Peavey PV 8 User Manual

0 (0)
PV®8
Compact Mixer Operations Guide
For more information on other great Peavey products, go to your local Peavey dealer or online at www.peavey.com
2
Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
CCAAUUTTIIOONN::
Risk of electrical shock — DO NOT OPEN!
CCAAUUTTIIOONN::
To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside.
Refer servicing to qualified service personnel.
WWAARRNNIINNGG::
To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture.
Before using this appliance, read the operating guide for further warnings.
Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” sin aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como para constituir riesgo de descarga eléctrica.
Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la operación y mantenimiento en la información que viene con el producto.
PPRREECCAAUUCCIIOONN::
Riesgo de descarga eléctrica ¡NO ABRIR!
PPRREECCAAUUCCIIOONN::
Para disminuír el riesgo de descarga eléctrica, no abra la cubierta. No hay piezas útiles
dentro. Deje todo mantenimiento en manos del personal técnico cualificado.
AADDVVEERRTTEENNCCIIAA::
Para evitar descargas eléctricas o peligro de incendio, no deje expuesto a la lluvia o
humedad este aparato Antes de usar este aparato, Iea más advertencias en la guía de operación.
Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur la présence d’une tension dangereuse pouvant être d’amplitude suffisante pour constituer un risque de choc électrique.
Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes instructions concernant l’utilisation et l’entretien de l’appareil dans le paragraphe signalé.
AATTTTEENNTTIIOONN::
Risques de choc électrique — NE PAS OUVRIR!
AATTTTEENNTTIIOONN::
Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à l’intérieur aucune pièce pouvant être reparée par l’utilisateur. Confiez I’entretien et la réparation de l’appareil à un réparateur Peavey agréé.
AAVVEERRTTIISSSSEEMMEENNTT
: Afin de prévenir les risques de décharge électrique ou de feu, n’exposez pas cet appareil à la pluie ou à l’humidité. Avant d’utiliser cet appareil, lisez attentivement les avertissements supplémentaires de ce manuel.
Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses warnen, die von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können.
Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die Handhabung und Wartung des Produkts betreffen.
VVOORRSSIICCHHTT::
Risiko — Elektrischer Schlag! Nicht öffnen!
VVOORRSSIICCHHTT::
Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden sich keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von qualifiziertem Fachpersonal durchführen lassen.
AACCHHTTUUNNGG::
Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem
Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
3
IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNSSTTRRUUCCTTIIOONNSS
WWAARRNNIINNGG::
When using electrical products, basic cautions should always be followed, including the following:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit from the apparatus.
11. Note for UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug‚ proceed as follows:
a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E‚ the earth symbol‚ colored green or colored green and yellow.
b) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black. c) The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red.
12. Only use attachments/accessories provided by the manufacturer.
13. Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
14. Unplug this apparatus during lightning storms or when unused for long periods of time.
15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in
any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
16. Never break off the ground pin. Write for our free booklet “Shock Hazard and Grounding.” Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.
17. If this product is to be mounted in an equipment rack, rear support should be provided.
18. Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Government’s Occupational and Health Administration (OSHA) has specified the following permissible noise level exposures:
Duration Per Day In Hours Sound Level dBA, Slow Response
890 692 495 397 2 100
1 1⁄
2
102
1 105
1
2
110
1
⁄4or less 115
According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or protectors to the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, if exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation.
SSAAVVEE TTHHEESSEE IINNSSTTRRUUCCTTIIOONNSS!!
4
PV®8Compact Mixer
Description
Congratulations on purchasing the Peavey PV8 compact mixer. The PV8 is a studio-quality mixing console designed to meet diverse needs while occupying only a small space. This is the perfect console for small venue performances or home recording environments.
Please read this guide carefully to ensure your personal safety as well as the safety of your equipment.
Features
Four XLR Mic inputs
Two stereo channels with RCA and 1⁄4" inputs
Three-band channel EQ
A/B stereo input selector reduces patching
Inserts on all mono channels
Clip LEDs that thoroughly monitor clipping
48V phantom power switch
Effects send on every channel with stereo return
Monitor send on every channel
Zero latency record monitoring capabilities
Control room output with level control
Contour control switch
80 Hz low-cut switch
EENNGGLLIISSHH
5
Gain (1)
This control establishes the nominal operating level for the channel. The input gain can be adjusted over a wide range to compensate for soft voices or very loud drums. To maximize the signal-to-noise ratio the gain should be set to the proper level with the channel level control (9) set to 0. If the clip LED comes on and remains lit, try reducing
the gain.
Hi EQ (2)
An active tone control (shelving type: ±15 dB) that varies the level of the high frequency range.
Mid EQ (3)
An active tone control (peak dip: ±15 dB) that varies the mid frequency range.
Low EQ (4)
An active tone control (shelving type: ±15 dB) that varies the level of the low frequency range.
Caution: Excessive low frequency boost causes greater power consumption and increases the possibility of speaker damage.
MON Send (5)
This control adjusts the level of the channel signal sent to the monitor output. The signal is taken before the channel level control but after the channel EQ.
EFX Send (6)
This control adjusts the level of the channel signal added to the effects mix. The effects send signal is taken after the channel level controls (9) so that adjustments made to the level control will also affect the send level.
Pan (7)
This knob controls the placement of the signal in the stereo field. When rotated completely counterclockwise‚ the signal is present only on the left channel; when rotated completely clockwise‚ only in the right channel. On stereo channels 5/6 and 7/8, this control functions as a balance control to adjust the relative level of the left and right signals.
Clip LED (8)
This light normally indicates that the channel signal level is nearing the overload point. The clip indicator circuit monitors the signal at many points in the channel to ensure that it catches all instances of clipping. It illuminates at +19 dBu and warns that the gain or EQ boost should be reduced. When it lights, roughly 3 dB of headroom remain.
Level (9)
This is the channel output level control. The optimum setting is the 0 (unity gain) position.
FF RR OO NN TT PP AA NN EE LL
1
2
3
5
6
8
9
4
7
6
Phantom Power LED (10)
This LED lights when the Phantom Power Switch (11) has been engaged.
Phantom Power Switch (11)
Applies +48 VDC Voltage to the input XLR connectors to power microphones requiring phantom power.
If phantom power is used, do not connect unbalanced dynamic microphones or other devices to the XLR inputs that cannot handle this Voltage. The Phantom Power LED (10) indicates when phantom power is on.
EFX/Return (12)
The EFX/Return Level Control adjusts the level sent to the Left/Right main bus from the return inputs (30).
Tape To CTRL/HP (13)
Depressing this switch adds the tape return to the Control Room (32) and Headphone Outputs (20) for zero latency monitoring.
Tape to Mix (14)
Depressing this switch routes the signal from the Tape Inputs (38) to the Main Outputs (31).
Power LED (15)
This LED indicates AC power is supplied to the unit‚ the power switch is on and the unit is functioning properly.
MON Send Master (16)
This is the master output level control for the monitor mix. The output level sent to the Monitor Send jack (33) is controlled by the channel monitor send controls (5) and by this master control.
EFX Send Master (17)
This is the master output level control for the EFX mix. The output level sent to the EFX Send jack is controlled by the channel level controls (9), the channel EFX send controls (6) and by this master control.
Contour Switch (18)
Engaging this switch enhances the signal by adding both bass and treble frequencies. This is especially effective at lower volumes or for tape/CD playback.
80 Hz Low Cut (19)
The Low Cut filter has a corner frequency of 80 Hz. When engaged‚ it can improve clarity by removing low frequencies that can make a mix sound muddy. This feature is especially useful when playing outside on a windy day or on a hollow‚ noisy stage. These kinds of ambient noises can rob your sound system of power. Engaging this switch
will remove those frequencies from the system and restore power to where it’s needed.
Headphone Output (20)
The Headphone Output is a
1
4
"
TRS (tip= left; ring = right; sleeve = ground). The signal sent to this output is
normally the Left/Right mix. When the Tape to Control Room switch is engaged, the tape input signal is added to the Left/Right mix and can be monitored in the headphones.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Mic (XLR) Inputs (24)
XLR balanced inputs optimized for a microphone or other low impedance source. Pin 2 is the positive input. Because of the wide range of gain adjustment, signal levels up to +14 dBu can be accommodated.
Line (1⁄4”) Inputs (25)
1
4balanced (TRS) 10 k Ohm impedance input. The tip is the positive input and should be used for unbalanced
inputs. It has 20 dB less gain than the XLR input and does not have phantom power available. The Mic and Line inputs should not be used simultaneously.
Insert (26)
1
4” TRS Connector allows external signal processors to be inserted into the channel signal path. Tip=Send;
Ring=Return; Sleeve=Ground.
Stereo (1⁄4") Inputs (27)
These 1⁄4" unbalanced inputs work as a stereo line input using both jacks or as a mono input if the connection is made to the Left/Mono input only. The A/B input selector must be in the "A" position for these jacks to be active.
RCA Inputs (28)
These RCA inputs work as stereo line inputs. The A/B input selector must be in the "B" position for these jacks to be active.
A/B Switch (29)
The A/B input selector switch expands the capability of the PV®8 mixer by allowing two stereo sources to be connected to each stereo line input. Instead of re-patching, the switch selects which input jacks are active.
Headphone Level (21)
This knob sets the headphone and control room output levels. To avoid damage to your hearing‚ make sure to turn the dial fully counterclockwise before using headphones. Slowly turn the knob clockwise until a comfortable listening level is set. Normally, the signal in the headphones is the Left/Right signal. If the Tape to Control Room (13) is engaged‚ the tape signal is also included.
LED Meters (22)
Two six-segment LED arrays are provided to monitor the levels of the main Left/Right outputs. These meters range from -20 dB to +19 dB. 0 dB on the meter corresponds to +4 dBu at the outputs.
Master Level Fader (23)
The Master Fader controls the level sent to the main Left/Right outputs. Best results are obtained when this control is set near the 0 point.
7
RR EE AA RR PP AA NN EE LL
24
25
26
27
30
28
29
32 34
33
31
EFX Return (30)
The EFX Return inputs (Left/Mono‚ Right) feature two 1⁄4" TS jacks. These inputs can be used with Tip‚ Ring, Sleeve (TRS) balanced or Tip, Sleeve (TS) unbalanced connectors. The EFX Return is controlled via the EFX/Return Level Control (19).
Left/Right Outputs (31)
The Left/Right Outputs feature two 1⁄4" TRS Z-balanced jacks. These outputs can be used with Tip‚ Ring, Sleeve (TRS) balanced or Tip, Sleeve (TS) unbalanced connectors.
Control Room Outputs (32)
The Control Room Outputs feature two 1⁄4" TRS Z-balanced jacks. These outputs can be used with Tip, Ring, Sleeve (TRS) balanced or Tip, Sleeve (TS) unbalanced connectors. The Control Room Output Level is adjusted with the Headphone Level Control (21).
MON Send (33)
The MON Send features a 1⁄4" TRS Z-balanced jack in the master section. This output can be used with the Tip, Ring, Sleeve (TRS) balanced or Tip, Sleeve (TS) unbalanced connectors. The MON mix is determined by the amount of signal being sent to the MON bus in each channel and by the Monitor master control.
EFX Send (34)
The EFX Send features a 1⁄4" TRS Z-balanced jack in the master section. These outputs can be used with Tip‚ Ring, Sleeve (TRS) balanced or Tip, Sleeve (TS) unbalanced connectors. The EFX mix is determined by the amount of signal being sent to the EFX bus in each channel and by the EFX Master Control.
Power Adapter Input (35)
Use to connect the included power supply. Be sure the power supply is connected to the PV®8 before connecting to a power source. Use 16 VAC 1 A adapter only.
Note: Replace only with Peavey part number 70902571 for Domestic or 70902572 for Export.
Power Switch (36)
Depressing the power switch supplies power to the unit.
Tape In/Out (38 & 37)
The tape input jacks are designed to accommodate tape‚ CD or computer sound card output levels. The output level is +4 dBu for connection to a recorder or sound card input. The tape inputs can be used as an additional stereo input by engaging the Tape to Main Mix switch (14). The tape input can also be used to monitor the recorder/sound card output without the risk of feedback.
8
35
36
37
38
9
PAN
Meridian, MS 39301
Peavey Electronics Corp.
P. O. Box 2898
Sheet Title:
Title:
Sheet
Date:
of
B
A
21
B
A
21
C
4
HI PASS
HI PASS
+48V
BALANCE
CONTOUR
LO HI
CONTOUR
LO HI
EQ
LO MID HI
EQ
LO MID HI
EQ
LO MID HI
+
-
RIGHT
TAPE -L/R SELECT
POWER
PHANTOM
RIGHT
LEFT
LINE
RIGHT
LEFT
XLR
LEVEL
EFX RETURN
LEFT/MONO
RIGHT
TAPE OUTPUT
HEADPHONES
CONTROL ROOM
TAPE TO MIX
LEFT
RIGHT
MAIN OUTPUTS
TAPE INPUT
GLOBAL
CONTROL ROOM
TAPE TO
GAIN
INSERT
CLIP
EFX
MON
EFX
MON
LEFT/MONO
RIGHT
EFX
MON
LEFT
SELECT
INPUT
EFX SEND
MON SEND
CLIP
LED METER
MONO INPUT CHANNEL 1-4
STEREO INPUT CHANNEL 5/6 - 7/8
231
PV8_BLOCK
4-9-2004_11:2522
PV
®
8 Block Diagram
10
PPVV®88 CCoommppaacctt CCoonnssoollee
SSPPEECCIIFFIICCAATTIIOONNSS
Function
Microphone (150 Ohms)
Line (10 k Ohms)
Stereo Line Input
Aux Returns
Tape
Input Z
(Ohms min)
2.2 k
10 k
10 k
10 k
10 k
Input Gain Setting
Max Gain (63 dB)
Min Gain (10 dB)
Max Gain (43 dB)
Min Gain (-10 dB)
Max Gain (20 dB)
Nominal
N/A (0 dB)
N/A (10 dB)
Nominal*
-59 dBu
-6 dBu
-39 dBu
+14 dBu
+16 dBu
-2 dBu
+4 dBu
-10 dBV
Max
-41 dBu
+12 dBu
-21 dBu
+32 dBu
+2 dBu
+16 dBu
+22 dBu
+12 dBu
Bal/Unbal
Bal
Bal
Unbal
Unbal
Unbal
Connector
XLR Pin 1 Gnd Pin 2 (+)‚ Pin 3 (-1)
1
⁄4"TRS; Tip (+)‚ Ring (-)‚ Sleeve Ground
1
4" TS; Tip (+)‚ Sleeve Ground
1
4" TRS; Tip (+)‚ Sleeve Ground
RCA Phono
Input Levels
Min**
-83 dBu
-30 dBu
-63 dBu
-10 dBu
-40 dBu
-26 dBu
-17 dBu
-17 dBu
Function
Main Left/Right
Effects and Monitor Sends
Headphone
Tape
Min Load Z
(Ohms)
600
600
8
2.2 k
Nominal
+4 dBu
+4 dBu
+4 dBu (no load)
+4 dBu
Max
+22 dBu
+22 dBu
+22 dBu
+22 dBu
Bal/Unbal
Bal
Bal
Unbal
Unbal
Connector
1
4" TRS: Tip (+), Ring (-),
Sleeve Ground
1
4" TS, Tip (+)‚ Sleeve Ground
1
4" TRS; Tip Left‚ Ring Right‚
Sleeve Ground
RCA Phono
Output Level
0 dBu = 0.775 V (RMS)
** Min Input Level (sensitivity) is the smallest signal that will produce nominal output (+4 dBu) with channel and master faders set for maximum gain. * Nominal settings are defined as all controls set at 0 dB (or 50% rotation for rotary pots) except the gain adjustment pot which is as specified.
0 dBu = 0.775 V (RMS)
Inputs
Outputs
Gain
Mic Input Gain Adjustment Range: 10 dB to 60 dB
Mic Input to Left/Right Balance Output 87 dB (max gain)
Line Input Gain Adjustment Range: -10 dB to 40 dB
Line Input to Left/Right Balance Output 67 dB (max gain)
Stereo Line Input Gain Adjustment Range: Off to +20 dB
Stereo Line Input to Left/Right Output 44 dB (max gain)
Aux Return to Left/Right Balance Output 21 dB (max gain)
11
Output
Master Left/Right
Monitor Send
Effects Sends
Residual Noise
-98 dBu
-90 dBu
-84 dBu
-103 dBu
-84 dBu
-103 dBu
-84 dBu
S/N Ratio (Ref: +4 dBu)
102 dB
94 dB
90 dB
107 dB
88 dB
107 dB
88 dB
Test Conditions
Master Fader Down‚ Channel Levels Down
Master Fader Nominal‚ Channel Levels Down
All controls nominal‚ mic gain minimum
All controls off
All channel sends nominal, masters nominal
All controls off
All channel sends nominal, masters nominal
(Hum and noise measurements: 22 Hz to 22 kHz BW)
Frequency Response
Mic Input to Left/Right Output 14 Hz to 25 kHz +0 dB/-1 dB
Total Harmonic Distortion
<0.01% 20 Hz to 20 kHz Mic to Left/Right Output (10 Hz to 80 kHz BW) <0.005% Typical <0.0007% Mic Pre-amp Distortion
Equivalent Input Noise (EIN)
-129 dBu (input terminated with 150 Ohms)
Crosstalk
>80 dB Adjacent Input Channels (1 kHz) >75 dB Left to Right Outputs (1 kHz)
Common Mode Rejection Ratio (Mic Input)
50 dB minimum (20 Hz to 20 kHz) 70 dB typical @ 1 kHz
Meters
6 segment, peak reading (0 dB = +4 dBu)
Signal/Overload Indicators
Red LED lights 3 dB below clipping
Dimensions
9.32" (23.7 cm) wide x 11.625" (29.5 cm) deep x 2.76" (7.0 cm) high
Weight
Without power supply: 5.7 lbs. (2.58 kg) With power supply: 7 lbs. (3.17 kg)
Power Requirements
Domestic: 16 VAC 60 Hz; 12 Watts nominal
Hum and Noise
Loading...
+ 25 hidden pages