904461 - 09-04-02.qxd 9/23/02 8:20 AM Page 1
|
ESPAÑOL: PÁGINA 13 |
|
|
FRANÇAISE : PAGE 25 |
|
Instruction |
ROOFING COIL |
|
manual |
||
NAILER |
||
|
To learn more about Porter-Cable visit our website at:
http://www.porter-cable.com
Copyright © 2002 Porter-Cable Corporation
MODEL RN175
IMPORTANT
Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations.
The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No. _______________________________________
Part No. 904461 - 09-04-02
904461 - 09-04-02.qxd 9/23/02 8:20 AM Page 2
PORTER CABLE
Porter-Cable Corporation
4825 Highway 45 North
Jackson, TN 38305
GB ENGLISH EC-DECLARATION OF
CONFORMITY
We declare under our sole responsibility that this product is in conformity with the regulations EN292-2: section 3 of 1992 EN292-1: section 5 of 1992 EN1050: 1993
EN792 13: 2000
E ESPANOL DECLARACION DE
CONFORMIDAD ”CE”
Declaramos bajo nuestra sola responsabilidad que est e producto está en conformidad con las regulaciones EN292-2: section 3 of 1992 EN292-1: section 5 of 1992
EN1050: 1993
EN792 13: 2000
F FRANÇAISE
DÉCLARATION DE CONFORMITÉ CE
Nous declarons sous notre propre responsabilite que ce produit est conforme aux reglementations
EN292-2: section 3 of 1992 EN292-1: section 5 of 1992 EN1050: 1993
EN792 13: 2000
Matthew G. Popik
Vice President of Engineering
Date of Manufacture:___________________________
Fecha de fabricación:, Date de fabrication:
Serial No:______________________________________
Número de serie:, Nombre d'ordre
2
904461 - 09-04-02.qxd 9/23/02 8:21 AM Page 3
GENERAL SAFETY RULES
DANGER: When using pneumatic tools, basic safety precautions should always be followed to reduce the risk of personal injury, including the following:
READ AND FOLLOW ALL INSTRUCTIONS.
There are certain applications for which this tool was designed. Porter-Cable strongly recommends that this tool NOT be modified and/or used for any application other than for which it was designed. If you have any questions relative to its application DO NOT use the tool until you have written PorterCable and we have advised you.
1. Read and understand tool labels and manual. Failure to follow warnings could result in DEATH or SERIOUS INJURY. Fig. 1.
2. Operator and others in work area MUST wear safety glasses with side shields.
These safety glasses must conform to ANSI Z87.1 requirements (approved glasses have “Z87” printed or stamped on them). Fig. 2.
3.Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing.
4.Choice of triggering method is important. Check manual for selectable triggering instructions. See Using the Tool with Selectable Triggering Options section of this manual.
5.Never point tool at yourself or others in work area. Fig. 3
6.Never use oxygen or other bottled gasses. Explosion may occur. Never use combustible gases or any other reactive gas as a power source for this tool: explosion and serious personal injury could result. Fig. 3 & Fig. 4.
Technical Service Manager
Porter-Cable Corporation
4825 Highway 45 North
Jackson, TN 38305
Fig. 1
Fig. 2
Fig. 3
Fig. 4
3
904461 - 09-04-02.qxd 9/23/02 8:21 AM Page 4
7. Wear ear protection to safe-guard |
Fig. 5 |
|
against possible hearing loss. Fig. 5. |
||
|
8.Use clean, dry, regulated, compressed air at 70 to 120 PSI, (4.8 to 8.3 BAR). Fig. 6.
9.Do not connect tool to pressure which potentially exceeds 200 PSI (13.7 BAR).
10.Only use air hose that is rated for a maximum working pressure of at least 150 PSI (10.3 BAR) or 150% of the maximum
system pressure, which ever is greater. |
Fig. 6 |
11.Connect tool to air supply hose with a coupling that automatically removes all pressure from the tool when the coupling is disconnected. Fig. 7.
12.Disconnect tool from air supply hose before doing tool maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, or handing the tool to another person. Fig. 7.
13.Never use a tool that is leaking air, has missing or damaged parts, or requires repair. Make sure all screws and caps are securely tightened. Fig. 8.
14.Never use tool if safety, trigger or springs are inoperable, missing or damaged. Do not alter or remove safety, trigger, or springs. Make daily inspections for free movement of trigger and safety mechanism. Fig. 8.
15.Do not use tool without safety warning label. If label is missing, damaged or unreadable, contact your Porter-Cable Service Center for a replacement. Fig. 9.
16.Only use parts, fasteners and accessories approved by Porter-Cable.
17.Connect tool to air supply before
loading fasteners, to prevent a fastener |
Fig. 9 |
from being fired during connection. The tool |
|
driving mechanism may cycle when tool is |
|
connected to the air supply. Fig. 10. |
|
18.Always assume the tool contains fasteners. No horseplay. Respect the tool as a working implement. Fig. 11.
19.Operator and bystanders wear hard hat to safeguard against possible injuries. Fig.
20.Do not load fasteners with trigger or safety depressed, to prevent unintentional firing of a fastener. Fig. 13
21.Remove finger from trigger when not driving fasteners. Never carry tool with finger on trigger. In “Contact Actuation Mode” tool will fire a fastener if safety is bumped while trigger is depressed. Fig. 14.
Fig. 7
Fig. 8
Fig. 10