General-purpose Limit Switch
D4A-@N
CSM_D4A-_N_DS_E_4_1
The Limit Switch with Better Seal, Shock
Resistance, and Strength
•A double seal on the head, a complete gasket cover, and other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
•Wide standard operating temperature range: −40°C to +100°C (standard type).
•Models with fluoro-rubber available for greater resistance to chemicals.
•Block mounting method also reduces downtime for maintenance.
•DPDT, double-break models available for complex operations.
•Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
Be sure to read Safety Precautions on page 14 to 15 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
D4A-@@@@N (Set model number)
(1)(2) (3)
(1)Receptacle box
1: 1/2-14 NPT conduit (SPDT, double-break)
2: 1/2-14 NPT conduit (DPDT, double-break)
3: G 1/2 conduit (SPDT, double-break)
4: G 1/2 conduit (DPDT, double-break)
(2) Switch Box
1 : SPDT, double-break, without indicator
3 : SPDT, double-break, neon lamp
E : SPDT, double-break, LED (24 VDC, leakage current: 1.3 mA) 5 : DPDT, double-break, simultaneous operation, without indicator 7 : DPDT, double-break, sequential operation, without indicator *1
9 : DPDT, double-break, center neutral operation, without indicator *2 L : DPDT, double-break, simultaneous operation, neon lamp
P : DPDT, double-break, simultaneous operation, LED
*1. Use the D4A-0017N Special Head.
*2. Use the D4A-0018N Special Head.
Note: Fluoro-rubber sealed type is also available.
(3) Head
01 : Roller lever, standard
02 : Roller lever, high-sensitivity
03 : Roller lever, low torque
04 : Roller lever, high-sensitivity, low torque
05 : Roller lever, maintained
17: Roller lever, sequential operation
18: Roller lever, center neutral operation
06: Side plunger, standard
07-V : Side plunger, vertical roller
07-H : Side plunger, horizontal roller
08 : Side plunger, adjustable
09: Top plunger, standard
10: Top plunger, roller
11: Top plunger, adjustable
12: Flexible rod, spring wire
14: Flexible rod, plastic rod
15: Flexible rod, cat whisker
16: Flexible rod, coil spring
1
|
|
|
|
|
|
|
|
|
|
D4A-@N |
Ordering Information |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Set model number |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SPDT, Double-break Switches |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Receptacle box |
|
|
G 1/2 Conduit |
|
|
|||
|
|
Indicator |
Without indicator |
With neon lamp indicator (AC) |
With LED indicator (DC) |
|||||
|
|
|
|
|
|
Model |
Approved |
Model |
Approved |
Model |
Actuator |
|
|
|
|
|
standards |
standards |
|||
|
|
|
|
|
|
|
|
|||
|
Standard |
|
|
|
|
D4A-3101N |
UL, CSA |
D4A-3301N |
UL, CSA |
D4A-3E01N |
|
|
|
|
|
||||||
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
High-sensitivity |
|
|
|
|
D4A-3102N |
UL, CSA |
D4A-3302N |
UL, CSA |
D4A-3E02N |
|
|
|
|
|
||||||
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
Roller lever *1 |
Low-torque |
|
|
|
|
D4A-3103N |
UL, CSA |
--- |
--- |
--- |
|
|
|
|
|||||||
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
High-sensitivity, |
|
|
|
|
D4A-3104N |
UL, CSA |
D4A-3304N |
UL, CSA |
--- |
|
|
|
|
|
||||||
|
Low-torque |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
Maintained *2 |
|
|
|
|
D4A-3105N |
UL, CSA |
D4A-3305N |
UL, CSA |
D4A-3E05N |
|
|
|
|
|
||||||
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
Standard |
|
|
|
|
D4A-3106N |
UL, CSA |
--- |
--- |
--- |
|
|
|
|
|
|
|
|
|
|
|
Side plunger |
Vertical roller |
|
|
|
|
D4A-3107-VN |
UL, CSA |
D4A-3307-VN |
UL, CSA |
D4A-3E07-VN |
|
|
|
|
|||||||
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
Horizontal roller |
|
|
|
|
D4A-3107-HN |
UL, CSA |
D4A-3307-HN |
UL, CSA |
--- |
|
|
|
|
|
||||||
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
Adjustable |
|
|
|
|
D4A-3108N |
UL, CSA |
D4A-3308N |
UL, CSA |
D4A-3E08N |
|
|
|
|
|
||||||
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
Standard |
|
|
|
|
D4A-3109N |
UL, CSA |
D4A-3309N |
UL, CSA |
--- |
|
|
|
|
|
|
|
|
|
|
|
Top plunger |
Roller |
|
|
|
|
D4A-3110N |
UL, CSA |
D4A-3310N |
UL, CSA |
--- |
|
|
|
|
|
|
|
|
|
|
|
|
Adjustable |
|
|
|
|
D4A-3111N |
UL, CSA |
D4A-3311N |
UL, CSA |
--- |
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
Spring wire |
|
|
|
|
D4A-3112N |
UL, CSA |
D4A-3312N |
UL, CSA |
D4A-3E12N |
|
|
|
|
|
|
|
|
|
|
|
|
Plastic rod |
|
|
|
|
D4A-3114N |
UL, CSA |
D4A-3314N |
UL, CSA |
D4A-3E14N |
Flexible rod |
|
|
|
|
|
|
|
|
|
|
Cat whisker |
|
|
|
|
D4A-3115N |
UL, CSA |
D4A-3315N |
UL, CSA |
D4A-3E15N |
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
Coil spring |
|
|
|
|
D4A-3116N |
UL, CSA |
D4A-3316N |
UL, CSA |
D4A-3E16N |
|
|
|
|
|
|
|
|
|
|
|
Note: 1. Switches are also available with @1/2-14 NPT conduits. The model numbers correspond as follows: |
|
|
||||||||
(Examples) |
G 1/2 Conduits |
1/2-14 NPT Conduits |
|
|
|
|
||||
|
D4A-3@@@N |
D4A-1@@@N |
|
|
|
|
|
|||
|
D4A-4@@@N |
D4A-2@@@N |
|
|
|
|
|
2.Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is −10 to +120°C.) Add “-F” to the model number. (Example: D4A-3101N becomes D4A-3101N-F.) Ask your nearest OMRON representative for details.
*1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer to Levers on page 12). *2. The Maintained Switches have a lock mechanism for the switch operation and thus use a Fork Lever Lock.
2
|
|
|
|
|
|
|
|
|
|
D4A-@N |
|
|
|
|
|
|
|
|
|
|
|
DPDT, Double-break Switches |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Receptacle box |
|
|
G 1/2 Conduit |
|
|||||
|
|
Indicator |
|
Without indicator |
With neon lamp indicator (AC) |
With LED indicator (DC) |
||||
Actuator |
|
|
|
|
|
Model |
|
Approved standards |
Model |
Model |
|
Standard |
|
|
|
|
D4A-4501N |
|
UL, CSA |
D4A-4L01N |
D4A-4P01N |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
High-sensitivity |
|
|
|
|
D4A-4502N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
Low-torque |
|
|
|
|
D4A-4503N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
Roller lever *1 |
High-sensitivity, |
|
|
|
|
D4A-4504N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
||||||
Low-torque |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
Maintained *2 |
|
|
|
|
D4A-4505N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
Sequential operation |
|
|
|
D4A-4717N |
|
UL, CSA |
--- |
--- |
|
|
|
|
||||||||
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Center neutral |
|
|
|
|
D4A-4918N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|||||
|
operation |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
Standard |
|
|
|
|
D4A-4506N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|
|
|
|
|
Side plunger |
Vertical roller |
|
|
|
|
D4A-4507-VN |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
||||||
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
Horizontal roller |
|
|
|
|
D4A-4507-HN |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
Adjustable |
|
|
|
|
D4A-4508N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
Standard |
|
|
|
|
D4A-4509N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|
|
|
|
|
Top plunger |
Roller |
|
|
|
|
D4A-4510N |
|
UL, CSA |
D4A-4L10N |
D4A-4P10N |
|
|
|
|
|
|
|
|
|
|
|
|
Adjustable |
|
|
|
|
D4A-4511N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
Spring wire |
|
|
|
|
D4A-4512N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|
|
|
|
|
|
Plastic rod |
|
|
|
|
D4A-4514N |
|
UL, CSA |
--- |
--- |
Flexible rod |
|
|
|
|
|
|
|
|
|
|
Cat whisker |
|
|
|
|
D4A-4515N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
Coil spring |
|
|
|
|
D4A-4516N |
|
UL, CSA |
--- |
--- |
|
|
|
|
|
|
|
|
|
||
Note: 1. Switches are also available with @1/2-14 NPT conduits. The model numbers correspond as follows: |
|
|
||||||||
(Examples) |
G 1/2 Conduits |
1/2-14 NPT Conduits |
|
|
|
|
||||
|
D4A-3@@@N |
D4A-1@@@N |
|
|
|
|
||||
|
D4A-4@@@N |
D4A-2@@@N |
|
|
|
|
2.Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however,
is −10 to +120°C.) Add “-F” to the model number. (Example: D4A-4501N becomes D4A-4501N-F.) Ask your nearest OMRON representative about delivery
times and prices.
*1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer to Levers on page 12). *2. The Maintained Switches have a lock mechanism for the switch operation and thus use a Fork Lever Lock.
Individual Parts
Receptacle box
Type |
|
G1/2 conduit *1 |
1/2-14NPT conduit *2 |
||
Appearance |
Model |
Approved standards |
Model |
Approved standards |
|
SPDT dou- |
D4A-3000N |
UL, CSA |
D4A-1000N |
UL, CSA |
|
ble-break |
|||||
|
|
|
|
||
|
|
|
|
|
DPDT dou- |
|
D4A-4000N |
UL, CSA |
D4A-2000N |
UL, CSA |
*1. |
M6-screw mounting |
ble-break |
|
||||||
|
|
|
|
|
|||
|
|
|
|
|
|
|
(standard mounting) |
|
|
|
|
|
|
*2. |
10-32UNF-screw mounting |
|
|
|
|
|
|
|
(standard mounting) |
|
|
|
|
|
|
|
|
3
D4A-@N
Switch Box
|
|
Indicator |
Without indicator |
With neon lamp indicator (AC) |
With LED |
||
|
|
indicator (DC) |
|||||
|
|
|
|
|
|
|
|
Appearance |
|
|
Model |
Approved |
Model |
Approved |
Model |
|
|
standards |
standards |
||||
|
|
|
|
|
|
||
SPDT double- |
|
|
D4A-0100N |
UL, CSA |
D4A-0300N |
UL, CSA |
D4A-0E00N |
break |
|
|
|||||
|
|
|
|
|
|
|
|
|
(Without indicator lamp) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Simultaneous |
D4A-0500N |
UL, CSA |
D4A-0L00N |
--- |
D4A-0P00N |
|
|
operation |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DPDT double- |
|
Sequential |
D4A-0700N |
UL, CSA |
--- |
--- |
--- |
|
operation |
||||||
break |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Center neutral |
D4A-0900N |
UL, CSA |
--- |
--- |
--- |
|
|
operation |
|||||
|
(Without indicator lamp) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Heads
|
|
|
Model |
Approved |
|
Appearance |
standards |
||
|
|
|||
|
|
Standard |
D4A-0001N |
UL, CSA |
|
|
High-sensitivity |
D4A-0002N |
UL, CSA |
<![if ! IE]> <![endif]>*1 |
|
Low-torque *2 |
D4A-0003N |
UL, CSA |
|
Sequential oper- |
|
|
|
<![if ! IE]> <![endif]>lever |
|
D4A-0017N |
UL, CSA |
|
|
ation: *3 |
|||
|
|
|||
|
|
|
|
|
<![if ! IE]> <![endif]>Roller |
|
Center neutral |
D4A-0018N |
UL, CSA |
|
operation: *3 |
|||
|
|
|||
|
|
|
|
|
|
|
Maintained |
D4A-0005N |
UL, CSA |
|
|
|
|
|
|
|
Standard |
D4A-0006N |
UL, CSA |
<![if ! IE]> <![endif]>plungerSide |
|
|
|
|
|
Horizontal roller |
D4A-0007-HN |
UL, CSA |
|
|
|
Vertical roller |
D4A-0007-VN |
UL, CSA |
|
|
|
|
|
|
|
Side adjustable |
D4A-0008N |
UL, CSA |
|
|
|
|
|
*1. Levers for Roller Lever Switches are optionally available. Select the lever from those listed in this data sheet and order (refer to Levers on page 12).
*2. The D4A-C00 adjustable roller lever is too heavy and long for these heads and it should not be used or mechanical malfunction will result.
*3. These heads cannot be used for double break operations.
<![endif]>Top plunger
<![if ! IE]><![endif]>Flexible rod
|
|
Model |
Approved |
|
Appearance |
Type |
standards |
||
|
||||
|
|
|
|
|
|
Standard |
D4A-0009N |
UL, CSA |
|
|
|
|
|
|
|
Roller |
D4A-0010N |
UL, CSA |
|
|
|
|
|
|
|
Adjustable |
D4A-0011N |
UL, CSA |
Spring wire |
D4A-0012N |
UL, CSA |
Plastic rod |
D4A-0014N |
UL, CSA |
Cat whisker |
D4A-0015N |
UL, CSA |
Coil spring |
D4A-0016N |
UL, CSA |
4
D4A-@N
Levers
Actuator |
Model |
|
|
D4A-A00 |
|
|
|
|
|
D4A-A10 |
|
|
|
|
Roller Lever |
D4A-A20 |
|
|
|
|
|
D4A-A30 |
|
|
|
|
|
D4A-B06 |
|
|
|
|
Adjustable Roller Lever |
D4A-C00 |
|
|
||
D4A-D00 |
||
|
||
|
|
|
Resin Loop Lever |
D4A-F00 |
|
|
|
|
|
D4A-E30 |
|
|
|
|
Fork Lever Lock |
D4A-E20 |
|
|
||
D4A-E10 |
||
|
||
|
|
|
|
D4A-E00 |
|
|
|
Note: Refer to page 12 for Lever shapes and applicable models.
Specifications
Approved Standards
Agency |
Standard |
File No. |
UL |
UL508 |
E76675 |
|
|
|
CSA |
CSA C22.2 No.14 |
LR45746 |
|
|
|
CCC (CQC) |
GB14048.5 |
2003010305077615 |
|
|
|
Note: Ask your OMRON representative for information on approved models.
Ratings
|
|
Non-inductive load (A) |
Inductive load (A) |
|||||||||
Type |
Rated |
Resistive |
Lamp load |
Inductive |
Motor load |
|||||||
|
voltage |
load |
|
|
|
load |
|
|
|
|||
|
|
NC |
|
NO |
NC |
|
NO |
NC |
NO |
NC |
|
NO |
|
125 VAC * |
10 |
|
10 |
3 |
|
1.5 |
10 |
5 |
|
2.5 |
|
SPDT |
250 VAC * |
10 |
|
10 |
2 |
|
1 |
10 |
3 |
|
1.5 |
|
480 VAC |
10 |
|
10 |
1.5 |
|
0.8 |
3 |
|
1.5 |
|
0.8 |
|
double- |
|
|
|
|
||||||||
600 VAC |
3 |
|
1 |
1 |
|
0.5 |
1.5 |
1 |
|
0.5 |
||
break |
|
|
|
|||||||||
8 VDC |
10 |
6 |
|
3 |
10 |
|
|
6 |
|
|||
(with/ |
|
|
|
|
||||||||
without |
14 VDC |
10 |
6 |
|
3 |
10 |
|
|
6 |
|
||
indicator) |
30 VDC |
|
6 |
4 |
|
3 |
6 |
|
|
4 |
|
|
|
125 VDC * |
|
0.8 |
0.2 |
|
0.2 |
0.8 |
|
0.2 |
|||
|
250 VDC * |
|
0.4 |
0.1 |
|
0.1 |
0.4 |
|
0.1 |
|||
|
125 VAC |
|
5 |
|
2 |
|
|
4 |
|
|
3 |
|
DPDT |
250 VAC |
|
3 |
|
1 |
|
|
2 |
|
|
1.5 |
|
480 VAC |
|
1.5 |
0.5 |
1 |
|
|
0.8 |
|||||
double- |
|
|
|
|||||||||
600 VAC |
|
1 |
|
0.4 |
0.7 |
|
0.5 |
|||||
break |
|
|
|
|||||||||
14 VDC |
|
5 |
|
2 |
|
|
4 |
|
|
3 |
|
|
(without |
|
|
|
|
|
|
|
|||||
30 VDC |
|
3 |
|
1 |
|
|
2 |
|
|
1.5 |
||
indicator) |
|
|
|
|
|
|
||||||
125 VDC |
|
0.4 |
0.1 |
0.4 |
|
0.1 |
||||||
|
|
|
||||||||||
|
250 VAC |
|
0.2 |
0.05 |
0.2 |
|
0.05 |
|||||
DPDT |
125 VAC |
|
5 |
2 |
|
4 |
|
3 |
|
|||
double- |
250 VAC |
|
3 |
1 |
|
2 |
|
1.5 |
||||
break |
12 VDC |
5 |
|
|
|
|
|
|
|
|
|
|
(with in- |
24 VDC |
3 |
|
--- |
--- |
|
--- |
|
--- |
|||
dicator) |
48 VDC |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* For those with indicators, refer to the following rated voltages.
|
|
SPDT, Double-break |
DPDT, Double-break |
||
Item |
Type |
Without |
With indi- |
Without |
With indi- |
|
|
indicator |
cator |
indicator |
cator |
Inrush |
Normally closed |
30 A max. |
|
|
|
current |
Normally open |
20 A max. |
|
|
|
|
|
|
|
|
|
Note: 1. The above current ratings are for steady-state current.
2.Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.Lamp loads have an inrush current of 10 times the steady-state current.
4.Motor loads have an inrush current of 6 times the steady-state current.
Ratings for Indicators
Classi- |
Indicator |
Model |
Rated |
Leakage |
Internal |
|
fication |
voltage |
current |
resistance |
|||
|
|
|||||
SPDT |
Neon lamp |
D4A-0300N |
125 VAC, |
Approx. |
150 kΩ |
|
250 VAC |
0.47 mA |
|||||
double- |
|
|
|
|||
|
|
|
Approx. |
|
||
break |
LED |
D4A-0E00N |
24 VDC |
15 kΩ |
||
1.3 mA |
||||||
|
|
|
|
|
||
DPDT |
Neon lamp |
D4A-0L00N |
125 VAC, |
Approx. |
240 kΩ |
|
250 VAC |
0.28 mA |
|||||
double- |
|
|
|
|||
|
|
|
Approx. |
|
||
break |
LED |
D4A-0P00N |
48 VDC |
--- |
||
1.4 mA |
||||||
|
|
|
|
|
||
|
|
|
|
|
|
5