INSTALLATION INSTRUCTIONS

HARDWIRE

WIRELESS

G E M - P 1 6 6 4

CONTROL PANEL/COMMUNICATOR

For use with "Classic" keypads (GEM-RP1CAe2, GEM-RP2ASe2, GEM-RP3DGTL and GEM-RP4RFC/GEM-RP4C) and with "K Series" keypads (GEM-K1CA, GEM-K2AS, GEM-K3DGTL, and GEM-K4RF/GEM-K4)

GEMINI

SYSTEM READY 09/01/05 12:00 AM

 

 

 

S

 

 

 

 

 

TU

 

 

 

A

 

 

 

 

ED

ST

 

 

 

 

 

 

 

 

 

 

NEXT/YES

RM

 

 

 

 

 

A

 

R 1 2 3

U

 

 

P

 

 

B 4 5 6

PRIOR/NO

 

 

 

Q

 

 

 

 

 

 

 

AREA

C 7 8 9 0 G

COMPUTERIZED SECURITY SYSTEM

"K Series" GEM-K1CA

GEMINI

32 ENT A1

INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

NEXT/YES

RA123

B456

AREA

C7890G

COMPUTERIZED SECURITY SYSTEM

R

"K Series" GEM-K3DGTL

 

GEMINI

SYSTEM ARMED

 

 

 

 

01/01/97AC ON12:00AMREADY

 

 

 

 

AC ON READY

 

 

 

S

 

 

 

TU

 

 

TA

 

 

DS

 

 

 

ME

 

 

 

NEXT/YES

AR

 

 

 

 

 

 

A123

 

 

 

R

 

B456

AREA

C7890G

COMPUTERIZED SECURITY SYSTEM

R

"K Series" GEM-K2AS

"K Series" GEM-K4RF

© NAPCO 2006

 

WI1424A 1/06

THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN GEM-P1664 CONTROL PANEL FIRMWARE VERSION 1.0 OR LATER.

IMPORTANT NOTICE

GEM-P1664 panel version 01 requires the use of the following version keypads:

GEM-RP1CAe2 Version 9A, GEM-K1CA Version 9A

GEM-RP2ASe2, Version 7, GEM-K2AS, Version 7

GEM-RP3DGTL, Version 3, GEM-K3DGTL, Version 3

GEM-RP4RF, Version 2, GEM-K4/K4RF, Version 2

Upon entering program mode, the keypad display will flash the control panel firmware version, followed by the keypad firmware version:

GEM-RP1CAe2: [019A], GEM-RP2ASe2: [0107], GEM-RP3DGTL: [0103], GEM-RP4RF: [0102] GEM-K1CA: [019A], GEM-K2AS: [0107], GEM-K3DGTL: [0103], GEM-K4/K4RF: [0102]

For consistency, it is recommended that all keypads either be all "classic" (such as the GEM-RP1CAe2 keypad) or all "K Series" (such as the GEM-K1CA)--both keypad types should not be used in one alarm system.

CHANGES FROM PREVIOUS EDITION

The following changes have been made to this manual (WI1424A) since the previous edition (WI1424):

Page 6: Specifications: Current ratings updated.

Page 59: Wiring Diagram updated.

Refer to accompanying GEM-P1664 Programming Instructions (WI1422 and WI1423) for programming information.

NAPCO Security Systems, Inc.

333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445

For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com

WI1424A

1/06

 

TABLE OF CONTENTS

 

INTRODUCTION.....................................................

4

General Description ................................................

4

Features..................................................................

 

4

Specifications..........................................................

6

Ordering Information ...............................................

7

Summary of UL Requirements ................................

8

INSTALLATION......................................................

9

Mounting

.................................................................

9

Wiring......................................................................

 

10

Wireless Systems....................................................

10

Typical Residential Fire Installation .........................

10

Typical Partitioned Installation.................................

10

TESTING THE SYSTEM.........................................

11

WIRING CONNECTIONS .......................................

12

Battery ....................................................................

 

12

Transformer ............................................................

12

Siren/Bell Output.....................................................

12

Auxiliary Power .......................................................

12

PGM Outputs ..........................................................

12

Remote Bus ............................................................

13

Earth Ground ..........................................................

13

Zone Configuration Styles .......................................

14

Basic Zone Configuration...................................

14

EZ Zone Doubling Configuration........................

14

Zone Expansion Device Compatibility .....................

15

4-Wire Smoke Detectors .........................................

15

2-Wire Smoke Detectors .........................................

15

Telephone Lines......................................................

16

KEYPAD CONFIGURATION MODE.......................

17

Keypad Installation..................................................

17

Configuring the Keypads .........................................

17

Page 3

BASIC OPERATION ...............................................

20

User Codes & Zone Descriptions.............................

20

Arming and Disarming the System...........................

21

Bypassing Zones .....................................................

23

Unbypassing Zones .................................................

23

Alarm Indication.......................................................

23

Function Mode/Dealer Program Mode .....................

23

KEYPAD MESSAGES.............................................

26

GLOSSARY ............................................................

27

STANDBY-BATTERY CALCULATION WORKSHEET

................................................................................

46

WIRING LEGEND ...................................................

47

KEYPAD PROGRAMMING MODES .......................

48

Function Mode.........................................................

48

Dealer Mode ............................................................

49

Easy Menu Mode.....................................................

50

User Mode ...............................................................

51

Keypad Configuration Mode.....................................

52

CP-01 QUICK REFERENCE CHART......................

53

FACTORY DEFAULT DESCRIPTION.....................

55

FCC STATEMENT ..................................................

57

GEM-P1664 WIRING DIAGRAM .............................

59

LIMITED WARRANTY.............................................

60

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Features

Page 4

WI1424A 1/06

INTRODUCTION

GENERAL DESCRIPTION

Napco's Gemini GEM-P1664 is a state-of-the-art microcomputer-based burglary and residential fire alarm control panel of modular design. Integrally an 8-zone panel, it will support up to 64 zones with the use of zone doubling, optional zone expansion modules, wireless receiver modules and/or GEM-RP1CAe2/GEM-K1CA Keypads. Each panel includes an integral digital communicator.

The control panel features programmable area partitioning. That is, the system may be divided into up to 4 discrete multiple-zone areas, each allowing access by only those users programmed for their respective area.

Opening Suppression and Closing Suppression, available through Napco Quickloader software, suppress reporting within programmed “windows”. Conversely, Exception Reporting can transmit a “fail to close” if the panel is not armed within programmed intervals and, similarly, a “fail to open” if the panel is not disarmed within programmed intervals. Furthermore, the panel can be programmed to automatically arm either area at any time. A log containing up to 400 events (accessible through QuickloaderTM software) monitors control-panel activity referenced to a precision real-time clock. A detailed event history may be displayed at the computer, using Napco’s PCD-Windows Quickloader Software.

Keypads feature a liquid-crystal display for messages. In normal use, the LCD shows zone identification and status messages, and the log can also be viewed. Conventional LEDs and a sounder are also provided for annunciation.

Data may be quickly and easily downloaded to the control panel using a PC-compatible computer with Napco's PCDWindows Quickloader software and PCI2000 computer interface. Or, the panel may be programmed using the keypad in its secondary mode of operation. In the keypad programming modes (there are two: Dealer and User), the LCD shows memory address, data values, programming prompts, and the alphanumeric characters required for entering up to 64 user codes and custom zone descriptions.

NOTE: Failure to install and program as described in this manual for UL-listed systems voids the listing mark of Underwriters Laboratories, Inc.

FEATURES

Control Panel Features

Eight end-of-line-resistor burglary zones programmable for Area (expandable to sixteen end-of-line resistors with zone doubling or series zone doubling with loop supervision), Exit/Entry Delay, Interior (Stay) Bypass, Exit/Entry Follower, Day Zone, Chime, Fire options, Swinger Shutdown, Zone Anding and a variety of other features.

Supports up to 64 zones with optional zone-expansion modules, wireless receiver modules and 4-zone keypads.

Supports up to 64 individually coded users.

Supports three outputs (Bell, PGM1 and PGM2) and up to 16 external outputs (using Relay Module RB3008, RM3008 or the GEM-OUT8. See Relay Control in glossary for more information).

Supports three keypad panics: Fire, Police & Auxiliary.

Supports four independent area partitions.

Supports up to seven separate access stations (keypads) by up to 64 users.

Supports up to 16 separately-addressable X-10 devices with the GEM-X10 KIT and PC04 interfaces.

English-language prompts & system status messages.

User Codes and Zone Descriptions outside assigned areas are able to be blocked from keypad display.

User-customized zone descriptions, re-programmable as required.

Supports 2-wire and 4-wire smoke detectors.

Reports alarms, restores and troubles by zone.

400 Event Log.

Two programmable entry delay times.

One Interior Zone Group.

Dynamic battery test interrupts charging and places battery under load every four hours.

Two Chimes by zone; programmable duration.

Quickloader programmable.

2 PGM outputs.

Supports Gemini Wireless Devices.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

WI1424A 1/06

Page 5

Communicator Features

Compatible with all major receiver formats, including 4/2, SIA and Point ID (except Radionics Modem II).

Rotary dial and TouchToneTM with Rotary backup.

Three 20-digit telephone numbers.

Backup Reporting; Double Reporting; Split Reporting.

64 User Codes with Opening/Closing -Reporting by user.

AC Failure Reporting with programmable report delay.

Supervised telephone line with a fixed 60 second delay.

Pager capability.

Keypad Features

English-language LCD display; LED and sounder annunciators.

Supports up to seven 4-wire keypads.

Provisions for fire, police and auxiliary panic alarms.

Integral 4-zone EZM included in each keypad (GEM-RP1CAe2/GEM-K1CA only).

Fault-Find diagnostics simplify troubleshooting.

SIA CP-01 Features.

See page 59 for complete information regarding how the Factory Program complies with the Security Industry Association False Alarm Reduction Control Panel-01 Standard (SIA FAR CP-01).

IMPORTANT NOTE

This manual supports the keypad programming of the GEM-P1664 control panel with the NAPCO "classic" GEMRP1CAe2, GEM-RP2ASe2, and GEM-RP3DGTL keypads as well as the GEM-K1CA, GEM-K2AS, and GEM-K3DGTL "K Series" keypads. The new "K Series" models offer the new STAY and AWAY buttons with simplified functionality, along with the new MENU and ENTER buttons.

While the instructions in this manual are depicted using the GEM-K1CA and GEM-K2AS keypads, the manual applies to both the "classic" and the "K Series" keypads.

Program Mode is the same for both keypads--only the button names have changed, as follows:

The Abutton and the Rbutton operate identically (in Program Mode) for both keypads.

The Dbutton and the Ubutton operate identically (in Program Mode) for both keypads.

The button and the button operate identically (in Program Mode) for both keypads. The words "NEXT/YES button" are used in this manual.

The button and the button operate identically (in Program Mode) for both keypads. The words "PRIOR/NO button" are used in this manual.

Features

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Specifications

Page 6

WI1424A 1/06

SPECIFICATIONS

GEM-P1664

Operating Temperature: 0-49°C (32-120°F)

Input Power: 16.5-18.0 VAC via CLASS 2 Plug-In 20VA, 40VA or 50VA Transformer

Loop Voltage: 10-13Vdc

Loop Current: 3mA without Zone Doubling, 2.4mA with Zone Doubling using a 2.2K Ohm end-of-line resistor (Model EOL2.2K); 5mA for 2-wire smoke-detector zones; 1.4 mA using a 3.9K Ohm resistor (Model EOL3.9K) with Zone Doubling; 3mA with Series Zone with Loop Supervision and 3mA with Series Zone Doubling with Loop Supervision

Loop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-detector zones Alarm Voltage Output: 1

Programmable Negative Outputs: 2

Auxiliary Power Output: 11.7-12.5 VDC

Remote Power Output: 12 VDC regulated (for keypads)

Combined Standby Current (Remote Power + Aux. Power + Fire Power): See following charts.

RESIDENTIAL BURGLARY & COMMERCIAL BURGLARY**

16.5VAC

BATTERY

STANDBY

ALARM

STANDBY

TRANSFORMER

(12 VDC)

CURRENT

CURRENT

TIME

 

 

 

 

 

40VA/50VA

7 AH

550 mA

550 mA(1)

4 Hours

20VA*

7 AH

500 mA

2.0 A

4 Hours

 

 

 

 

 

20VA*

7 AH

500 mA

2.0 A

6 Hours

 

 

 

 

 

 

 

 

 

COMBINATION RESIDENTIAL FIRE & RESIDENTIAL BURGLARY

 

 

 

 

 

 

16.5VAC

BATTERY

STANDBY

ALARM

STANDBY

TRANSFORMER

(12 VDC)

CURRENT

CURRENT

TIME

 

 

 

 

 

40VA/50VA

7 AH

120 mA

520 mA(1)

24 Hours

40VA/50VA *

Two 7 AH

360 mA

280 mA(1)

24 Hours

20VA *

7 AH

120 mA

360 mA(1)

24 Hours

20VA *

Two 7 AH

360 mA

120 mA(1)

24 Hours

NOTE: (1) Alarm current can be increased by reducing standby current by the same amount.

*Not evaluated by UL.

**Commercial Burglary specifications not evaluated by UL.

FOR ALL UL INSTALLATIONS

"ENABLE RESIDENTIAL FIRE" (ADDRESS 1422) MUST BE PROGRAMMED

The feature "Enable Residential Fire" (address 1422, option 4 / bit 3) must be programmed for ALL UL installations. To program, please refer to the GEM-P1664 Programming Instructions (WI1422 and WI1423) for further information.

EZM Module: GEM-EZM816: Input, 50mA

Keypad Current: GEM-RP1CAe2: 100mA; 35mA if back lighting is disabled (cut W1, W2 & W3).

PGM Output: 5mA, 12V Special Application

Maximum Number of Keypads: 7

Maximum Wiring Length for each run (#22AWG): 1000' divided by total number of keypads and

EZMs on run

Keypad Dimensions: 4” x 5” x 1” (HWD); 11.1cm x 14.9cm x 2.7cm (HWD)

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

WI1424A 1/06

ORDERING INFORMATION

System Components

GEM-P1664: Residential UL-Listed Burg and Fire Control Panel.

GEM-RP1CAe2: 32-Character LCD Burg & Fire Keypad with 4 EOL Zones.

GEM-RP2ASe2: LCD Burg & Fire Keypad with remote panic.

GEM-RP3DGTL: Burg & Fire Keypad.

GEM-RP4RFC: Digital Icon Burg & Fire Keypad with Integral RF Receiver.

GEM-RP4C: Digital Icon Burg & Fire Keypad.

GEM-K1CA: 32-Character LCD Burg & Fire Keypad with 4 EOL Zones.

GEM-K2AS: LCD Burg & Fire Keypad with remote panic.

GEM-K3DGTL: Burg & Fire Keypad.

GEM-K4RF: Digital Icon Burg & Fire Keypad with Integral RF Receiver.

GEM-K4: Digital Icon Burg & Fire Keypad.

Optional Accessories and Peripherals

GEM-EZM8: 8 Zone Expansion Zone Module GEM-EZM816: 4-16 Zone Expansion Zone Module GEM-EVA 1: Electronic Voice Annunciator GEM-RECV8: Wireless Receiver, 8 Zones GEM-RECV16: Wireless Receiver, 32 Zones GEM-RECV96: Wireless Receiver, 64 Zones GEM-TRANS2: Window/Door Transmitter, 2-Point GEM-RTRANS: Recessed Window/Door Transmitter GEM-KEYF: Key Fob Transmitter

GEM-SMK: Wireless Smoke Detector GEM-PIR: Wireless PIR

GEM-PIRPET: Wireless Pet Immune Transmitter* GEM-RS232: Isolated Comuter Interface GEM-DT: Wireless Dual-Technology Sensor GEM-GB: Wireless Glass-Break Detector* GEM-X10KIT: X-10 Interface*

GEM-OUT8: 8 output active low output module

GEM-TEMP64: GEM-P1664 indoor/outdoor programmable temperature sensor*

RM3008: Relay Module (in enclosure) M278: Line-Reversal Module

PS3002: Power-Supply Module, 13.2Vdc, 1.9A* EOL2.2K: End-of-Line Resistor Assy., 2.2k Ohm

EOL3.9K: End-of-Line Resistor Assy., 3.9k Ohm for Zone Doubling

EOL4.7K: End-of-Line Resistor Assy., 4.7k Ohm FT2200: End-of-Line Relay/Resistor Supervisory Module RB1000: Relay Board, single output*

RBATH1: Dual Battery Harness RPB-3: Universal Keypad Mounting Box

TRF11: Transformer, 16.5Vac/40VA, Class 2 TRF14: Transformer, 16.5Vac/50VA, Class 2 WL1: Wire Assembly with Lug Connector, 20”

Page 7

VERI-PHONE: Two-Way Voice/Listen-In Module

PCD-Windows: Downloading Software (for Windows) for IBM PC-Compatible, V5.0 or greater

PCI2000/3000: Software Interface for IBM PCCompatible Computer*

PCI-MINI: Notebook Computer Interface* W834-1: Keypad Cable, plug-in (20”) OI193: User Guide, GEM-RP1CAe2 OI192: User Guide, GEM-RP2ASe2 OI249: User Guide, GEM-RP3DGTL OI278: User Guide, GEM-RP4C & RP4RFC WI1212: Installation Manual, GEM-RP4C

WI1128: Installation Manual, GEM-RP4RFC OI279: User Guide, GEM-K1CA

OI280: User Guide, GEM-K2AS OI281: User Guide, GEM-K3DGTL OI283: User Guide, GEM-K4 & K4RF WI1178: Installation Manual, GEM-K4

WI1179: Installation Manual, GEM-K4RF

WI1422: GEM-P1664 Programming Instructions (using

GEM-RP1CAe2 / GEM-K1CA keypads).

WI1423: GEM-P1664 Programming Instructions (using

GEM-RP2ASe2 / GEM-K2AS or GEM-RP3DGTL /

GEM-K3DGTL keypads).

WI1424: GEM-P1664 Installation Instructions

WIZARD IIe: Telephone Interface Module*

*Not Investigated by UL

UL Listings

Household Burglar Alarm System Units: UL1023 Household Fire Warning System Units: UL985

Security Industry Association (SIA) False Alarm Reduction Standard CP-01

** Pending

Napco Group Europe Ltd.

Libra Wireless Transmitters and Receivers for connection to Napco Intruder Control Panels (Operates on 433MHz, European Approved Frequency)

WI925: LIBRA-RECVXP-433 Wireless 8 Zone Receiver

WI924: LIBRA-RECV8-433, LIBRA-REC16433, LIBRA-

REC96433, Wireless 8/16/96 Zone Receiver

WI923: LIBRA-TRANS433, Wireless Door Contact

WI929: LIBRA-PIR433, Wireless PIR

WI931: LIBRA-KEYF433, Wireless KeyFob

WI930: LIBRA-SMK433, Wireless Smoke Detector

WI928: LIBRA-GB433, Wireless Glass Break Sensor

Information Ordering

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Smoke detectors & Summary of UL Requirements

Page 8

WI1424A 1/06

Smoke Detectors, 4-Wire:

1.ESL 445AT, 445C, 445CT, 445CR, 445CRT

2.Hochiki America SLG-12 with YBC-RL4-RA Base

3.System Sensor 2312/24T; 1412; 1412TH; 2412TH

Subtract total smoke-detector alarm current from available standby current.

Note: Any normally-open devices that do not require power from the control panel, such as pull stations and thermostats may be used if acceptable to the Authority having Jurisdiction.

UL Compatible Smoke Detectors (Providing UL Recognition or Listing)

Manufacturer

 

4-Wire

 

2-Wire

Smoke Detector

 

Smoke Detector

Smoke Detector *

Base

 

 

 

 

 

 

Napco

 

FW-4

 

FW-2

 

 

 

 

 

 

 

Sentrol

449AT

449CLT

712U

731U

701U

 

449C

449CSLT

722U

 

702U

 

449CRT

449CTE

732U

 

702RE

 

449CST

741U

711U

 

702RU

 

449CSRT

742U

721U

 

 

 

449CSRH

 

721UT

 

 

 

449CSST

 

 

 

 

 

 

 

 

 

 

System

1112

2112T

2100

1100

 

Sensor

2112

2112TSRB

2100T

 

 

 

 

 

 

 

 

Note: * Voltage Rating: 8.5-13.3 VDC, Maximum Number of Detectors: 10

SUMMARY OF UL REQUIREMENTS

Residential

Recognized Limited-Energy Cable for initiating, indicating and supplementary circuits.

Initiating loops supervised if longer than 3 feet

FT2200 End-of-Line Relay for Fire (if using 4-wire smoke detectors)

Minimum alarm timeout of 5 minutes

Maximum exit time: 60 seconds

Maximum entry time: 45 seconds

Do not program “Swinger Shutdown”, “Force Arming”, “Selective Bypass” or “50 ms Loop Response”

“Abort Delay” may not exceed 45 seconds

Program “Disable Callback Download”

Automatic dialer may not dial a police station number that has not been dedicated for such service

System must be tested at least weekly under AC/battery and Battery-Only conditions

Replace the rechargeable battery at least every 5 years

If the battery is heavily discharged, replace it or have it tested by a qualified technician

For silent panic, connect only to UL-listed holdup devices

All zones must be programmed for “Priority”

Do not program any zones for “Keyswitch Arming”

System must be serviced at least once every year

Residential Fire and Combination Residential Fire & Burglary must program “Residential Fire”

Keypad Expansion (EZM) Zones are not to be used as fire zones

Keypad Auxiliary is not to be selected

The GEM-K Series Keypads must have the indicators printed on the face label (Fire, Police and Auxiliary) covered by a supplied label if not in use.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

WI1424A 1/06

Page 9

INSTALLATION

CAUTION: This equipment generates and uses radio-frequency energy. If not installed using conventional installation practices for RF devices, it may cause interference to radio and television reception. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference. However, there is no guarantee that interference will not occur in a particular installation. If it has been found to cause interference to radio or television reception, which can be determined by removing and reapplying AC and battery power to the equipment, the installer should try to correct the interference by one or more of the following measures: reorient the receiving antenna; connect the power transformer to a different outlet so that the control panel and receiver are on different branch circuits; relocate the control panel with respect to the receiver.

MOUNTING

Control Panel

Choose a mounting location accessible to (a) a continuously-powered AC source, (b) system ground, a steel or copper ground rod, ideally no further away than 10 feet, and (c) telephone lines (keep telephone wiring away from keypad wires). Remove appropriate knockouts for cables. Place the control panel at a convenient viewing height and mark the mounting holes. Attach the enclosure using screws suitable for the mounting surface.

Grounding

Connect the control-panel grounding screw to a metal cold-water pipe or a long steel (or copper) ground rod driven deeply into the earth. Do not use a gas pipe, plastic pipe or AC ground connections. Use at least 16-gauge wire. Make the run as short and direct as possible, without any sharp bends in the wire.

Keypad

A keypad should be located near each exit/entry door. The keypad features a handy pull-up reference label. Before mounting the keypad onto the wall, push the Sliding Label Plate (with label and felt backing affixed and handle facing forward) down the guides at the rear of the keypad until it snaps into place. Once installed, the Sliding Label Plate cannot be removed without first removing the keypad from the wall. Note: (1) The keypad fire and panic keys should not be considered a substitute for a listed manual initiating device, such as a pull box. (2) Each GEM-RP1CAe2 includes provisions for four additional zones. See ADDING EXPANSION ZONES.

If installing onto a double-gang box, insert mounting screws through the two vertical elongated holes on the left side of the case and into the box. If the box is visible when viewed from the front, adjust the keypad vertically and tighten the screws. Then, using hardware suitable for the mounting surface, add one or two screws at the right side of the keypad case directly into the wall to ensure a secure installation. Note: Do not overtighten the screws! Uneven walls may cause the keypad case to distort.

Mounting

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Wiring

Page 10

WI1424A 1/06

Wiring

Wire keypad(s), zones, expansion zone modules and output devices as shown on the Wiring Diagram. Note that the Wiring Diagram contains important information not available elsewhere in this manual.

CAUTION: Do not run telephone wiring near speaker wires; do not run keypad wiring with loop wiring.

Adding Expansion Zones

GEM-P1664 control panel can support up to 16 zones as is, however this number may be increased to as many as 64 programmable zones using optional expansion zone modules (EZMs).

Wireless Systems

With the addition of at least one GEM-RECV series receiver, the GEM-P1664 will support up to 64 wireless transmitters. The panel can accommodate one or two receivers within the premises, responding to the one with the stronger transmitter signal. If any transmitters are selected for the default program, a GEM-RECV receiver will automatically be programmed.

The keypad can display the status of any transmitter, indicating the condition of the zone (normal or open) and transmitter troubles (low battery, tamper or supervisory failure), and signal strength of the last transmission. A receiver failure will be indicated by “E06-NN” (“no response”, with NN representing the receiver number).

TYPICAL RESIDENTIAL FIRE INSTALLATION (Where permitted by local codes)

At least one smoke detector should be installed directly outside each sleeping area. If there is more than one floor, additional smoke detectors should be installed on each level, including the basement. The living-area and basement smoke detectors should be installed near the stairway of the next upper level. For increased protection, additional detectors should be installed in areas other than those required, such as the dining room, bedrooms, utility room, furnace room, and hallways. Heat detectors, rather than smoke detectors, are recommended in kitchens, attics, and garages due to conditions that may result in false alarms and improper operation. Large areas and areas with

partitions, ceiling beams, doorways, and open joists will require additional detectors.

Refer to NFPA Standard No. 74 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) for additional information, including proper mounting of detectors.

TYPICAL PARTITIONED INSTALLATION

(4 Partitions Available)

Described and illustrated here are an example of a partitioned system with common-area protection of the control-panel room. This system meets UL requirements for a partitioned system.

All areas must be owned and managed by the same person(s).

All areas must be part of one building at one street address.

The control panel and all wiring protecting each partitioned area must be confined to the respective area and may not impinge upon the other area. This requires that the control panel room have redundant protection; that is (a) multiple sets of door contacts, each wired to a

separate zone and (b) one of those zones programmed for each area. In order to gain access to this protected area without causing an alarm, both partitions must be disarmed. In lieu of redundant protection, 24-Hour Zones may be used. Any zone protecting the control panel and transformer may not be programmed for bypass.

The sounding device must be placed such that the bell test can be heard by all partitions. Note: NFPA 74 (Household Fire Warning Equipment) requires that a fire alarm audible device be installed indoors.

The User Program Code is not to be given to anyone except the authority responsible for all partitions.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

WI1424A 1/06

Page 11

TESTING THE SYSTEM

After installation is completed, test the system as follows.

1.Call the central station to inform them of the test.

2.Initiate an alarm, preferably on a zone that activates a steady siren, and verify proper signalling.

3.Call the central station to confirm their receipt of a good transmission.

Note: Be sure to test all enabled keypad panics.

Signal Strength Testing/Wireless Systems

To test the operation of wireless transmitters, proceed as follows.

1. Enter the Fault-Find Mode. (See Dealer Mode on page 52. Panel must be disarmed).

2. Fault a point of the transmitter to be tested by opening the loop. If the signal strength of the transmitter is 3 or greater, the keypad will beep, as follows:

Signal Power

Beeps

0-2

0

3

1

4-5

2

6-7

3

8-10

4

3. Restore the wireless point (close the loop).

The transmitter signal strength will be displayed on a scale of 3-10 with 3 considered marginal and 10 considered excellent. Note that if the signal strength is less than 3, the keypad will not beep and the strength will not be displayed. Except in the Fault-Find Mode, signal strengths less than 3 will be entered into the system log. Upon zone restore, the keypad will beep once.

System the Testing

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Wiring Connections: Battery, Transformer, Siren Power, Aux. Power & PGM Outputs

Page 12

WI1424A 1/06

WIRING CONNECTIONS

BATTERY

7

The RED (+) and BLACK (-) flying leads must be connected to a 12VDC 4-7 AH Rechargeable Battery, to serve as backup power in the event of AC Power Failure. NOTE: To calculate the available standby time refer to the StandbyBattery Calculation Worksheet at the back of this manual.

TRANSFORMER

(The following applies to installations in the United States of America): Connect a 16.5 VAC Transformer to Terminals 1 and 2, using a wire of #18 AWG. or larger at a distance of 15 ft. or less from the control panel. NOTE: Do not connect to a switched outlet.

SIREN/BELL POWER

Connect the alarm sounding devices (self-contained sirens,

 

speakers or a mechanical bell) to Terminals 3 and 4. Any self-

 

contained siren requiring a 12 VDC input can be connected.

 

When connecting a mechanical bell, it must be supervised

 

using a 2.2k Ohm resistor. To connect 8 Ohm Speakers use a

 

Siren Driver with the proper polarity observed. NOTE: Refer to

 

the GEM-P1664 Wiring Diagram for alarm current

 

specification. Note: In NFPA Household Fire Installations.

 

only a single siren or bell can be used on this bell circuit.

AUXILIARY POWER

Connect the auxiliary devices (motion detectors, glass breaks, etc.) to Terminals 5 and 6. Auxiliary Power provides 11.7-12.5 VDC nominal output which is used for powering auxiliary devices. NOTE: To calculate the available standby time refer to the Standby-Battery Calculation Worksheet at the back of this manual.

PGM OUTPUTS (PGM1 & PGM2)

PGM1 and PGM2 are negative switched programmable outputs that can be activated depending on the programming options selected (see GEM-P1664 Programming Instructions). Connect the device controlled by the programmable output between terminal 5

(+) and the PGM output (-), either terminal 7 or 8. As an example, the connection to the RB1000 Relay Module is shown.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

WI1424A 1/06

Page 13

REMOTE BUS

REMOTE BUS

ADDITIONAL

EZMs

Example:

(GEM-RP1CAe2) 2 LINE KEYPAD

 

ATUS

 

 

 

 

 

D

ST

ARME

 

 

 

 

 

 

 

NOTE: Refer to the EZM Installation Instructions for specific wiring information.

AVAILABLE DEVICES

AVAILABLE DEVICES

1. KEYPADS: GEM-RP2AS & GEM-1RP1CAe2. KEYPADS: GEM-RP1CAe2, GEM-RP2ASe2, GEM-RP3DGTL, GEM-

2. X-10 INTERFACE: GEM-X10

RP4 series, GEM-K1CA, GEM-K2AS, GEM-K3DGTL, GEM-K4 series,

3. WIRED ZONE EXPANDER: GEM-EZM816

 

 

(7 maximum)

 

4. WIRELESS RECEIVERS: GEM-RECV8, GEM-RECV16 & GEM-RECV96

5. RELAY MODULE: RM3008

2. X-10 INTERFACE: GEM-X10 (16 devices maximum)

6. VOICE INTERFACE: GEM-EVA

 

EXPANDER: GEM-EZM4/8EX, GEM-EZM4/8 (64

7. TELEPHONE INTERFACE: WIZARD23. WIRED ZONE

zones maximum)

4. WIRELESS RECEIVERS: GEM-RECV8, GEM-RECV16, GEMRECV96 (64 zones maximum)

5. RELAY MODULE: RM3008 (16 relays maximum)

6. VOICE INTERFACE: GEM-EVA 1

7. TELEPHONE INTERFACE: WIZARD IIe

Connect the available devices as shown above to the remote bus terminals (9, 10, 11 & 12). Observe the correct color wire connections. When connecting the keypads, first configure them accordingly (refer to the Keypad Configuration Mode at the back of this manual). Keypads should be located near every exit/entry door. Up to seven keypads may be connected if the longest cable run from the panel, to the farthest keypad (daisy chained or homerun) is less than 1000 feet. The maximum distance for seven keypads is 300 feet using 22 AWG. wire. NOTE: When running keypad wire, avoid wiring parallel to other types of wiring.

EARTH GROUND

Connect the control panel EARTH GROUND screw to a metal cold-water pipe using at least a #16 AWG. wire. Do not use a gas pipe, plastic pipe or AC ground connections. Also, connect the circuit board to the metal enclosure. Connect a wire with a ground lug crimped or soldered onto one end of the EARTH GROUND screw to the cabinet. NOTE: Grounding connections should avoid bends in the grounding wire whenever possible.

NOTE: Do not use a gas pipe, plastic pipe or AC ground connections.

Ground Earth & Bus Remote Connections: Wiring

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Page 14
BASIC ZONE CONFIGURATION
( – )

Wiring Connections: Basic Zone Configuration & EZ Zone Doubling Configuration

WI1424A 1/06

The basic zone configuration for the GEM-P1664 is 8 zones. Connect as shown above to terminals 13-24. Normally Closed (N.

C.) devices may be wired in series or Normally Open (N.O.)

devices may be wired in parallel. Use the 2.2K Ohm end-of-line (E.

O.L.) resistor in each zone, if selected in programming (refer to the

GEM-P1664 Programming Instructions). Zones 1-8 can be

selected for a “Fast Loop Response (50 ms)” or a “Normal Loop

Response (750 ms)”. Other zone options include Zone Type (Entry/

Exit, Interior, 24 Hour Protection, Trouble and Fire), Instant, Chime, Area Selection and PGM Output selection. Additional expansion

zone modules or wireless sensor transmitters/receivers can be used to obtain zones numbered 9 through 32.

EZ ZONE DOUBLINGTM CONFIGURATION

The control panel zone configuration may be expanded from 8 to 16

zones without the use of EZM Modules. To do so simply select “EZ

Zone Doubling” in programming (refer to the GEM-P1664

Programming Instructions) and connect zones as shown above.

NOTE: If both zones in a zone-pair configuration (ex: zones 1 & 9 in

the above diagrams) are to be used, then normally closed devices

must be wired to both zones. The 3.9K EOL resistor must be placed

at the end of the loop of the higher zone and the 2.2K EOL resistor

must be placed at the end of the loop of the lower zone.

If Normally open zones for fire or panic devices are required, then

the lower zone (2.2K EOL resistor) must be used and the higher zone (3.9K EOL resistor) must not be programmed for any area.

Additional expansion zone modules or wireless sensor transmitters/receivers can be used to obtain zones numbered 9 through 32

WARNING: Assigning a fire zone or keyswitch zones to a zone doubled will disable the respective complimentary zone. For example, if zone 8 is assigned as a fire zone, it will disable zone 16. If zone 3 is assigned as a fire zone, it will disable zone 11.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

Napco Security Technologies GEM-P1664 User Manual

WI1424A 1/06

Page 15

4-WIRE SMOKE DETECTORS

4-WIRE SMOKE DETECTOR WIRING

The GEM-P1664 can use conventional 12 VDC 4-wire smoke detectors. To use them, select fire zone programming option and do not select 2-wire smoke detector programming option for the desired fire zone (refer to the GEM-P1664 Programming Instructions). Set JP3 to the position as shown, if zones 7 or 8 are to be used.

Four wire smoke detectors may be connected to any programmed fire zone (1-8) as shown, within the panel. If the Zone Doubling is used (see EZ Zone Doubling Configuration), the respective complementary zones (9-16) are disabled when 4- wire smoke detectors are connected to zones 1-8. If external EZMs are used for zones 9-64, then 4-wire smoke detectors may be connected to any programmed fire zones (9-64).

Power must be obtained from terminal 25 and 6. If Fire Alarm Verification is desired to reset the smoke detectors, select this option for the desired fire zone.

2-WIRE SMOKE DETECTORS

2 -W IR E S M O K E

D E T E C T O R W IR IN G

Two-wire smoke detectors can only be connected to zones 7 and 8. To use them, select fire zone programming option and select 2-wire smoke detector programming option for the desired fire zone 7 or 8 (refer to the GEM-P1664 Programming Instructions) and set JP3 to the “2-WF” position as shown. Connect the 2-wire smoke detectors as shown.

If the Zone Doubling is used (see EZ Zone Doubling Configuration), the respective complementary zones (15 & 16) are disabled when 2-wire smoke detectors are connected to zones 7 & 8.

If Fire Alarm Verification is desired to reset the smoke detectors, select this option for the desired fire zone (zone 7 or 8).

Detectors Smoke Wire-2 & Detectors Smoke Wire-4 Connections: Wiring

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Wiring Connections: Telephone Lines

Page 16

WI1424A 1/06

TELEPHONE LINES

RING TIP RING TIP

Model 368 Cord

RING

TIP

Connect the Model 368 Cord as follows: 26 (RED = Telco Ring), 27 (GREEN = Telco Tip), 28 (GRAY = Home Ring) and 29 (BROWN = Home Tip). Insert the modular plug into an approved USOCRJ31X jack (or a CA31A jack for Canadian installations). The Telco Line is used by the control panel to dial the central station and for downloading. This line should not be connected to party lines or coin operated telephones. If connected to a line with call waiting, then call waiting interrupt numbers must be programmed into the CS Telephone Numbers (refer to the GEM-P1664 Programming Instructions).

When communicating to central station and during downloading, the control panel seizes the telephone lines from the house phones, rendering them inoperative during communication. Upon completion of central station communication, the telephone line is restored to the house phones.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

WI1424A 1/06

Page 17

KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP1CAe2/GEM-K1CA and GEM-RP2ASe2/GEM-K2AS Keypads. We recommend that either a GEM-RP1CAe2 or a GEM-K1CA keypad be used for programming.

KEYPAD INSTALLATION

Each keypad must be assigned an address number (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary installation.

GEM-RP1CAe2/GEM-K1CA - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones. A GEMRP1CAe2 or GEM-K1CA is recommended for use with programming.

GEM-RP2ASe2/GEM-K2AS - is a utility LCD keypad combining several preset LCD words with a limited message line. NOTE: Due to space constraints, available messages are abbreviated and will scroll automatically.

CONFIGURING THE KEYPADS

A total of up to 7 keypads may be connected to the panel. GEM-RP1CAe2/GEM-K1CA and GEM-RP2ASe2/GEM-K2AS keypads may be intermixed but require different configuration procedures, as described in the following paragraphs. If you have a GEM-K1CA keypad, please see the "Important Note" on page 5 regarding the differences between the GEM-RP1CAe2 and the GEM-K1CA keypad buttons. The buttons displayed below will be for the GEM-K1CA keypad.

Configuring the GEM-RP1CAe2/GEM-K1CA Keypad

Each GEM-RP1CAe2/GEM-K1CA keypad must be configured for (a) keypad tactile beep; (b) entry

 

sounder; (c) keypad address; (d) EZM address; and (e) zone response.

NORMAL

To enter the GEM-RP1CAe2/GEM-K1CA Configuration Mode:

KEYPAD

1. Move jumper JP1 (located at the upper center of the control panel board) from Pins 1-2 (top two) to

CONFIGURE

Pins 2-3 (bottom two). NOTE: See the Wiring Diagram.

 

2.After about 15 seconds, the display will read “XX OUT OF SYSTEM”, where XX indicates the keypad address.

3.Press 11123Rand proceed as follows. (Repeat the following procedure for all keypads.)

Keypad

Beep

Keypad Tactile Beep

 

ON

Upon entering the Keypad Configuration Mode, “KEYPAD BEEP ON” will be displayed,

 

 

indicating that the tactile beep, which sounds when any button is pressed, is on.

 

 

To turn off the tactile beep, press the Uor Dbutton (the Uor Dbutton will

 

 

toggle the tactile beep on and off). Press the Aor Rbutton to continue

 

 

or press the Cbutton to exit.

Entry

Sounder

Entry Sounder

 

ON

 

To turn off the keypad sounder during entry time, press the Uor Dbutton (the

 

 

Uor Dbutton will toggle the entry sounder on and off). Press the Aor

 

 

Rbutton to continue or press the Cbutton to exit.

Keypad Address

Keypad Address

 

01

 

If more than one keypad is installed, each must be assigned a unique keypad

 

 

address (that is, no two keypads may be numbered alike):

 

 

 

 

keypads must be numbered consecutively (missing numbers are not

 

 

permitted)

To assign the keypad number, proceed as follows:

1.Enter the assigned keypad number 01–07, then press the Uor Dbutton to save. A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep.

2.Press the Aor Rbutton to continue or press the Cbutton to exit.

Mode Configuration Keypad

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

EZM Address

Keypad Configuration Mode

Page 18

 

WI1424A 1/06

 

 

Compatibility Number (Not Applicable)

New

 

Compat #

0000

THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P1664 CON-

 

 

TROL PANEL. DO NOT CHANGE THIS SETTING.

Press the Aor Rbutton to continue or press the Cbutton to exit.

EZM Address

The keypad's internal EZM (Expansion Zone Module) may be utilized to 00 provide four additional wired zones. Whether used alone or in conjunction with optional GEM-EZM series modules or other keypad EZMs, it must be assigned a unique address (or Group number, see Keypad Programming Workbook) similar to its keypad address. If no other EZMs are to be used,

designate the keypad as Group “01” at the “EZM ADDRESS 00” display. In multiple-EZM systems, enter an assigned group number “01” through “14”. (Each EZM must have a unique assigned group number, starting with “01” and proceeding consecutively.) Press the Uor Dbutton to save. Press the Aor Rbutton to continue or press the

Cbutton to exit.

 

 

Zone Response

Zone Response

 

 

The normal loop response of each keypad expansion zone is 750mS,

 

00

 

however the response time of any zone can be reduced to 50mS as

 

 

follows.

 

 

 

 

1. Of the following, circle the number(s) in parentheses associated with

the zone(s) to be changed:

Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)

2.Add up the circled numbers.

3.At the keypad, enter the sum as a two-digit number “01” through “15” on the display, then press the Uor Dbutton.

Example. Change Zones 2, 3 and 4 to 50mS response.

1.Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).

2.Add up the circled numbers: 2 + 4 + 8 = 14.

3.Enter “14” at the keypad, then press the Uor Dbutton.

Press the Aor Rbutton to continue or press the Cbutton to exit.

Note: Panel Zone Response time can also be changed in Direct Address programming (first 8 zones only). See the Programming Instructions WI1422 and WI1423 for more information.

 

 

Program Control Message (Not Applicable)

Program Control

 

 

THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P1664

Message #

1

CONTROL PANEL.

 

 

Press the Rbutton to continue (the display will loop back through

 

 

selections, for changes) or press the Cbutton to exit the Keypad Configuration Mode (display will read “01 OUT OF SYSTEM”). Then replace Jumper JP1 across Pins 1–2 (top two).

X GEM-P1664 Installation Instructions