Caution: To Avoid Serious Injury
Important: Read the following warnings before beginning an installation. Failure to do so may result in possible death or serious injury.
DO Adhere to all National and Local Plumbing and Elec-
trical Safety Codes.
DO Turn “off” incoming electrical service switches
when servicing, installing, or repairing equipment.
DO Check that all flare fittings on the carbonation
tank(s) are tight. This check should be performed with a wrench to ensure a quality seal.
DO Inspect pressure on Regulators before starting up
equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges of
all equipment.
DO Handle CO
cylinders properly against abrasion.
DO Store CO
Manitowoc Beverage Equipment
2100 Future Drive Sellersburg, IN 47172-1868 Tel: 812.246.7000, 800.367.4233 Fax: 812.246.9922 www.manitowocbeverage.com
2 cylinders and gauges with care. Secure
2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a CO2 cylinder. Secure the cylinder(s)
DO NOT Connect the CO
DO NOT Store CO
DO NOT Release CO
DO NOT Touch Refrigeration lines inside units, some may
Notice: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained in accordance with Federal, State, and Local codes.
in an upright position with a chain.
container. Doing so will result in an explosion caus­ing possible death or injury. Best to connect the
2 cylinder(s) to a regulator(s).
CO
(51.7°C) near furnaces, radiator or sources of heat.
exceed temperatures of 200°F (93.3°C).
In accordance with our policy of continuous product development and improvement,
2 cylinder(s) directly to the product
2 cylinders in temperature above 125°F
2 gas from old cylinder.
this information is subject to change at any time without notice.
EI214299 Revision A (KAK) 15 May, 2001
Wall Channel Mounting Template
Figure 1
Equipment Installation Instructions
Introduction
The 2803/75 Wall Mount kit is designed to mount a Model 2803 or Model 75 Refrigeration Unit on a vertical wall. The kit includes lag screws for mounting on a frame wall. Mounting on a masonry wall requires anchors or toggle bolts which are not included with this kit.
Required tools
One (1) drill with 7/32" bit
1
One (1)
/2" socket wrench
One (1) 4 ft level
9
One (1)
/16" socket wrench
One (1) framing square
One (1) 8 ft measuring tape
Installing the wall mount shelf kit
1. Locate and mark three (3) wall studs at desired mounting
position.
2. Measure and mark location for top three (3) holes no closer
than 8" (20.3 cm) from the ceiling. Place a 4 ft level to
bridge the three (3) studs. Place a mark at each stud (re-
fer to figure 1).
3. Measure and mark the two (2) outer studs 15" (38.1 cm)
below the marks made in step 2. Using a framing square,
make a vertical mark at the center of each stud.
7
5. Drill ten (10) holes
/32" diameter by 1 3/4" deep (refer to
figure 1).
5
6. Attach channels to wall with
/16" x 2" lag screws. Use a
flat washer under the head of each screw.
5
7. From the rear, slip a
/16" x 3/4" carriage bolt through the square hole in each end of the channel and assemble the triangle shaped Brackets (refer to figure 2).
8. Assemble the Support Angles to the triangle shaped Brack­ets with carriage bolts, washers, and hex nuts (refer to figure 2).
Note: The rear Support Angle must be installed in the holes closest to the front holes.
9. Mount the refrigeration unit on the Wall Mount and se­cure with
3
/8" x 3/4" screws and washers. Position the unit so side that the service access panel maybe easily re­moved.
Installing the Wall Mount Shelf
Bracket
Channel
Carriage
Bolt
4. Using one of the channels as a template, align the top flange over the top row of marks. Verify the level and mark the hole positions for the lower flange. Repeat the process for the lower channel location.
Note: The lower channel is secured with only four (4) lag screws, two (2) at each end.
2
Support Angle
Flat Washer
Lock Nut
Figure 2
EI214299 Revision A (KAK) 15 May, 2001