Features:
Fits 22" - 40" (56 - 102 cm) LCD screens
• Two tensionable pivot points for extensive adjustment of
viewing angle
• VESA
®
75/100/200 x 100/200 x 200 compatible
• Frees up space by folding flat against the wall
Paramount™ Pivot for 22" - 40" (56 - 102 cm) LCD screens
Models: PP740, PWV240/BK
Max Load Capacity: 80lb (36 kg)
©
U
L
USC
I
D
:
0
0
0
0
0
1
8
7
6
2
ISSUED: 02-05-09 SHEET #: 202-9312-1
2 of 20
ISSUED: 02-05-09 SHEET #: 202-9312-1
Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
Never exceed the Maximum Load Capacity. See page one.
If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud finder is highly recommended.
Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
Wood Stud Included
Wood Beam Included
Solid Concrete Included
Cinder Block Included
Metal Stud Do not attach except with Peerless Metal Stud Accessory Kit - WSP490;
Brick Contact Qualified Professional
Other or unsure? Contact Qualified Professional
WARNING
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Stud Wall ................................................................................................................................................4
Installation to Solid Concrete and Cinder Block .....................................................................................................................5
Attaching Adapter Plate to Screen with VESA
®
Mounting Pattern ..........................................................................................6
Installing to Peerless LC or PLP Model Adapter Bracket .......................................................................................................8
Cord Management and Arm Tension Adjustment ................................................................................................................10
NOTE: Read entire instruction sheet before you start installation and assembly.
Tools Needed for Assembly
stud finder ("edge to edge" stud finder is recommended)
phillips screwdriver
drill
5/16" (8 mm) bit for concrete and cinder block wall
5/32" (4 mm) bit for wood stud wall
level
3 of 20
ISSUED: 02-05-09 SHEET #: 202-9312-1
BE
H
CF
G
IJ
A
M
NO
D
KL
P
Parts may appear slightly different than illustrated.
Before you begin, make sure all parts shown are included with your product.
PWV240/B
K
PP740
Description
Qt
y
.
Part #
A
wall mount assembly
1
095-0545-GB
B
concrete anchor 2 590-0320
C
retaining spacer 4 590-5005
D
1/4-20 x 13 mm flat head phillips screw 2 520-1209
E
M4 x 10 mm phillips screw 4 504-9012
F
M4 x 20 mm phillips screw 4 504-9020
G
M6 x 12 mm phillips screw 4 520-1128
H
#14 x 63.5 mm flat head wood screw 2 520-1202
I
M6 x 20 mm phillips screw 4 520-9402
J
M6 x 30 mm phillips screw 4 510-9109
K
M5 x 6 mm phillips screw 5 520-1023
L
#10 flat washer 4 540-9400
M
hook bracket 1
095-P1346
N
adapter plate
1
095-P1322
O
#10-32 x 6 mm flat head phillips screw 1 520-1108
P cable tie 1 560-1725
Parts List
4 of 20
ISSUED: 02-05-09 SHEET #: 202-9312-1
Installation to Wood Stud Wall
Using a stud finder, locate and mark the edges of the wood stud used in mounting this product. Use of an edge to
edge stud finder is highly recommended. Use a level to draw a vertical line down the center of the stud. Use wall
plate as template to mark center of holes along the vertical line. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm)
deep. Attach wall mount (A) to wall using two #14 x 63.5 mm flat head wood screws (H) as shown.
Skip to step 2 on page 6.
A
H
WOOD STUD WALL
WALL PLATE
1
Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
Never tighten in excess of 80 in. • lb (9 N.M.).
Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder
is highly recommended.
Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations (not UL approved).
WARNING
5 of 20
ISSUED: 02-05-09 SHEET #: 202-9312-1
Installation to Solid Concrete and Cinder Block
Level and use wall plate as template to mark center
of holes.
Drill two 5/16" (8 mm) dia. holes to a
minimum depth of 2.5" (64 mm). Insert anchors (B)
in holes flush with wall. Place wall mount (A) over
anchors and secure with wood screws (H). Make
sure wall mount is level, and tighten all fasteners.
A
H
B
WALL PLATE
SOLID CONCRETE
CINDER BLOCK
1
CUTAWAY VIEW
INCORRECT CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90
specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
WARNING
Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
the screws, greatly reducing their holding power.
Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
Always attach concrete expansion anchors directly
to load-bearing concrete.
Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8" (16 mm), custom
fasteners must be supplied by installer.
WARNING
1
3
2
B
Drill holes and insert anchors (B).
Place plate (A) over anchors (B) and secure with screws (H).
Tighten all fasteners.
A
B
H
concrete
surface
6 of 20
ISSUED: 02-05-09 SHEET #: 202-9312-1
L
M
N
K
N
E
G
N
Attaching Adapter Plate to Screen with VESA
®
200 x 100
or 200 x 200 Mounting Pattern
Attach hook bracket (M) to adapter plate (N) using
four M5 x 6 mm screws (K) and #10 washers (L) as
shown.
2
FOR VESA
®
200 x 100 MOUNTING PATTERN:
Choose hole pattern as shown below. Attach
adapter plate (N) to back of screen using four M4 x
10 mm screws (E) as shown below.
*NOTE: If screw (E) gets less than three threads
of engagement, attach adapter plate (N) to back of
screen using four M4 x 20 mm screws (F) and four
spacers (C) as indicated below.
Skip to step 3 on page 9.
FOR VESA
®
200 x 200 MOUNTING PATTERN:
Choose hole pattern as shown below. Attach adapter
plate (N) to back of screen using four M6 x 12 mm
screws (G) as shown below.
*NOTE: If screw (G) gets less than three threads
of engagement, attach adapter plate (N) to back of
screen using four M6 x 20 mm screws (I). If screw (I)
still gets less than three threads of engagement, use
four M6 x 30 mm screws (J).
Skip to step 3 on page 9.
NOTE: For VESA 75 mm and 100 mm patterns, see following page.
2-1
If screws don't get three complete turns in the screen inserts or if screws bottom out and adapter plate is still not
tightly secured, damage may occur to screen or product may fail.
WARNING
*For screens with a
hole pattern in a pocket,
spacers (C) go between
adapter plate (N) and
screen.
C