Model: LDS-120V
LED Dimming Stabilizer
LDS-120V CONNECTED AT DIMMER
LED FIXTURES
WALL DIMMER
SWITCH
LINE IN
NEUTRAL
LOAD
NEUTRAL
LDS-120V
LDS-120V CONNECTED AT FIXTURE END OF CIRCUIT
LED FIXTURES
WALL DIMMER
SWITCH
LINE IN
NEUTRAL
LOAD
NEUTRAL
LDS-120V
MULTIPLE LDS-120V CONNECTED
LED FIXTURES
WALL DIMMER SWITCH
LINE IN
NEUTRAL
LOAD
NEUTRAL
LDS-120V
LDS-120V CONNECTED IN SERIES - INCORRECT
LED FIXTURES
WALL DIMMER
SWITCH
LINE IN
NEUTRAL
LOAD
NEUTRAL
LDS-120V
Why Would I Need an LDS-120V?
This smart electronic load resistor is the best solution for
your LED fixtures and bulbs having issues turning off
completely and flickering at certain dim levels. We have
found that by installing a small device (LDS-120V) in
parallel with the LED load it frequently eliminates these
problems.
RATINGS
120VAC, 1.8W
LED Max Load if LDS installed in box behind dimmer
400W if (1) LDS installed in single-gang box
300W if (2) LDS installed in single-gang box
400W if (2) LDS installed in double-gang box
WIRING DIAGRAMS
INSTALLATION
Note: Installation must be carried out by a qualified
electrician only. The circuit breaker must be turned off
during installation. Installation must be carried out in
accordance with all applicable codes and requirements,
including, but not limited to, the National Electrical Code
(NEC).
1. Turn off the power at the main breaker panel.
2. Locate the load (red) and neutral (white) wire. Install
behind dimmer location or at LED fixture location.
3. Install the LDS-120V between the two wires (Figure 1).
The LDS-120V may be wired in either direction of the
leads but it has to be PARALLEL with the LED light.
4. Use appropriate wire nuts to make a solid electrical
connection. Secure the wires and placement of LDSĀ120V.
5. The LDS-120V has high resistance, dissipates 1.8W
and is designed to be directly wired across 120VAC.
Powerline Control Systems
19201 Parthenia St. Suite J,
Northridge, CA 91324
NOTE:
Please note the load resistor is installed in PARALLEL with the LED.
This means the load resistor is wired between the switch load wire
(RED) and neutral wire (WHITE). If the load resistor is incorrectly
installed in SERIES with the load, the LED will stay off. This will not
hurt the load resistor or the switch or the LED, but the LED will
never go on.
P: 818.701.9831 F: 818.701.1506
www.pcslighting.com
pcssales@pcslighting.com