ATTIX 360-2M
ATTIX 550-2M
ATTIX 560-2MXC
ATTIX 751-2M
ATTIX 761-2MXC
english |
Operating Instructions................................ |
1-15 |
deutsch |
Betriebsanleitung...................................... |
16-30 |
français |
Notice d’utilisation .................................... |
31-45 |
nederlands Gebruiksaanwijzing .................................. |
46-60 |
|
italiano |
Istruzioni sull’uso...................................... |
61-75 |
norsk |
Driftsinstruks............................................. |
76-90 |
svensk |
Bruksanvisning ....................................... |
91-105 |
dansk |
Driftsvejledning ..................................... |
106-120 |
suomi |
Käyttöohje.............................................. |
121-135 |
slovensći |
Navodilo za uporabo .............................. |
136-150 |
hrvatski |
Uputstvo za rad ....................................... |
151-165 |
slovenský |
Prevádzkový návod ................................. |
166-180 |
český |
Provozní návod........................................ |
181-195 |
polski |
Instrukcja obsługi.................................... |
196-210 |
magyar |
Kezelési utasítás ..................................... |
211-225 |
русский |
Руководство по эксплуатации ............... |
226-240 |
español |
Instrucciones de manejo ...................... |
241-255 |
português |
Instruções de operação........................ |
256-270 |
ελληνικά |
Οδηγίες λειτουργίας.............................. |
271-285 |
türkçe |
Ýþletme kýlavuzu..................................... |
286-300 |
302001674 - 2005-01-14
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
|
ATTIX 3 |
|
3 |
10 |
|
|
|
|
11 |
1 |
|
3 |
|
|
14 |
|
|
9 |
auto |
|
|
4 |
|
|
5 |
|
8 |
6 |
|
|
|
|
|
|
10 |
|
7 |
|
|
14 |
|
|
9 |
auto auto |
|
1 |
8 |
|
ATTIX 7 |
2 |
|
|
|
10 |
|
|
14 |
|
3 |
|
|
|
9 |
auto auto |
|
|
|
4 |
|
|
5 |
8 |
|
12 |
|
|
|
|
|
5 |
|
|
6 |
ATTIX 5
1
2
3
4
5
6
7
12 |
13 |
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
Contents english
1 |
Important safety |
|
|
|
|
instructions |
|
............................................................................................ |
2 |
2 |
Description |
2.1 |
Purpose................................................................................ |
4 |
|
|
2.2 |
Operating elements .............................................................. |
5 |
3 |
Before start-up |
3.1 |
Assembling the cleaner ........................................................ |
5 |
4 |
Operation |
4.1 |
Connections ......................................................................... |
5 |
|
|
4.1.1 |
Connecting the suction hose ................................................ |
5 |
|
|
4.1.2 |
Electrical connection ............................................................ |
5 |
|
|
4.1.3 |
Connecting electrical appliances.......................................... |
6 |
|
|
4.2 |
Switching on the vacuum cleaner......................................... |
6 |
|
|
4.2.1 |
Switch position “I” ................................................................. |
6 |
|
|
4.2.2 |
Switch position „auto“ ........................................................... |
6 |
|
|
4.2.3 |
Suction power control........................................................... |
6 |
|
|
4.3 |
Check volume flow monitor .................................................. |
6 |
|
|
4.4 |
Acoustic warning .................................................................. |
7 |
|
|
4.5 |
Cleaning the filter element (ATTIX 360-2M) ......................... |
7 |
|
|
4.6 |
Cleaning the filter element (ATTIX 560-2MXC/761-2MXC) ..7 |
|
5 |
Applications and |
5.1 |
Techniques ........................................................................... |
8 |
|
techniques |
5.1.1 |
Picking up dry substances ................................................... |
8 |
|
|
5.1.2 |
Picking up liquids.................................................................. |
9 |
6 |
After finishing work |
6.1 |
Switching the vacuum cleaner off and storage..................... |
9 |
7 |
Maintenance |
7.1 |
Maintenance plan ............................................................... |
10 |
|
|
7.2 |
Maintenance work .............................................................. |
10 |
|
|
7.2.1 |
Replacing the waste bag .................................................... |
10 |
|
|
7.2.2 |
Replacing the filter bag....................................................... |
11 |
|
|
7.2.3 |
Emptying dirt tank (ATTIX 3+5) .......................................... |
11 |
|
|
7.2.4 |
Emptying the dirt tank (ATTIX 7)..................................... |
11 |
|
|
7.2.5 |
Replacing filter element (ATTIX 360-2M/550-2M/751-2M) .12 |
|
|
|
7.2.6 |
Replacing filter element (ATTIX 560-2MXC/761-2MXC) .... |
12 |
8 |
Troubleshooting |
|
.......................................................................................... |
13 |
9 |
Further information |
9.1 |
Recycling the vacuum cleaner ........................................... |
14 |
|
|
9.2 |
Guarantee .......................................................................... |
14 |
|
|
9.3 |
Tests and approvals ........................................................... |
14 |
|
|
9.4 |
Technical data .................................................................... |
15 |
|
|
9.5 |
Accessories........................................................................ |
15 |
|
|
9.6 |
EC declaration of conformity .............................................. |
15 |
1) Option depending on model |
1 |
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
english 1 Important safety instructions
Symbols used to mark |
|
|
Before using the |
|||
instructions |
|
|
vacuum cleaner, |
|||
|
|
|
always |
read |
||
|
|
|
the |
operating |
||
|
|
|
instructions |
|
and |
|
|
|
|
keep them read- |
|||
|
ily available. |
|
|
|
||
|
|
|
This |
symbol |
is |
|
|
|
|
used |
to |
mark |
|
|
|
|
safety |
instruc- |
||
|
|
|
tions |
that |
must |
|
|
|
|
be observed |
to |
||
|
prevent damage to persons. |
|
||||
For your own safety |
Only allow the vacuum cleaner |
|||||
|
to be used by persons who have |
|||||
|
been trained in its use and who |
|||||
|
have been explicitly authorized |
|||||
|
to use it. |
|
|
|
Despite its simple handling the vacuum cleaner is not suitable for children.
This symbol is used to mark safety instructions that must be observed to prevent damage
to the vacuum cleaner and its performance.
This symbol indicates tips and instructions to
simplify work and to ensure safe operation.
The use of the vacuum cleaner is subject to valid national regulations. Besides the operating instructions and the binding accident prevention regulations valid in the country of use, observe recognized regulations for safety and proper use.
Do not use any unsafe work techniques.
Transport |
Before transporting the dirt |
|
tank, close all the locks. |
|
Do not tilt the cleaner if there is |
|
liquid in the dirt tank. |
Do use a crane hook to lift the cleaner.
Purpose and intended use |
The vacuum cleaners described |
|||||
|
in this operating manual are |
|||||
|
suitable for |
|
|
|
|
|
|
– |
commercial |
use, |
e.g. |
in |
|
|
|
hotels, |
schools, |
hospitals, |
||
|
|
factories, shops, offices and |
||||
|
|
rental businesses. |
|
|
||
|
– for separation of dust with an |
|||||
|
|
exposure limit of greater than |
||||
|
|
0,1 mg/m³, (dust class M). |
||||
|
The following |
materials should |
||||
|
not be picked up by the vacuum |
|||||
|
cleaner: |
|
|
|
|
|
|
– |
hot materials (burning ciga- |
||||
|
|
rettes, hot ash, etc.) |
|
|||
|
– flammable, |
explosive, |
ag- |
|||
|
|
gressive |
liquids (e.g. petrol, |
solvents, acids, alkalis, etc.)
–flammable, explosive dust (e.g. magnesium or aluminium dust, etc.)
When dust removers are used, the rate at which air is exchanged in the room must be adequate if the exhaust air from the vacuum cleaner is blown into the room (please observe regulations valid in your country).
Before starting work, the operating staff must be informed on
–use of the vacuum cleaner
–risks associated with the material to be picked up
–safe disposal of the picked up material.
2 |
1) Option depending on model |
Precautions and safety regulations when using the vacuum cleaner
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
Before start-up |
Electrical components |
english |
Inspect power cord regularly to detect signs of damage, e.g. cracks or ageing.
If the power cord is damaged, it must be replaced by Nilfisk- Alto-Service or an electrician to avoid danger before use of the vacuum cleaner is continued.
Use only the type of power cord specified in the operating manual.
Do not damage the power cord (e.g. by moving over it or pulling or crushing it).
Disconnect the power cord by pulling the plug only (do not pull or tug the power cord).
Inspect the vacuum cleaners to ensure that they are in proper condition. Plugs and couplings in power cords must at least have splash protection.
Never use the vacuum cleaner if the filter element is damaged.
Picking up liquids
If foam develops or liquid emerges, stop work immediately and empty the dirt tank.
Regularly clean the built in float (ATTIX 360-2M/550-2M/751- 2M) and level indicator hose (ATTIX 560-2MXC/761-2MXC) to limit the water level and check that they are not damaged.
See section 5 for information on handling liquids and (hazardous) dust.
Check the rated voltage of the vacuum cleaner before connecting it to the mains supply system. Ensure that the voltage shown on the rating plate corresponds to the voltage of the local mains power supply.
If you are using an extension cord, use only those specified by the manufacturer or higher quality ones (see section 9.4 „Technical data“).
It is recommended that the vacuum cleaner should be connected via a residual current circuit breaker. This stops the supply of electricity if the leakage current to earth exceeds 30 mA for 30 ms or it has an earth tester circuit.
When using an extension lead, check the minimum cross-sec- tions of the cable:
Cable length |
Cross section |
|
m |
<16 A |
<25 A |
|
||
up to 20 m |
ø1.5mm² |
ø2.5mm² |
|
|
|
20 to 50 m |
ø2.5mm² |
ø4.0mm² |
|
|
|
Arrange the electrical parts (sockets, plugs and couplings) and lay down the extension lead so that the protection class is maintained.
Never spray water on to the upper section of the vacuum cleaner. Danger for persons, risk or short-circuiting.
Observe the latest edition of the IEC regulations.
1) Option depending on model |
3 |
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
english |
Tool socket |
Use the socket on the vacuum |
2. Switch off the appliance to |
||
|
|
cleaner for the purpose defined |
be connected. |
||
|
|
in |
the |
operating instructions |
|
|
|
only. |
|
CAUTION! |
|
|
|
|
|
|
Follow the operating instructions |
|
|
Before |
plugging an appliance |
and safety instructions for appli- |
|
|
|
into the appliance socket: |
ances connected to the power |
||
|
|
1. |
Switch off the vacuum clean- |
tool socket. |
|
|
|
|
er |
|
|
Maintenance, cleaning and |
Only carry |
out maintenance |
|
repair |
work described in the operating |
||
|
instructions. |
|
|
|
Always pull out the mains plug |
||
|
before cleaning and mainte- |
||
|
nance of the vacuum cleaner. |
||
|
During maintenance and clean- |
||
|
ing, handle the vacuum cleaner |
||
|
in such a manner that there is no |
||
|
danger for maintenance staff or |
||
|
other persons. |
||
|
In the maintenance area |
||
|
– use filtered compulsory ven- |
||
|
|
tilation |
|
|
– |
wear protective clothing |
|
|
– |
clean the |
maintenance are |
|
|
so that no harmful substanc- |
|
|
|
es get into the surroundings. |
Before removing the vacuum cleaner from the area contaminated with harmful substances:
Accessories and spare parts |
Use |
only the brushes supplied |
|
with |
the vacuum cleaner or |
|
specified in the operating manu- |
|
|
al. The use of other brushes can |
–clean the outside of the vacuum cleaner, wipe it clean or pack the vacuum cleaner in well sealed packaging
–and avoid spreading deposited harmful dust.
During maintenance and repair work all contaminated parts that could not be cleaned satisfactorily must be:
–packed in well sealed bags
–disposed of in a manner that complies with valid regulations for such waste removal.
A dust test must be performed at least once every year by NilfiskAlto service or a trained person. This test includes, for example, whether there is damage to the filter, the vacuum cleaner is sealed to the air and the control equipment works properly.
adversely affect safety.
Use only original Nilfisk-Alto accessories and spare parts (see section 9.5). The use of other parts can adversely affect safety.
2 Description
2.1 Purpose |
This cleaner is suitable to pick |
|
up dry, nonflammable dust, liq- |
|
uids, sawdust and hazardous |
|
dusts with maximum room con- |
|
centration values ≥ 0.1 mg/m3 |
|
(dust class M). |
Depending on how hazardous the dust is, the cleaner must be fitted with appropriate filters. See table in section 5.1.1.
4 |
1) Option depending on model |