PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H
Portable Air Conditioner
Owner’s Manual
PARTS LIST
Front Back
FIG.5
1. Control panel
2. Carrying handle
3. Water tank
4. Casters
5. Air louvers
Accessories
6. Air filter
7. Exhaust air outlet
8. Air filter
9. Air inlet
10. Cord storage
11. Air inlet
12. Water plug / drainage point
FIG.6
FIG.7
13. Exhaust hose
14. Exhaust hose adapter goes over hose and into
the window kit (or into a
hole in a wall/window)
15. Adapter cover
16. Window spacer – goes into an
open window space
17. Window spacer – goes into an
open window space
18. Window kit – goes into an
open window space and
connects to one end of the
exhaust hose
19. Drain hose for
continuous drainage
20. Activated carbon filter
21. Remote control
3
INSTALLATION INSTRUCTIONS
Installing the Exhaust Hose and Window Kit
This portable air conditioner can be vented with either the window kit or with the exhaust
hose adapter only:
1. Using the window kit:
Window kit
FIG. 8
• Open the window and insert the window kit into the open gap.
• Close the window until the window kit is held securely. You may need to expand the size
of the window kit using the included window spacers. This technique can also be used
for sash windows.
• Insert one end of the exhaust hose into the exhaust air outlet located on the back of the
air conditioner. Attach the exhaust hose adapter to the other end of the exhaust hose
and connect the adapter to the window kit.
2. Using the adapter:
Wall or window
Exhaust
hose adapter
FIG.10
FIG.9
• Cut a hole with a 6” diameter (152 mm) into a wall or window.
• Insert one end of the exhaust hose into the exhaust air outlet located on the back of the
air conditioner. Insert the other end of the exhaust hose through the wall or window
opening and attach the exhaust hose adapter from the outside as shown.
• Cover the hole with the included adapter cover when the air conditioner is not in use.
4
Positioning the Exhaust Hose
• Only use the provided exhaust
hose with this AC. Insert the
exhaust hose into the back of the
unit and secure it in place.
• Avoid kinks and bends in the
exhaust hose. These can cause
expelled moist air to accumulate,
resulting in overheating and
unexpected shut-offs (fig. 11 and
12).
• The exhaust hose may be
extended from 12 inches (300
mm) to 59 inches (1500 mm), but
for maximum cooling efficiency,
use the shortest hose length
possible.
WARNING!
The included exhaust hose is specifically
FIG.11
FIG.12
FIG.13
designed to fit the specifications of this
unit. Do not extend it with your own
hose, as this can cause the air
FIG.14
conditioner to malfunction.
5