Pentax R-315EX-NX, R-323EX-NX, R-325EX-NX, R-326EX, R-335EX-NX User Manual

...
4 (1)

Total Construction Solutions

Electronic

Instruction Manual

Total Station

R-315EX(NX)

R-325EX(NX)

R-335EX(NX) R-300X Series BASIC

R-322EX(NX)

R-323EX(NX)

R-326EX

2-5-2 Higashi-Oizumi / Nerima-ku, Tokyo 178-0063, Japan

Tel.: +81-3-5905-1222 / Fax: + 81-3-5905-1225

E-mail: international@piic.pentax.co.jp

Website: http://www.pentax.co.jp/ppc

www.pentaxR300X.com

Before using this product, be sure that you have thoroughly read and understood this instruction manual to ensure proper operation.

After reading this manual, be sure to keep in a convenient place for easy reference.

Copyright © 2005 PENTAX Industrial Instruments Co., Ltd.

All Rights Reserved

PENTAX Industrial Instruments Co., Ltd. is a sole proprietor of the PTL software.

The PTL software and publication or parts thereof, may not be reproduced in any form, by any method, for any purpose.

PENTAX Industrial Instruments Co., Ltd. makes no warranty, expressed or implied, including but not limited to any implied warranties or merchantability or fitness for a particular purpose, regarding these materials and makes such materials available.

PRECAUTIONS REGARDING SAFETY

Safety precautions (Must be followed)

The following items are intended to prevent possible injury to the user or other people and/or damage to the instrument before it occurs. These safety precautions are important to the safe operation of this product and should be observed at all times.

Distinctive displays

The following displays are used to distinguish precautions by the degree of injury or damage that may result if the precaution is ignored.

WARNING

Items indicated by this display are precautions which if ignored would result in serious injury.

CAUTION

Items indicated by this display are precautions which if ignored may result in injury or material.

Here “injury” refers to injuries such as cuts, burns or electric shock the treatment of which will not likely require hospitalization or long-term attention.

“Material damage” refers to damage to facilities, buildings, acquired data, etc.

Before using this product, be sure that you have thoroughly read and understood this instruction manual to ensure proper operation. After reading this manual, be sure to keep it in a convenient place for easy reference.

This instrument complies with the protection requirement for residential and commercial areas. If this instrument is used close to industrial areas or transmitters, the equipment can be influenced by electromagnetic fields.

Three R-300X Quick Reference Guide are provided in your carrying case. They are

1.Basic Procedures,

2.Power Topo Lite Operating Procedures

3

PRECAUTIONS REGARDING SAFETY

WARNING

Do not stare into the laser beam directly as this may result in damage to your eyes. R-300X is a Class II Laser product. (The reflectorless type is a Class IIIa (3R) laser product.)

Do not look into the laser radiation aperture directly as this may result in damage to your eyes.

Never use the telescope to view intense light such as direct sunlight or sunlight reflected through a prism as this may result in loss of sight.

Do not disassemble, modify or repair this product as there a risk of laser radiation. Do not aim the laser beam at a person as it is harmful to the eyes and body. Receive

the examination treatment by the doctor when the eyesight or body trouble is doubted by any chance.

Electro-Magnetic Compatibility (EMC):

This instrument complies with the protection requirement for residential and commercial areas. If this instrument is used close to industrial areas or transmitters, the equipment can be influenced by electromagnetic fields.

Do not use this product in a coal mine, in a location where there is coal dust, or near flammable material as there is a risk of explosion.

Do not disassemble, modify or repair this product as there is a risk of fire, electric shock and burn injury. If you think the product requires repair, contact the retail outlet where you purchased it or an authorized repair site.

Only use the BC03 battery charger intended for this product as the battery charger. Use of another battery charger entails a risk of fire or burn injury from the battery bursting into flames due to possible differences in voltage or polarity.

Do not use a damaged electric cord plug or loose electric outlet when charging as there is a risk of fire or electric shock.

Do not charge the battery while covered by clothes or similar item as there is a risk of fire if the clothes ignite.

Do not use the battery or charger when wet as there is a risk of fire and burn injury due to short-circuit.

To prevent making short-circuit when removing the battery and charger from the case and storing them, apply electrically resistant tape to the poles of the battery. Storing the battery and charger as-is may result in fire or burn injury due to short-circuit.

Do not throw the battery into fire or expose it to heat as there is a risk of injury if it explodes.

4

PRECAUTIONS REGARDING SAFETY

CAUTION

For security, please do the opening inspection and inspection every a fixed period and adjustment.

When the laser beam enters eyes, an unexpected accident might be caused by the blink of eyes. Establish the laser product to avoid the height of eyes of a driving person and walker.

Establish an instrument so that laser beam does not hit a reflection thing as a mirror and a glass window. The refection beam of the laser is also harmful to the human body.

Besides the time when you measure the distance, cut off the power supply or shade the beam of aperture with caps.

Keep the laser product in the place where the person who does not have the product knowledge such as children does not touch by mistake.

Destroy the power supply mechanism of the instrument so as not to emit the laser beam when throwing away it.

Do not remove the handgrip without good reason. If it does come off, be sure to attach it securely to the instrument with screws. If it is not fastened securely, the instrument may fall when you grasp the handgrip, leading to possible injury.

Do not short the poles of the battery or charger as there is a risk of injury or fire.

Do not touch any fluid which may leak from the battery as there is a risk of chemical burn injury or reaction.

Do not insert or remove the electric plug with wet hands as there is a risk of electric shock.

Do not use the case to stand on as it is slippery and unstable and may cause you to fall, resulting in possible injury.

Be sure the tripod itself and the instrument on the tripod are both installed securely as insecure installation may cause the tripod to fall over or the instrument to drop, resulting in possible injury.

Do not carry the tripod with the metal shoe pointing toward another person as the person may be injured if they strike him or her.

The instrument contains a rechargeable battery and it is rechargeable.

At the end of its useful life, it may be illegal to dispose of the battery.

Check with your local solid waste officials for details for recycling.

5

PRECAUTIONS REGARDING SAFETY

Usage precautions

Surveying instruments are high-precision instruments. In order to assure that the Electronic Total Station R-300X series product which you have purchased

will provide long-lasting maximum performance, the precautions in this manual must be followed. Be sure to follow these instructions and use this product properly at all times.

[Solar observation] WARNING

Never view the sun directly using the telescope as this may result in loss of sight. Never point the objective lens directly at the sun as this may damage internal components. When using the instrument for solar observation, be sure to attach the special solar filter (MU64) designed for this product to the objective lens.

[Laser beam]

Do not stare into laser beam. R-300X is a class-II Laser product. (The reflectorless type is a Class IIIa (3R) laser product.)

[EDM axis]

The R-300X series EDM is the red visible laser beam and the beam diameter is very small. The beam is emitted from the objective center and the base plate center hole. The EDM axis is designed to coincide with the telescope sight axis but both axes may not sometimes coincide slightly according to the intense temperature change and time lapse.

[Target constant]

Confirm the Target Constant of the instrument before measurement.

If a different constant is to be used, use the correct constant of the target. The constant is stored in the instrument's memory when turned off.

[Reflectorless and reflector sheet]

Reflectorless:

The measurement range and accuracy of Reflectorless are based on the condition that laser beam is emitted perpendicular to the white side of the Kodak Gray Card.

The measurement range may be influenced by the shape of the target and its environment. There is a possibility that the range may vary when the target does not satisfy the conditions above at survey work.

Pay attention to following in case of distance measurement by Reflectorless. In a situation resulting in low accuracy, perform the distance measurement by Reflector sheet or Prism. (R-315NX, R-325NX, R-335NX, R-322NX, R-323NX)

There is a possibility that correct distance measurement may be impossible by dispersion or reduction of laser beam when the laser beam comes into the target from diagonal angle.

6

PRECAUTIONS REGARDING SAFETY

There is a possibility that the instrument cannot calculate correctly when receiving reflected laser beam from forth and back directions in case of measuring the target on the road.

There is a possibility that synthesized values are calculated and the distance may become longer or shorter than the actual one when the operator measure the target of slope or sphere or rugged shape.

There is a possibility that the instrument cannot calculate correctly by collecting the reflected laser beam from a man or a car that comes and goes in front of the target.

When using reflector sheet, set the reflector sheet to have its surface be approx. vertical to the aiming line. If it is positioned not to be approx. right angle, there is a possibility that correct distance measurement may be impossible by dispersion or reduction of laser beam.

In the following environments, the distance might not be able to be measured.

There is a reflection things (mirror, stainless board and white wall, etc.) in the direction of the target and under too strong sun light.

[Battery & charger]

Never use any battery charger other than the BC03 battery charger as this may result in damage to the instrument.

If water should happen to splash on the instrument or the battery, wipe it off immediately and allow it to dry in a dry location. Do not put the instrument in the case until it is completely dry as this may result in damage to the instrument.

Turn off the power when removing the battery from the instrument as removing the battery while the power is still on may result in damage to the instrument.

The battery mark displayed on the instrument is only an estimate of remaining battery power and is not completely accurate. Replace the battery quickly when it is about to run down as the time a battery lasts on one charge differs depending on conditions of ambient temperature, and the measurement mode of the instrument.

• Confirm the battery level remaining before operating.

[Auto focus]

The Auto focus mechanism is very precise but will not function under every condition. Focusing depends on brightness, contrast, the shape and size of the target.

In such a case, press the AF button and focus on the target by operating the Power focus key or the AF ring.

[LD POINT, laser pointer]

When you make a correct direction using the “LD POINT”, aim the laser beam at the wall and mark the center and then confirm the discrepancy between the reticle center and the marked point beforehand.

7

PRECAUTIONS REGARDING SAFETY

[Storage and operating environment]

To prevent making short-circuit when removing the battery and charger from the case and storing them, apply electrically resistant tape to the poles of the battery. Storing the battery and charger as is may result in fire or burn injury due to short-circuit.

Avoid storing the instrument in places subject to extreme high, low or radically fluctuating temperature. (Ambient temperature range during use: –20° C to +50° C)

Distance measurements may take longer when atmospheric conditions are poor such as when heat shimmer is present. When storing the instrument, always put it in its case and avoid storage in dusty location or location subject to vibration or extreme heat or humidity.

Whenever there is a sharp temperature difference between the instrument’s storage and usage locations allow the instrument to adjust to the ambient for an hour or more before use. Be sure to protect the instrument from the sun if the location is subject to intense direct sunlight.

During surveys for which the survey precision or atmospheric measurement method has been defined measure the atmospheric temperature and pressure separately and enter those values rather than using the Automatic Atmospheric Correction function.

The battery should be charged approximately once per month if the instrument is to be stored for an extended period of time.The instrument should also be removed from its case occasionally and aired out.

In addition to these precautions, be sure to handle the instrument properly at all times following the descriptions given in the various sections of this manual to assure safe and proper measurements.

[Transporting and carrying the instrument]

Be careful to protect this instrument from shock of impact and excessive vibration which may result in damage during transportation and shipment.

When transporting the instrument, always put it in the case and wrap shockabsorbing material around it and be sure it is handled as “FRAGILE”.

[Checks and repairs]

Always check the instrument before beginning work and check that the instrument is maintaining the proper level of precision. Pentax bears absolutely no responsibility for damages due to survey results obtained from surveys conducted without an initial instrument check.

Never disassemble the instrument, battery or charger even if you do detect an abnormality as there is a risk of fire or electric shock due to short-circuit. If you think the product requires repair, contact the retail outlet where you purchased it or an authorized repair site.

8

CONTENTS

PRECAUTIONS REGARDING SAFETY

3

SAFETY PRECAUTIONS (MUST BE FOLLOWED)

3

USAGE PRECAUTIONS

6

1. BEFORE USING THE INSTRUMENT

12

1.1

NAMES OF PARTS

12

1.2

UNPACKING AND PACKING

14

1.3

STANDARD EQUIPMENT

14

1.4

ATTACHING AND CHARGING THE BATTERY

15

2. DISPLAY AND KEYBOARD

18

2.1

DISPLAY AND KEYBOARD

18

2.2

OPERATION KEY

18

2.3

FUNCTION KEY

19

2.4

ALPHANUMERIC INPUT

21

2.5

LD POINT, LASER POINTER

21

3. PREPARATION FOR SURVEYING

22

3.1

CENTERING AND LEVELING OF THE INSTRUMENT

22

3.2

LASER PLUMMET

23

3.3

OPTICAL PLUMMET (OPTION)

24

3.4

LEVELING WITH CIRCULAR VIAL

25

3.5

LEVELING WITH ELECTRONIC VIAL

25

3.6

EYEPIECE ADJUSTMENT

27

3.7

TARGET SIGHTING

27

3.8

ATTACHMENT AND DETACHMENT OF TRIBRACH

31

4. TURNING THE POWER ON

32

4.1

TURNING THE POWER ON AND OFF

32

4.2

ADJUSTING LCD CONTRAST

33

4.3

ADJUSTING ILLUMINATION BRIGHTNESS

33

4.4

ADJUSTING RETICLE ILLUMINATION

34

5. ANGLE MEASUREMENT

35

5.1

MEASURING AN ANGLE

35

5.2

RESETTING THE HORIZONTAL ANGLE TO 0

35

5.3

HOLDING THE HORIZONTAL ANGLE

36

5.4

INPUTTING AN ARBITRARY HORIZONTAL ANGLE

36

5.5

DISPLAYING THE % SLOPE OF THE VERTICAL ANGLE

47

5.6CHANGING THE HORIZONTAL ANGLE FROM

CLOCKWISE TO COUNTERCLOCKWISE

38

9

6. DISTANCE MEASUREMENT

39

6.1

TARGET SETTING

39

6.2

DISTANCE MEASUREMENT

41

6.3

QUICK MODE

42

7. CORRECTION MODE

43

7.1

CHANGING THE TARGET CONSTANT

43

7.2

CHANGING THE TEMPERATURE

44

7.3

CHANGING THE ATMOSPHERIC PRESSURE

45

7.4

CHANGING THE PPM VALUE

46

8. INITIAL SETTING

48

8.1

OVERVIEW

48

8.2

ENTERING THE MODE FOR INITIAL SETTING 1

48

8.3

ENTERING THE MODE FOR INITIAL SETTING 2

49

8.4

ENTERING THE MODE FOR INITIAL SETTING 4

49

8.5

ENTERING THE MODE FOR INITIAL SETTING 5

49

8.6

SETTING OF [DATE AND TIME]

50

8.7EXAMPLE OF CHANGING AN INITIAL SETTING CONTENT

 

(SELECTION OF ATMOSPHERIC CORRECTION)

50

8.8

INITIAL SETTING 1

50

8.9

INITIAL SETTING 2

51

8.10

INITIAL SETTING 4

55

8.11

INITIAL SETTING 5

55

8.12

INITIAL SETTING OF DATE AND TIME

56

9. ACCESSING THE FUNCTIONS

57

9.1

ACCESSING BY HELP KEY

57

9.2

ACCESSING BY 007

57

10. CHECKS AND ADJUSTMENTS

59

10.1

ELECTRONIC VIAL

59

10.2

CIRCULAR VIAL

60

10.3

VERTICAL RETICLE

61

10.4

PERPENDICULARITY OF LINE OF SIGHT TO HORIZONTAL AXIS

62

10.5

VERTICAL 0 POINT ERROR

63

10.6

LASER PLUMMET

63

10.7

OPTICAL PLUMMET

64

10.8

OFFSET CONSTANT

65

10.9

BEAM AXIS AND LINE OF SIGHT

65

10.10 THE EDM BEAM AXIS

66

11. SPECIFICATIONS

67

12. DATA COLLECTOR

69

10

13. APPENDIX

70

13.1

ERROR MESSAGES

70

13.2

ATMOSPHERIC CORRECTION

71

13.3

HPA AND MMHG CONVERSION TABLE

72

13.4

ERROR WHEN NO ATMOSPHERIC CORRECTION IS MADE

72

13.5

ATMOSPHERIC REFRACTION AND EARTH CURVATURE CORRECTION

73

13.6

DISTANCE RANGE

74

14. NOTICE TO THE USER OF THIS PRODUCT

75

11

1. BEFORE USING THE INSTRUMENT

1.1 Names of parts

Collimator

Power focus key

Eyepiece

Circular vial

Display panel

Key board

Circular vial

Leveling screw

Focusing knob

AF button

Laser indicator

Instrument height mark

Battery latch

Battery pack Telescope tangent screw

Telescope clamp screw

Clamp screw

Tangent screw

Detaching knob

Base plate

R-325EX(NX)/ R-322EX(NX)/ R-323EX(NX): Detachable type

12

Top handle

Objective lens

Centering knob

R-335EX (NX): Shift type

• Dual display panel is an optional accessory.

13

1.2 Unpacking and packing

[Unpacking the Instrument from the case]

1Set the case down gently with the lid facing upwards.

2Open the latches while pressing down on the lock (safety mechanism) and open the lid of the case.

3Remove the instrument from the case.

[Packing the instrument in the case]

1Make sure the telescope is fairly level and lightly tighten the telescope clamp screw.

2Line up the housing marks (round yellow marks on the instrument) and tighten the upper and lower clamp screws.

3With the housing marks facing upward, set the instrument gently in the case without forcing it.

4Close the lid to the case and secure the latches.

1.3 Standard equipment

1Instrument

2Carrying case

3BP02 battery

4BC03/AC01 charger

5Plumb bob

6Hexagonal wrench

7Rain cover

8Quick Reference Guide (Basic, PTL procedures)

9CD-R (Basic operation & Special Functions manual)

14

Pentax R-315EX-NX, R-323EX-NX, R-325EX-NX, R-326EX, R-335EX-NX User Manual

1.4 Attaching and charging the battery

[Removing the battery]

1Turn the lock lever anticlockwise and remove the battery.

2Lift up the battery pack and remove it from the instrument.

Be absolutely sure to turn the power off when removing the battery as removing the battery while the power is still on may result in damage to the instrument.

1

2

[Attaching the battery]

1Align the guide grooves on the battery pack with the guide grooves on the instrument and push the top of the battery pack into place.

2Turn the lock lever clockwise to fix.

3

2

1

[Remaining battery charge]

When the instrument’s power is turned on, a battery mark “ ” will be displayed on the right of the display screen.This mark can be used to check the charge status of the battery.

Plenty of charge left

Get the spare battery ready

Replace with the spare battery

Low battery: Please change. Replace with the spare battery or charge.

15

[Charging the battery]

The battery BP02 is not charged at our factory shipment so charge it.

For BP02 charge, use the special BC03 charger.

Power supply cord

AC adaptor

Charger

[Connection of code]

1Insert the output plug of the power supply code in Jack of the AC adaptor.

2Insert the output plug of the AC adaptor in Jack of the charger.

3Insert the power supply plug of the power supply code in the outlet of AC power supply.

[Installation of battery]

1Draw the battery to the lock lever side and put it on the battery pocket. The battery is firmly installed on the battery pocket.

2Press down the battery and then slide it to the opposite direction of the lock lever.

3The lock lever goes up, and the battery is fixed.

4Under such a condition, if “Connection of the code” is done, the charge with the battery is begun.

Battery

Lock lever

Battery pocket

Charger

[Detaching the battery]

1Press the lock lever and slide the battery to the lock lever direction.

2Detach the battery packing from the battery pocket.

[Display panel]

1 Power lamp

4 Installation lamp

5 Discharge lamp

2 Charge lamp

3 Discharg button

16

1Power supply lamp (red) : Turns on when the power supply is turned on.

2Charge lamp (green): Turns on while charging and turns off when the charge is completed.

3Discharge lamp (yellow): Turns on when you push the discharge button. Turns off when the discharge is completed.

4Installation lamp (red): Blinks or turns on when the battery packing is attached normally. Blinks when charge or discharge and turns on when charge is completed.

(The charge lamp in the lower does not blink and does not turns on)

5Discharge button: Discharge lamp lights when you push this button, and the discharge of battery begins.

[How to charge]

1It begins charging automatically when you set the battery packing in the charger which beams the power supply lamp.

2Leave just as it is until the charge is completed.

3When the charge is completed, the charge lamp is turned off.

4Detach the battery packing from the charger when the charge is completed.

[Refreshing the battery]

The use time shortens gradually by the phenomenon of “Effect of the memory” when the NiMH battery leaves capacity and repeats the charge. The voltage recovers after refreshing and the use time returns normally in such a battery. Please refresh one degree every five times of the charge.

[Refreshing]

Set the battery in the charger as well as the case of the charge. Push the electrical discharge button. The electrical discharge lamp lights and the electrical discharge begins. The electrical discharge lamp is turned off when the electrical discharge ends, the charge lamp lights, and the charge starts automatically. Leave just as it is until the charge is completed. When the charge is completed, the charge lamp is turned off. Detach the battery from the charger.

[Time of refreshing and charge]

Battery BP02 is discharged from the state of a full charge at about 960 minutes and the charge is completed from the electrical discharge at about 130 minutes. However, the electrical discharge time is proportional to the remainder capacity of the battery. Moreover, the time required for refreshing might be different from the above-mentioned time according to a surrounding temperature and the state of the battery.

17

2. DISPLAY AND KEYBOARD

2.1 Display and keyboard

Alphanumeric and +/- key

Enter key

Power supply key

Function key

Illumination key

ESC key

Laser plummet and

 

 

 

 

Electronic vial key

2.2 Operation key

Key

Description

[POWER]

ON/OFF of power supply

[ESC]

Returns to previous screen or cancels an operation.

[ILLU]

Turns the illumination of the LCD display and telescope reticle on

 

and off.

[ENT]

Accepts the selected (highlighted) choice or the displayed screen

 

value.

[LASER]

Displays the laser plummet *1, electronic vial function, and the

 

LD point screen when you push the laser plummet/electronic vial

 

key.

 

(Refer to “2-5 Laser Pointer”, “3-2 Laser plummet”, and “3-5 Leveling

 

with Electronic vial”).

 

*1: Only the product with the laser plummet function

[Alphanumeric]

At the numerical value screen, the numerical value and the sign “.”

 

displayed are input. The English characters printed right under

 

numeric of each key are input.

[HELP]

Pressing [lLLU]+[ESC] key causes a help menu to appear in

 

A MODE or B MODE or causes a help message to appear.

18

2.3 Function Key

Display

F. Key

Description

MODE A

 

 

[MEAS]

F1

Pressing this key one time measures the distance in

 

 

normal mode another measurement type can be selected

 

 

by Initial Setting 2. Pressing this key twice measures the

 

 

distance in coarse mode another measurement type can

 

 

be selected by Initial Setting 2.

[TARGET]

F2

Select the target type by following order.

 

 

SHEET/ REFRECTORLESS /PRISM

 

 

(Reflectorless type instrument)

 

 

SHEET/PRISM

 

 

(Prism type instrument)

[0 SET]

F3

Resets the horizontal angle to 0° 0’ 0” by pressing twice.

[DISP]

F4

Switches the display composition in the order

 

 

“H.angle/H.dst./V.dst.”, “H.angle/V.angle/S.dst.” and

 

 

“H.angle/V.angle/H.dst./S.dst./V.dst.”

[MODE]

F5

Switches the screen between MODE A and MODE B.

MODE B

 

 

[S.FUNC]

F1

PowerTopoLite

[ANG SET]

F2

Brings up the angle setting screen for setting angle-related

 

 

parameters

 

 

(H.ANGLE/%GRADE, H.ANGLE INPUT and R/L REVERSE).

[HOLD]

F3

Pressing this key twice retains (holds) the horizontal angle

 

 

shown on the display.

[CORR]

F4

Brings up the screen for changing the target constant,

 

 

temperature.

 

 

Pressure setting.

[MODE]

F5

Switches the screen between MODE A and MODE B.

19

Other functions

[

]

F1

Moves the cursor to the left.

[

]

F2

Moves the cursor to the right.

[

]

F1

Goes back five items on the screen.

[

]

F2

Goes forward five items on the screen.

[RETICLE]

F3

Changing the reticle illumination when pressing

 

 

 

illumination key.

[

]

F3

Moves the cursor up.

[LCD]

F4

Changing the LCD contrast when pressing illumination

 

 

 

key.

[

]

F4

Moves the cursor down.

[ILLU]

F5

Changing the LCD illumination when pressing

 

 

 

illumination key.

[CLEAR]

F5

Clear the figure.

[SELECT]

F5

Open the selection window.

 

 

 

 

[How to move the menu number] Example:

The cursor is located at Menu 1.

Press the numeric key 0 and 2 to move to Menu 2 or press [F4] [ ].

ANGLE SET

1.ANGLE / %GRADE:ANGLE

2.H.ANGLE INPUT: 092 30’ 20”

3.R/L REVERSE: RIGHT

SELECT

ANGLE SET

1.ANGLE / %GRADE:ANGLE

2.H.ANGLE INPUT: 092 30’ 20”

3.R/L REVERSE: RIGHT

SELECT

20

2.4 Alphanumeric input

The point name is inputted by the alphanumeric keys as following.

Key

Letter under key

Letter & figure order to input

[0]

 

[@][.][_][-][:][/][0]

[1]

PQRS

[P][Q][R][S][p][q][r][s][1]

[2]

TUV

[T][U][V][t][u][v][2]

[3]

WXYZ

[W][X][Y][Z][w][x][y][z][3]

[4]

GHI

[G][H][I][g][h][i][4]

[5]

JKL

[J][K][L][j][k][l][5]

[6]

MNO

[M][N][O][m][n][o][6]

[7]

 

[??][?][!][_][ ][^][|][&][7]

[8]

ABC

[A][B][C][a][b][c][8]

[9]

DEF

[D][E][F][d][e][f][9]

[.]

 

[.][,][:][;][#][(][)]

[+/-]

 

[+][-][*][/][%][=][<][>]

 

 

 

2.5 LD POINT, laser pointer

The Laser pointer function turns the laser beam on continuously to become the aiming point so that visual confirmation is possible.

1When the [LD POINT] key is pressed after pressing the [Laser] key, the Laser pointer function is turned on. The Laser indicator is turned on and the “ ” mark on the left of the screen blinks while the Laser pointer function is operating.

2If the [Laser] key is pressed and the [LD POINT] key is pressed while the Laser pointer function is operating, the Laser pointer function is turned off.

The beam of the sun is strong and visual confirmation is difficult in daytime when out doors.

The laser beam is designed not to be able to observe through the telescope.

Please visually align the laser beam to the target and mark the center.

Confirm the alignment (horizontal and vertical ) before measuring when performing accurate work like stake out when using the Laser pointer function.

Also refer to 10-10. The EDM beam axis.

Please do not look at the laser source of beam directly.

21

3. PREPARATION FOR SURVEYING

3.1 Centering and leveling of the instrument

[Setting up the instrument and the tripod]

1Adjust the tripod legs so that a height suitable for observation is obtained when the instrument is set on the tripod.

2Hang the plumb bob on the hook of the tripod, and coarse center over the station on the ground. At this time, set the tripod and fix the metal shoes firmly into the ground so that the tripod head is as level as possible, and the plumb bob coincides with the station on the ground.

3If the tripod head is mis-leveled by the action of fixing the metal shoes into the ground, correct the level by extending or retracting each leg of the tripod.

Instrument

Base plate

Tripod head

Center screw

Contract

Metal shoe

22

3.2 Laser plummet

[Laser plummet model]

The laser plummet is not set to be ON at factory shipping. The laser plummet operation of power supply ON can be set by command No 520, LD PLUM & E VIAL. For using Command number, refer to 9-2. Accessing by 007.

[For the Detaching type laser plummet equipment model]

Turn on the laser plummet function by pushing the Laser key.

Match the position with the leveling screw so that the laser mark coincides with the ground mark.

[For the Shift type laser plummet equipment model]

Turn on the laser plummet function by pushing the Laser key.

Match the position by the tripod so that the laser mark coincides with the ground mark.

The centering knob is loosened, and the upper plate is pushed by the tip of a finger, and a center mark is matched to the ground mark.

Tighten the centering knob.

Loosen the horizontal clamp screw, and rotate the instrument by 90°, and confirm the vial of the circular vial is at the center at any position.

Correct the vial with the leveling screw when the vial comes off from the center.

[Brightness adjustment of laser]

Sometimes the state of the surface of the ground mark or a surrounding environmental dose not allow observing the laser spot easily. Please adjust the brightness of the laser if necessary.

If the Laser key is pressed, the brightness adjustment screen of the laser plummet device, is displayed.

The Laser plummet becomes dark by, key and becomes bright by / key

The adjustment is completed with the ENT key and it returns to electronic vial screen.

LD PLUM. POWER ADJ

 

DOWN

 

 

 

UP

 

0

 

10

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENT

 

 

 

 

 

 

 

 

 

 

 

 

LD PLUM. POWER ADJ

 

 

 

 

 

 

 

 

DOWN

 

 

UP

 

0

 

10

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRONIC VIAL

T.COMP.

ON

30”/1DIV

LD POINT PLUM ADJ

SENS.

23

The brightness adjustment step of the laser is 10 steps.

The laser plummet spot can become difficult to see in bright sunlight which makes it difficult to perform the occasional check. In this case, use your foot or the carrying case to make a shadow over the laser position.

The laser plummet is adjusted to be within ±0.8mm at the instrument height of 1.5m at factory shipping.

Please confirm the amount of the gap (direction of X and Y direction) with the laser plummet beforehand compared with plumb bomb etc.

when working like accurately putting out a perpendicular direction using the laser plummet function.

Please do not look at the laser source of beam directly.

3.3 Optical plummet (Option)

[Detachable type]

1Look through the optical plummet eyepiece, and rotate the eyepiece knob until the center mark can be seen clearly.

2Rotate the focusing knob of the optical plummet and adjust the focus to the station on the ground.

3Rotate the levelling screws and aligh the center mark to the ground mark.

[Shift type]

1Look through the optical plummet eyepiece, and rotate the eyepiece knob until the center mark can be seen clearly.

2Rotate the focusing knob of the optical plummet and adjust the focus on the ground mark.

3Loosen the centering clamp screw and push the upper plate by finger and stay the center mark on the ground mark.

4Tighten the centering clamp screw.

5Loosen the horizontal clamp screw and rotate the instrument every 90° and confirm the Circular vial is centered correctly. If the bubble is not centered, it can be properly set using the leveling screws.

24