OMNIREL OMR7812NM, OMR7812SR, OMR7805NM, OMR7805NH, OMR7815ST Datasheet

...
0 (0)
300K Rad T olerant Three T erminal, Positive Fixed Voltage Regulators In Hermetic Packages
300 kRAD RADIATION TOLERANT 1.5 AMP POSITIVE FIXED VOLTAGE REGULATORS
OMR7805NH OMR7812NH OMR7815NH
OMR7805ST OMR7812ST OMR7815ST
OMR7805SR OMR7812SR OMR7815SR
Please see mechanical
outlines herein
0 04 R1 Supersedes 9 12 R0
FEATURES
• Isolated & Non-Isolated Hermetic Packages
• Output Voltages: +5V, +12V, +15V (Other Voltages Available)
• Output Voltages Set Internally To ±1% or ±2%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Radiation Tolerant up to 450 K Rad (Si)
• Available Hi-Rel Screened, Class B and Class S, MIL-STD-883
DESCRIPTION
These three terminal negative regulators are supplied in a high density hermetically sealed metal package and are available hi-rel screened. All protective features are designed into the circuit, including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages to ±1% or 2% of nominal voltage. Standard voltages are +5V, +12V, and +15V. However, other voltages are available up to +24 volts. These devices are ideally suited for Space applications where small size, high reliability, and radiation tolerance is required. The high level of Radiation Tolerance of these devices makes them a desirable choice for LEO and many MEO and GEO communication satellites. Radiation testing is performed on a single wafer by wafer basis. Random die samples per wafer are selected, packaged and radiation tested to qualify each individual semiconductor wafer-by-wafer.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input V oltage . ................................................................-35 V
Operating Junction Temperature Range ............................ - 55°C to + 150°C
Storage Temperature Range ....................................... - 65°C to + 150°C
Power Dissipation:TO-205. ......... ....................................1.1 W
TO-257/SMD-1/ D2Pac ....................... ......................... 20 W
Lead Temperature (Soldering 10 seconds).......... .........................300°C
Surface Mount P ac kage Soldering Temperature.......... ....................250°C Thermal Resistance, Junction to Case:
TO-205.......... ...................................................17°C/W
TO-257(Isolated), D2Pac (Isolated) ..............................4.2°C/W
SMD-1 . ................................................3.5°C/W
Maximum Output Current: TO-205 .. . . .... ..........................0.5 A
TCase-All Others . ...................................................3.3A
Radiation Tolerant - Total Dose . ...................................300 K Rad (Si)
ELECTRICAL CHARACTERISTICS 12 Volt V
IN
= 19V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C 11.88 12.12 V
V
IN
= 14.5V to 27V 11.64 12.36 V
Line Regulation V
RLINE
VIN= 14.5V to 27V 18 mV
(Note 1)
50 mV
V
IN
= 16V to 22V 9 mV
30 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 32 mV
(Note 1)
60 mV
I
O
= 250mA to 750 mA 20 mV
40 mV
Standby Current Drain I
SCD
6.0 mA
6.5 mA
Standby Current Drain ∆I
SCD
V
IN
= 15V to 30V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
= 1.0A 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= 35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= 10V 61 dB
V
OUT
(Note 3) 54 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 120 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
4. The • denotes the specifications which apply over the full operating temperature range.
5. Refer to curves for typical characteristics versus Total Dose Radiation Levels.
ELECTRICAL CHARACTERISTICS 5 Volt V
IN
= 10V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C 4.92 5.08 V
V
IN
= 7.5V to 20V
4.85 5.15 V
Line Regulation V
RLINE
VIN= 7.5V to 20V 5 mV
(Note 1)
12 mV
V
IN
= 8.0V to 12V 4 mV
10 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 12 mV
(Note 1)
25 mV
I
O
= 250mA to 750 mA 6 mV
15 mV
Standby Current Drain I
SCD
6mA
6.5 mA
Standby Current Drain ∆I
SCD
V
IN
= 7.5V to 20V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
TA= 25°C, ∆V
OUT
= 100mV, I
O
= 1.0A 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= 35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= 10V 66 dB
V
OUT
(Note 3) 60 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 75 mV
(Note 3) ∆t
OMR7805NH OMR7812NH OMR7815NH
OMR7805ST OMR7812ST OMR7815ST
OMR7805SR OMR7812SR OMR7815SR
RADIA TION TEST PROGRAM
The following chart is a summary of the test data collected on Radiation Tolerant OMR7805/12/15 at various doses. The chart depicts the Total Radiation Dose that each device was e xposed to on a step stress irradiation basis prior to failure. Failure is defined as any electrical test that does not meet the limits of the device per the published data sheet specifications after radiation testing.
Omnirel P/N 5K 10K 20K 30K 50K 60K 70K 80K 100K 150K 200 250 300 350 400 450 KRAD OMR7805/12/15
Test Points X X X X X X
ELECTRICAL CHARACTERISTICS 15 Volt V
IN
= 23V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C 14.8 15.2 V
V
IN
= 18.5V to 30V
14.6 15.4 V
Line Regulation V
RLINE
VIN= 17.5V to 30V 20 mV
(Note 1)
50 mV
V
IN
= 20V to 26V 15 mV
25 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 35 mV
(Note 1) I
O
= 5mA to 1.0 Amp 75 mV
I
O
= 250mA to 750 mA 21 mV
45 mV
Standby Current Drain I
SCD
6.0 mA
6.5 mA
Standby Current Drain ∆I
SCD
V
IN
= 18.5V to 30V
0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
TA= 25°C, ∆V
OUT
= 100mV, I
O
=
1.0A 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= 35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= 10V 54 dB
V
OUT
(Note 3) 52 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long T erm Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 150 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
4. The • denotes the specifications which apply over the full operating temperature range.
5. Refer to curves for typical characteristics versus Total Dose Radiation Levels.
OMR7805NH OMR7812NH OMR7815NH
OMR7805ST OMR7812ST OMR7815ST
OMR7805SR OMR7812SR OMR7815SR
Loading...
+ 5 hidden pages