PANJIT KBU8D, KBU8J, KBU8K, KBU8B, KBU8A Datasheet

...
0 (0)
PAGE . 1
Approve Sheet
Part Number: KBU8A~KBU8K
FEA TURES
• Plastic material has Underwriters Laboratory
Flammability Classification 94V-O
• Ideal for printed circuit board
• Reliable low cost construction utilizing molded plastic technique
• High temperature soldering guaranteed:
260°C/10 seconds/.375"(9.5mm) lead length at 5 lbs. (2.3kg) tension
KBU8A~KBU8K
SILICON SINGLE-PHASE BRIDGE RECTIFIER
VOL TAGE - 50 to 800 Volts CURRENT - 8.0 Amperes
Recongnized File # E111753
MECHANICAL DATA
Case: Reliable low cost construction utilizing
molded plastic technique
Terminals: Leads solderable per MIL-STD-202,
Method 208
Mounting position: Any
Mounting torque: 5 in. lb. Max.
Weight: 0.3 ounce, 8.0 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25°Cambient temperature unless otherwise specified. Resistive or inductive load, 60Hz.
For Capacitive load derate current by 20%.
DATA SHEET
KBU
Unit: inch ( mm )
.224
(
5.7
)
.295
(
7.5
)
1.0(25.4) MIN.
R .075
(
1.9
)(
2x
)
.052
(
1.3
)
.047
(
1.2
)
.280
(
7.1
)
.268
(
6.8
)
.138
(
3.5
)
.220
(
5.6
)
.181
(
4.6
)
.780
(
19.8
)
.740
(
18.8
)
.701
(
17.8
)
.661
(
16.8
)
.933
(
23.7
)
.894
(
22.7
)
~~
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Input Voltage
Maximum DC Blocking Voltage
Maximum Average Forward T
C
=100°C
Rectified Output Current atT
A
=40°C
I
2
t Rating for fusing ( t<8.3ms)
Peak Forward Surge Current single sine-wave superimposed on rated load
(JEDEC method)
Maximum Instantaneous Forward Voltage Drop per element at 8.0A
Maximum Reverse Leakage at rated T
A
=25°
CDc Blocking Voltage per element T
C
=100°C
Typical Thermal Resistance per leg(Note 2) RθJA
Typical Thermal Resistance per leg(Note 3) RθJC
Operating and Storage Temperature Range, T
J
,TSTG
V
V
V
A
A
2
sec
Apk
µA
°C / W
UNIT
°C
NOTES:
1. Recommended mounting position is to bolt down on heatsink with silicone thermal compound for maximum heat transfer with #6 screw.
2. Units Mounted in free air, no heatsink, P.C.B at 0.375"(9.5mm) lead length with 0.5 x 0.5"(12 x 12mm)copper pads.
3. Units Mounted on a 2.0 x 1.6" x 0.3" thick (5 x 4 x 0.8cm) AL plate.
µA
50
35
50
Vpk
8.0
8.0
166
200
1.0
10
1000
18.0
3.0
-55 to +150
°C / W
KBU8A
100
70
100
KBU8B
200
140
200
KBU8D
400
280
400
KBU8G
600
420
600
KBU8J
800
560
800
KBU8K
Loading...
+ 1 hidden pages