OPTI-UPS CS730B, CS530B, CS385B User Manual

For stylish home and office
Series
CS385 / CS530B / CS730B / CS500B
CS385B / CS530B / CS730B
* Fully digitized microprocessor control * Energy saving (UPS sleep mode ) * 50/60Hz frequency auto sensing * Buzzer can be muted by pressing “ON/OFF” button * Single PCB with reliable design * Clear LED alarms * Cold start (DC power on)
Rear Panel
Model Name
CS385B
Breaker
Battery Backup
Bypass
CS530B / CS730B
Breaker
Bypass
Battery Backup
OUTPUT UPS Capacity No. of Sockets
Voltage (on battery*) Frequency (on battery) Transfer Time INPUT Voltage (single phase) Frequency PROTECTION Unit Input Overload Protection
Short Circuit Spike Protection BATTERY Type
Typical Recharge Time (to 90% of full capacity) Back-up Time
Protection
PHYSICAL Net Weight kg (lbs) Dimension WxDxH INTERFACE Dry Contact (option) USB (option) ALARM Battery Backup
Battery Low UPS Works at Full Load Overload ENVIRONMENT Ambient Operation
Audible Noise
* See VS1000C on page 6
PC with 15” LCD
CS385
CS530B
CS730B
* CS385B / CS530B / CS730B
* Short circuit and overload protection * Advanced battery management (ABM) * Automatic diagnostics & battery check * Surge protection of all outlets * EMI/RFI noise filter
NEMA 5-15 Only
Thailand,
CS 385B CS 730B
385VA 730VA
100V / 115V / 220V / 240V < +/- 5% AVR controlled by PWM
< 10 milliseconds, including detection time
220V / 230V / 240V, 170V~280 at line input
50 or 60 Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS Automatic shutdown if overload exceeds 105% of
nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds
Sealed, maintenance-free lead acid batteries with 3-5 years
8 - 12 minutes
Automatic self- test, Over discharge protection, short circuit
1.6 (3.52)
95 x 95 x 158 mm 95 x 138 x 158 mm
Sends battery low & power failure signals, and receives shutdown signal from computer
Detects power failure battery low, Schedules UPS ON / OFF, displays AC input / output power status
Short beeping sound every 4 seconds
(Buzzer can be muted by pressing main switch button)
Rapid beeping sound every seconds
Long continuous beeping sound every 4 second
3,500 meters max elevation, 0-95% humidity
(No-condensing water),0-40 deg C
CS 530B
530VA
NEMA 5-15R
UPS x 2, Bypass x 2
Simulated sine wave at
50 or 60Hz +/- 0.3 Hz
100V +/- 20%, 110V +/- 25%
UPS output cut off immediately
460 joules, 2ms
typical life time
6 hours
15 - 18 minutes
protection by fuse
2.6 (5.72)
Continuous beeping sound
<40dBA (1 meter form surface)
2.6 (5.72)
Standby UPS
UPS Series
Line Interactive
Series
On Line UPS
AVR Series
Surge Series
Series
Green Power