Nortel Networks OPTera Metro 3500, NTRN10AN User Manual

4 (1)

NTRN10AN

Nortel Networks

OPTera Metro 3500

Multiservice Platform

Release 12.1 Planning and Ordering

Guide—Part 1 of 2

Standard Issue 1 April 2004

What’s inside...

Overview

Operation, administration, and maintenance (OAM) features Hardware feature descriptions

See Part 2 for the following...

Technical specifications

Engineering rules

Cable and connector details

Shelf mounting guidelines

Ordering information

Terms and conditions

Glossary

*A0549426*

Copyright 2000–2004 Nortel Networks, All Rights Reserved

The information contained herein is the property of Nortel Networks and is strictly confidential. Except as expressly authorized in writing by Nortel Networks, the holder shall keep all information contained herein confidential, shall disclose the information only to its employees with a need to know, and shall protect the information, in whole or in part, from disclosure and dissemination to third parties with the same degree of care it uses to protect its own confidential information, but with no less than reasonable care. Except as expressly authorized in writing by Nortel Networks, the holder is granted no rights to use the information contained herein.

Nortel Networks, the Nortel Networks logo, the Globemark, OPTera, and Preside are trademarks of Nortel Networks. ACE/Server, RSA, and SecurID are trademarks of RSA Security Inc.

Hewlett-Packard, HP, and HP-UX are trademarks of Hewlett-Packard Company. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation.

Solaris, Sun, Sun Blade, Sun Microsystems, and Ultra are trademarks of Sun Microsystems, Inc.

SPARC is a trademark of SPARC International Inc. Telcordia, TIRKS, and NMA are trademarks of Telcordia Technologies, Inc. Pentium is a trademark of Intel Corporation.

Printed in Canada

 

 

 

 

iii

 

 

 

 

 

Contents

 

 

 

 

 

 

 

About this document

ix

 

Supported software

ix

 

 

 

Supported hardware

x

 

 

 

Technical support and information xii

 

 

 

 

 

 

 

Overview

 

 

1-1

 

Network element overview

1-1

 

 

Release 12.1 features 1-4

 

 

Release 12.1 Hardware Compatibility Matrix 1-16

 

 

Supported configurations

1-19

 

 

Interworking 1-25

 

 

 

 

Supported upgrade paths

1-26

 

 

 

 

 

Operation, administration, and maintenance (OAM) features

2-1

 

Gigabit Ethernet Drop and Continue 2-3

 

 

Alarm provisioning 2-5

 

 

 

Alarm flow control

2-6

 

 

 

Environmental alarms

2-7

 

 

External controls

2-7

 

 

ACO switch — clearing audible alarms and performing lamp tests 2-7

Bandwidth management

2-7

 

 

 

Tributary, DWDM, BLSR, UPSR, and 1+1 linear point-to-point

2-8

BLSR 2-9

 

 

 

 

Connection editing 2-9

 

 

 

In-service traffic rollover 2-9

 

 

 

BLSR networks (2-fiber)

2-10

 

 

 

Protection 2-11

 

 

 

 

’Infinite wait-to-restore’

parameter 2-12

 

 

BLSR Line Protection Oscillation Control

2-13

 

BLSR single span fiber cut scenario 2-13

 

 

BLSR nodal / multi-span failure scenario (involves squelching)

2-25

BLSR configurations 2-29

 

 

 

BLSR configuration and connection audit

2-30

 

Traffic flow over OC-48 BLSR

2-31

 

 

Traffic flow over OC-192 BLSR

2-32

 

 

Provisioning rules 2-34

 

 

 

OAM supported on BLSR 2-43

Channelized DS3 service (DS3VTx12 mapper) 2-44

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

iv Contents

Common Language Location Identifier

2-44

 

Connection ID

2-45

 

 

 

 

 

Consolidated load

2-45

 

 

 

 

Dense wavelength division multiplexing (DWDM) 2-46

 

OMX module

2-48

 

 

 

 

Network sites

2-49

 

 

 

 

DWDM configurations

2-50

 

 

 

Facility attributes

2-54

 

 

 

 

Loopbacks 2-54

 

 

 

 

 

 

 

Terminal loopback

2-54

 

 

 

Facility loopback

 

2-54

 

 

 

 

Optical loopback

 

2-55

 

 

 

 

Network surveillance

2-58

 

 

 

Extended network processor (NPx)

2-58

 

Telemetry byte-oriented serial (TBOS)

2-59

 

Path trace

2-60

 

 

 

 

 

 

Section trace

2-61

 

 

 

 

TID address resolution protocol (TARP)

2-61

 

OPTera Packet Edge System (Resilient Packet Ring) - Ethernet 2-62

 

Connectors

2-62

 

 

 

 

 

Resilient packet ring (RPR) object 2-63

 

Optical Ethernet / Layer 2 (OE/L2) on OPTera Packet Edge System

2-64

RPR configuration alert

2-65

 

 

 

Auto save notification 2-65

 

 

 

NNI Filters increased to 2048 2-66

 

 

 

Optical Ethernet-Private Line (OE-PL) services using 10/100 Ethernet

2-66

2x100BT-P2P circuit pack 2-66

 

 

 

PPP over SONET

2-67

 

 

 

PPP and HDLC

2-67

 

 

 

 

Bridge Control Protocol

2-69

 

 

 

Network protection using UPSR, 1+1 linear and BLSR 2-69

 

OAMP support

 

2-70

 

 

 

 

Ethernet Operational Measurements

2-70

 

Optical Ethernet-Private Line (OE-PL) service using 2x1000 SX/LX OPE circuit

packs 2-71

 

 

 

 

 

Distributed multilink trunking

2-72

 

 

Bandwidth Reservation Protocol (BRP) 2-72

 

1024 TDIs on a mapped UNI

2-72

 

 

Optical Ethernet - Private Line (OE-PL) and Storage applications

2-73

2xGigE/FC-P2P circuit pack

2-73

 

 

Alarm management 2-74

 

 

 

Bandwidth management

2-84

 

 

Facility attributes

2-85

 

 

 

 

Ethernet Operational Measurements 2-90

 

 

Performance Monitoring

2-95

 

 

Fibre Channel Extended Reach 2-95

 

 

Generic Framing Procedure and Virtual Concatenation support

2-99

Optical interoperability of OPTera Metro 3500

2-102

 

Performance monitoring 2-102

 

 

 

SONET line, section, and path parameters

2-102

 

Threshold values

2-103

 

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Contents v

Retrieving performance monitoring counts

2-110

 

 

 

Physical PMs

2-111

 

 

 

 

 

 

 

 

Performance monitoring threshold crossing alerts (TCA)

2-114

 

TCAs 2-114

 

 

 

 

 

 

 

 

 

 

TCA summary alarms

2-114

 

 

 

 

 

 

Site Manager support

2-116

 

 

 

 

 

 

Preside Software Upgrade Management support 2-116

 

 

Preside Applications Platform and Multiservice MOA support

2-117

 

Protection switching

2-118

 

 

 

 

 

 

 

Protection hierarchy 2-119

 

 

 

 

 

 

Protection performance monitoring parameters for optical facilities 2-120

Security and administration

2-122

 

 

 

 

 

Local account user authentication 2-122

 

 

 

 

Local ‘challenge-response’ user authentication 2-123

 

 

Centralized Security Administration (CSA)

2-124

 

 

 

Centralized user administration and authentication through RADIUS

2-125

SecurID support 2-128

 

 

 

 

 

 

 

Secure storage of authentication data

2-128

 

 

 

Saving and restoring provisioning data

2-129

 

 

 

Local TL1 of provisioning data

2-129

 

 

 

 

 

Save and restore of shelf processor or span of control data to a remote

management entity through an IP connection

2-129

 

 

Application of TL1 commands from a TL1 script file

2-130

 

Security levels

2-130

 

 

 

 

 

 

 

 

Third Level 5 User Support/Increased NPx SOC visibility to 16 NEs

2-131

System identifier (SID)

2-131

 

 

 

 

 

 

Remote login

2-132

 

 

 

 

 

 

 

 

Multiple login sessions

2-132

 

 

 

 

 

 

Enhanced Intrusion Detection

2-133

 

 

 

 

 

Intrusion attempt handling

2-134

 

 

 

 

 

Password management

2-135

 

 

 

 

 

 

Customer managed networks

2-137

 

 

 

 

 

Security log audit trail

2-138

 

 

 

 

 

 

General Broadcast tool

2-139

 

 

 

 

 

 

Modifiable Login Banner

2-140

 

 

 

 

 

STS Managed DSM

2-142

 

 

 

 

 

 

 

Support for 12 DSM

2-146

 

 

 

 

 

 

 

Synchronization

2-146

 

 

 

 

 

 

 

 

Internal timing

2-147

 

 

 

 

 

 

 

 

External timing

2-147

 

 

 

 

 

 

 

 

Line timing

2-147

 

 

 

 

 

 

 

 

 

Timing modes

2-149

 

 

 

 

 

 

 

 

Stratum clocks

2-150

 

 

 

 

 

 

 

 

Synchronization hierarchy

2-150

 

 

 

 

 

Hierarchy violations 2-151

 

 

 

 

 

 

Timing loops

2-151

 

 

 

 

 

 

 

 

Building-integrated timing supply (BITS)

2-153

 

 

 

Network element synchronization modes

2-153

 

 

 

Timing sources and timing distribution

2-155

 

 

 

External timing reference input signals to STX and VTX-series circuit packs 2-156

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

vi Contents

Synchronization-status messages 2-156

 

 

User-specified quality levels for timing sources 2-158

 

 

BITS output with VTX-series or STX-192 circuit packs 2-158

 

User-initiated synchronization switches

2-158

 

 

Test Access 2-160

 

 

 

 

Test Access Ports (TAPs)

2-161

 

 

 

Test access configurations

2-162

 

 

 

Monitoring test access 2-162

 

 

 

Split test access 2-165

 

 

 

 

Loss of association and auto recovery

2-167

 

 

User interface 2-168

 

 

 

 

Time of day synchronization

2-169

 

 

 

TL1 Changes to Cross Connect AID parameter 2-172

 

 

TL1 event exerciser 2-173

 

 

 

 

TL1 event / log feature 2-173

 

 

 

Database change events

2-174

 

 

 

Log events 2-174

 

 

 

 

Inventory events 2-174

 

 

 

 

ATAG sequence numbers

2-175

 

 

 

Topology enhancements 2-175

 

 

 

VT management option on STX equipped OPTera Metro 3500

2-175

 

VT management on a UPSR 2-175

 

 

 

VT grooming on a UPSR

2-181

 

 

 

Collocated OPTera Metro 3000 NE and dedicated STS at each site

2-184

Collocated OPTera Metro 3000 NE and shared VT-managed STS

2-186

UPSR planning guidelines summary 2-189

 

 

General guidelines 2-189

 

 

 

 

Physical subtending rings

2-189

 

 

 

Virtual rings across the STS-managed OPTera Metro 3500 backbone

network 2-189

 

 

 

 

VT grooming at an STS-managed OPTera Metro 3500 site

2-189

 

 

 

 

 

 

Hardware feature descriptions

 

 

3-1

Extended Reach (ZX) Small Form Factor Pluggable (SFP)

3-3

 

OPTera Metro 3500 Shelf and the OPTera Metro 3500 Universal Shelf

3-4

Shelves equipped with VTX-48 or VTX-48e circuit packs

3-4

 

Shelves equipped with STX-192 circuit packs

3-5

 

 

Replaceable I/O modules 3-26

 

 

 

 

Common modules

3-37

 

 

 

 

Left OAM (LOAM)

3-37

 

 

 

 

Left interface (LIF)

3-38

 

 

 

 

OPTera Metro 3500 cooling unit assembly and cooling unit fan modules

3-40

Universal cooling unit assembly and cooling unit fan modules for extended

temperature applications

3-41

 

 

 

20 A (Universal) power module

3-42

 

 

 

OPTera Metro 3000 breaker interface panel (BIP)

3-42

 

 

OPTera Metro 3500 BIP (European deployment)

3-44

 

 

STX-192 circuit pack

3-51

 

 

 

 

Equipping rules

3-51

 

 

 

 

VTX-48 circuit pack

 

3-54

 

 

 

 

Equipping rules

3-55

 

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Contents vii

VTX-48e circuit pack

3-55

 

 

 

Equipping rules

3-56

 

 

 

Extended shelf processor (SPx)

3-56

 

TL1 sessions

3-56

 

 

 

 

Alarms and TBOS

3-57

 

 

 

Reset button

3-57

 

 

 

 

Section data communication channel (SDCC)

3-57

Equipping rules

3-57

 

 

 

Extended network processor (NPx)

3-57

 

TL1 sessions

3-58

 

 

 

 

Alarms and provisioning data

3-58

 

Reset button

3-58

 

 

 

 

Equipping rules

3-59

 

 

 

ILAN interface

3-59

 

 

 

 

Equipping rules

3-59

 

 

 

OC-192 optical interface circuit pack 3-59

 

STS-1 path trace for OC-192

3-60

 

Section trace for OC-192 3-60

 

 

Section data communication channel (SDCC)

3-60

Forward Error Correction (FEC)

3-60

 

Equipping rules

3-62

 

 

 

OC-192 protection switching

3-62

 

OC-192 DWDM G.709 FEC optical interface circuit pack 3-64

Section data communication channel (SDCC)

3-64

Forward Error Correction (FEC)

3-64

 

Equipping rules

3-65

 

 

 

 

OC-48 optical interface circuit pack

3-65

 

STS-1 path trace for OC-48

3-65

 

Section trace for OC-48

3-66

 

 

Section data communication channel (SDCC)

3-66

Equipping rules

3-66

 

 

 

 

OC-48 protection switching

3-67

 

OC-48 STS optical interface circuit pack 3-68

 

STS-1 path trace for OC-48

3-69

 

Section trace for OC-48

3-69

 

 

Section data communication channel (SDCC)

3-69

Equipping rules

3-70

 

 

 

 

OC-48 protection switching

3-70

 

OC-48 DWDM circuit pack

3-71

 

 

Section data communication channel (SDCC)

3-71

Equipping rules

3-72

 

 

 

 

OC-12 optical interface circuit pack

3-72

 

Equipping rules

3-73

 

 

 

 

OC-12 Protection switching

3-73

 

Section data communication channel (SDCC)

3-74

OC12x4 STS IR optical interface circuit pack 3-75

Multimode Interworking

3-75

 

 

Equipping rules

3-76

 

 

 

 

Section data communication channel (SDCC)

3-77

OC-3 optical interface circuit pack

3-77

 

Equipping rules

3-78

 

 

 

 

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

viii Contents

OC-3 Protection switching 3-78

 

 

Section data communication channel (SDCC)

3-79

OC-3x4 optical interface circuit pack 3-80

 

 

Multimode Interworking 3-80

 

 

Equipping rules

3-81

 

 

Section data communication channel (SDCC)

3-82

EC-1x3 circuit pack

3-82

 

 

Equipping rules

3-83

 

 

Protection switching 3-83

 

 

Section data communication channel (SDCC)

3-83

EC-1x12 circuit pack 3-84

 

 

Equipping rules

3-84

 

 

Protection switching 3-85

 

 

Section data communication channel (SDCC)

3-85

DS1 mapper 3-86

 

 

 

Equipping rules

3-86

 

 

DS3x3 mapper 3-87

 

 

Equipping rules

3-87

 

 

Protection switching 3-88

 

 

DS3x12 / DS3x12e mapper 3-89

 

 

Equipping rules

3-89

 

 

DS3VTx12 mapper

3-90

 

 

Equipping rules

3-91

 

 

DS3/VT protection switching 3-91

 

 

2x100BT-P2P circuit pack 3-91

 

 

Equipping rules

3-92

 

 

OPTera Packet Edge System 4x100BT circuit pack

3-94

Equipping rules

3-94

 

 

OPTera Packet Edge System 4x100FX circuit pack

3-96

Equipping rules

3-96

 

 

OPTera Packet Edge System 2xGigE (2x1000SX, 2x1000LX) circuit pack 3-97

Equipping rules

3-97

 

2xGigabit Ethernet/Fibre Channel - Point-to-Point circuit pack 3-98

Equipping rules

3-98

 

Protection switch controller (PSC)

3-100

Equipping rules

3-100

 

Protection switch extender (PSX)

3-101

Equipping rules

3-101

 

OMX + Fiber Manager 4CH 3-101 Enhanced OMX + Fiber Manager 4CH 3-102

OMX shelf (not required with OMX + Fiber Manager 4CH) 3-103 Equipping rules 3-103

Fiber Manager (not required with OMX + Fiber Manager 4CH) 3-104 DS1 service module (DSM) shelf 3-107

Equipping rules 3-107 Multiple IS 3-107

DSM DS1x84 termination module (TM) 3-111 Equipping rules 3-111

Protection switching 3-112

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

ix

About this document

ATTENTION

This document is presented in two parts: Part 1 and Part 2. Each part has its own table of contents. The table of contents in Part 1 contain topics found in Part 1 only. The table of contents in Part 2 contain topics found in Part 2 only. Part 2 continues sequential chapter numbering from Part 1.

You are reading Part 1 of Nortel Networks OPTera Metro 3500 Multiservice Platform Release 12.1 Planning and Ordering Guide, NTRN10AN.

Part 1 of OPTera Metro 3500 Multiservice Platform Release 12.1 Planning and Ordering Guide, NTRN10AN covers a network element overview and new features in Release 12.1, operation, administration, and maintenance (OAM) features, and hardware description features.

Part 2 of OPTera Metro 3500 Multiservice Platform Release 12.1 Planning and Ordering Guide, NTRN10AN covers technical specifications, engineering rules, cable and connector details, shelf mounting guidelines, ordering information, terms and conditions, and a glossary.

Standards

The Telecommunications Industry Association (TIA) and the Electronics Industries Alliance (EIA) accepted RS-232 as a standard in 1997 and renumbered this standard as TIA/EIA-232. In this document, RS-232 is used to reflect current labels on the hardware and in the software for the OPTera Metro 3500 Multiservice Platform.

Supported software

This document supports the software release for OPTera Metro 3500 Release 12.1.

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

x About this document

Supported hardware

This document supports the OPTera Metro 3500 shelves (NTN476AA, NTN476DA) and the Universal OPTera Metro 3500 shelf (NTN476AH).

Note: The OPTera Metro 3500 shelf NTN476AA must be upgraded using the power module and cooling upgrade kit (NTN458MW) to support OC-192 optical interfaces.

Hardware naming conventions

The following naming conventions are used throughout this document to identify the OPTera Metro 3500 hardware:

The extended shelf processor (SPx) is referred to as the shelf processor.

The extended network processor (NPx) is referred to as the network processor.

Audience

The following members of your company are the intended audience of this Nortel Networks technical publication (NTP):

planners

provisioners

network administrators

transmission standards engineers

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Nortel Networks OPTera Metro 3500, NTRN10AN User Manual

About this document xi

OPTera Metro 3500 NTP library

Guides and

TL1 Reference

Operations,

Shelf Setup

 

Administration

 

 

and Provisioning

About the

TL1 Reference

System

OPTera Metro 3500

(323-1059-190)

Reconfiguration

NTP Library

 

(323-1059-224)

(323-1059-090)

 

Security and

Planning and

 

 

Administration

Ordering Guide

 

(323-1059-302)

(NTRN10AN)

 

Provisioning

Network

 

 

Synchronization

Interworking Guide

 

(323-1059-310)

(NTCA68CA)

 

Protection

 

 

OPTera Metro 3500

 

Switching

Network

 

(323-1059-311)

InteroperabilityGuide

 

Bandwidth

(NTRN16AA)

 

 

 

Management

Installation

 

(323-1059-320)

(323-1059-201)

 

Provisioning

 

 

Commissioning

 

Equipment and

(323-1059-210)

 

Facilities

 

 

(323-1059-350)

System Testing

 

 

(323-1059-222)

 

 

 

EX1541p

Maintenance

Supporting

 

documentation

 

for the OPTera

 

Metro 3500

 

Library

 

Change Application

 

Procedures

 

(CAPs)

 

Data

 

Communications

 

Network Planning

 

Guide

 

(NTR710AM)

Performance

OPTera Metro

Monitoring

3000 series

(323-1059-510)

DWDM Application

Network

Guide

(NTRN12AA)

Surveillance

OPTera Packet Edge

(323-1059-520)

System Planning

 

Alarm and

Guide

Trouble Clearing

(NTRN10YK)

(323-1059-543)

OPTera Packet Edge

 

 

System Network

 

Applications and

 

Management

 

(NTRN11YK)

 

OPTera Packet Edge

 

System User Guide

 

(NTN465YG)

 

Site Manager

 

Planning and

 

Installation Guide,

 

Rel 6.0

 

(NTNM35FA)

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

xii About this document

Technical support and information

For technical support and information from Nortel Networks, refer to the following table.

Technical Assistance Service

For service-affecting problems:

North America:

For 24-hour emergency recovery or software upgrade

1-800-4NORTEL (1-800-466-7835)

support, that is, for:

 

• restoration of service for equipment that has been carrying

International:

traffic and is out of service

001-919-992-8300

 

• issues that prevent traffic protection switching

 

• issues that prevent completion of software upgrades

 

 

 

For non-service-affecting problems:

North America:

For 24-hour support on issues requiring immediate support

1-800-4NORTEL (1-800-466-7835)

or for 14-hour support (8 a.m. to 10 p.m. EST) on upgrade

Note: You require an express routing

notification and non-urgent issues.

code (ERC). To determine the ERC, see

 

 

our corporate Web site at

 

www.nortelnetworks.com. Click on the

 

Express Routing Codes link.

 

International:

 

Varies according to country. For a list of

 

telephone numbers, see our corporate

 

Web site at www.nortelnetworks.com.

 

Click on the Contact Us link.

 

 

Global software upgrade support:

North America:

 

1-800-4NORTEL (1-800-466-7835)

 

International:

 

Varies according to country. For a list of

 

telephone numbers, see our corporate

 

Web site at www.nortelnetworks.com.

 

Click on the Contact Us link.

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-1

Overview

Network element overview

The Nortel Networks OPTera Metro 3500 network element is a multiservice platform offering dense wavelength division multiplexing (DWDM) with a wide variety of services: DS1, DS3, Channelized DS3, EC-1, OC-3, OC-12, OC-48, OC-192, 10/100BASE-T Ethernet, 100BASE-FX Ethernet, Gigabit Ethernet and Fibre Channel.

OPTera Metro 3500 is a next generation SONET multiservice platform. It provides full OC-192 connectivity to customer premise locations.

On the physical layer (layer 1), an OPTera Metro 3500 network can be configured as a unidirectional path-switched ring (UPSR), a 1+1 linear configuration, a 2-fiber bidirectional line-switched ring (BLSR), or as an unprotected fiber optic run.

On the data link layer (layer 2), an OPTera Metro 3500 network can be configured as an OPTera Packet Edge ring with layer 2 protection, in accordance with Resilient Packet Rings (RPR) currently being defined by the IEEE 802.17 working group.

OPTera Metro Release 12.0 introduced a new STX-192 switch matrix circuit pack. The STX-192 circuit pack is a fully non-blocking STS switch matrix and clocking module providing switching capability for 40 Gbit/s. The STX-192 provides support for 10 Gbit/s links to the line slots 11 and 12 and up to 2.5 Gbit/s links to slots 3 through 10.

For STX based configurations, the OPTera Metro 3500 is optimized for broadband services, namely Gigabit Ethernet, Storage Area Networking, and switched Ethernet services using Resilient Packet Ring. When configured for STX based configurations, the platform supports full TDM services as well, with full fill OC12 and OC48 densities. Furthermore, DS1 services are still possible via the DS1 Service Module (DSM). For STX based configurations where VT1.5 level management is required, a dual node configuration can be used where by a VTX based OPTera Metro 3500 is subtended from a STX based OPTera Metro 3500. Both nodes are managed via Site Manager, which provides end-to-end connection management capability.

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-2 Overview

Figure 1-1

OPTera Metro 3500 slot assignments (STX-192 installed in shelf)

EX1470p

Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10

I/O module slots

LOAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIF

 

Empty

Tributary

Tributary

 

Tributary

Tributary

Tributary

Tributary

 

Tributary

 

Tributary

OC-48 STS or OC-192 (See Note)

 

 

OC-48 STS or OC-192 (See Note)

 

STX-192

 

 

STX-192

 

 

SPx

NPx or ILAN

Empty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pwr A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pwr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slot 1

Slot 2

Slot 3

 

Slot 4

 

Slot 5

Slot 6

Slot 7

Slot 8

 

Slot 9

 

Slot 10

 

Slot 11

 

 

Slot 12

 

Slot 13

 

 

Slot 14

 

 

Slot 15

Slot 16

Slot 17

 

 

 

 

 

 

 

Note: The OC-48 STS circuit pack is a single-width circuit pack.

For VTX based configurations, the OM3500 is optimized for OC48 based TDM and Optical Ethernet applications, supporting full densities for all TDM services. Furthermore, with the completely non-blocking VT1.5 switch matrix, the platform is ideally suited for hybrid digital cross connect and add/drop multiplexer applications.

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Overview 1-3

Figure 1-2

OPTera Metro 3500 slot assignments (VTX-48/VTX-48e installed in shelf)

EX1040p

Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10

I/O module slots

LOAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIF

 

PSC

Tributary

 

Tributary

 

Tributary

Tributary

Tributary

Tributary

 

Tributary

 

Tributary

OC-48 or OC-12 (See Note)

 

 

OC-48 or OC-12 (See Note)

 

VTX-48

 

 

VTX-48

 

 

SPx

NPx or ILAN

PSX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pwr A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pwr B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slot 1

Slot 2

Slot 3

Slot 4

 

Slot 5

Slot 6

Slot 7

Slot 8

 

Slot 9

 

Slot 10

 

Slot 11

 

 

Slot 12

 

Slot 13

 

 

Slot 14

 

 

Slot 15

Slot 16

Slot 17

 

 

 

 

 

 

 

 

 

Note: The OC-12 circuit pack is a single-width circuit pack.

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-4 Overview

Release 12.1 features

The Release 12.1 OPTera Metro 3500 system offers the following new and enhanced features:

Gigabit Ethernet Drop and Continue support on 2xGigE/FC-P2P interface

Support for extended reach (ZX) small-form factor pluggable (SFP)

This document describes the applications and functionality available in

Release 12.1. See the following chapters for more detail:

Chapter 1, Overview, gives a high level description of what is supported in this release.

Chapter 2, Operation, administration, and maintenance (OAM) features, gives a high level description of OAM&P functionality.

Chapter 3, Hardware feature descriptions, describes both shelves and their components.

Chapter 4, Technical specifications (in Part 2 of this guide), lists the technical specifications for all circuit packs and equipment.

Chapter 5, Engineering rules (in Part 2 of this guide), lists special engineering rules for interworking, DWDM, and Preside.

Chapter 6, Cable and connector details (in Part 2 of this guide), lists the cables and components used on the shelf.

Chapter 7, Shelf mounting guidelines (in Part 2 of this guide), describes typical installations.

Chapter 8, Ordering information (in Part 2 of this guide), provides procedures and tables to simplify the ordering process.

Chapter 9, Terms and conditions (in Part 2 of this guide), provides contacts to set up an order.

See Table 1-1 for a complete list of supported features in Release 12.1.

Table 1-1

Feature compatibility for Release 12.1

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

Network configurations

 

 

 

 

 

Bidirectional line switched ring (BLSR) (2-fiber) at OC-192 rate

No

Yes

 

 

 

Bidirectional line switched ring (BLSR) (2-fiber) at OC-48 rate

Yes

No

 

 

 

BLSR with linear spur

Yes

Yes

 

 

 

BLSR with subtending UPSR

Yes

Yes

 

 

 

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

 

 

Overview 1-5

 

 

 

Table 1-1 (continued)

 

 

Feature compatibility for Release 12.1

 

 

 

 

 

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

Uni-directional Path switched Ring at OC3, OC-12, OC-48 or

Yes

Yes

OC-192 rates

except OC-192

 

 

 

 

Dual-homed subtending rings (on UPSR)

Yes

Yes

 

 

 

Linear add/drop multiplexer OC-3, and OC-12, OC-48, and

Yes

Yes

OC-192 rates

except OC-192

except OC-192

 

 

 

Linear point-to-point at OC-3, OC-12, OC-48, and OC-192

Yes

Yes

rates

except OC-192

 

 

 

 

Matched nodes (on UPSR)

Yes

Yes

 

 

 

Mixed RPR and TDM traffic over BLSR

Yes

Yes

 

 

 

Mixed RPR and TDM traffic over UPSR (and above UPSR

Yes

Yes

variants)

 

 

 

 

 

Optical hubbing

Yes

Yes

 

 

 

Path-in-line (virtual ring) (across UPSR or BLSR)

Yes

Yes

 

 

 

RPR over BLSR (working and protection channels)

Yes

Yes

 

 

 

RPR over UPSR (and above UPSR variants)

Yes

Yes

 

 

 

Single-homed subtending rings (on UPSR)

Yes

Yes

 

 

 

UPSR to non-OPTera Metro 3500 BLSR interconnection

Yes

Yes

 

 

 

In-service reconfigurations

 

 

 

 

 

Adding a network element to an OC-48 or OC-192 BLSR

Yes

Yes

 

except OC-192

except OC-48

 

 

 

Adding a network element to a UPSR

Yes

Yes

 

except OC-192

 

 

 

 

Adding an OMX shelf to an in-service DWDM network

Yes

Yes

 

 

 

Adding an OPTera Metro 3500 network element to an OC-48

Yes

Yes

UPSR over DWDM

 

 

 

 

 

Adding an OPTera Metro 3500 network element to an OC-48

Yes

No

BLSR over DWDM

 

 

 

 

 

Converting an OC-48 UPSR to an OC-48 UPSR over DWDM

Yes

Yes

 

 

 

Converting an OC-48 BLSR to an OC-48 BLSR over DWDM

Yes

No

 

 

 

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-6 Overview

Table 1-1 (continued)

Feature compatibility for Release 12.1

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

Converting an OC-48 linear point-to-point network to an

Yes

Yes

OC-48 linear point-to-point network over DWDM

 

 

 

 

 

Adding an OPTera Metro 3500 network element to an OC-192

No

Yes

UPSR over DWDM

 

 

 

 

 

Converting an OC-192 UPSR to an OC-192 UPSR over

No

Yes

DWDM

 

 

 

 

 

Converting an OC-192 linear point-to-point network to an

No

Yes

OC-192 linear point-to-point network over DWDM

 

 

 

 

 

Converting a UPSR to a BLSR

Yes

Yes

 

See Note 3

See Note 3

 

 

 

Converting a 1+1 linear point-to-point configuration to a

Yes

Yes

2-node UPSR

 

 

 

 

 

Converting a 2-node UPSR to a 1+1 linear point-to-point

Yes

Yes

configuration

 

 

 

 

 

Moving a synchronization boundary

Yes

Yes

 

 

 

Removing a network element from an OC-48 or OC-192 BLSR

Yes

Yes

 

except OC-192

except OC-48

 

 

 

Removing a network element from a UPSR

Yes

Yes

 

 

 

Removing an OPTera Metro 3500 network element from an

Yes

No

OC-48 BLSR over DWDM

 

 

 

 

 

Removing an OPTera Metro 3500 network element from an

Yes

Yes

OC-48 UPSR over DWDM

 

 

 

 

 

Replacing a DS3x3 mapper with a DS3x12 / DS3x12e mapper

Yes

Yes

 

 

 

Replacing an EC-1x3 circuit pack with an EC-1x12 circuit pack

Yes

Yes

 

 

 

Replacing the ILAN circuit pack with a network processor

Yes

Yes

 

 

 

Replacing the network processor with an ILAN circuit pack

Yes

Yes

 

 

 

Upgrading a fiber span from an OC-3 to an OC-12 rate

Yes

Yes

(See Note 2)

 

 

 

 

 

Upgrading a fiber span from an OC-12 to an OC-48 rate

Yes

Yes

(See Note 2)

 

 

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

 

 

Overview 1-7

 

 

 

Table 1-1 (continued)

 

 

Feature compatibility for Release 12.1

 

 

 

 

 

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

Upgrading a fiber span from an OC-48 to an OC-192 rate

No

Yes

 

 

See Note 3

 

 

 

Converting a VT-assigned BLSR connection to a Full VT

Yes

No

BLSR connection

 

 

 

 

 

Converting a Full VT BLSR connection to a VT-assigned

Yes

No

BLSR connection

 

 

 

 

 

Services

 

 

 

 

 

DS1

Yes

Yes

 

 

 

DS3

Yes

Yes

 

 

 

DS3 (Channelized)

Yes

No

 

 

 

EC-1

Yes

Yes

 

 

 

OC-3

Yes

Yes

 

 

 

OC-12

Yes

Yes

 

 

 

OC-48

Yes

Yes

 

 

 

OC-192

No

Yes

 

 

 

Optical Ethernet - Private Line service using 10/100 Ethernet

Yes

Yes

 

 

 

Optical Ethernet - Private Line using Gigabit Ethernet

Yes

Yes

 

 

full rate support

 

 

 

OPTera Packet Edge System

Yes

Yes

See:

 

 

• OPTera Metro 3000 OPTera Packet Edge System User Guide

 

 

(NTN465YG)

 

 

• OPTera Packet Edge System Planning Guide (NTRN10YK)

 

 

• OPTera Packet Edge System Network Applications and

 

 

Management (NTRN11YK)

 

 

 

 

 

Resilient Packet Ring (RPR)

Yes

Yes

 

 

 

Storage Network (Fibre Channel (FC100) & FICON)

Yes

Yes

 

 

 

Test Access Electrical and Optical TAPS (monitor and split

Yes

Yes

states)

 

 

 

 

 

Hardware (See Note 2)

 

 

 

 

 

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-8 Overview

Table 1-1 (continued)

Feature compatibility for Release 12.1

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

OPTera Metro 3500 Shelf Assembly (NTN476AA)

Yes

Yes

 

 

See Note 4

 

 

 

OPTera Metro 3500 Shelf Assembly (NTN476DA)

Yes

Yes

 

 

 

OPTera Metro 3500 Universal Shelf Assembly (NTN476AH)

Yes

Yes

 

 

 

2x100BT-P2P circuit pack (NTN433AA)

Yes

Yes

 

 

 

4x100FX (NTN4333EA, NTN433FA)

Yes

Yes

 

 

 

4x100BT (NTN433BB)

Yes

Yes

 

 

 

2x1000SX (NTN438AA)

Yes

Yes

 

 

 

2x1000LX (NTN438BA)

Yes

Yes

 

 

 

2xGigE/FC-P2P (NTN438DA)

Yes

Yes

 

 

 

1000-BaseSX 850 nm SFP (NTTP51AA)

Yes

Yes

 

 

 

1000-BaseLX 1310 nm SFP (NTTP51BD)

Yes

Yes

 

 

 

1000-BaseZX 1550 nm SFP (NTTP51DZ)

Yes

Yes

 

 

 

DS1 mapper (1:N protection)

Yes

No

 

 

 

DS1 service module (DSM) (up to 12 protected or unprotected

Yes

Yes

DSM on an NE)

 

 

 

 

 

DS3 mapper

No

No

See Note 5

 

 

 

 

 

DS3VTx12 mapper

Yes

No

 

 

 

DS3x12 mapper (1+1 protection)

Yes

Yes

 

 

 

DS3x12e mapper (1+1 protection)

Yes

Yes

 

 

 

DS3x3 mapper (1+1 protection) (NTN437AA)

Yes

Yes

 

 

 

DSM DS1x84 termination module (TM)

Yes

Yes

 

 

 

EC-1 circuit pack

No

No

See Note 5

 

 

 

 

 

EC-1x12 circuit pack (1+1 protection)

Yes

Yes

 

 

 

EC-1x3 circuit pack (1+1 protection) (NTN436AA)

Yes

Yes

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

 

 

Overview 1-9

 

 

 

Table 1-1 (continued)

 

 

Feature compatibility for Release 12.1

 

 

 

 

 

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

OC-3 circuit pack in slots 11 and 12 (UPSR, 1+1 linear

No

No

point-to-point and 1+1 linear ADM)

 

 

 

 

 

OC-3 circuit pack in slots 3 through 10 (UPSR, 1+1 linear

Yes

Yes

point-to-point and 1+1 linear ADM)

 

 

 

 

 

OC-3x4 circuit pack in slots 11 and 12 (UPSR, 1+1 linear

No

No

point-to-point and 1+1 linear ADM)

 

 

 

 

 

OC-3x4 circuit pack in slots 3 through 10 (UPSR, 1+1 linear

Yes

Yes

point-to-point and 1+1 linear ADM)

 

 

 

 

 

OC-12 circuit pack in slots 11 and 12 (UPSR, 1+1 linear

Yes

No

point-to-point and 1+1 linear ADM)

 

 

 

 

 

OC-12 circuit pack in slots 3 through 10 (UPSR, 1+1 linear

Yes

Yes

point-to-point and 1+1 linear ADM)

 

 

 

 

 

OC-12x4 STS circuit pack in slots 11 and 12 (UPSR, 1+1

No

No

linear point-to-point and 1+1 linear ADM)

 

 

 

 

 

OC-12x4 STS circuit pack in slots 3 through 10 (UPSR, 1+1

No

Yes

linear point-to-point and 1+1 linear ADM)

 

 

 

 

 

OC-48 circuit pack in slots 11 and 12 (BLSR, UPSR, 1+1 linear

Yes

No

point-to-point)

 

 

 

 

 

OC-48 circuit pack in slots 3 through 10 (UPSR, 1+1 linear

No

No

point-to-point)

 

 

 

 

 

OC-48 STS circuit pack in slots 3 to 12 (UPSR, 1+1 linear

No

Yes

point-to-point)

 

 

 

 

 

OC-48 DWDM circuit pack in slots 11 and 12 (BLSR, UPSR,

Yes

No

1+1 linear point-to-point)

 

 

 

 

 

OC-48 DWDM circuit pack in slots 3 through 10 (UPSR, 1+1

No

No

linear point-to-point)

 

 

 

 

 

OC-192 circuit pack in slots 11 and 12 (BLSR, UPSR, 1+1

No

Yes

linear point-to-point)

 

 

 

 

 

OC-192 circuit pack in slots 3 through 10 (UPSR, 1+1 linear

No

No

point-to-point)

 

 

 

 

 

STM-0 optical interface (1+1 protection) (in J-SDH mode)

No

No

See Note 5

 

 

 

 

 

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-10 Overview

Table 1-1 (continued)

Feature compatibility for Release 12.1

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

STM-1 optical interface (1+1 protection) (in J-SDH mode)

No

No

See Note 5

 

 

 

 

 

STM-1x4 optical interface (in J-SDH mode)

Yes

Yes

(in Slots 3 through 10)

 

 

 

 

 

Intershelf LAN (ILAN) circuit pack

Yes

Yes

 

 

 

Network Processor circuit pack (NP circuit pack) (NTN422AA)

No

No

See Note 5

 

 

 

 

 

Network Processor circuit pack - extended (NPx circuit pack)

Yes

Yes

(NTN424Bx)

 

 

 

 

 

Shelf Processor circuit pack - terminal (SP circuit pack)

No

No

(NTN420AA)

 

 

See Note 5

 

 

 

 

 

Shelf Processor circuit pack - enhanced (SPe circuit pack)

No

No

(NTN421BA)

 

 

See Note 5

 

 

 

 

 

Shelf Processor circuit pack - extended (SPx circuit pack)

Yes

Yes

(NTN423Bx)

 

 

 

 

 

OMX shelf

Yes

Yes

 

 

 

Performance monitoring

 

 

 

 

 

DS1 line and path

Yes

Yes

 

 

See Note 6

 

 

 

DS1e far-end line and path

Yes

Yes

 

 

See Note 6

 

 

 

DS1e far-end line and path with F bit generation

Yes

Yes

 

 

See Note 6

 

 

 

DS3 line and path

Yes

Yes

 

 

 

DS3/VT line and path

Yes

No

 

 

 

EC-1 section and line

Yes

Yes

 

 

 

Path PMs on DS3x12e circuit pack

Yes

Yes

 

 

 

OC-12 section and line

Yes

Yes

 

 

 

OC-3 section and line

Yes

Yes

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

 

 

Overview 1-11

 

 

 

Table 1-1 (continued)

 

 

Feature compatibility for Release 12.1

 

 

 

 

 

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

OC-48 section and line

Yes

Yes

 

 

 

OC-192 section and line

No

Yes

 

 

 

Physical performance monitoring for OC-48 DWDM ER and

Yes

No

ELR circuit pack-receiver

 

 

 

 

 

Physical performance monitoring for OC-48 STS and OC-192

No

Yes

circuit pack-receiver

 

 

 

 

 

STM-0 section and line (in J-SDH mode)

No

No

See Note 5

 

 

 

 

 

STM-1 section and line (in J-SDH mode)

Yes

Yes

See Note 5

 

 

 

 

 

STS-1 path

Yes

Yes

 

 

 

STS-3c path

Yes

Yes

 

 

 

STS-12c path

Yes

Yes

See Note 7

 

 

 

 

 

STS-24c path

No

Yes

 

 

 

STS48c path

No

Yes

 

 

 

Ethernet Operational Measurements

Yes

Yes

 

 

 

Security and administration

 

 

 

 

 

User account creation

Yes

Yes

 

 

 

Network element / network processor naming

Yes

Yes

 

 

 

Time zone, date and time setting

Yes

Yes

 

 

 

Maintenance and updating of accounts and network element

Yes

Yes

parameters

 

 

 

 

 

Intrusion attempt handling on the SPx and NPx

Yes

Yes

 

 

 

Password management on the SPx and NPx

Yes

Yes

 

 

 

Customer managed networks on the SPx and NPx

Yes

Yes

 

 

 

Security log / audit trail

Yes

Yes

 

 

 

Multiple authentication methods

Yes

Yes

 

 

 

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-12 Overview

Table 1-1 (continued)

Feature compatibility for Release 12.1

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

Challenge / Response authentication

Yes

Yes

 

 

 

Centralized authentication through a RADIUS server

Yes

Yes

 

 

 

Third span of control surveillance

Yes

Yes

 

 

 

General Broadcast tool

Yes

Yes

 

 

 

Bandwidth management

 

 

 

 

 

In-service traffic rollover for TDM traffic

Yes

Yes

 

 

 

In-service traffic rollover for RPR traffic

No

No

 

 

 

STS-1 traffic

Yes

Yes

 

 

 

STS-3c traffic

Yes

Yes

 

 

 

STS-12c traffic

Yes

Yes

 

 

 

STS-24c traffic

No

Yes

 

 

 

STS-48c traffic

No

Yes

 

 

 

STS-48c, STS24c, STS-12c, STS-3c, STS-1 time slot

Yes

Yes

assignment (TSA) on pass-through nodes on BLSR

except STS24c &

 

 

STS-48c

 

 

 

 

STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5

Yes

Yes

broadcast on 1+1 linear, UPSR

except STS24c &

except VT1.5

 

STS-48c

 

 

 

 

STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5

Yes

Yes

drop-and-continue on 1+1 linear, UPSR

except STS24c &

except VT1.5

 

STS-48c

 

 

 

 

STS48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5

No

No

drop-and-continue on BLSR

 

 

 

 

 

STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5

Yes

Yes

hairpinning

except STS24c &

VT1.5

 

STS-48c

 

 

 

 

STS-48c, STS-24c, STS-12c,STS-3c, STS-1, VT1.5 time slot

Yes

Yes

assignment (TSA) on 1+1 linear, UPSR

except STS24c &

VT1.5

 

STS-48c

 

 

 

 

STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 time slot

Yes

Yes

assignment (TSA) on add/drop nodes on BLSR

except STS-48c

VT1.5

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

 

 

Overview 1-13

 

 

 

Table 1-1 (continued)

 

 

Feature compatibility for Release 12.1

 

 

 

 

 

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 time slot

Yes

Yes

interchange (TSI) on 1+1 linear, UPSR

except STS24c &

VT1.5

 

STS-48c

 

 

 

 

STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 time slot

Yes

Yes

interchange (TSI) on BLSR

except STS24c &

VT1.5

 

STS-48c

 

 

 

 

TU11, TU21, AU32, AU4 cross-connects (in J-SDH mode)

Yes

Yes

 

 

supports AU32

 

 

and AU4

 

 

 

VT1.5/ time slot assignment (TSA) on pass-through nodes on

Yes

No

BLSR

 

 

 

 

 

VT6 cross-connects (in J-SDH mode)

Yes

No

 

 

 

Miscellaneous

 

 

 

 

 

6.312-MHz clock (in J-SDH mode)

Yes

Yes

 

 

 

Alarm provisioning

Yes

Yes

 

 

 

Composite clock timing (in J-SDH mode)

Yes

Yes

 

 

 

Consolidated load

Yes

Yes

 

 

 

DS1 ESF BITS synchronization status messaging

Yes

Yes

 

 

 

DS1 automatic in-service (AINS)

Yes

Yes

 

 

 

DS1 loopback

Yes

No

 

 

 

DS3 automatic in-service (AINS) on T3 facilities

Yes

Yes

 

 

 

DS3 loopback

Yes

Yes

 

 

 

DS3/VT automatic in-service (AINS) on T3 facilities

Yes

No

 

 

 

External building-integrated timing supply (BITS) input/output

Yes

Yes

 

 

 

Full TARP

Yes

Yes

 

 

 

Hitless timing reference switching

Yes

Yes

 

 

 

Independent synchronization and bandwidth management

Yes

Yes

switching

 

 

 

 

 

Mixed tributaries

Yes

Yes

 

 

 

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-14 Overview

Table 1-1 (continued)

Feature compatibility for Release 12.1

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

NP/SP version checking

Yes

Yes

 

 

 

OC-3 1+1 high speed exerciser

Yes

Yes

 

 

 

OC-12 1+1 high-speed exerciser

Yes

Yes

 

 

 

OC-48 1+1 high-speed exerciser

Yes

Yes

 

 

 

OC-192 1+1 high-speed exerciser

No

Yes

 

 

 

Optical Facility loopbacks for OC-3, OC-12, EC1x12, OC-3x4,

Yes

Yes

STM-1x4, OC-12x4 STS, OC-48, OC-48 STS, OC-192,

except OC-192

 

2xGigE/FC-P2P

 

 

 

 

 

Optical Terminal loopbacks for OC-3, OC-12, EC1x12,

Yes

Yes

OC-3x4, STM-1x4, OC-12x4 STS, OC-48, OC-48 STS,

except OC-192

except OC-192

OC-192, 2xGigE/FC-P2P

 

 

 

 

 

OSI 7 layer

Yes

Yes

 

 

 

Path trace

Yes

Yes

 

 

 

Site Manager Rel 6.0.1

Yes

Yes

See Note 8

 

 

 

 

 

Remote save and restore

Yes

Yes

 

 

 

S1 byte synchronization status messaging

Yes

Yes

 

 

 

Section trace

Yes

Yes

 

 

 

Shelf timing (internal, line/loop, tributary, external)

Yes

Yes

 

 

 

Stratum 3 internal clock

Yes

Yes

 

 

 

SP spare management enhancements

Yes

Yes

 

 

 

SSbit functionality at OC-3, OC-12, OC-48 and OC-192 rates

Yes

Yes

 

except OC-192

 

 

 

 

STS-1 path trace for DS3, OC-3, OC-12, OC-48 and OC-192

Yes

Yes

 

except OC-192

See Note 9

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

 

 

Overview 1-15

 

 

 

Table 1-1 (continued)

 

 

Feature compatibility for Release 12.1

 

 

 

 

 

Feature

Supported on

Supported on

 

platforms with

platforms with

 

VTX-series

STX circuit packs

 

circuit packs

 

 

 

 

Time of day synchronization

Yes

Yes

 

 

 

VT1.5 group alarm

Yes

No

 

 

 

Note 1: See Table 1-2 on page 1-16 for a list of optical circuit packs supported by each STX and VTX-series circuit packs.

Note 2: See Table 1-2 on page 1-16 for a list of optical circuit packs supported by each STX and VTX-series circuit packs.

Note 3: This is an out-of service procedure.

Note 4: The OPTera Metro 3500 Shelf assembly (NTN476AA) must be upgraded using power module and cooling upgrade kit (NTN458MW) to support OC-192 optical interfaces.

Note 5: This interface is below the hardware baseline for OPTera Metro Release 12.1 and it is not supported.

Note 6: DS1 PMs are available through DSM connected to OPTera Metro 3500 equipped with STX-192 circuit pack.

Note 7: Supported on all new Release 12.1 circuit packs (OC12x4 STS, OC-48 STS and OC-192) along with all OC-48 circuit packs and selected OC-12 circuit packs (NTN404JA, NTN404KA, NTN404LA, NTN404MA).

Note 8: Site Manager Release 6.0.1 is backward compatible to the following releases:

OPTera Metro 3500 Releases 10.1, 10.3, 10.31, 11.01, 11.02, 12.0 and 12.1

OPTera Metro 3300/3400 Releases 9.12, 11.11 and 11.12

OPTera Metro 3100 Release 4.01 and 4.02

Note 9: For OPTera Metro 3500 equipped with STX-192 circuit packs (STS-managed), path trace must be monitored on the path terminating equipment such as DSM module, DS3, 2x100BTP2P, 2xGigGE/FC circuit packs.

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-16 Overview

Release 12.1 Hardware Compatibility Matrix

For a list of supported electrical and optical interfaces by STX and VTX-series circuit packs in Release 12.1, see Table 1-2.

Table 1-2

Hardware Compatibility Matrix for Release 12.1

Card Type

Supported on

Supported on

Notes

 

platform with

platforms with

 

 

STX192

VTX-series

 

 

circuit packs

circuit packs

 

 

 

 

 

OC-192

Yes

No

• Dual slot circuit packs

 

 

 

supported in slots 11

 

 

 

and 12.

 

 

 

• Supported only with

 

 

 

STX-192 circuit pack.

 

 

 

 

OC-48 STS

Yes

No

• Single slot circuit packs

 

 

 

supported in slots 3 to

 

 

 

12.

 

 

 

• Supported only with

 

 

 

STX-192 circuit pack.

 

 

 

 

OC-48

No

Yes

• Dual slot circuit packs

 

 

 

supported in slots 11

 

 

 

and 12.

 

 

 

• Supported only with

 

 

 

VTX-series circuit pack.

 

 

 

 

OC-12x4 STS

Yes

No

• Single slot circuit packs

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

• Supported with STX-192

 

 

 

circuit pack.

 

 

 

 

OC-12

Yes

Yes

• Single slot circuit packs

 

 

 

not supported in slots 11

 

 

 

and 12 with STX-192 or

 

 

 

VTX-48 circuit packs.

 

 

 

• Single slot circuit packs

 

 

 

supported in slots 3

 

 

 

through 10 with STX-192

 

 

 

or VTX-48 circuit packs.

 

 

 

• Single slot circuit packs

 

 

 

supported in slots 3

 

 

 

through 12 with VTX-48e

 

 

 

circuit pack.

 

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Overview 1-17

Table 1-2 (continued)

Hardware Compatibility Matrix for Release 12.1

Card Type

Supported on

Supported on

Notes

 

platform with

platforms with

 

 

STX192

VTX-series

 

 

circuit packs

circuit packs

 

 

 

 

 

OC-3x4

Yes

Yes

Single slot circuit packs

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

OC-3

Yes

Yes

• Single slot circuit packs

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

STM-1x4

Yes

Yes

• Single slot circuit packs

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

2xGigE/FC-P2P

Yes

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

• Maximum bandwidth of

 

 

 

12xSTS1 per card when

 

 

 

equipped with

 

 

 

VTX-series circuit packs.

 

 

 

• Maximum bandwidth of

 

 

 

2xSTS24 per card when

 

 

 

equipped with STX-192

 

 

 

circuit packs.

 

 

 

 

2xGigE (OPE)

Yes

Yes

• Dual slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

• Maximum bandwidth

 

 

 

assignable to a RPR is

 

 

 

STS12c with both

 

 

 

VTX-series and

 

 

 

STX-192 circuit packs.

 

 

 

 

4x100FX (OPE)

Yes

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

• Maximum bandwidth

 

 

 

assignable to a RPR is

 

 

 

STS12c with both

 

 

 

VTX-series and

 

 

 

STX-192 circuit packs.

 

 

 

 

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

1-18 Overview

Table 1-2 (continued)

Hardware Compatibility Matrix for Release 12.1

Card Type

Supported on

Supported on

Notes

 

platform with

platforms with

 

 

STX192

VTX-series

 

 

circuit packs

circuit packs

 

 

 

 

 

4x100BT(OPE)

Yes

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

• Maximum bandwidth

 

 

 

assignable to a RPR is

 

 

 

STS12c with both

 

 

 

VTX-series and

 

 

 

STX-192 circuit packs.

 

 

 

 

2x100BT-P2P

Yes

Yes

• Single slot circuit pack

(Private Lines)

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

EC-1x12

Yes

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

DS3x12

Yes

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

EC-1x3

Yes

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

DS3VTx12

No

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

DS3x3

Yes

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

12xDS1

No

Yes

• Single slot circuit pack

 

 

 

supported in slots 3

 

 

 

through 10.

 

 

 

 

84xDS1 (DSM)

Yes

Yes

• Support for 12 DSM per

 

 

 

shelf.

 

 

 

• DSM is only STS-1

 

 

 

managed with STX-192.

 

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Loading...
+ 312 hidden pages