Peavey PV 6 User Manual

0 (0)
Peavey PV 6 User Manual

PV®6 Compact Mixer Operations Guide

For more information on other great Peavey products, go to your local Peavey dealer or online at www.peavey.com

Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

CAUTION: Risk of electrical shock — DO NOT OPEN!

CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel.

WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this appliance, read the operating guide for further warnings.

Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” sin aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como para constituir riesgo de descarga eléctrica.

Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la operación y mantenimiento en la información que viene con el producto.

PRECAUCION: Riesgo de descarga eléctrica ¡NO ABRIR!

PRECAUCION: Para disminuír el riesgo de descarga eléctrica, no abra la cubierta. No hay piezas útiles dentro. Deje todo mantenimiento en manos del personal técnico cualificado.

ADVERTENCIA: Para evitar descargas eléctricas o peligro de incendio, no deje expuesto a la lluvia o humedad este aparato Antes de usar este aparato, Iea más advertencias en la guía de operación.

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur la présence d’une tension dangereuse pouvant être d’amplitude suffisante pour constituer un risque de choc électrique.

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes instructions concernant l’utilisation et l’entretien de l’appareil dans le paragraphe signalé.

ATTENTION: Risques de choc électrique — NE PAS OUVRIR!

ATTENTION: Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à l’intérieur aucune pièce pouvant être reparée par l’utilisateur. Confiez I’entretien et la réparation de l’appareil à un réparateur Peavey agréé.

AVERTISSEMENT: Afin de prévenir les risques de décharge électrique ou de feu, n’exposez pas cet appareil à la pluie ou à l’humidité. Avant d’utiliser cet appareil, lisez attentivement les avertissements supplémentaires de ce manuel.

Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses warnen, die von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können.

Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die Handhabung und Wartung des Produkts betreffen.

VORSICHT: Risiko — Elektrischer Schlag! Nicht öffnen!

VORSICHT: Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden sich keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von qualifiziertem Fachpersonal durchführen lassen.

ACHTUNG: Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: When using electrical products, basic cautions should always be followed, including the following:

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a dry cloth.

7.Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit from the apparatus.

11.Note for UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug‚ proceed as follows:

a)The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E‚ the earth symbol‚ colored green or colored green and yellow.

b)The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black.

c)The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red.

12.Only use attachments/accessories provided by the manufacturer.

13.Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When

a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

14.Unplug this apparatus during lightning storms or when unused for long periods of time.

15.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

16.Never break off the ground pin. Write for our free booklet “Shock Hazard and Grounding.” Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.

17.If this product is to be mounted in an equipment rack, rear support should be provided.

18.Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Government’s Occupational and Health Administration (OSHA) has specified the following permissible noise level exposures:

Duration Per Day In Hours

Sound Level dBA, Slow Response

8

90

6

92

4

95

3

97

2

100

1 12

102

1

105

12

110

14 or less

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or protectors to the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, if exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

PV®6Compact Mixer

Description

Congratulations on purchasing the Peavey PV6 needs while only occupying a small space. This is

Please read this guide carefully to ensure your

Features

XLR Mic inputs on all four channels

Two Stereo channels with 14" inputs

Three-band EQ on mono channels

Two-band EQ on stereo channels

Clip LEDs that thoroughly monitor

48V phantom power switch

Effects send on every channel with

Zero latency record monitoring

Control room out with level control

Contour control switch

80 Hz low cut switch

ENGLISH

quality mixing console designed to meet diverse performances or home recording environments.

of your equipment.

4

F R O N T P A N E L

1

 

 

8

 

 

9

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

2

12

3

13

4 14

5 15

6

16

7

 

17

 

18

 

 

19

 

 

 

 

 

 

 

 

 

 

control (shelving type: ±15 dB) that varies the level of the high frequency range.

(2)

control (shelving type: ±15 dB) that varies the mid frequency range.

(3)

control (shelving type: ±15 dB) that varies the level of the low frequency range.

Excessive low frequency boost causes greater power consumption and increases the possibility of speaker damage.

(4)

the level of the channel signal added to the effects mix. The effects send signal is taken after the channel

(7) so that adjustments made to the level control will also affect the send level.

controls the placement of the signal in the stereo field. When rotated completely counterclockwise‚ the only on the left channel; when rotated completely clockwise‚ only in the right channel.

(6)

normally indicates that the channel signal level is nearing the overload point. The clip indicator circuit signal at many points in the channel to ensure that it catches all instances of clipping. It illuminates at warns that the gain or EQ boost should be reduced. When it light,s roughly 3 dB of headroom

5

Level (7)

This is the channel output level control. The optimum setting is the 0 (unity gain) position.

Gain (8)

This control establishes the nominal operating level for the channel. The input gain can be adjusted over a wide range to compensate for soft voices or very loud drums. To maximize the signal-to-noise ratio, the gain should be set to the proper level with the channel level control (7) set to 0. If the clip LED comes on and remains lit, try reducing the gain.

Power LED (9)

This LED indicates that AC power is supplied to the unit‚ the power switch is on and the unit is functioning properly.

Headphone Level (10)

This knob sets the headphone and control room output level. To avoid damage to your hearing‚ make sure to turn the dial fully counterclockwise before using headphones. Slowly turn the knob clockwise until a comfortable listening level is set. Normally, the signal in the headphones is the Left/Right signal. If the Tape to Control Room (14) is engaged‚ the tape signal is also included.

LED Meters (11)

Two four-segment LED arrays are provided to monitor the levels of the main Left/Right outputs. These meters range from -21 dB to +19 dB. A reading of 0 db on the meter corresponds to +4 dBu at the outputs.

Phantom Power LED (12)

This LED lights when the Phantom Power Switch (13) has been engaged.

Phantom Power Switch (13)

Applies +48 VDC Voltage to the input XLR connectors to power microphones requiring phantom power.

If phantom power is used, do not connect unbalanced dynamic microphones or other devices to the XLR inputs that cannot handle this Voltage. The Phantom Power LED (12) indicates when phantom power is on.

Tape To Control Room (14)

Depressing this switch adds the tape return to the Control Room and Headphone Outputs (24) for zero latency monitoring.

Tape to Mix (15)

Depressing this switch routes the signal from the Tape Inputs to the Main Outputs (27).

Master Level Fader (16)

The Master Fader controls the level sent to the main Left/Right outputs. Best results are obtained when this control is set near the 0 point.

Contour Switch (17)

Engaging this switch enhances the signal by adding both bass and treble frequencies. This is especially effective at lower volumes or for tape/CD playback.

80 Hz Low Cut (18)

The Low Cut filter has a corner frequency of 80 Hz. When engaged‚ it can improve clarity by removing low frequencies that can make a mix sound muddy. This feature is especially useful when playing outside on a windy day or on a hollow‚ noisy stage. These kinds of ambient noises can rob your sound system of power. Engaging this switch removes those frequencies from the system and restores power to where it’s needed.

EFX/Return (19)

The EFX/Return Level Control adjusts the level sent to the Left/Right main bus from the return inputs.

6

R E A R P A N E L

28

 

27

20

 

 

21

 

 

22

 

 

23

25

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

30

 

31

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mic (XLR) Inputs (20)

XLR balanced inputs optimized for a microphone or other low impedance source. Pin 2 is the positive input. Because of the wide range of gain adjustment, signal levels up to +14 dBu can be accommodated.

Line (14") Inputs (21)

14” balanced (TRS) 10 k Ohm impedance input. The tip is the positive input and should be used for unbalanced inputs. It has 20 dB less gain than the XLR input and does not have phantom power available. The Mic and Line inputs should not be used simultaneously.

Gain (Channels 1 & 2) (22)

This control establishes the nominal operating level for the channel. The input gain can be adjusted over a wide range to compensate for soft voices or very loud drums. To maximize the signal-to-noise ratio, the gain should be set to the proper level with the channel level control (7) set to 0. If the Clip LED comes on and remains lit, try reducing the gain.

Stereo Inputs (23)

Channels 3 and 4 feature stereo inputs via 14” inputs and mono XLR inputs. When the 14" line inputs are in use‚ the XLR mic input is muted to prevent unwanted noise.

7

Control Room Outputs (24)

The Control Room Outputs feature two 14" TRS Z-balanced jacks. These outputs can be used with Tip‚ Ring Sleeve (TRS) balanced or Tip Sleeve (TS) unbalanced connectors. The Control Room Output Level is adjusted with the Headphone Level Control (10).

EFX Send (25)

The EFX Send features a 14" TRS Z-balanced jack in the master section. These outputs can be used with Tip‚ Ring Sleeve (TRS) balanced or Tip Sleeve (TS) unbalanced connectors. The EFX mix is determined by the amount of signal being sent to the EFX bus in each channel.

Headphone Output (26)

The Headphone Output is a 14" TRS (tip = left; ring = right; sleeve = ground). The signal sent to this output is normally the Left/Right mix. When the Tape to Control Room switch is engaged‚ the tape input signal is added to the Left/Right mix and can be monitored in the headphones.

Left/Right Outputs (27)

The Left/Right Outputs feature two 14" TRS Z-balanced jacks. These outputs can be used with Tip‚ Ring, Sleeve (TRS) balanced or Tip, Sleeve (TS) unbalanced connectors.

EFX Return (28)

The EFX Return inputs (Left/Mono‚ Right) feature two 14" TRS Z-balanced jacks. These outputs can be used with Tip‚ Ring, Sleeve (TRS) balanced or Tip, Sleeve (TS) unbalanced connectors. The EFX Return is controlled via the EFX/Return Level Control (19).

Power Adapter Input (29)

Use to connect the included power supply. Be sure the power supply is connected to the PV®6 before connecting to a power source. Use 16 VAC 1 A adapter only.

Power Switch (30)

Depressing the power switch applies power to the unit.

Tape In/Out (32 & 31)

The tape input jacks are designed to accommodate tape‚ CD or computer sound card output levels. The out level is +4 dBu for connection to a recorder or sound card input. The tape inputs can be used as an additional stereo input by engaging the Tape to Main Mix switch (15). The tape input can also be used to monitor the recorder/sound card output without the risk of feedback.

8

 

 

+48V

 

 

 

GLOBAL

 

 

 

PHANTOM

 

 

 

POWER

 

 

XLR

GAIN

LEVEL

 

 

1

2

EQ

 

+

 

 

 

 

4

3

-

 

 

 

 

LO

MID HI

 

 

LINE

 

 

 

MONO INPUT

 

 

+48V

 

 

 

 

GLOBAL

 

 

 

 

PHANTOM

 

 

 

 

POWER

 

 

 

XLR

GAIN

 

 

 

 

 

 

1

2

+

 

 

 

 

 

 

4

3

-

 

 

 

 

 

 

 

 

 

9

 

LEFT/MONO

+

EQ

 

 

 

 

 

 

 

 

 

-

 

 

 

 

LO

HI

 

 

 

-

EQ

 

 

 

 

 

 

 

+

 

 

 

RIGHT

LO

HI

STEREO INPUT

TAPE INPUT

LEFT/MONO

EFX RETURN

RIGHT

EFX

LEFT RIGHT

 

 

 

 

CLIP

 

 

 

 

 

PAN

 

 

 

 

 

EFX

 

 

 

 

 

 

 

 

 

LED METER

PV

 

TAPE OUTPUT

 

 

 

 

 

 

 

®

 

 

 

 

MAIN OUTPUTS

6

CLIP

 

 

 

Block

 

 

 

 

 

 

LO

HI

LEFT

 

HI PASS

 

CONTOUR

 

 

 

LO

HI

 

 

 

 

 

 

 

HI PASS

 

CONTOUR

 

Diagram

 

 

 

 

RIGHT

BALANCE

 

 

 

 

EFX

 

 

 

 

 

TAPE -L/R SELECT

CONTROL ROOM

 

 

 

 

 

 

 

LEFT

HEADPHONES

 

 

 

 

TAPE TO MIX

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT

 

 

 

TAPE TO

 

 

 

 

 

CONTROL ROOM

 

 

 

 

 

 

EFX SEND

 

 

PV® 6 Compact Console

SPECIFICATIONS

Inputs

Function

Input Z

Input Gain

 

Input Levels

 

Bal/Unbal

Connector

 

(ohms min)

Setting

Min**

Nominal*

Max

 

 

 

 

 

 

 

 

 

 

Microphone (150

2.2k

Max Gain

-83 dBu

-56 dBu

-38 dBu

Bal

XLR Pin 1 Gnd Pin

ohms)

 

(60 dB)

 

 

 

 

2 (+)‚ Pin 3 (-1)

 

 

Min Gain

-31 dBu

-5 dBu

+13 dBu

 

 

 

 

(9 dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

Line (10k ohms)

10k

Max Gain

-63 dBu

-36 dBu

-18 dBu

Bal

14" TRS; Tip (+)‚

 

 

(40 dB)

 

 

 

 

Ring (-)‚ Sleeve

 

 

 

 

 

 

 

Ground

 

 

Min Gain

-12 dBu

+14 dBu

+32 dBu

 

 

 

 

(-10 dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

Stereo Line Input

10k

Max Gain

-26 dBu

+4 dBu

+22 dBu

Unbal

14" TRS; Tip (+)‚

 

 

(30 dB)

 

 

 

 

Sleeve Ground

 

 

 

 

 

 

 

 

Aux Returns

10k

N/A

-17 dBu

+4 dBu

+22 dBu

Unbal

14" TRS; Tip (+)‚

 

 

(0 dB)

 

 

 

 

Sleeve Ground

 

 

 

 

 

 

 

 

Tape

10k

N/A

-17 dBu

-10 dBV

+12 dBu

Unbal

RCA Phone

 

 

(10 dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

0 dBu = 0.775 V (RMS)

 

 

 

 

 

 

**Min Input Level (sensitivity) is the smallest signal that will produce nominal output (+4 dBu) with channel and master faders set for maximum gain.

*Nominal settings are defined as all controls set at 0 dB (or 50% rotation for rotary pots) except the gain adjustment pot which is as specified.

Outputs

Function

Min Load Z

 

Output Level

Bal/Unbal

Connector

 

(ohms)

 

Nominal

 

Max

 

 

 

 

 

 

 

 

 

 

Main Left/Right

600

 

+4 dBu

 

+22 dBu

Bal

14" TRS: Tip (+); Ring (-); Sleeve

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

 

Effects Sends

600

 

+4 dBu

 

+22 dBu

Bal

14" TRS; Tip (+)‚ Sleeve Ground

 

 

 

 

 

 

 

 

Headphone

8

 

+4 dBu (no load)

 

+22 dBu

Unbal

14" TRS; Tip Left‚ Ring Right‚ Sleeve

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

 

Tape

2.2 k

 

+4 dBu

 

+22 dBu

Unbal

RCA Phone

 

 

 

 

 

 

 

 

0 dBu = 0.775 V (RMS)

 

 

 

 

 

Gain

 

 

 

 

 

 

 

Mic Input Gain Adjustment Range:

 

10 dB to 60 dB

 

 

Mic Input to Left/Right Balance Output

87 dB (max gain)

 

 

Line Input Gain Adjustment Range:

 

-10 dB to 40 dB

 

 

Line Input to Left/Right Balance Output

67 dB (max gain)

 

 

Stereo Line Input Gain Adjustment Range:

10 dB

 

 

Stereo Line Input to Left/Right Output

28 dB (max gain)

 

 

Aux Return to Left/Right Balance Output

21 dB (max gain)

 

 

10

Loading...
+ 22 hidden pages