Omron CJ2H-CPU6-EIP, CJ2M-CPU3, CS1W-EIP21, CJ1W-EIP21 User Manual

0 (0)

Cat. No. W465-E1-05

SYSMAC CS and CJ Series

CS1W-EIP21 (100Base-TX)

CJ1W-EIP21 (100Base-TX)

CJ2H-CPU6@-EIP (100Base-TX)

CJ2M-CPU3@ (100Base-TX/10Base-T)

EtherNet/IP Units

OPERATION MANUAL

CS1W-EIP21 (100Base-TX)

CJ1W-EIP21 (100Base-TX)

CJ2H-CPU6@-EIP (100Base-TX)

CJ2M-CPU3@ (100Base-TX/10Base-T)

EtherNet/IP Units

Operation Manual

Revised February 2010

iv

Notice:

OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual.

The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property.

!DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Additionally, there may be severe property damage.

!WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Additionally, there may be severe property damage.

!Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage.

OMRON Product References

All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product.

The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense.

The abbreviation “PLC” means Programmable Controller. “PC” is used, however, in some Programming Device displays to mean Programmable Controller.

Visual Aids

The following headings appear in the left column of the manual to help you locate different types of information.

Note Indicates information of particular interest for efficient and convenient operation of the product.

1,2,3... 1. Indicates lists of one sort or another, such as procedures, checklists, etc.

Trademarks and Copyrights

EtherNet/IP is a registered trademark of the ODVA (Open DeviceNet Vendor Association).

Ethernet is a trademark of the Xerox Corporation.

Microsoft, Windows, Windows NT, Windows 2000, Windows XP, and Windows Vista are registered trademarks of the Microsoft Corporation.

Other names of systems or products that appear in this document are trademarks or registered trademarks of the respective company.

OMRON, 2007

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON.

No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.

v

vi

TABLE OF CONTENTS

PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxi

1

Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxii

2

General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxii

3

Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxii

4

Operating Environment Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxiv

5

Application Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxiv

6

Conformance to EC Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxvi

SECTION 1

 

Overview of EtherNet/IP . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1-1

EtherNet/IP Unit Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1-2

Devices Required for Constructing a Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1-3

Support Software Required to Construct a Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1-4

Communications Services Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

1-5

Network Configurator Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

SECTION 2

 

Unit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

2-1

EtherNet/IP Unit and Built-in EtherNet/IP Port Specifications . . . . . . . . . . . . . . . . . . . . . .

14

2-2

Nomenclature and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

2-3

Selecting the Network Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

SECTION 3

 

Installation and Initial Setup . . . . . . . . . . . . . . . . . . . . . . . . .

33

3-1

Overview of Initial Setup Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

34

3-2

Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

36

3-3

Mounting to a PLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

38

3-4

Network Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

41

3-5

Connecting to the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

44

3-6

Creating I/O Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

46

3-7

Setting the Local IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

50

3-8

TCP/IP and Link Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

52

3-9

Tag Data Link Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

57

3-10

Other Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61

3-11

Communications Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

65

vii

TABLE OF CONTENTS

SECTION 4

 

Memory Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

67

4-1 Overview of Memory Allocated to the EtherNet/IP Unit . . . . . . . . . . . . . . . . . . . . . . . . . . .

68

4-2

CIO Area Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

70

4-3

DM Area Allocations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

83

4-4

User Settings Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

85

4-5

Auxiliary Area Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

88

SECTION 5

 

Determining IP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . .

91

5-1

IP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

92

5-2 IP Addresses in FINS Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

94

5-3 Private and Global Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

106

SECTION 6

 

Tag Data Link Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . .

111

6-1 Overview of Tag Data Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

112

6-2 Setting Tag Data Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

121

6-3 Ladder Programming with Tag Data Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

183

SECTION 7

 

Message Communications Functions . . . . . . . . . . . . . . . . . .

187

7-1

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

188

7-2

FINS Message Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

190

7-3

Explicit Message Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

192

7-4

Message Communications Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

193

7-5 Message Communications Error Indications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

194

7-6

Message Communications Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

195

SECTION 8

 

FINS Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

197

8-1 Overview of FINS Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

198

8-2

FINS/UDP Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

200

8-3

FINS/TCP Method. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

202

8-4

Routing Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

207

8-5

Using FINS Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

211

8-6 Communicating between OMRON PLCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

220

8-7 Precautions on High Traffic in FINS Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

232

SECTION 9

 

Message Communications . . . . . . . . . . . . . . . . . . . . . . . . . . .

233

9-1

Sending Explicit Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

234

9-2

Receiving Explicit Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

248

viii

TABLE OF CONTENTS

SECTION 10

 

Communications Performance and Communications Load

261

10-1

Communications System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

262

10-2 Adjusting the Communications Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

268

10-3 I/O Response Time in Tag Data Links. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

283

10-4 Tag Data Link Performance for CJ2M Built-in EtherNet/IP Ports . . . . . . . . . . . . . . . . . . . .

291

10-5 Message Service Transmission Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

294

SECTION 11

 

FTP Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

301

11-1

Overview and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

302

11-2 FTP Server Function Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

303

11-3 Using the FTP Server Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

305

11-4 FTP Server Application Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

307

11-5

Using FTP Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

308

11-6

Checking FTP Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

314

11-7

Using File Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

315

11-8 FTP File Transfer Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

320

11-9 Host Computer Application Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

321

SECTION 12

 

Automatic Clock Adjustment Function . . . . . . . . . . . . . . . .

323

12-1

Automatic Clock Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

324

12-2 Using the Automatic Clock Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

325

12-3 Automatic Clock Adjustment Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

328

12-4 Automatic Clock Adjustment Error Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

328

SECTION 13

 

Maintenance and Unit Replacement . . . . . . . . . . . . . . . . . . .

331

13-1

Maintenance and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

332

13-2

Simple Backup Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

333

13-3 Using the Backup Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

336

SECTION 14

 

Troubleshooting and Error Processing. . . . . . . . . . . . . . . . .

339

14-1 Checking Status with the Network Configurator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

340

14-2 Using the LED Indicators and Display for Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . .

347

14-3 Connection Status Codes and Error Processing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

358

14-4

Error Log Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

364

14-5

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

368

14-6 Troubleshooting with FINS Response Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

371

ix

 

TABLE OF CONTENTS

 

Appendices

 

A

CS/CJ-series Ethernet Unit Function Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

375

B

Ethernet Network Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

377

C

TCP Status Transitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

379

D

CIP Message Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

381

E

FINS Commands Addressed to EtherNet/IP Units or Built-in EtherNet/IP Ports . . . . . . . .

391

F

EDS File Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

419

G

Precautions for Using Windows XP, Vista, or Windows 7 . . . . . . . . . . . . . . . . . . . . . . . . . .

423

Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

427

Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

435

x

About this Manual:

This manual describes the operation of the CS/CJ-series EtherNet/IP Units and the built-in EtherNet/IP ports on a CJ2 CPU Unit for constructing applications and includes the sections described below.

Please read this manual carefully and be sure you understand the information provided before attempting to install or operate the EtherNet/IP Unit or built-in EtherNet/IP port. Be sure to read the precautions provided in the following section.

Precautions provides general precautions for using the CS/CJ-series EtherNet/IP Units and built-in EtherNet/IP ports.

Section 1 introduces the functions and protocols used in EtherNet/IP Unit or built-in EtherNet/IP port communications services.

Section 2 provides the specifications of EtherNet/IP Units and introduces recommended network configuration devices.

Section 3 explains how to install and make the initial settings required for operation of the EtherNet/IP Unit or built-in EtherNet/IP port.

Section 4 describes the words allocated in the CIO Area and the DM Area for EtherNet/IP Units or built-in EtherNet/IP ports.

Section 5 explains how to manage and use IP addresses.

Section 6 describes tag data link functions and related Network Configurator operations.

Section 7 describes message communications using FINS messages and explicit messages.

Section 8 provides information on communicating on EtherNet/IP Systems and interconnected networks using FINS commands. The information provided in the section deals only with FINS communications in reference to EtherNet/IP Units or built-in EtherNet/IP ports.

Section 9 describes message communications using FINS commands sent from the ladder program in the CPU Unit of the PLC.

Section 10 describes the communications performance in an EtherNet/IP network, and shows how to estimate the I/O response times and transmission delays.

Section 11 describes the functions provided by the FTP server.

Section 12 provides an overview of the automatic clock adjustment function, including details on specifications, required settings, operations from CX-Programmer, and troubleshooting.

Section 13 describes cleaning, inspection, and Unit replacement procedures, as well as the Simple Backup Function.

Section 14 describes error processing, periodic maintenance operations, and troubleshooting procedures needed to keep the EtherNet/IP network operating properly. We recommend reading through the error processing procedures before operation so that operating errors can be identified and corrected more quickly.

Appendices provide information on EtherNet/IP network parameters, the buffer configuration, TCP status transitions, ASCII characters, maintenance, and inspections.

xi

Relevant Manuals

The following table lists CSand CJ-series manuals that contain information relevant to EtherNet/IP Units or built-in EtherNet/IP ports.

Manual

Model

Name

Contents

number

 

 

 

 

 

 

 

W465

CS1W-EIP21

EtherNet/IP Units

Provides information on operating and installing Ether-

 

CJ1W-EIP21

Operation Manual

Net/IP Units, including details on basic settings, tag data

 

CJ2H-CPU6@-EIP

(this manual)

links, and FINS communications.

 

CJ2M-CPU3@

 

Refer to the Communications Commands Reference

 

 

 

Manual (W342) for details on FINS commands that can

 

 

 

be sent to CS-series and CJ-series CPU Units when

 

 

 

using the FINS communications service.

 

 

 

Refer to the Ethernet Units Operation Manual

 

 

 

Construction of Applications (W421) for details on con-

 

 

 

structing host applications that use FINS communica-

 

 

 

tions.

 

 

 

 

W420

CS1W-ETN21

Ethernet Units Oper-

Provides information on operating and installing

 

CJ1W-ETN21

ation Manual

100Base-TX Ethernet Units, including details on basic

 

 

Construction of Net-

settings and FINS communications. Refer to the Commu-

 

 

works

nications Commands Reference Manual (W342) for

 

 

 

details on FINS commands that can be sent to CS-series

 

 

 

and CJ-series CPU Units when using the FINS communi-

 

 

 

cations service.

 

 

 

 

W421

CS1W-ETN21

Ethernet Units Oper-

Provides information on constructing host applications for

 

CJ1W-ETN21

ation Manual

100Base-TX Ethernet Units, including functions for send-

 

 

Construction of

ing/receiving mail, socket service, automatic clock adjust-

 

 

Applications

ment, FTP server functions, and FINS communications.

 

 

 

 

W343

CS1W-ETN01

Ethernet Units Oper-

Describes the installation and operation of the 10Base-5

 

CS1W-ETN11

ation Manual

and 10Base-T Ethernet Units.

 

CJ1W-ETN11

 

 

 

 

 

 

W342

CS1G/H-CPU@@H

Communications

Describes the C-series (Host Link) and FINS communi-

 

CS1G/H-CPU@@-V1

Commands Refer-

cations commands used when sending communications

 

CS1W-SCU@@-V1

ence Manual

commands to CS-series, CJ-series, CP-series, and SYS-

 

CS1W-SCB@@-V1

 

MAC One NSJ-series CPU Units.

 

CJ2H-CPU6@-EIP

 

 

 

CJ2H-CPU6@

 

 

 

CJ2M-CPU@@

 

 

 

CJ1G/H-CPU@@H

 

 

 

CJ1G-CPU@@

 

 

 

CJ1M-CPU@@

 

 

 

CJ1W-SCU@@-V1

 

 

 

CP1E-E@@D@-@

 

 

 

CP1E-N@@D@-@

 

 

 

CP1H-X@@@@-@

 

 

 

CP1H-Y@@@@-@@

 

 

W472

CJ2H-CPU6@-EIP

CJ-series CJ2 CPU

Provides hardware information for the CJ2 CPU Units.

 

CJ2H-CPU6@

Unit Hardware

Information is included on features, system configuration,

 

CJ2M-CPU@@

User’s Manual

component names, component functions, installation,

 

 

 

setting procedures, and troubleshooting.

 

 

 

Use together with the CJ-series CJ2 CPU Unit Software

 

 

 

User’s Manual (W473).

 

 

 

 

W473

CJ2H-CPU6@-EIP

CJ-series CJ2 CPU

Provides software information for the CJ2 CPU Units.

 

CJ2H-CPU6@

Unit Software User’s

Information is included on CPU Unit operation, internal

 

CJ2M-CPU@@

Manual

memory, programming, setting procedures, and CPU

 

 

 

Unit functions.

 

 

 

Use together with the CJ-series CJ2 CPU Unit Hardware

 

 

 

User’s Manual (W472).

 

 

 

 

xii

Manual

Model

Name

Contents

number

 

 

 

 

 

 

 

W474

CJ2H-CPU6@-EIP

Programmable Con-

Describes the ladder diagram programming instructions

 

CJ2H-CPU6@

trollers Instructions

supported by CS-series and CJ-series PCs. Use this

 

CJ2M-CPU@@

Reference Manual

manual for CJ2 CPU Units.

 

CS1G/H-CPU-@@H

 

 

 

CS1G/H-CPU-@@-V1

 

 

 

CJ1G/H-CPU@@H

 

 

 

CJ1M-CPU@@

 

 

 

CJ1G-CPU@@

 

 

 

NSJ@-@@@@(B)-G5D

 

 

 

NSJ@-@@@@(B)-M3D

 

 

W339

CS1G/H-CPU@@H

Programmable Con-

Provides an outline of, and describes the design, installa-

 

CS1G/H-CPU-@@V1

trollers Operation

tion, maintenance, and other basic operations for the CS-

 

 

Manual

series PLCs. Information is also included on features,

 

 

 

system configuration, wiring, I/O memory allocations, and

 

 

 

troubleshooting.

 

 

 

Use together with the Programmable Controllers Pro-

 

 

 

gramming Manual (W394).

 

 

 

 

W393

CJ1G/H-CPU@@H

Programmable Con-

Provides an outline of, and describes the design, installa-

 

CJ1G-CPU@@

trollers Operation

tion, maintenance, and other basic operations for the CJ-

 

 

Manual

series PLCs. Information is also included on features,

 

 

 

system configuration, wiring, I/O memory allocations, and

 

 

 

troubleshooting.

 

 

 

Use together with the Programmable Controllers Pro-

 

 

 

gramming Manual (W394).

 

 

 

 

W394

CS1G/H-CPU@@H

Programmable Con-

Describes programming, tasks, file memory, and other

 

CS1G/H-CPU-@@V1

trollers Program-

functions for the CS-series, CJ-series, and NS-J-series

 

CJ1G/H-CPU@@H

ming Manual

PLCs.

 

CJ1G-CPU@@

 

Use together with the Programmable Controllers Opera-

 

NSJ@-@@@@(B)-G5D

 

tion Manual (W339 for CS-series PLCs and W393 for CJ-

 

NSJ@-@@@@(B)-M3D

 

series PLCs).

 

 

 

 

W340

CS1G/H-CPU@@H

Programmable Con-

Describes the ladder diagram programming instructions

 

CS1G/H-CPU-@@V1

trollers Instructions

supported by CS-series and CJ-series PCs. Use together

 

CJ1G/H-CPU@@H

Reference Manual

with the Programmable Controllers Operation Manual

 

CJ1G-CPU@@

 

(W339 for CS-series PLCs and W393 for CJ-series

 

NSJ@-@@@@(B)-G5D

 

PLCs), and the Programmable Controllers Programming

 

NSJ@-@@@@(B)-M3D

 

Manual (W394).

W463

CXONE-AL@@C-V4

CS-One Setup Man-

Describes the setup procedures for the CX-One. Informa-

 

CXONE-AL@@D-V4

ual

tion is also provided on the operating environment for the

 

 

 

CX-One.

 

 

 

 

W446

WS02-CXPC@-V9

CX-Programmer

Provides information on how to use the CX-Programmer,

 

 

Operation Manual

a Windows-based programming device. Use together

 

 

 

with the Programmable Controllers Operation Manual

 

 

 

(W339 for CS-series PLCs and W393 for CJ-series

 

 

 

PLCs), Programmable Controllers Programming Manual

 

 

 

(W394) and the Programmable Controllers Instructions

 

 

 

Reference Manual (W340) to perform programming.

 

 

 

 

W464

CXONE-AL@@C-V4/

CS/CJ/CP/NSJ-

Describes the operating procedures of the CX-Integrator

 

CXONE-AL@@D-V4

series CX-Integrator

that can be used to set up and monitor networks.

 

 

Ver. 2.@ Operation

 

 

 

Manual

 

!WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given.

xiii

xiv

Read and Understand this Manual

Please read and understand this manual before using the product. Please consult your OMRON representative if you have any questions or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NONINFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

xv

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this manual.

Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.

Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

xvi

Omron CJ2H-CPU6-EIP, CJ2M-CPU3, CS1W-EIP21, CJ1W-EIP21 User Manual

Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this manual is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

ERRORS AND OMISSIONS

The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.

xvii

xviii

Unit Versions of CS/CJ-series

Unit Versions

A “unit version” has been introduced to manage Units in the CS/CJ Series according to differences in functionality accompanying Unit upgrades.

Notation of Unit Versions

The unit version is given to the right of the lot number on the nameplate of the

on Products

products for which unit versions are being managed, as shown below.

 

CS1W-EIP21/CJ1W-EIP21

Product nameplate

 

CS1W-

 

UNIT

 

Lot No.

 

Lot No. 040401 0000

Ver.1.0

OMRON Corporation

MADE IN JAPAN

Unit version

Example for unit version 1.0

CJ2H-CPU@@-EIP/CJ2M-CPU3@

Product nameplate

CJ2H-

 

UNIT

 

Lot No. 080701 CPU Ver. 1.0 EIP Ver.2.0

OMRON Corporation

MADE IN JAPAN

Indicates that the unit version of the CPU Unit is 1.0.

Indicates that the unit version of the built-in EtherNet I/P port is 2.0.

Confirming Unit Versions with Support Software

Note

In this manual, the version of the EtherNet/IP port built into the CJ2H- CPU@@-EIP/CJ2M-CPU3@ CPU Unit is given as the unit version.

CX-Programmer version 4.0 can be used to confirm the unit version using the

Unit Manufacturing Information.

The unit versions of Pre-Ver.1.0 Units cannot be confirmed in Unit Manufacturing Information. The following dialog box is displayed.

In the IO Table Window, right-click and select Unit Manufacturing information - CPU Unit.

The following Unit Manufacturing information Dialog Box will be displayed.

xix

Unit version

Note The unit version will be displayed in the Unit Manufacturing Information Dialog Box.

Using Unit Version Label The following unit version label is provided with the EtherNet/IP Unit.

This label can be attached to the front of the EtherNet/IP Unit to differentiate between EtherNet/IP Units with different unit versions.

Unit Versions and CX-Programmer Versions

Use the following versions of the CX-Programmer to make the Unit settings for the EtherNet/IP Unit.

Unit version

 

CX-Programmer

 

 

 

 

 

 

Ver. 7.1 or lower

Ver. 8.0

Ver. 8.02 or higher

 

 

 

 

Unit version 1.0

---

OK*

OK

 

 

 

 

Unit version 2.0

---

OK

OK

 

 

 

 

*The following auto update must be applied to use CX-Programmer version 8.0: CX-Common Components/CPS Upgrade Software 2008.08 0302

Unit Version Notation

 

In this manual, the unit version of a EtherNet/IP Unit is given as shown in the

 

 

 

following table.

 

 

 

 

 

 

 

 

 

 

 

 

Product nameplate

 

Notation used in this manual

 

Special remarks

 

 

 

 

 

 

 

 

Ver. 1.0 or later number

Ethernet Unit Ver. 1.0 or later (See note.)

 

Information without reference to specific Unit

 

shown to right of the lot

 

 

 

 

Versions applies to all versions of the Unit.

 

number

 

 

 

 

 

 

 

Note

 

Some Support Software products call the EtherNet/IP Unit version the “revi-

 

 

 

sion.” “Revision” is also sometimes used in this manual.

CIP Revisions and

 

The CIP revisions corresponding to the unit versions of the EtherNet/IP Unit

Unit Versions

 

are given in the following table.

 

 

 

 

 

 

 

 

 

 

Unit version

 

CIP revision

 

 

 

 

 

 

 

 

 

 

 

Version 1.0

Revision 1.01

 

 

 

 

 

 

 

 

 

 

 

Version 2.0

Revision 2.01 or 2.02

 

 

 

 

 

 

 

 

 

 

xx

PRECAUTIONS

This section provides general precautions for using the CS/CJ-series EtherNet/IP Units and built-in EtherNet/IP ports.

The information contained in this section is important for the safe and reliable application of EtherNet/IP Units or built-in EtherNet/IP ports. You must read this section and understand the information contained before attempting to set up or operate an EtherNet/IP Unit or built-in EtherNet/IP port.

1

Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxii

2

General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxii

3

Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxii

4

Operating Environment Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxiv

5

Application Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxiv

6

Conformance to EC Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxvi

 

6-1

Applicable Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxvi

 

6-2

Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxvi

xxi

Intended Audience

1

1 Intended Audience

This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent).

Personnel in charge of installing FA systems.

Personnel in charge of designing FA systems.

Personnel in charge of managing FA systems and facilities.

2 General Precautions

The user must operate the product according to the performance specifications described in the operation manuals.

Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative.

Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms.

This manual provides information for programming and operating the Unit. Be sure to read this manual before attempting to use the Unit and keep this manual close at hand for reference during operation.

!WARNING It is extremely important that a PLC and all PLC Units be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a PLC System to the above-mentioned applications.

3 Safety Precautions

!WARNING Do not attempt to take any Unit apart while the power is being supplied. Doing so may result in electric shock.

!WARNING Do not touch any of the terminals or terminal blocks while the power is being supplied. Doing so may result in electric shock.

!WARNING Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so may result in malfunction, fire, or electric shock.

xxii

Safety Precautions

3

!WARNING Provide safety measures in external circuits (i.e., not in the Programmable Controller), including the following items, to ensure safety in the system if an abnormality occurs due to malfunction of the Programmable Controller or another external factor affecting the operation of the Programmable Controller. “Programmable Controller” indicates the CPU Unit and all other Units and is abbreviated “PLC” in this manual.

Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits.

The PLC will turn OFF all outputs when its self-diagnosis function detects any error or when a severe failure alarm (FALS) instruction is executed. As a countermeasure for such errors, external safety measures must be provided to ensure safety in the system.

The PLC will turn OFF all outputs when its self-diagnosis function detects any error or when a severe failure alarm (FALS) instruction is executed. Unexpected operation, however, may still occur for errors in the I/O control section, errors in I/O memory, and other errors that cannot be detected by the self-diagnosis function. As a countermeasure for all such errors, external safety measures must be provided to ensure safety in the system.

Provide measures in the computer system and programming to ensure safety in the overall system even if errors or malfunctions occur in data link communications or remote I/O communications.

!Caution Execute online editing only after confirming that no adverse effects will be caused by extending the cycle time. Otherwise, the input signals may not be readable.

Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits.

!Caution Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. Serious accidents may result from abnormal operation if proper measures are not provided.

!Caution Confirm safety at the destination node before changing or transferring to another node the contents of a program, the PLC Setup, I/O tables, I/O memory, or parameters. Changing or transferring any of these without confirming safety may result in injury.

!Caution Tighten the screws on the terminal block of the AC Power Supply Unit to the torque specified in the operation manual. The loose screws may result in burning or malfunction.

xxiii

Operating Environment Precautions

4

4 Operating Environment Precautions

!Caution Do not operate the control system in the following locations:

Locations subject to direct sunlight.

Locations subject to temperatures or humidity outside the range specified in the specifications.

Locations subject to condensation as the result of severe changes in temperature.

Locations subject to corrosive or flammable gases.

Locations subject to dust (especially iron dust) or salts.

Locations subject to exposure to water, oil, or chemicals.

Locations subject to shock or vibration.

!Caution Take appropriate and sufficient countermeasures when installing systems in the following locations:

Locations subject to static electricity or other forms of noise.

Locations subject to strong electromagnetic fields.

Locations subject to possible exposure to radioactivity.

Locations close to power supplies.

5 Application Precautions

Observe the following precautions when using the EtherNet/IP Unit or built-in

EtherNet/IP port.

!WARNING Always heed these precautions. Failure to abide by the following precautions could lead to serious or possibly fatal injury.

Always connect to a ground of 100 Ω or less when installing the Units. Not connecting to a ground of 100 Ω or less may result in electric shock.

Always turn OFF the power supply to the CPU Unit and Slaves before attempting any of the following. Not turning OFF the power supply may result in malfunction or electric shock.

Mounting or dismounting Power Supply Units, I/O Units, CPU Units, Memory Packs, or Master Units.

Assembling the Units.

Setting DIP switches or rotary switches.

Connecting cables or wiring the system.

Connecting or disconnecting the connectors.

!Caution Failure to abide by the following precautions could lead to faulty operation of the EtherNet/IP Unit, built-in EtherNet/IP port, or the system, or could damage the Ethernet Unit. Always heed these precautions.

Interlock circuits, limit circuits, and similar safety measures in external circuits (i.e., not in the Programmable Controller) must be provided by the customer.

xxiv

Application Precautions

5

Always use the power supply voltages specified in the operation manuals. An incorrect voltage may result in malfunction or burning.

Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied. Be particularly careful in places where the power supply is unstable. An incorrect power supply may result in malfunction.

Install external breakers and take other safety measures against short-cir- cuiting in external wiring. Insufficient safety measures

Make sure that all the Backplane mounting screws, terminal block screws, and cable connector screws are tightened to the torque specified in the relevant manuals. Incorrect tightening torque may result in malfunction.

Leave the label attached to the Unit when wiring. Removing the label may result in malfunction if foreign matter enters the Unit.

Remove the label after the completion of wiring to ensure proper heat dissipation. Leaving the label attached may result in malfunction.

Use crimp terminals for wiring. Do not connect bare stranded wires directly to terminals. Connection of bare stranded wires may result in burning.

Observe the following precautions when wiring the communications cable.

Separate the communications cables from the power lines or high-ten- sion lines.

Do not bend the communications cables past their natural bending radius.

Do not pull on the communications cables.

Do not place heavy objects on top of the communications cables.

Always lay communications cable inside ducts.

Use appropriate communications cables.

Make sure that the terminal blocks, expansion cable connectors, and other items with locking devices are locked in place.

Wire all connections correctly according to instructions in this manual.

Double-check all wiring and switch settings before turning ON the power supply. Incorrect wiring may result in burning.

Mount terminal blocks and connectors only after checking the mounting location carefully.

Check the user program (ladder program and other programs) and parameters for proper execution before actually running it on the Unit. Not checking the program may result in unexpected operation.

Confirm that no adverse effect will occur in the system before attempting any of the following. Not doing so may result in an unexpected operation.

Changing the operating mode of the PLC.

Force-setting/force-resetting any bit in memory.

Changing the present value of any word or any set value in memory.

After replacing a Unit, resume operation only after transferring to the new CPU Unit, Special I/O Unit, or CPU Bus Unit the contents of the DM Area, HR Area, programs, parameters, and other data required for resuming operation. Not doing so may result in an unexpected operation.

Before touching a Unit, be sure to first touch a grounded metallic object in order to discharge any static build-up. Not doing so may result in malfunction or damage.

xxv

Conformance to EC Directives

6

When transporting the Unit, use special packing boxes and protect it from being exposed to excessive vibration or impacts during transportation.

CPU Bus Units will be restarted when routing tables are transferred from a Programming Device to the CPU Unit. Restarting these Units is required to read and enable the new routing tables. Confirm that the system will not be adversely affected before allowing the CPU Bus Units to be reset.

When the settings (IP address or tag data link settings) of the EtherNet/IP Unit or built-in EtherNet/IP port are transferred from a Programming Device, all of the destination EtherNet/IP Units or built-in EtherNet/IP ports (nodes) will be reset in order to enable the transferred settings. Transfer settings to the EtherNet/IP Units or built-in EtherNet/IP ports only after verifying that restarting the Units will not cause any problems in the system.

If a repeater hub is used for EtherNet/IP tag data links (cyclic communications), the network's communications load will increase, data collisions will occur frequently, and stable communications will be impossible. Always use a switching hub when using tag data links in the network.

Before resetting a CPU Bus Unit or Special I/O Unit, always verify that restart the Unit will not cause any problems in the system.

6 Conformance to EC Directives

6-1 Applicable Directives

EMC Directives

Low Voltage Directive

6-2 Concepts

EMC Directives

OMRON devices that comply with EC Directives also conform to the related EMC standards so that they can be more easily built into other devices or the overall machine. The actual products have been checked for conformity to EMC standards (see the following note). Whether the products conform to the standards in the system used by the customer, however, must be checked by the customer.

EMC-related performance of the OMRON devices that comply with EC Directives will vary depending on the configuration, wiring, and other conditions of the equipment or control panel on which the OMRON devices are installed. The customer must, therefore, perform the final check to confirm that devices and the overall machine conform to EMC standards.

Note Applicable EMS (Electromagnetic Susceptibility) and EMI (Electromagnetic Interference) Standards in the EMC (Electromagnetic Compatibility) standards are as follows:

EtherNet/IP Unit

EMS

EMI

 

 

 

CS1W-EIP21

EN61000-6-2

EN61000-6-4

 

 

(Radiated emission: 10-m

CJ1W-EIP21

 

 

regulations)

 

 

Low Voltage Directive

Always ensure that devices operating at voltages of 50 to 1,000 V AC and 75 to 1,500 V DC meet the required safety standards for the PLC (EN61131-2).

xxvi

SECTION 1

Overview of EtherNet/IP

This section introduces the functions and protocols used in EtherNet/IP Unit or built-in EtherNet/IP port communications services.

1-1

EtherNet/IP Unit Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1-2 Devices Required for Constructing a Network . . . . . . . . . . . . . . . . . . . . . . . .

4

1-3

Support Software Required to Construct a Network. . . . . . . . . . . . . . . . . . . .

4

1-4

Communications Services Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

1-5

Network Configurator Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

 

1-5-1

Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

 

1-5-2

Network Configurator Requirements . . . . . . . . . . . . . . . . . . . . . . . .

10

 

1-5-3

Precautions When Using the Network Configurator . . . . . . . . . . . .

11

1

EtherNet/IP Unit Features Section 1-1

1-1 EtherNet/IP Unit Features

CX-One Support

(3) Switching hub

 

 

 

 

 

 

Software

 

 

 

 

 

 

(2) Twisted-pair cable

 

(1) Built-in EtherNet/IP port on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 m

(1) CS1W-EIP21 EtherNet/IP

(1) CJ1W-EIP21

CJ2 CPU Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CJ2H-CPU@@-EIP/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max.

Unit for CS-series

EtherNet/IP Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ2M-CPU3@)

Ethernet (LAN) port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-series

CJ-series

CJ-series

PLC

PLC

PLC

High-speed, High-capacity Data Exchange through Data Links

Tag Data Link (Cyclic

Communications) Cycle

Time

Note

Communicating with FINS Messages (FINS/TCP and FINS/UDP)

Note

Network Connections with Controller Link

EtherNet/IP System Configuration Example

EtherNet/IP is an industrial multi-vendor network that uses Ethernet components. The EtherNet/IP specifications are open standards managed by the ODVA (Open DeviceNet Vendor Association), just like DeviceNet.

EtherNet/IP is not just a network between controllers; it is also used as a field network. Since EtherNet/IP uses standard Ethernet technology, various gen- eral-purpose Ethernet devices can be used in the network. The EtherNet/IP Unit and built-in EtherNet/IP port have the following features.

The EtherNet/IP protocol supports implicit communications, which allows cyclic communications (called tag data links in this manual) with EtherNet/IP devices. Data can be exchanged at high speed between Controllers and devices, using high-volume tag sets (up to 640 words for the CJ2M and up to 184,832 words for other CPU Units) between PLCs.

Tag data links (cyclic communications) can operate at the cyclic period specified for each application, regardless of the number of nodes. Data is exchanged over the network at the refresh cycle set for each connection, so the communications refresh cycle will not increase even if the number of nodes is increased, i.e., the synchronicity of the connection’s data is preserved.

Since the refresh cycle can be set for each connection, each application can communicate at its ideal refresh cycle. For example, a processes interlocks can be transferred at high speed while the production commands and the status monitor information are transferred at low speed.

The communications load to the nodes must be within the Units’ allowed communications bandwidth.

Data can be exchanged with other OMRON FA devices using SEND, RECV, and CMND instructions from the ladder program, because EtherNet/IP supports OMRON’s standard FINS message communications services.

There are two kinds of message services, using UDP/IP and TCP/IP (called FINS/UDP and FINS/TCP), allowing flexible data exchange for different applications.

There are no particular restrictions when sending FINS messages to OMRON Ethernet Units (CS1W-ETN21 or CJ1W-ETN21) in an Ethernet network.

Mutual connections of Controller Link and EtherNet/IP are also supported (using the FINS communications service). The Controller Link connection allows a PLC on the Controller Link network to be monitored from a PLC on the EtherNet/IP network. Conversely, data can be exchanged with a PLC on the EtherNet/IP network from a PLC on the Controller Link network.

2

EtherNet/IP Unit Features

Section 1-1

FTP Server

Automatic PLC Clock

Adjustment

Note

Manage the Network with an SNMP Manager

Note

Specify Servers with Host Names

Note

Set Classless IP Address with CIDR

Plentiful Troubleshooting

Functions

Note

A built-in FTP server is provided to enable transferring files in the PLC to and from a host computer. This enables transferring large amounts of data from a client without any additional ladder programming.

The clocks built into PLCs connected to Ethernet can be automatically adjusted to the time of the clock in the SNTP server. If all of the clocks in the system are automatically adjusted to the same time, time stamps can be used to analyze various production histories.

A separate SNTP server is necessary to automatically adjust the PLC clocks.

Internal status information from the EtherNet/IP Unit or built-in EtherNet/IP port can be passed to network management software that uses an SNMP manager.

A separate SNMP manager is necessary for network management.

DNS client functionality allows you to use host names instead of IP addresses to specify SNTP servers and SNMP managers. This is useful, for example, when server IP addresses change for system revisions because the IP addresses are automatically found when host names are used.

(1)A separate DNS server is necessary to use host names with the DNS client.

(2)The DNS server is specified directly using its IP address.

A subnet mask can be set to use classless IP addresses, allowing more flexibility in address settings.

A variety of functions are provided to quickly identify and handle errors.

Self-diagnosis at power ON

PING command to check the connection with another node

Error Log functions record the time of occurrence and other error details

The CIP (Common Industrial Protocol) is a shared industrial protocol for the OSI application layer. The CIP is used in networks such as EtherNet/IP, ControlNet, and DeviceNet. Data can be routed easily between networks that are based on the CIP, so a transparent network can be easily configured from the field device level to the host level.

The CIP has the following advantages.

Destination nodes are specified by a relative path, without fixed routing tables.

The CIP uses the producer/consumer model. Nodes in the network are arranged on the same level and it is possible to communicate with required devices whenever it is necessary.

The consumer node will receive data sent from a producer node when the connection ID in the packet indicates that the node requires the data. Since the producer can send the same data with the same characteristics in a multicast (either multicast or unicast can be selected), the time required for the transfer is fixed and not dependent on the number of consumer nodes.

3

Devices Required for Constructing a Network

Section 1-2

1-2 Devices Required for Constructing a Network

The basic configuration for an EtherNet/IP System consists of one switching hub to which nodes are attached in star configuration using twisted-pair cable.

CX-One Support

(3) Switching hub

 

 

 

 

 

 

Software

 

 

 

 

 

 

(2) Twisted-pair cable

 

(1) Built-in EtherNet/IP port on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 m

(1) CS1W-EIP21 EtherNet/IP

(1) CJ1W-EIP21

CJ2 CPU Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max.

Unit for CS-series

EtherNet/IP Unit

(CJ2H-CPU@@-EIP/

Ethernet (LAN) port

 

 

 

 

 

 

 

CJ2M-CPU3@)

 

 

 

 

 

 

 

 

CS-series

CJ-series

CJ-series

PLC

PLC

PLC

Recommended

Switching Hubs

The devices shown in the following table are required to configure a network with CS1W-EIP21 and CJ1W-EIP21 EtherNet/IP Units or the built-in EtherNet/ IP port in CJ2H-CPU@@-EIP/CJ2M-CPU3@ CPU Units.

Network device

Contents

 

 

(1) CS1W-EIP21 EtherNet/IP

These are Communications Units or built-in ports

Units for CS-series PLCs,

that connect a CS-series or CJ-series PLC to an Eth-

CJ1W-EIP21 EtherNet/IP

erNet/IP network.

Units for CJ-series PLCs,

 

or built-in EtherNet/IP port

 

in CJ2H-CPU@@-EIP/

 

CJ2M-CPU3@ CPU Units

 

(2) Twisted-pair cable

The twisted-pair cable connects EtherNet/IP Units or

 

built-in EtherNet/IP ports to the switching hub, with

 

an RJ45 Modular Connector at each end.

 

Use an STP (shielded twisted-pair) cable of category

 

5, 5c, or higher.

 

 

(3) Switching Hub

This is a relay device that connects multiple nodes in

 

a star-shaped LAN.

 

 

For details on recommended devices for constructing a network, refer to 2-3-1 Recommended Network Devices.

Note If a repeater hub is used for EtherNet/IP tag data links (cyclic communications), the network’s communications load will increase, data collisions will occur frequently, and stable communications will be impossible. Always use a switching hub when using tag data links in the network.

1-3 Support Software Required to Construct a Network

Unit Setup: CX-

Programmer

This section describes the Support Software that is required to construct an EtherNet/IP network. Make the tag data link settings and Unit setup settings for the EtherNet/IP Unit or built-in EtherNet/IP port. Both of these settings are stored in the EtherNet/IP Unit’s non-volatile memory (See note.). Support Software is provided for each, as described below.

Note Unlike the Ethernet Units, the EtherNet/IP Unit’s TCP/IP settings are not stored in the CPU Unit’s CPU Bus Unit System Setup Area. The settings are stored in the EtherNet/IP Unit itself.

The CX-Programmer is used to set basic parameters, such as the local IP address of the EtherNet/IP Unit or built-in EtherNet/IP port and the subnet mask. (The CX-Programmer is included in the CX-One.)

The CX-Programmer can also be used to check if data I/O is being performed correctly for tag data links.