7.5 AMP LOW DROPOUT POSITIVE ADJUSTABLE REGULATOR APPROVED TO DESC DRAWING 5962-89520

Three Terminal, Positive Adjustable

Low Dropout Voltage Regulator In

Hermetic JEDEC TO-258AA Package

FEATURES

Similar To Industry Standard LT1083

Approved To DESC Standardized Military Drawing Number 5962-8952001Y

Adjustable Output Voltage

Built In Thermal Overload Protection

Short Circuit Current Limiting

Available In Isolated Package

Maximum Output Voltage Tolerance is Guaranteed To ±1%

Guaranteed Dropout Voltage At Multiple Current Levels

Product Also Available in Non-Isolated Package

DESCRIPTION

This three terminal positive adjustable voltage regulator is designed to provide 7.5A with higher efficiency than conventional voltage regulators. This device is designed to operate down to 1 volt input to output differential and the dropout voltage is fully specified as a function of load current. Supplied in easy-to-use hermetic TO-258 package, this device is ideally suited for Military applications where small size and high reliability is required.

ABSOLUTE MAXIMUM RATINGS @ 25°C

3.3

 

Power Dissipation (Pd) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited Input - Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V

Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C Lead Temperature (Soldering 10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300°C Thermal Resistance:

qJC (Isolated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.75°C/W qJC (Non-Isolated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3°C/W Maximum Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5 A

4 11 R1

3.3 - 69

Supersedes 1 06 R0

OM1830SCM OM1830NCM

ELECTRICAL CHARACTERISTICS -55°C TA +125°C (unless otherwise specified)

Parameter

Symbol

Test Conditions

 

Min.

Max.

Unit

 

 

 

 

 

 

 

 

 

Reference Voltage

 

VREF

VIN - VOUT Œ= 3.0 V,

 

1.238

1.262

V

 

 

 

 

IOUT = 10 mA, TA = 25° C

 

 

 

 

 

 

 

 

1.5 V

VIN - VOUT Π25 V,

1.225

1.270

V

 

 

 

 

10 mA IOUT 5.0 A

 

 

 

 

Line Regulation

 

³VOUT

 

1.5 V

VIN - VOUT Π15 V,

 

 

0.2

%

(Note 1)

 

³VIN

IOUT = 10 mA, TA = 25° C

 

 

 

 

 

 

 

 

15 V

VIN - VOUT Π35 V,

 

0.5

%

 

 

 

 

 

IOUT = 10 mA

 

 

 

 

Load Regulation

 

³VOUT

 

VIN - VOUT Œ= 3.0 V, TA = 25° C

 

 

0.3

%

(Note 1)

 

³IOUT

10 mA IOUT 5.0 A

 

 

 

 

 

 

 

 

 

 

 

0.4

%

Dropout Voltage

 

VDO

IOUT = IFL, IFL = 5.0 A, ³VREF = 1%

 

1.5

V

Thermal Regulation

-

 

30 ms pulse, TA = +25° C

 

 

0.01

%/W

Ripple Rejection

 

³VIN

f = 120 Hz, CAdj = 25 µF,

60

 

dB

 

 

 

 

 

 

 

 

 

 

 

³VOUT

COUT = 25 µF (tantalum), IFL = 5.0 A,

 

 

 

 

 

 

 

 

VIN - VOUT Œ= 3.0 V, IOUT = IFL

 

 

 

 

Adjust Pin Current

 

IAdj

1.5 V

VIN - VOUT Π25 V

 

120

µA

 

 

 

 

10 mA IOUT 5.0 A

 

 

 

 

Adjust Pin Current Change

 

³IAdj

1.5 V

VIN - VOUT Π25 V

 

5.0

µA

 

 

 

 

10 mA IOUT 5.0 A

 

 

 

 

Miminum Load Current

 

IMin

VIN - VOUT Œ= 25 V

 

10

mA

Current Limit

 

ILim

VIN - VOUT Œ= 5.0 V

8.0

 

A

 

 

 

 

VIN - VOUT Œ= 25 V

0.4

 

A

Temperature Stability

 

³VOUT

 

-55° C TJ +125° C

 

1.5

%

(Note 2)

 

³T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Long Term Stability

 

³VOUT

 

TA = +125° C, t = 1000 hrs

 

 

1.0

%

(Note 2)

 

³T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.Line and Load Regulation are measured at a constant junction temperature using a low duty cycle pulse technique. Although power dissipation is internally limited, regulation is guaranteed up to the maximum power dissipation of 60 W. Power dissipation is determined by the input/output differential voltage and the output current. Guaranteed maximum power dissipation will not be available over the full input/output voltage range.

3.32. Guaranteed by design, characterization or correlation to other tested parameters.

3.The • denotes the specifications which apply over the full operating temperature range.

PART NUMBER DESIGNATOR

Standard Military Drawing Number

Omnirel Part Number

8952001Y

OM1830SCM

8952001Z

OM1830NCM

“Y” = Isolated

3.3 - 70