Omron M6 User Manual

4 (1)
Omron M6 User Manual

Digital Automatic Blood Pressure Monitor

Model M6 Comfort

Instruction Manual

Mode d’emploi

Gebrauchsanweisung

Manuale di istruzioni

Manual de instrucciones

Gebruiksaanwijzing

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

EN

FR

DE

IT

ES

NL

RU

IM-HEM-7000-E-01-05/06

Contents

Introduction ..............................................................................

3

Important Safety Information ..................................................

4

1.

Overview ..............................................................................

5

2.

Preparation ..........................................................................

7

 

2.1

Installing/Replacing the Batteries.....................................

7

 

2.2

Setting the Date and Time ...............................................

8

3.

Using the Unit....................................................................

10

 

3.1

How to Sit Correctly When Taking a Measurement .......

10

 

3.2

Applying the Arm Cuff ....................................................

12

 

3.3

Taking a Reading...........................................................

15

 

3.4

Instructions for Special Conditions.................................

18

 

3.5

Using the Memory Function ...........................................

19

4.

Quick Reference Guide.....................................................

21

5.

Handling Errors and Problems ........................................

22

 

5.1

Error Messages..............................................................

22

 

5.2

Troubleshooting .............................................................

23

6.

Maintenance and Storage.................................................

24

7.

Optional Parts....................................................................

25

8.

Technical Data...................................................................

26

9.

Some Useful Information about Blood Pressure ...........

28

2

Introduction

The OMRON M6 Comfort is a compact, fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the devices uses its advanced “IntelliSense” technology.

The device also stores up to 90 measurements in memory and calculates an average value based on the last three measurements taken within 10 minutes. Each measurement is stored along with the date and time of measurement.

Please read this instruction manual thoroughly before using the unit. Please keep for future reference.

For specific information about your own blood pressure, CONSULT YOUR DOCTOR.

EN

3

Important Safety Information

Blood pressure measurement is not suitable in cases of serious arteriosclerosis (hardening of the arteries).

The pulse display is not suitable for monitoring the frequency of cardiac pacemakers.

Pregnant women should only measure their own blood pressure in consultation with their doctor, since the readings can be changed by pregnancy.

Do not use the monitor on babies, young children or persons who cannot express their consent.

Do not use the monitor for any purpose other than measuring blood pressure.

The battery liquid may leak and damage the monitor. Please observe the following points.

-When you are not going to use the unit for a long period of time (approximately three months or more), take out the batteries.

-Replace old batteries with new ones immediately.

-Do not use old and new batteries together.

-Do not insert the batteries with their polarities incorrectly aligned.

Please remember: Self-measurement is not the same as medical treatment.

You should never change the dose of medicines prescribed by your doctor but you can help your doctor to optimize the treatment by documenting the measured values. If there are unusual values, please inform your doctor immediately.

Never unplug the power cord with wet hands.

Use only the original AC adapter designed for this unit. Use of unsupported adapters may damage the device.

Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section.

4

1.Overview

1.Overview

Monitor

A

E

 

B

 

 

D

 

 

G

C

 

F

 

 

A. Display

 

E. Battery compartment

 

B. O/I START button

F. Air jack

 

C. Memory (

) buttons

G. AC adapter jack (for optional

D. Date/Time (

) setting

AC adapter)

 

button

 

 

 

EN

5

1.Overview

Display

H

I

J K O P

L M Q R

N

H.Systolic blood pressure

I.Diastolic blood pressure

J.Memory symbol

K.Average value symbol

L.Movement error symbol

M.Irregular heartbeat symbol

N.Battery low symbol

O.Heartbeat symbol

1.Flashes during measurement

2.If flashing after measurement complete indicates blood pressure out of recommended range

P.Pulse display

Q.Deflation symbol

R.Date/Time display

Package contents

S

 

 

 

V

 

T

U

W

 

 

 

S. Arm cuff (Arm circumference

V. Storage case

T.

22-42 cm)

 

W. Four “AA” alkaline (LR6)

Air plug

 

batteries

U.

Air tube

 

 

6

2.Preparation

2. Preparation

2.1Installing/Replacing the Batteries

1. Remove the battery cover.

2. Insert four “AA” batteries as indicated in the battery compartment and then replace the battery cover.

Notes:

If the battery low symbol ( ) appears on the display, replace all four batteries at the same time.

- When the battery low symbol ( ) starts to blink, you will still

be able to use the unit for a short while. You should replace EN the batteries with new ones ahead of time. Long-life alkaline batteries are recommended.

-When the symbol ( ) remains lit, the batteries are exhausted. You should replace the batteries with new ones at once. Turn the unit off before replacing the batteries.

Remove the batteries if the monitor will not be used for three months or more.

If the batteries are removed for 30 seconds or more, the Date/ Time setting will need to be reset. See “Setting the Date and Time” for details.

Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries.

7

2.Preparation

2.2Setting the Date and Time

Your blood pressure monitor automatically stores up to 90 measurements values in its memory and calculates an average reading based on the measurements from the last three readings taken within 10 minutes.

Set the monitor to the correct date and time before taking a measurement for the first time.

If the batteries have been removed for 30 seconds or more, the date and time setting will need to be reset.

1. When the batteries are installed, the year digits will flash in the display when you turn on the monitor.

Note: If you need to reset the date and time for some reason,

hold down the button while the power is off.

2. Press the button to advance the digits one at a time.

To change the digits to a lower

number, press the button to lower the digits one at a time.

If you hold down the or button, the digits will advance (or lower) rapidly.

3. Press the button to confirm the setting when the desired number appears on the display.

8

2.Preparation

4. Repeat steps 2 and 3 to set the month and date (day).

or

or

5. Repeat steps 2 and 3 to set the hour and minutes for the time.

or

EN

or

6. Press the O/I START button when you have finished setting the date and time.

9

Loading...
+ 21 hidden pages