Nilfisk POSEIDONG 45 User Manual

0 (0)
Nilfisk POSEIDONG 45 User Manual

POSEIDONG45

Betjeningsvejledning

DK

Bruksanvisning

N

Bruksanvisning

S

Operating guide

UK

Betribsanleitung

D

Mode d’emploi

F

Gebruiksaanwijzingen

NL

Instrucciones de manejo

E

Instruções para uso

P

Käyttöopas

FI

,QVWUXNFMD REVáXJL

PL

ƪNJNJdžnjLjljƾ - ǎįdžDŽǁİǐ NJİLjIJǎǑǏDŽǁƾǐ

GR

Operating guide

30100298606951019.012007-01-02

POSEIDONG45

POSEIDON 5

Contents

english

 

 

Symbols used to mark

 

 

 

 

instructions

 

............................................................................................

2

1

Important safety

 

 

 

 

instructions

 

............................................................................................

2

2

Description

2.1

Purpose................................................................................

4

 

 

2.2

Operating elements ..............................................................

4

3

Before starting the cleaner

3.1

Setting up the cleaner ..........................................................

5

 

 

3.2

Fill up detergent tank1) .....................................................................................................

5

 

 

3.3

Connecting the high pressure hose......................................

5

 

 

3.4

Connecting the water supply ................................................

6

 

 

3.5

Electrical connection ............................................................

6

 

 

3.6

Antifreeze - before first use ..................................................

6

4

Control / Operation

4.1

Connections .........................................................................

7

 

 

4.2

Switching on the cleaner ......................................................

7

 

 

4.3

Pressure regulation (Tornado Lance) ...................................

8

 

 

4.4

Pressure regulation with the FlexoPowerJet nozzle .............

8

 

 

4.5

Pressure regulation on the machine.....................................

8

 

 

4.6

Using cleaning agents ..........................................................

8

5

Applications and methods

5.1

Techniques ...........................................................................

9

 

 

5.2

Some typical cleaning tasks ...............................................

10

6

After using the cleaner

6.1

Switching off the cleaner ....................................................

11

 

 

6.2

Disconnecting supply lines .................................................

11

 

 

6.3

Rolling up the electrical lead and storing accessories .......

12

 

 

6.4

Storing the cleaner (below 0°C) .........................................

12

7

Maintenance

7.1

Maintenance plan ...............................................................

12

 

 

7.2

Maintenance work ..............................................................

13

8

Troubleshooting

 

..........................................................................................

14

9

Further information

9.1

Recycling the cleaner ........................................................

15

 

 

9.2

Guarantee ..........................................................................

15

 

 

9.3

EU Declaration of Conformity.............................................

15

 

 

9.4

Technical Data....................................................................

16

1) Options / model variants

1

POSEIDON 5

english Symbols used to mark instructions

instructions in operating instructions which must be observed to prevent risks to persons are

marked with this danger symbol.

Before using the h i g h - p r e s s u r e cleaner, be sure to also read the enclosed operat-

ing instructions and keep them within reach at all times.

This indicates tips and instructions to simplify work and

to ensure safe operation.

This symbol is used to mark safety instructions that must be observed to pre-

vent damage to the machine and its performance.

1 Important safety instructions

For your own safety

The high-pressure cleaner may only be used by persons instructed in its use and who have been expressly authorised to do so.

Although extremely easy to operate, children should not be allowed to use the cleaner.

General

Use of the high-pressure cleaner is subject to the applicable local regulations.

Besides the operating instructions and the binding accident prevention regulations valid in the country of use, observe recognised regulations for safety and proper use.

Do not use any unsafe work techniques.

Transport

Before starting the cleaner

Transport of the high-pressure cleaner is easy on its large wheels.

For safe transport in and on vehicles we recommend to prevent the equipment from sliding and tilting by fixing it with belts.

Transport (when tilted):

do not tilt the machine on the front with the water connections.

remove suction hose from the detergent tank and close tank filler with the cap provided with the machine.

before putting the cleaner into operation: pay attention to allow the pump oil to run back into the pump housing. Check oil level, top up if necessary.

For transport at temperatures around or below 0°C, anti-freeze should be drawn into the pump beforehand (see chapter 6).

If your 3-phase cleaner was supplied without a plug, have it fitted with a suitable 3-phase plug with earth conductor, by an electrician.

Before use, check that the highpressure cleaner is safe and in proper condition.

Regularly check whether the power cord is damaged or shows signs of ageing.

Use the high-pressure cleaner only when the mains power lead is in a safe condition. (risk of electric shock if damaged!).

Check the rated voltage of the high-pressure cleaner before connecting it to the mains power supply. Ensure that the voltage shown on the rating plate corresponds to the voltage of the local mains power supply.

We strongly recommend that the power supply to the high pressure cleaner be connected via a residual current circuit breaker.

This device stops the supply of

2

1) Options / model variants

electricity if the leakage current to earth exceeds 30 mA for 30 ms or it has an earth tester circuit.

Operate the cleaner only in an upright position!

Please observe the regulations and provisions applicable in your country. Before putting the high-pressure cleaner into service, carry out a visual check of all the major components.

CAUTION!

High-pressure water jets can be dangerous if misused. The jet must not be directed at persons, animals, live electrical equipment or the cleaner itself. Wear appropriate protective clothing and eye protectors.

Do not direct the jet towards yourself or towards other persons in order to clean clothes or footwear.

During operation of the cleaner, recoil forces are produced at the spraying device and, when the spray lance is held at an angle, a torque is also created. The spraying device must therefore be held firmly in both hands.

Do not use the cleaner when other people without protective clothing are in the working area.

Check that cleaning will not result in dangerous substances (e.g.asbestos, oil) being washed off the object to be cleaned and harming the environment.

Do not clean delicate parts made of rubber, fabric, etc. with the 0° jet. Keep some distance between high pressure nozzle and surface in order to prevent the surface from damage.

Do not use the high-pressure hose for lifting loads.

NOTE!

The maximum permissible working pressure and tempera-

ture are printed on the highpressure hose.

Do not continue to use the cleaner if the mains power lead or high-pressure hose is damaged.

Ensure adequate air circulation. Do not cover the cleaner or operate it in inadequately ventilated rooms!

Store the cleaner where it will not be exposed to frost!

Never operate the cleaner without water. Even brief shortages of water result in severe damage to the pump seals.

Operation

CAUTION!

Unsuitable extension leads can represent a source of danger. Always unwind cord from the reels completely to prevent the power cord overheating.

Plugs and connectors of mains power leads must be at least splash water-proof.

When using an extension cord, check the minimum cross-sec- tions of the cable:

Cable length

Cross section

m

<16 A

 

<25 A

 

 

 

up to 20 m

ø1.5mm²

 

ø2.5mm²

 

 

 

 

20 to 50 m

ø2.5mm²

 

ø4.0mm²

 

 

 

 

Do not damage the mains power lead (e.g. by driving over it, pulling or crushing it).

Disconnect the power cord by pulling the plug only (do not pull or tug the power cord).

Electrical equipment

CAUTION!

Never spray electrical equipment with water: danger for per-

POSEIDON 5

sons, risk of short-circuiting.

english

The cleaner may only be connected to a correctly installed plug socket.

Switching on the cleaner may cause voltage fluctuations. Voltage fluctuations should not occur if the impedance at the transfer point is less than 0.15: If in doubt ask your local electricity supplier.

Maintenance and repair

CAUTION!

Always remove the plug from the mains plug socket before cleaning or carrying out maintenance work on the cleaner.

Carry out only the maintenance operations described in the operating instructions. Use only original Gerni spare parts.

Do not make any technical modifications to the high-pressure cleaner.

Ensure that the machine is regularly serviced by Authorised Gerni dealers in accordance with the maintenace plan. Failure to do so will invalidate the warranty.

CAUTION!

High-pressure hoses, fittings and couplings are important for the safety of the cleaner. Use only high-pressure parts approved by the manufacturer!

The mains power lead must not differ from the version specified by the manufacturer and may only be changed by an electrician.

Please contact the Gerni service department or an authorised specialist work-shop for all other maintenance or repair work!

Testing

The cleaner conforms to the German „Guidelines for Liquid Spray Jet Devices“. The high-

1) Options / model variants

3

POSEIDON 5

english

pressure cleaner must be sub-

 

jected to a safety examination

 

in accordance with the „Acci-

 

dent

Prevention

Regulations

 

for Working with Liquid Spray

 

Jet Devices“ as required, but at

 

least every 12 months, by an au-

 

thorised inspector.

 

 

After all repairs or modifica-

 

tions

to electrical

equipment,

 

the protective conductor resist-

 

ance,

the insulation resistance

 

and the leakage current must

 

be measured. Furthermore, a

 

visual inspection of the mains

 

power lead, a voltage and cur-

 

rent measurement and a func-

 

tion test must be carried out. Our

 

after-sales service

technicians

are at your disposal as authorised inspectors.

The complete „Accident Prevention Regulations for Working with Liquid Spray Jet Devices“ are available from the Carl Heymanns Verlag KG, Luxemburger Strasse 449, 50939 Cologne or from the appropriate association of employers’ liability insurances.

Unloader valve

Unacceptably high pressure is fed back without residual pressure via a bypass line into the intake line of the pump when the safety device is tripped.

The unloader valve is set and sealed at the factory and must not be adjusted.

2 Description

2.1 Purpose

This high-pressure cleaner has

 

been designed for professional

 

use in

 

Agriculture

 

industry

 

transport industry

 

automotive cleaning

 

municipal facilities

 

cleaning trade

 

construction industry

 

food industry

 

etc.

Chapter 5 describes the use of the high-pressure cleaner for various cleaning jobs.

Always use the cleaner as described in these operating instructions. Any other use may damage the cleaner or the surface to be cleaned or may result in severe injury to persons.

2.2Operating elements See fold-out page at front of these 10 Pressure regulation

operating instructions.

11

Detergent metering knob

 

 

12

Main switch

1

Handle

13

Pressure regulation on spray

2

Hose reel

 

lance

3

Mains power lead

14

Spray lance

4

Tank filler for detergent

15

Receptacle for Spray lance

5

Pressure gauge

16

Spray gun

6

Detergent tank

17

Detergent intake hose

7

High pressure hose

18

Receptacle for electrical lead

 

connection

 

 

8Supply water connection with water inlet filter

9 Check pump oil level

4

1) Options / model variants

3 Before starting the cleaner

POSEIDON 5

english

3.1Setting up the cleaner

MAX

max min

3.2Fill up detergent tank1)

CAUTION!

Never lift the cleaner alone (weight >70 kg). Always ask a second person to help.

1.Before using the cleaner for the first time, check it carefully to detect any faults or damage.

2.In the event of any damage contact your Gerni dealer immediately.

3.Check whether the oil level is between the minimum and maximum marks. If necessary, add oil (see chapter 9.4 for type of oil).

1.Fill up detergent tank with prediluted Gerni detergent. Capacity see chapter 9.4 Technical Data.

2.pull detergent filter out of the storage and put it through the opening of the detergent tank filler cap.

3.3

Connecting the high

1. Put the quick connector of

 

pressure hose

the high pressure hose onto

3.3.1

Machines without high

the nipple on the cleaner.

 

pressure hose reel

 

3.3.2Machines with high pressure hose reel

B

C

A

1.Put the quick connector of the high pressure hose (A) onto the nipple on the axle.

2.Put the high pressure hose into the hose guide (B) and fix it with the clip.

3.Release the brake (C) on the hose reel and wind up the high pressure hose.