• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud finder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
• Wood Stud Included
• Wood Beam Included
• Solid Concrete Included
• Cinder Block Included
• Metal Stud Do not attach except with Peerless Metal Stud Accessory Kit - WSP490;
• Brick Contact Qualified Professional
• Other or unsure? Contact Qualified Professional
WARNING
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Stud Wall ................................................................................................................................................4
Installation to Solid Concrete and Cinder Block .....................................................................................................................5
Installing to Peerless LC or PLP Model Adapter Bracket .......................................................................................................8
Cord Management and Arm Tension Adjustment ................................................................................................................10
NOTE: Read entire instruction sheet before you start installation and assembly.
Tools Needed for Assembly
•stud finder ("edge to edge" stud finder is recommended)
• phillips screwdriver
• drill
• 5/16" (8 mm) bit for concrete and cinder block wall
• 5/32" (4 mm) bit for wood stud wall
• level
3 of 20
ISSUED: 02-05-09 SHEET #: 202-9312-1
BE
H
CF
G
IJ
A
M
NO
D
KL
P
Parts may appear slightly different than illustrated.
Before you begin, make sure all parts shown are included with your product.
PWV240/B
K
PP740
Description
Qt
y
.
Part #
A
wall mount assembly
1
095-0545-GB
B
concrete anchor2590-0320
C
retaining spacer 4590-5005
D
1/4-20 x 13 mm flat head phillips screw2520-1209
E
M4 x 10 mm phillips screw4504-9012
F
M4 x 20 mm phillips screw4504-9020
G
M6 x 12 mm phillips screw4520-1128
H
#14 x 63.5 mm flat head wood screw2520-1202
I
M6 x 20 mm phillips screw4520-9402
J
M6 x 30 mm phillips screw4510-9109
K
M5 x 6 mm phillips screw5520-1023
L
#10 flat washer4540-9400
M
hook bracket1
095-P1346
N
adapter plate
1
095-P1322
O
#10-32 x 6 mm flat head phillips screw1520-1108
Pcable tie1560-1725
Parts List
4 of 20
ISSUED: 02-05-09 SHEET #: 202-9312-1
Installation to Wood Stud Wall
Using a stud finder, locate and mark the edges of the wood stud used in mounting this product. Use of an edge to
edge stud finder is highly recommended. Use a level to draw a vertical line down the center of the stud. Use wall
plate as template to mark center of holes along the vertical line. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm)
deep. Attach wall mount (A) to wall using two #14 x 63.5 mm flat head wood screws (H) as shown.
Skip to step 2 on page 6.
A
H
WOOD STUD WALL
WALL PLATE
1
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations (not UL approved).
WARNING
5 of 20
ISSUED: 02-05-09 SHEET #: 202-9312-1
Installation to Solid Concrete and Cinder Block
Level and use wall plate as template to mark center
of holes.
Drill two 5/16" (8 mm) dia. holes to a
minimum depth of 2.5" (64 mm). Insert anchors (B)
in holes flush with wall. Place wall mount (A) over
anchors and secure with wood screws (H). Make
sure wall mount is level, and tighten all fasteners.
A
H
B
WALL PLATE
SOLID CONCRETE
CINDER BLOCK
1
CUTAWAY VIEW
INCORRECTCORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90
specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).