• 40 WATTS OUTPUT POWER
• 2:1 WIDE INPUT VOLTAGE RANGE
• DESIGN MEET SAFETY STANDARD
• SIX-SIDED CONTINUOUS SHIELD
• HIGH EFFICIENCY UP TO 90%
• STANDARD 3” X 2.6” X 0.4” PACKAGE
• FIXED SWITCHING FREQUENCY
Patent No. 460344
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25ºC otherwise noted
OUTPUT SPECIFICATIONS
Output power
Voltage accuracy Full load and nominal Vin
Voltage adjustability ± 10%
Minimum load (Note 1)
Line regulation LL to HL at Full Load
Load regulation 10% to 100% FL
Cross regulation (Note 2)
Ripple and noise 20MHz bandwidth 1%/p-p of Vout max
Temperature coefficient
Transient response recovery time 25% load step change 500uS
Over voltage protection
Zener diode clamp
Short circuit protection Hiccup, automatics recovery
INPUT SPECIFICATIONS
Input voltage range
Input filter Pi type
Input surge voltage
100mS max
Input reflected ripple (Note 3) Nomi nal Vin and full load 40mAp-p
Start up time Nominal Vin and constant resistor load 25mS typ
Remote ON/OFF
(Note 4)
Remote off input current
Single & Dual
Triple 3.3V/5V
Auxiliary
FDC40-XXD3305 3.3V output
Others
3.3V output
5V output
12V output
15V output
12V nominal input
24V nominal input
48V nominal input
12V input
24V input
48V input
DC-DC ON
DC-DC OFF
Nominal input
Single
Dual
Triple 3.3V/5V
Auxiliary
Single
Dual
Triple 3.3V/5V
Auxiliary
Dual
Triple 3.3V/5V
Auxiliary
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
I0.02% / ºC, max
The FDC40 series offer 40 Watts of output power from a 3 x 2.6 x 0.4 inch package.
The FDC40 series have 2:1 wide input voltage of 9-18, 18-36 and 36-75VDC. The FDC40
features 1600VDC of isolation, short-circuit and over-voltage prot ection, as well as six
sided shielding. Designed meets the safety of EN60950 and UL1950. All models are
particularly suited to telecommunications, i ndust ri al, mobil e tel ecom and test equipment
applications.
GENERAL SPECIFICATIO NS
40 Watts max
± 2%
± 2%
± 5%
20% min
10% of FL
± 0.5%
± 1%
± 2%
± 5%
± 0.5%
± 1%
± 2%
± 5%
± 1%
± 1%
± 5%
Efficiency See table
Isolation voltage 1600VDC, min
Isolation resistance
Isolation capacitance 500Pf, max
Switching frequency 185KHz, typ
Design meet safety standard UL1950, EN60950
Case material Nickel-coated coppe
Base material Non-conductive black FR4
Potting material Epoxy (UL94-V0)
Dimensions
Weight 125g (4.4oz)
MTBF (Note 5) 1.590 x 106 hrs
3.00 X 2.60 X 0.40 Inch
(70.2 X 66.0 X 10.2 mm)
ENVIRONMENTAL SPECIFICATIONS
Operating temperature range -40ºC ~ +85ºC (with derating)
3.9V
6.2V
15V
18V
9 – 18VDC
18 – 36VDC
36 – 75VDC
36VDC
50VDC
100VDC
30mA
Maximum case temperature +100ºC
Storage temperature range -55ºC ~ +105ºC
Thermal impedance Nature convection 5.7ºC/watt
Thermal shock MIL-STD-810D
Vibration 10~55Hz, 2G, 30minitues along X,Y and Z
Relative humidity 5% to 95% RH
EMC CHARACTERISTICS
Conducted emissions EN55022 Level A
Radiated emissions EN55022 Level A
Conducted immunity EN61000-4-6 Perf. Criteria2
Radiated immunity EN61000-4-3 Perf. Criteria2
Surge EN61000-4-5 Perf. Criteria2
Fast transient EN61000-4-4 Perf. Criteria2
ESD EN61000-4-2 Perf. Criteria2
109ohms, min
Model
Number
FDC40-12S33 9 – 18 VDC 3.3 VDC 10000mA
FDC40-12S05 9 – 18 VDC 5 VDC 8000mA
FDC40-12S12 9 – 18 VDC 12 VDC 3400mA 4100mA 87 2400uF
FDC40-12S15 9 – 18 VDC 15 V DC 2700mA 4100mA 87 1550uF
FDC40-12D05 9 – 18 VDC ± 5 VDC +7000 / -1000mA 4330mA 81 12000 / 1700uF
FDC40-12D12 9 – 18 VDC ± 12 VDC ± 1800mA 4550mA 83 ± 1200uF
FDC40-12D15 9 – 18 VDC ± 15 VDC ± 1400mA 4430mA 83 ± 750uF
FDC40-12D3305 9 – 18 VDC 3.3 / 5VDC 4000 / 4000mA 3730mA 78 10300 / 6800uF
FDC40-12T0512 9 – 18 VDC 5 / ± 12 VDC 4000 / ± 850mA 4490mA 79 6800 / ± 590uF
FDC40-12T0515 9 – 18 VDC 5 / ± 15 VDC 4000 / ± 680mA 4430mA 80 6800 / ± 380uF
FDC40-24S33 18 – 36 VDC 3.3 VDC 10000mA 1720mA 84 25800uF
FDC40-24S05 18 – 36 VDC 5 VDC 8000mA 2010mA 87 13600uF
FDC40-24S12 18 – 36 VDC 12 V DC 3400mA 1980mA 90 2400uF
FDC40-24S15 18 – 36 VDC 15 VDC 2700mA 2000mA 88 1550uF
FDC40-24D05 18 – 36 VDC ± 5 VDC +7000 / -1000mA 2130mA 82 12000 / 1700uF
FDC40-24D12 18 – 36 VDC ± 12 VDC ± 1800mA 2170mA 87 ± 1200uF
FDC40-24D15 18 – 36 VDC ± 15 VDC ± 1400mA 2140mA 86 ± 750uF
FDC40-24D3305 18 – 36 VDC 3.3 / 5VDC 4000 / 4000mA 1840mA 79 10300 / 6800uF
FDC40-24T0512 18 – 36 VDC 5 / ± 12 VDC 4000 / ± 850mA 2180mA 81 6800 / ± 590uF
FDC40-24T0515 18 – 36 VDC 5 / ± 15 VDC 4000 / ± 680mA 2160mA 82 6800 / ± 380uF
FDC40-48S33 36 – 75 VDC 3.3 VDC 10000mA 850mA 85 25800uF
FDC40-48S05 36 – 75 VDC 5 VDC 8000mA 980mA 89 13600uF
FDC40-48S12 36 – 75 VDC 12 V DC 3400mA 1000mA 89 2400uF
FDC40-48S15 36 – 75 VDC 15 VDC 2700mA 1000mA 88 1550uF
FDC40-48D05 36 – 75 VDC ± 5 VDC +7000 / -1000mA 1060mA 84 12000 / 1700uF
FDC40-48D12 36 – 75 VDC ± 12 VDC ± 1800mA 1100mA 86 ± 1200uF
FDC40-48D15 36 – 75 VDC ± 15 VDC ± 1400mA 1100mA 86 ± 750uF
FDC40-48D3305 36 – 75 VDC 3.3 / 5VDC 4000 / 4000mA 910mA 80 10300 / 6800uF
FDC40-48T0512 36 – 75 VDC 5 / ± 12 VDC 4000 / ± 850mA 1060mA 83 6800 / ± 590uF
FDC40-48T0515 36 – 75 VDC 5 / ± 15 VDC 4000 / ± 680mA 1060mA 83 6800 / ± 380uF
Note
1. The FDC40 series required a minimum 10% loading on the output to maintain
specified regulation. Operation under no-load condition will not damage these
devices, however they may not meet all listed specification.
2. Cross regulation:
Dual output—Asymmetrical load 25% to 100% full load
Triple output – 3.3V / 5V 100% load and one of auxiliary 100% load, other
auxiliary load change from 25% to 100% load
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. The ON-OFF control pi n voltage is referenc e to negative input.
5. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC.
(Ground fixed and controlled environment)
6. Maximum value at nominal input voltage and full load
7. Typical value at nominal input voltage and full load
8. Test by minimum Vin and constant resistor load.
Input
Range
Output
Voltage
Output
Current
Input
Current
3530mA
4170mA
FDC40-48S05
Efficiency VS Input Voltage
90
89
88
87
86
85
84
83
EFFICIENCY (%)
82
81
80
INPUT VOLTAGE (V)
Eff
(6)
(%)
83 25800uF
84 13600uF
45 55 65 7536 40
Capacitor
Load max
6050 70
FDC40-48S05 Derating Curve
100
75
Nature convection
50
25
OUTPUT POWER (%)
0
AMBIENT TEM PERATUR E (ºC)
50 60 70 80 90
100 -40 -25 0 -10
FDC40-48S05
Efficiency VS Output load
90
89
88
86
84
82
80
70
EFFICIENCY (%)
60
50
45
1
0.5
2 3 4 5 7
OUTPUT LOAD (A)
6 8