INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS FOR:

VENTED GAS FIREPLACE HEATER

NATURAL GAS MODELS GDS60-N and GS60-N

PROPANE GAS MODELS GDS60-P and GS60-P

Model GS60 is made up of Model GDS60 and the Adapter Kit GS-150KT

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your build ing.

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www.napoleonfireplaces.com • ask@napoleon.on.ca

W415-0158 / E / 02.19.04

2

TABLE of CONTENTS

Pg 2-4

INTRODUCTION

Pg 14

GAS INSTALLATION

 

Warranty

15-16 FINISHING

 

General Instructions

 

 

Logo Placement

 

General Information

 

 

 

Front Cast Installation

 

Care of Glass & Plated Parts

 

 

 

Glass Door Closing & Opening

 

Shipping Bracket

 

 

 

Log Placement

5

LOCATION & CLEARANCES

 

17-18 OPERATION / MAINTENANCE

 

 

6-12 DIRECT VENT SPECIFICS MODEL GDS60

Vent Lengths/Air Terminal Locations Special Installation Example

Offset Installation Example Horizontal Terminations Orifice Replacement

Top Vent to Rear Vent Modification Venting Parameters

Wall & Ceiling Protection Horizontal Venting Installation Vertical Venting Installation Stove Vent Connection Mobile Home Installation

13-14 B-VENT SPECIFICS

MODEL GS60

Chimney Installation

'B' Vent Installation

Combustion Air

Adding Vent Sections

Flashing and Storm Collar Installation

Spill Switch

Venting Action Check

Operating Instructions

Maintenance

19 BLOWER INSTALLATION

19 ADJUSTMENTS

Pilot Burner Adjustment

Venturi Adjustments

Restricting Vertical Vents

20-21 REPLACEMENTS

Ordering Replacement Parts

Termination Kits

Replacement Parts

Accessories

22-23 TROUBLE SHOOTING GUIDE

24 SERVICE HISTORY

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

WARNING

The stove is a vented gas-fired heater. Do not burn wood or other materials in this stove.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the stove.

Due to high temperatures, the stove should be located out of traffic and away from furniture and draperies.

Clothing or other flammable material should not be placed on or near the stove.

Any safety screen or guard removed for servicing must be replaced prior to operating the stove.

It is imperative that the control compartments, burners and circulating blower and its passageway in the stove and venting system are kept clean. The stove and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The stove area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Under no circumstances should this stove be modified.

This stove must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this stove if any part has been under water. Immediately call a qualified service technician to inspect the stove and to replace any part of the control system and any gas control which has been under water.

Do not operate the stove with the glass door opened, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the stove glass door.

This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.

NOTE: changes, other than editorial, are denoted by a vertical line in the margin.

W415-0158 / E / 02.19.04

3

NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate.

NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is test-fired and thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.

NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY

The following materials and workmanship in your new NAPOLEON gas fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled components and aluminum extrusion trims.

Electrical (110V and millivolt) components and wearable parts such as catalytic tiles, blowers, gas valves, thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty.

Labour related to warranty repair is covered free of charge during the first year. Repair work, however, requires the prior approval of an authorized company official. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer.

CONDITIONS AND LIMITATIONS

NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:

This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.

The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes.

This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.

This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.

NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years NAPOLEON will replace or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON will provide replacement burners at 50% of the current retail price.

In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.

After the first year, with respect to this President's Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).

After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty.

Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages.

This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.

NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.

Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.

The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.

NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.

W415-0158 / E / 02.19.04

4

GENERAL INSTRUCTIONS

THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area,

for example: in Massachusetts State:

The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.

The appliance off valve must be a “T” handle gas cock.

The flexible connector must not be longer than 36 inches.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.

WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts.

In absence of local codes, install to the current CAN1-B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1, and NFPA 54 in the United States. Mobile home installation must conform with local codes. In the absence of local codes, install to the current standard for gas equipped mobile housing CAN/CSA Z240 MH Series in Canada or the manufactured home construction and safety standard, Title 24 CFR, part 3280, or the Fire Safety Criteria for manufactured home installations, Sites and Community Standard ANSI/NFPA 501A in the United States.

Purge all gas lines with the glass door of the stove removed. Assure that a continuous gas flow is at the burner before reinstallingthedoor.

Underextremeventconfigurations,allowseveralminutes(5- 15)fortheflametostabilizeafterignition.

It is recommended that all horizontal runs have a ¼ inch rise perfoot.

Objects placed in front of the stove must be kept a minimum of 48" away from the front face of the unit.

The stove and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The stove must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5 kPa).

The stove, when installed with a blower, must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRICAL CODE in the United States. The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug.

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TESTFIRED TO ASSURE ITS OPERATION AND QUALITY!

Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. When the valve is set to "HI", the manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane. When the fireplace is installed at elevations above 4,500ft, and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft.

W415-0158 / E / 02.19.04

Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.

This appliance is only for use with the type of gas indicated on the rating plate. (See page 14). This appliance is not convertible for use with other gases, unless a certified kit is used.

INSTALLER: It is your responsiblity to check off the appropriate box on the rating plate according to the model, venting and gas type of the unit.

CARE OF GLASS, AND PLATED PARTS

Do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth.

The glass is 3/16" ceramic glass available from your Napoleon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result.

SHIPPING BRACKET

To avoid the stove being damaged during shipping, a shipping bracket has been used and must be unbolted before the stove can be installed.

1.Remove the four nuts holding the shipping bracket to the bottom of the stove.

2.Lift the stove up and away from the skid to clear the threaded bolts sticking through the bracket. Set down on a flat surface. The stove top is not secured to the unit.

3.Discard the nuts, bracket and the skid.

FIGURE 1

4 NUTS

SHIPPING

BRACKET

GDS60: TOP VENT / REAR VENT VERTICAL TERMINATION: Maximum input is 35,000 BTU/hr for natural gas and 31,500 BTU/hr for propane. Maximum output for natural gas is 27,300 BTU/hr at an efficiency of 78%. Maximum output for propane is 24,570 BTU/hr at an efficiency of 78%. Maximum A.F.U.E. (annual fuel utilization efficiency) rating is 72% for natural gas and 71% for propane.

REAR VENT HORIZONTAL TERMINATION: Maximum input is 21,000 BTU/hr for natural and propane gas. This application requires changing the main burner orifice.

This stove is not approved for closet or recessed installations. It is approved for bathroom, bedroom and bedsitting room installations.

This stove may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.

GS60: Maximum input is 35,000 BTU/hr for natural gas and 31,500 BTU/hr for propane. This stove is ap-

proved for bedroom and bed-sitting room installations.

5

LOCATION & CLEARANCES

Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the stove.

Never obstruct the front opening of the stove.

GDS60 AND GS60

As long as clearance to combustibles is kept within the required distances, the most desirable and beneficial location for a Napoleon stove is in the centre of a building, thereby allowing the most efficient use of the heat created. The location of windows, doors and the traffic flow in the room where the stove is to be located should be considered. If possible, you should choose a location where the vent will pass through the house without cutting a floor or roof joist.

MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:

FIGURE 3

A. 6" B. 6" C. 2"*

NO ADDITIONAL FLOOR PROTECTION IS REQUIRED

MINIMUM 20" FROM STOVE TOP TO CEILING

6" TO SINGLE WALL CONNECTOR

1" TO DIRECT VENT AND B-VENT

*AT A DISTANCE OF 2" FROM THE WALL, ACCESS TO THE BLOWER SWITCH, ON-OFF SWITCH OR THE BLOWER POWER CORD MAY NOT BE PRACTICAL.

A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. Local codes or regulations may require different clearances.

Donotallowtheinsidelinertobunchuponhorizontal orverticalrunsandelbows.Keepitpulledtight.A 1-1/ 4"airgapallaroundbetweentheinnerlinerandouter stovepipeisrequiredforsafeoperation.Useafirestop when penetrating interior walls, floor or ceiling.

FIGURE 2 - SHOWN WITH OPTIONAL FRONT INSTALLED

NOTE: The total width of the stove is increased to 39" width with the optional side shelves attached.

W415-0158 / E / 02.19.04

FIGURE 4

6

DIRECT VENT SPECIFICS - MODEL GDS60

VENTING LENGTHS &

AIR TERMINAL LOCATIONS

Use only Wolf Steel or Simpson Dura-Vent Model DV-GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, follow the installation procedure provided with the venting components. Both Wolf Steel and Simpson Dura-Vent venting components may have a 0" rise per foot on horizontal runs.

When using Wolf Steel venting components, use only the following vent kits: WALL TERMINAL KIT GD175 (7-1/2' of venting included), or 1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD110, 8/12 TO 12/12 ROOF TERMINAL KIT GD111, FLAT ROOF TERMINAL KIT GD112 or STOVE PERISCOPE KIT GD180 (for wall penetration below grade) in conjunction with the appropriate venting components.

For optimum performance, it is recommended that all horizontal runs have a minimum ¼ inch rise per foot.

These vent kits allow for either horizontal or vertical venting of the stove. The maximum number of 4" flexible connections is two horizontally or three vertically (excluding the stove and the air terminal connections).

When terminating vertically, the minimum vertical rise is 34 inches above the stove and the maximum vertical rise is 40 feet. FIGURE 4.

Deviation from the minimum vertical vent length can create difficulty in burner start-up and/or carboning.

Use an adjustable pipe as the final length of rigid piping to the stove for ease of installation.

For optimum flame appearance and stove performance, keep the vent length and number of elbows to a minimum. The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.

The maximum horizontal run is 34 inches with a 90o elbow located 29" above the stove. FIGURE 5.

The maximum horizontal run with a 57 inch vertical rise immediately above the stove is 20 feet . FIGURES 6a & b.

IF VERTICAL RISES GREATER THAN 57 INCHES ARE NECESSARY, THE INCREASED RISE MUST BE DEDUCTED FROM THE MAXIMUM HORIZONTAL RUN.

FIGURE 5

FIGS6a-b

HORIZONTAL RUN NOT TO

EXCEED VERTICAL RISE

Use the chart on this page to calculate horizontal runs for vertical rises between 29 and 57 inches. When calculating maximum run lengths, include 5 feet for each 90° or 45° elbow.

(DO NOT INCLUDE THE FIRST ELBOW DIRECTLY OFF THE UNIT.)

R E Q U I R E D

V E R T I C A L

RISE FROM

FIREPLACE

TO FIRST EL-

BOW IN

INCHES

FIGURE 7

CALCULATED HORIZONTAL VENT RUN IN FEET

W415-0158 / E / 02.19.04

7

AIR TERMINAL INSTALLATIONS

FIGURE 8

 

INSTALLATIONS

 

 

CANADIAN

U.S.A.

 

A

12 INCHES

12 INCHES

Clearance above grade, veranda porch, deck or balcony.

 

 

 

 

B

12 INCHES

9 INCHES

Clearance to windows or doors that open.

 

 

 

 

C

12 INCHES*

12 INCHES*

Clearance to permanently closed windows.

 

 

 

 

D

18 INCHES**

18 INCHES**

Vertical clearance to ventilated soffit located above the terminal within

a horizontal distance of 2 feet from the centerline of the terminal.

 

 

 

 

E

12 INCHES**

12 INCHES**

Clearance to unventilated soffit.

 

 

 

 

F

0 INCHES

0 INCHES

Clearance to an outside corner wall.

 

 

 

 

 

0 INCHES***

0 INCHES***

Clearance to an inside non-combustible corner wall or protruding

 

non-combustible obstructions (chimney, etc.).

G

 

 

 

2 INCHES***

2 INCHES***

Clearance to an inside combustible corner wall or protruding com-

 

 

bustible obstructions ( vent chase, etc.).

 

 

 

 

H

3 FEET

3 FEET****

Clearance to each side of the centerline extended above the meter

/ regulator assembly to a maximum vertical distance of 15ft.

 

 

 

 

 

 

 

I

3 FEET

3 FEET****

Clearance to a service regulator vent outlet.

 

 

 

 

J

12 INCHES

9 INCHES

Clearance to a non-mechanical air supply inlet to the building or a

combustion air inlet to any other appliance.

 

 

 

 

 

 

 

K

6 FEET

3 FEET†

Clearance to a mechanical air supply inlet.

 

 

 

 

L

7 FEET‡

7 FEET****

Clearance above a paved sidewalk or paved driveway located on

public property unless fitted with a heat shield kit GD-301.

 

 

 

 

 

 

 

 

 

 

 

M

12 INCHES††

12 INCHES****

Clearance under a veranda, porch, deck or balcony.

 

 

 

 

N

16 INCHES

16 INCHES

Clearance above the roof.

 

 

 

 

O

2 FEET†*

2 FEET†*

Clearance from an adjacent wall including neighbouring buildings.

 

 

 

 

 

*Recommended to prevent condensation on windows and thermal breakage

**It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.

***The periscope GD-201 requires a minimum 18 inches clearance from an inside corner.

****This is a recommended distance. For additional requirements check local codes.

Three feet above if within 10 feet horizontally.

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single f

dwellings and serves both dwellings.

††Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the floor.

†* Recommenced to prevent recirculation of exhaust products. For additional requirements check local code

W415-0158 / E / 02.19.04

8

SPECIAL INSTALLATION EXAMPLE

 

OFFSET INSTALLATION EXAMPLE

 

 

 

When a horizontal offset is required in a through-the-roof installation, the following procedure for vent length calculations must be followed:

In an installation as shown in FIGURES 9 & 12, lengths A and C are known based on room height and roof requirements.

Length C must never be less than 29 inches. Any 90° and 45° elbows must be calculated as 5 feet of venting each.

The allowable horizontal run can be calculated using these parameters. In this example, the total vertical height is 20 feet (length "A" is required to be 11 feet while length "C" needs to be 9 feet). The maximum vertical length is 40 feet and all runs and elbows must be sub-

tracted from this maximum vertical FIGURE 9 length.

The maximum allowable horizontal run that "B" can be is:

40 ft. (maximum vertical run length) -11 ft. (through the roof vertical rise "A") -10 ft. (2 - 90° elbow)

- 9 ft. (vertical run "C")

10 ft. (maximum allowable horizontal length for "B")

The length of "B" must never be greater than the length of "A" and "C" combined.

The maximum allowable horizontal run that "A" in Figure 13 can be is:

40 ft. (maximum vertical run length)

- 7 ft. (horizontal run "B")

33 ft. (maximum allowable vertical length for "A")

FIGURE 10

If a first run of 120 inches is required, using the "First Vent Run" on the chart shows that a maximum second run of 60 inches is allowable.

IF NECESSARY, THE FIRST

FIGURE 11

RUN AND THE SECOND

RUN MAY BE REVERSED.

FIGURE 12

FIGURE 13

W415-0158 / E / 02.19.04