PATLITE CLA User Manual

CL
0.24kg±10%
0.4kg±10%
0.57kg±10%
CLA3S
CLA6S
CLA9S
21.6W
7.2W
24V DC ±10%
24V DC (
Polarized
28.8W
IP66/67(IEC 60529)/69K (DIN 40050 part9)
(Cable connector ends not included)
CLA3S CLA6S CLA9S CLA12S CLA15S
CLA3S CLA6S CLA9S CLA12S CLA15S
○ ○ ○ ○ ○
○ × × × ×
○ ○ ○ ○ ○
L95100056
B
L0099
LED Light Bar
TM
INSTRUCTION MANUAL
Model : CLA
Thank you for purchasing the PATLEDs LED Work Light for your application. Prior to installation, please read through this manual for proper installation and precautionary steps. In addition, please store this manual for future reference when performing maintenance, repairs or inspections. If you have any questions regarding this product, please contact our PATLITE Sales Representative.
Safety Precautions
In order to prevent any damage to the user and other personnel or to assets, note the following:
The following symbols classifies the following precautions into two catagories and
explains the level of harm inflicted when caution is disregarded while using this product.
WARNING
CAUTION
The following symbols indicate and explains the nature of the information to be observed.
This symbol indicates "Prohibited", which should not be carried out by all means.
This symbol indicates "Enforced", which should be observed and carried out by all means.
1. For safe application, observe the following:
WARNING
[ Prohibited ]
[ Enforced ]
CAUTION
[Prohibited]
[Enforced]
Displays the warning "Failure to follow warning may lead to death or severe injury".
Displays the warning "Failure to follow caution may lead from light to medium injury or maylead to property loss or injury to others".
Do not modify or disassemble the product. Failure to comply may
result in electric shock or fire.
After installing this product, be careful not to use this product to
climb onto a machine, or to get anything snagged onto this product while it is mounted on equipment, etc. Failure to comply may result in falling off the machinery or product damage may occur.
Be sure to disconnect the power when wiring, mounting,
exchanging, or repairing the product. Failure to comply may result in damage of the internal circuitry and the danger of electric shock due to short-circuiting.
Request the installation and wiring to be accompanied by a
professional contractor. Failure to comply may result in electric shock, fire, or falling from high places.
When this product is used for security purposes, it should be
inspected daily, and to be used in conjunction with other security products, in case a malfunction should occur.
Verify the installation location is a firm location which can handle
the weight of the product and has no adverse vibrations. If installed in a place where vibration is frequent and/or exceeds the specifications, damage to the product may occur.
In order to avoid danger to the eyes, do not stare into the beam,
do not view directly into the optical instrument, and don't turn the beam towards someone's eyes. The LED beam is hazardous to the eyes.
Do not loosen any screws. It will have an adverse effect on the
protection rating.
Verify that the specified operating voltage is not exceeded.
Connect an external fuse for protection from the power supply.
The product can be protected by short-circuiting due to mis-wiring and overcurrents or overvoltages which can damage it.
Avoid installation in the following locations:
In direct sunlight, near space heaters or places where high
temperatures are present.
In locations where iron powder, oil, chemical or explosive gasses, etc., are present.
2. Model Number Configuration
CLA□□-24H- CL- 30
Light Unit Length
3S : 300 mm 6S : 600 mm 9S : 900 mm 12S : 1200 mm 15S : 1500 mm
3. Part Names and Dimensions
Outer Dimensions (mm)
34
30
3.
Bracket (Option)
19.5
22.5
[Dimension Chart]
Model Name
CLA3S CLA6S CLA9S CLA12S CLA15S
4. Installation
WARNING
Do not modify or disassemble the product. Failure to comply may result in
[Prohibited]
[Enforced]
[Enforced]
electric shock or fire.
After installing this product, be careful not to use this product to climb onto a
machine, or to get anything snagged onto this product while it is mounted on equipment, etc. Failure to comply may result in falling off the machinery or product damage may occur.
Be sure to turn off the power to prevent from electric shock before performing
any maintenance.
Verify the installation location is a firm location which can handle the weight of
the product and has no adverse vibrations. If installed in a place where vibration is frequent and/or exceeds the specifications, damage to the product may occur.
CAUTION
Be careful to properly install the product to prevent it from falling, etc.
This product is designed for indoor use only (Not for outdoor Use).
The bracket is made of polycarbonate resin.
Damage may occur if solvents such as screw locking agents or such adhesives
are used.
Rated Voltage 24 : 24V DC
Color
CL : Warm White
Dim. A Dim. B Dim. D Dim. E
3-Φ4.2
Case
(Beveled)
Dim. A Dim. B
Maximum
324 624
924 1224 1524
Corresponding Bracket Table
Model Name SZ-310AS SZ-310ASB SZ-310ARM
CLA3S CLA6S CLA9S CLA12S CLA15S
Lighting
300 600
900 1200 1500
25
Cable length:
Dim. D
Attachement Pitch
274 574
874 1174 1474
Cable Length
30 : 3
Max. Bending Dia.:24mm
Wiring Example
Cable Exit Hole
170 (UL508
Conformity
Φ4.9
500 or 3000
from wire exit
Dim. E
290 390 490
Accessory
-
-
(30)
)
5
10.3
Brackets
2
2 *4 *4 *4
Installation Location
After making mounting holes on a flat and sturdy surface, attach the bracket.
Referring to the drawing below, install the bracket with M4 flush-mount screws (recommendation : use two screws per bracket).
For the 9S, 12S, and 15S, please orientate the four SZ-310AR brackets
included with the product.
Dim. D
25
Recommended Bolt Torque 1.0 N-m
Recommended Screw Dimensions
M4
90°
than φ8
No more
6. Maintenance and Inspection
Refer to the table below before requesting repairs. If the product does not work after referring to the table below, please request for
repair. In addition, if there are any questions concerning this product, feel free to contact your PATLITE Sales Representative.
Problem
Where to Check
What to do
• Verify the voltage has been connected.
Does not
light up
Is the power
properly
supplied?
• Verify the proper polarity.(White+, Brown:-
• Verify the proper voltage is supplied (24V DC).
• Check whether the external fuse has been blown-out.
7. Specifications
CAUTION
After the bracket is mounted to a sturdy surface, snap the main unit into place.
  A slide lock is possible when attaching with the recommended installation pitch.   Installation is possible for other mounting pitches.
The screw cap can be removed.
Lock Tab
Sliding Direction
Screw Cap
6
CAUTION
「Enforced」
The screw cap, may fall out during high-pressure washing, etc. Please remove it in advance to prevent it from falling out before a problem occurs.
(Example: Contamination in a food-processing line)
The product slides in the direction indicated when mounting outside the recommended pitch.
5. Wiring and Proper Use
WARNING
Be sure to disconnect the power when wiring, mounting, exchanging, or repairing
[Enforced]
[Enforced]
Wiring
1. The internal protection for the product requres a
2A fuse rating. For lighting installation, use a fuse with a rating of 2A or higher.
2.
Use a UL authenticated Class 2 power supply unit to connect power to this product. The power supply unit is constant voltage type. 3.UL508A conformity for LED lighting installation designs In case the supplying power from power unit is beyond 150V, please ground the primary power unit side to earth ground.
Operation
Referring to section "Wiring" above, by applying DC 24V, the LED will turn on.
LED'swill start to light-up when 0.1mA or more is applied.
the product. Failure to comply may result in damage of the internal circuitry and the danger of electric shock due to short-circuiting.
CAUTION
Check that the proper voltage is connected before applying power.
Do not pull on the cable, or try to push it inside the unit. Possible cause of
failure may occur. In addition, allow a margin of slack for the wire and cable to prevent stress.
Use a constant-voltage regulated power supply. Possible cause of failure may
occur with the use of a constant current power supply.
Connect an external fuse for protection from the power supply. The product can
be protected by short-circuiting due to mis-wiring and overcurrents or overvoltages which can damage it.
The Protection Rating does not include the cable ends. If the ends of the cable are in contact with water or exposed to dew or condensation, refer to the indications below to dress the cable ends for water resistance.
Connect the wire ends in a location which will not expose the ends to water.
Use Fillers, such as silicon, etc., to seal the cable ends. Refer to the circled part of the figure below for the sections requiring protection from water intrusion.
Cable Type】AWG22/2 Wire
(External)
Recommended Fuse
Fuse
Voltage
Current
Brown
White
125
2A or more
Power Supply
DC24V
● Specifications and dimensions may change without prior notice for improvements,
etc.
● Due to the characteristics of the LED, color temperature, brightness and hue will
differ for evey LED and every product.
● Since all IP examinations are done according to specified conditions and regulated
time, the protection rating is not guaranteed for an extended period of time.
Model Name
Light Unit Length
Color Code
Luminous Color
Color Temperature(typ.)
Illuminance
(at 24V DC)
Operating Voltage Range
Rated Power Consumption
(at 24V DC)
Operating Voltage Range
Rated Power Consumption
PATLITE and the PATLITE logo is a trademark, or registered
trademark of the PATLITE Corporation of Japan and and each country.
at 1.0m
Luminous Flux
(at 24V DC)
Rated Voltage
Rated Current
Consumption
Operating Temperature
Range
Main Body Material
Protection Rating
Mounting Direction
Insulation Resistance
Withstanding Voltage
Vibration Resistance
Mass
Model Name
Light Unit Length
Color Code
Luminous Color
Color Temperature(typ.)
Illuminance
at 1.0m
Luminous Flux (at 24V DC)
Rated Voltage
Rated Current
Consumption
Operating Temperature
Range
Main Body Material
Protection Rating
Mounting Direction
Insulation Resistance
Withstanding Voltage
Vibration Resistance
Mass
300 mm 600 mm 900 mm
Warm White
150 lx
500 lm
300mA±10% 600mA±10%
-40℃ to +50℃ (RH 90% or less, no condensation) Polycarbonate Resin (Waterproof Packing: Silicon)
5MΩ or more with a 500V DC Megohmmeter
2
19.6 m/s (30Hz, Back and Forth:2h・Right to Left:2h・Up and Down:2h)
CLA12S CLA15S
1200 mm 1500 mm
490 lx
1910 lm
1,200mA±10% 1,500mA±10%
-40℃ to +50℃ (RH 90% or less, no condensation) Polycarbonate Resin (Waterproof Packing: Silicon)
5MΩ or more with a 500V DC Megohmmeter
2
19.6 m/s (30Hz, Back and Forth:2h・Right to Left:2h・Up and Down:2h)
0.73kg±10% 0.88kg±10%
2700K
290 lx
960 lm
14.4W
Indoor Use Any Direction
500V AC for 1 minute
CL
Warm White
2700K
Indoor Use Any Direction
500V AC for 1 minute
400 lx
1360 lm
900mA±10%
560 lx
2395 lm
36.0W
L95100056
‘13.11
GCD
B
Loading...