OM1840NKM OM1840SCM
OM1840NCM
5 AMP LOW DROPOUT POSITIVE ADJUSTABLE REGULATOR APPROVED TO DESC DRAWING 5962-89521
Three Terminal, Positive Adjustable
Low Dropout Voltage Regulator In
Hermetic Packages
FEATURES
•Similar To Industry Standard LT1084
•Approved To DESC Standardized Military Drawing Number 5962-89521
•Adjustable Output Voltage
•Built In Thermal Overload Protection
•Short Circuit Current Limiting
•Maximum Output Voltage Tolerance is Guaranteed To ±1%
•Guaranteed Dropout Voltage At Multiple Current Levels
•TO-258 Available in Isolated and Non-Isolated Packages
DESCRIPTION
This three terminal positive adjustable voltage regulator is designed to provide 5A with higher efficiency than conventional voltage regulators. This device is designed to operate down to 1 Volt input to output differential and the dropout voltage is fully specified as a function of load current. Supplied in easy-to-use hermetic TO-258 and TO-3 packages, this device is ideally suited for Military applications where small size and high reliability is required.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Power Dissipation (Pd) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited Input - Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C 3.3 Lead Temperature (Soldering 10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300°C
Thermal Resistance:
θJC (TO-258 Isolated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.0°C/W θJC (TO-258 Non-Isolated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3°C/W θJC (TO-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.0°C/W Maximum Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.0 A
Recommended Operating Conditions:
Output Voltage Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.3V to 15 V Ambient Operating Temperature Range (TA) . . . . . . . . . . . . . . . . - 55°C to + 125°C Input Voltage Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V to 25 V
1 08 R3 |
3.3 - 75 |
Supersedes 4 11 R2 |
OM1840SCM OM1840NCM OM1840NKM
ELECTRICAL CHARACTERISTICS -55°C ≤ TA ≤ +125°C (unless otherwise specified)
Parameter |
Symbol |
Test Conditions |
|
Min. |
Max. |
Unit |
||
|
|
|
|
|
|
|
|
|
Reference Voltage |
|
VREF |
VIN - VOUT = 3.0 V, |
|
1.238 |
1.262 |
V |
|
|
|
|
|
IOUT = 10 mA, TA = 25° C |
|
|
|
|
|
|
|
|
1.5 V ≤ VIN - VOUT ≤ 25 V, |
• |
1.225 |
1.270 |
V |
|
|
|
|
IOUT = 10 mA, IFL = 3.0 A |
|
|
|
|
Line Regulation |
|
∆VOUT |
|
1.5 V ≤ VIN - VOUT ≤ 15 V, |
|
|
0.2 |
% |
(Note 1) |
|
∆VIN |
IOUT = 10 mA, TA = 25° C |
|
|
|
|
|
|
|
|
|
15 V ≤ VIN - VOUT ≤ 35 V, |
• |
|
0.5 |
% |
|
|
|
|
IOUT = 10 mA |
|
|
|
|
Load Regulation |
|
∆VOUT |
|
VIN - VOUT = 3.0 V, TA = 25° C |
|
|
0.3 |
% |
(Note 1) |
|
∆IOUT |
IOUT = 10 mA, IFL = 3.0 A |
|
|
|
|
|
|
|
|
|
|
• |
|
0.4 |
% |
|
|
|
|
|
|
|
|
|
Dropout Voltage |
|
VDO |
IFL = 3.0 A, ∆VREF = 1% |
• |
|
1.5 |
V |
|
Thermal Regulation |
- |
|
30 ms pulse, TA = +25° C |
|
|
0.015 |
%/W |
|
Ripple Rejection |
|
∆VIN |
|
f = 120 Hz, CAdj = 25 µF, |
• |
60 |
|
dB |
|
|
∆VOUT |
COUT = 25 µF (tantalum), IFL = 3.0 A, |
|
|
|
|
|
|
|
|
|
VIN - VOUT = 3.0 V |
|
|
|
|
Adjust Pin Current |
|
IAdj |
1.5 V ≤ VIN - VOUT ≤ 25 V, |
• |
|
120 |
µA |
|
|
|
|
|
IOUT = 10 mA, IFL = 3.0 A |
|
|
|
|
Adjust Pin Current Change |
|
∆IAdj |
1.5 V ≤ VIN - VOUT ≤ 25 V, |
• |
|
5.0 |
µA |
|
|
|
|
|
10 mA ≤ IOUT ≤ 3.0 A |
|
|
|
|
Miminum Load Current |
|
IMin |
VIN - VOUT = 25 V |
• |
|
10 |
mA |
|
Current Limit |
|
ILim |
VIN - VOUT ≤ 5.0 V |
• |
5.5 |
|
A |
|
|
|
|
|
VIN - VOUT = 25 V |
• |
0.3 |
|
A |
Temperature Stability |
|
∆VOUT |
|
-55° C ≤ TJ ≤ +125° C |
• |
|
1.5 |
% |
(Note 2) |
|
∆T |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Long Term Stability |
|
∆VOUT |
|
TA = +125° C, t = 1000 hrs |
|
|
1.0 |
% |
(Note 2) |
|
∆T |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes:
1.Line and Load Regulation are measured at a constant junction temperature using a low duty cycle pulse technique. Although power dissipation is
internally limited, regulation is guaranteed up to the maximum power dissipation of 45 W. Power dissipation is determined by the input/output differential voltage and the output current. Guaranteed maximum power dissipation will not be available over the full input/output voltage range.
2.Guaranteed by design, characterization or correlation to other tested parameters.
3.The • denotes the specifications which apply over the full operating temperature range.
3.3 |
|
PART NUMBER DESIGNATOR |
|
||
|
Standard Military Drawing Number |
|
Omnirel Part Number |
|
|
|
|
8952101Y |
|
OM1840SCM |
|
|
|
8952101Z |
|
OM1840NCM |
|
|
|
8952101X |
|
OM1840NKM |
|
|
|
|
|
|
|
|
|
|
“Y” = Isolated |
|
“Z” = Non-Isolated
Part Numbering System
Voltage Regulators
OM-1840-S-C-M
Company |
|
|
Screening |
|||||||||||
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
M= MIL-M |
|||
Identification |
||||||||||||||
|
|
|
|
|
|
Part |
38535 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Number |
Package |
|||||||
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(see Package codes*) |
|||||
|
|
|
|
|
|
|
|
S= Isolated |
||||||
|
|
|
|
|
|
|
|
N= Non |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
isolated |
|
|
|
|
|
|
* Package Codes:
K= TO-204AA (TO-3) Z= TO-259AA (Z-Tab) C = TO-258AA
3.3 - 76