Omnirel OM1323SMM, OM1323NKM, OM1323NMM, OM1323NTM, OM1323STM Technical data

...
0 (0)
Omnirel OM1323SMM, OM1323NKM, OM1323NMM, OM1323NTM, OM1323STM Technical data

OM1322N2M

OM1322SMM

OM1322NMM

OM1322STM

 

OM1322NKM

OM1322NTM

OM1322N2M

1.5 AMP NEGATIVE ADJUSTABLE VOLTAGE

REGULATOR APPROVED TO DESC DRAWING 7703403

Three Terminal, Precision Adjustable Negative Voltage Regulator In Hermetic

Style Packages (LM137)

Please see mechanical outlines herein

FEATURES

Similar To Industry Standard LM137

Approved To DESC Standardized Military Drawing Number 7703403

Built In Thermal Overload Protection

Short Circuit Current Limiting

Available In Six Package Styles

DESCRIPTION

These three terminal negative regulators are supplied in hermetically sealed packages. All protective features are designed into the circuit, including thermal shutdown, current-limiting, and safe-area control. With heat sinking, these devices can deliver up to 1.5 amps of output current. The LCC-20 device is limited to .5 amps. The unit also features output voltages that can be fixed from -1.2 volts to -37 volts using external resistors.

4 11 R2

Supersedes 1 07 R1

ABSOLUTE MAXIMUM RATINGS

 

T c

@ 25°C

 

 

Power Dissipation

 

 

 

 

 

Case 2 . . . . . . . . . . . . . . . . . . . . . .

. .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 W

 

Case-All Others. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20 W

 

Input - Output Voltage Differential . . . . . . . .

. .

. . . . . . . . . . .

. . . . . . . . . . . . . . . 40 V

 

Operating Junction Temperature Range . . . . . . .

. .

. . . . . . . . . . . .

- 55°C to + 150°C

 

 

Storage Temperature Range . . . . . . . . . . . . . .

. .

. . . . . . . . . . . .

. . - 65°C to + 150°C

 

 

Lead Temperature (Soldering 10 seconds) . . . . . . .

. .

. . . . . . . . . . . .

. . . . . . 300°C

 

 

Thermal Resistance, Junction to Case:

 

 

 

 

 

Case 2, LCC-20 . . . . . . . . . . . . . . . . .

. .

. . . . . . . . . . . .

. . . . . . . . . . . . . . 17°C/W

 

Case U & M, TO-257 (Isol) and SMD-3 . . . .

. .

. . . . . . . . . . . .

. . . . . . . . 4.2°C/W

 

 

.Case T&N, TO-257 (Non-Isol) and SMD-1

. . . . . . . . . . . . . . . . . . . . . . 3.5°C/W

 

3.5

Case Y, TO-3

 

 

3.0°C/W

. . .

. . . . . . . . . . . .

 

Maximum Output Current:

 

 

 

 

 

Case 2 . . . . . . . . . . . . . . . . . . . . . .

. .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 A

 

Case-All Others. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.5A

 

Recommended Operating Conditions:

 

 

 

 

 

Output Voltage Range . . . . . . . . . . . . .

. .

. . . . . . . . . . . . .

. . . . . . .-1.2 to -37 VDC

 

 

Ambient Operating Temperature Range (T

 

A ) . . . .

. . . . . . . . . . . - 55°C to + 125°C

 

Input Voltage Range . . . . . . . . . . . . . .

. .

. . . . . . . . . . . .

. . . . -4.25 to -41.25 VDC

 

 

 

3.5 - 9

 

 

 

OM1322NTM, OM1322STM, OM1322NKM, OM1322SMM, OM1322NMM, OM1322N2M

ELECTRICAL CHARACTERISTICS

-55°C ≤ T A ≤ 125°C, I L = 8mA (unless otherwise specified)

OM1322NTM, OM1322STM, OM1322NKM, OM1322SMM, OM1322NMM

Parameter

Symbol

 

 

Test Conditions

 

 

 

 

 

 

Min.

 

Max.

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference Voltage

V

 

REF

 

VDIFF

= 3.0V, T

A

= 25°C

 

-1.275

-1.225

 

 

 

 

 

 

 

 

VDIFF

 

= 3.0V

 

-1.30

-1.20

V

 

 

 

 

 

VDIFF

= 40V, T

A

= 25°C

 

-1.275

-1.225

 

 

 

 

 

 

 

 

VDIFF

 

= 40V

 

-1.30

-1.20

 

Line Regulation

R

 

LINE

3.0 V ≤

VDIFF

≤ 40V, T A = 25°C

 

-9

9

 

(Note 1)

 

 

 

 

 

3.0 V ≤

VDIFF ≤ 40V

 

-23

23

mV

 

 

 

 

 

 

 

 

 

 

 

Load Regulation

R

 

LOAD

VDIFF

= 5.0V, 8mA ≤ I

L ≤ 1.5A

-25

25

 

(Note 1)

 

 

 

VDIFF

= 12V, 8mA ≤ I

 

L ≤ 1.5A, T

A = 25°C

 

-25

25

mV

 

 

 

 

VDIFF

= 40V, 8mA ≤ I

 

L

≤ 200mA, T

A = 25°C

 

-25

25

 

 

 

 

 

VDIFF

= 40V, 8mA ≤ I

L ≤ 100mA

-25

25

 

Thermal Regulation

V

 

RTH

 

 

Vin = -14.6V, I

L

= 1.5A

 

 

-5

5

mV

 

 

 

 

P d

= 20 Watts, t = 10 ms, T

 

A

= 25°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ripple Rejection

 

R

N

 

 

f = 120 Hz, V out

= Vref

 

66

 

dB

(Note 2)

 

 

 

 

 

 

C

Adj = 10 µF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment Pin Current

I

 

Adj

 

 

 

VDIFF

 

= 3.0V

 

 

100

 

 

 

 

 

 

 

 

VDIFF

 

= 40V

 

 

100

µA

Adjustment Pin

∆I

 

Adj (Line)

 

 

3.0V ≤

VDIFF

≤ 40V

 

-5

5

µA

Current Change

∆I

 

Adj (Load)

 

VDIFF = 5V, 8mA ≤ I

L ≤ 1.5A

-5

5

µA

 

 

 

 

 

 

 

 

 

 

 

 

 

Miminum Load Current

I

 

Lmin

VDIFF

 

= 3.0V, V

out

= -1.4V (forced)

 

3.0

 

 

 

 

 

VDIFF

 

= 10V, V

out

 

= -1.4V (forced)

 

3.0

mA

 

 

 

 

VDIFF

 

= 40V, V out

 

= -1.4V (forced)

 

5.0

 

Current Limit

I

CL

 

 

 

VDIFF

 

≤ 5V

 

1.5

3.5

 

(Note 2)

 

 

 

 

VDIFF

= 40V, T

A

= 25°C

 

0.24

1.2

A

Notes:

1.Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.

2.If not tested, shall be guaranteed to the specified limits.

3.The denotes the specifications which apply over the full operating temperature range.

 

 

 

PART NUMBER DESIGNATOR

 

 

 

Standard Military Drawing Number

Omnirel Part Number

Omnirel Package Designation

 

 

 

 

 

 

 

3.5

 

7703403M

 

OM1322SMM

SMD-3

 

7703403U

 

OM1322STM

TO-257 (Isolated)

 

 

7703403T

 

OM1322NTM

TO-257 (non-Isolated)

 

 

7703403Y

 

OM1322 NKM

TO-3

 

 

7703403N

 

OM1322NMM

SMD-1

 

 

77034032

 

OM1322N2M

LCC-20

 

 

 

 

 

 

3.5 - 10

Loading...