channel only. 1.00
Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart.
Output Power Continuous output power, all multiple output models. 80 Watts
Peak output power (60s maximum, 10% duty cycle), all multiple output models. 90 Watts
Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 %
Regulation Varies by output. Total regulation includes: line changes from 90-132 VAC See Model Selection Chart.
or 175-264, changes in load starting at 20% load and changing to 100% load.
Transient Response Recovery time, to within 1% of initial set point due to a 50-100% 500 µS
load change, 4% max. deviation. (Main output of multiple output units).
Turn-On Delay Time required for initial output voltage stabilization. 1 5 Sec
Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Provided on MAP80-1005 and the main output of multiple output units. 5.5 6.8
Protection MAP80-1012 17 23 V
MAP80-1024 32 37
Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Power Fail TTL compatible logic signal. Time before regulation dropout
Warning (Note 1) due to loss of input power at 110VAC. 4 mS
NOTES: 1) Power Fail Warning is not available on MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.