TESTING |
SMALL POLARIZED RELAY |
TF-RELAYS |
WITH HIGH SENSITIVITY |
9
14 .354
.551
7.8
.307
mm inch
FEATURES
• High sensitivity:
80 mW Nominal operating power (Single side stable 3-12 V type)
• Surge voltage withstand: 1500 V FCC Part 68
•Minimal magnetic interference allows high density mounting
•Sealed construction allows automatic cleaning
•Self-clinching terminal also available
SPECIFICATIONS
Contact
Arrangement |
|
2 Form C |
||
|
|
|||
Initial contact resistance, max. |
50 mΩ |
|||
(By voltage drop 6 V DC 1 A) |
||||
|
||||
|
|
|||
Contact material |
Gold-clad silver |
|||
|
|
|
|
|
|
|
Nominal switching |
1 A 30 V DC, 0.5 A 125 V AC |
|
|
|
capacity (resistive load) |
||
|
|
|
||
|
|
|
|
|
|
|
Max. switching power |
30 W, 62.5 VA |
|
Rating |
|
(resistive load) |
||
|
|
|||
|
|
|
||
|
|
Max. switching voltage |
110 V DC, 125 V AC |
|
|
|
|
|
|
|
|
Max. switching current |
1 A |
|
|
|
|
|
|
|
|
Min. switching capacity 1 |
10 µA 10 mV DC |
|
|
|
|
80 mW (3 to 12 V DC) |
|
|
|
Single side stable |
140 mW (24 V DC) |
|
Nominal |
|
|
260 mW (48 V DC) |
|
|
|
|
||
operating |
|
1 coil latching |
55 mW (3 to 12 V DC) |
|
power |
|
100 mW (24 V DC) |
||
|
|
|||
|
|
|
|
|
|
|
2 coil latching |
110 mW (3 to 12 V DC) |
|
|
|
200 mW (24 V DC) |
||
|
|
|
||
|
|
|
|
|
|
|
Mechanical (at 180 cpm) |
108 |
|
Expected |
|
|
1 A 30 V DC resistive load |
|
life (min. |
Electrical (at 20 cpm) |
2×105 |
||
operations) |
|
|||
0.5 A 125 V AC resistive load |
||||
|
|
|
||
|
|
|
105 |
Note:
1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
Characteristics
Initial insulation resistance*1 |
Min. 1,000 MΩ (at 500 V DC) |
||||||
|
|
|
Between open |
750 Vrms for 1 min. |
|||
Initial |
|
contacts |
|
(Detection current: 10 mA) |
|||
|
|
|
|
|
|||
|
Between contact and |
1,000 Vrms for 1 min. |
|||||
breakdown |
|
||||||
|
coil |
|
(Detection current: 10 mA) |
||||
voltage |
|
|
|||||
|
|
|
|
|
|||
|
Between contact sets |
1,000 Vrms for 1 min. |
|||||
|
|
|
|||||
|
|
|
(Detection current: 10 mA) |
||||
|
|
|
|
|
|
||
|
|
|
|
||||
FCC surge voltage between open |
1,500 V |
||||||
contacts |
|
|
|
||||
|
|
|
|
||||
|
|
||||||
Temperature rise*2 (at 20°C) |
Max. 50°C |
||||||
Operate time [Set time]*3 (at 20°C) |
Max. 4 ms (Approx. 2 ms) |
||||||
[Max. 4 ms (Approx. 2 ms)] |
|||||||
|
|
|
|
|
|
||
|
|
||||||
Release time [Reset time]*4 |
Max. 4 ms (Approx. 1 ms) |
||||||
(at 20°C) |
|
|
|
[Max. 4 ms (Approx. 2 ms)] |
|||
Shock resistance |
|
Functional*5 |
Min. 490 m/s2 {50 G} |
||||
|
Destructive*6 |
Min. 980 m/s2 {100 G} |
|||||
|
|
|
|
|
|||
|
|
|
|
|
Functional*7 |
176.4 m/s2 {18G}, 10 to 55 Hz |
|
|
|
|
|
|
at double amplitude of 3 mm |
||
Vibration resistance |
|
|
|||||
|
|
|
|||||
|
Destructive |
294 m/s2 {30G}, 10 to 55 Hz |
|||||
|
|
|
|
|
|||
|
|
|
|
|
at double amplitude of 5 mm |
||
|
|
|
|
|
|
||
|
|
|
|
||||
Conditions for oper- |
|
Ambient |
–40°C to +70°C |
||||
ation, transport and |
|
||||||
storage*8 |
|
|
temperature |
–40°F to +158°F |
|||
(Not freezing and |
|
|
|
||||
condensing at low |
|
Humidity |
5 to 85% R.H. |
||||
temperature) |
|
|
|||||
|
|
|
|
||||
|
|
|
|
|
|||
Unit weight |
|
|
|
Approx. 2 g .071 oz |
|||
|
|
|
|
|
|||
Remarks |
|
|
|
|
|||
* |
Specifications will vary with foreign standards certification ratings. |
||||||
*1 |
Measurement at same location as "Initial breakdown voltage" section. |
||||||
*2 |
By resistive method, nominal voltage applied to the coil; contact carrying current: |
||||||
|
1 A. |
|
|
|
|
||
*3 |
Nominal voltage applied to the coil, excluding contact bounce time. |
||||||
*4 |
Nominal voltage applied to the coil, excluding contact bounce time without diode. |
||||||
*5 |
Half-wave pulse of sine wave: 11 ms; detection time: 10 s. |
||||||
*6 |
Half-wave pulse of sine wave: 6 ms. |
|
|||||
*7 |
Detection time: 10 s. |
|
|
||||
*8 |
Refer to 4. Conditions for operation, transport and storage mentioned in Cautions |
||||||
|
for use (Page 178). |
|
|
ORDERING INFORMATION
|
Ex. TF |
|
2 |
|
|
L |
|
|
H |
|
3V |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contact arrangement |
|
Operating function |
|
|
|
Terminal shape |
Coil voltage(DC) |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
2:2 Form C |
Nil: Single side stable |
Nil: Standard PC board terminal |
3,4.5,5,6,9,12, |
||||||||||||||||
|
|
|
L: 1 coil latching |
H: Self-clinching terminal |
24,48*V |
||||||||||||||
|
|
L2: 2 coil latching |
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*48 V coil type: Single side stable only
Note: AgPd stationary contact types available for high resistance against contact sticking.
When ordering, please add suffix“-3”like TF2-12V-3.
145
TF
TYPES AND COIL DATA (at 20°C 68°F)
1. Single side stable
Part No. |
Nominal |
Pick-up |
Drop-out |
Nominal |
Coil |
Nominal |
Max. |
||
|
|
operating |
operating |
allowable |
|||||
Standard PC |
Self-clinching |
voltage, |
voltage, |
voltage, |
resistance, |
||||
current, |
power, |
voltage, |
|||||||
board terminal |
terminal |
V DC |
V DC (max.) |
V DC (min.) |
Ω (±10%) |
||||
mA (±10%) |
mW |
V DC |
|||||||
|
|
|
|
|
|
||||
TF2-3 V |
TF2-H-3 V |
3 |
2.25 |
0.3 |
26.7 |
112.5 |
80 |
4.5 |
|
|
|
|
|
|
|
|
|
|
|
TF2-4.5 V |
TF2-H-4.5 V |
4.5 |
3.38 |
0.45 |
17.8 |
253 |
80 |
6.7 |
|
|
|
|
|
|
|
|
|
|
|
TF2-5 V |
TF2-H-5 V |
5 |
3.75 |
0.5 |
16 |
312.5 |
80 |
7.5 |
|
|
|
|
|
|
|
|
|
|
|
TF2-6 V |
TF2-H-6 V |
6 |
4.5 |
0.6 |
13.3 |
450 |
80 |
9 |
|
|
|
|
|
|
|
|
|
|
|
TF2-9 V |
TF2-H-9 V |
9 |
6.75 |
0.9 |
8.9 |
1,012.5 |
80 |
13.5 |
|
|
|
|
|
|
|
|
|
|
|
TF2-12 V |
TF2-H-12 V |
12 |
9 |
1.2 |
6.7 |
1,800 |
80 |
18 |
|
|
|
|
|
|
|
|
|
|
|
TF2-24 V |
TF2-H-24 V |
24 |
18 |
2.4 |
5.8 |
4,100 |
140 |
36 |
|
|
|
|
|
|
|
|
|
|
|
TF2-48 V |
TF2-H-48 V |
48 |
36 |
4.8 |
5.4 |
8,860 |
260 |
57.6 |
|
|
|
|
|
|
|
|
|
|
2. 1 Coil latching
Part No. |
Nominal |
|
|
Nominal |
Coil |
Nominal |
Max. |
||
Standard PC |
Self-clinching |
voltage, |
Set voltage, |
Reset voltage, |
operating |
resistance, |
operating |
allowable |
|
V DC (max.) |
V DC (max.) |
current, |
power, |
voltage, |
|||||
board terminal |
terminal |
V DC |
Ω (±10%) |
||||||
|
|
mA (±10%) |
mW |
V DC |
|||||
|
|
|
|
|
|
||||
TF2-L-3 V |
TF2-L-H-3 V |
3 |
2.25 |
2.25 |
18.3 |
163.6 |
55 |
4.5 |
|
TF2-L-4.5 V |
TF2-L-H-4.5 V |
4.5 |
3.38 |
3.38 |
12.2 |
368.2 |
55 |
6.7 |
|
TF2-L-5 V |
TF2-L-H-5 V |
5 |
3.75 |
3.75 |
11 |
454.5 |
55 |
7.5 |
|
TF2-L-6 V |
TF2-L-H-6 V |
6 |
4.5 |
4.5 |
9.2 |
654.5 |
55 |
9 |
|
TF2-L-9 V |
TF2-L-H-9 V |
9 |
6.75 |
6.75 |
6.1 |
1,472 |
55 |
13.5 |
|
TF2-L-12 V |
TF2-L-H-12 V |
12 |
9 |
9 |
4.6 |
2,618 |
55 |
18 |
|
TF2-L-24 V |
TF2-L-H-24 V |
24 |
18 |
18 |
4.2 |
5,760 |
100 |
36 |
3. 2 Coil latching
Part No. |
Nominal |
|
|
Nominal |
Coil |
Nominal |
Max. |
||
|
|
Set voltage, |
Reset voltage, |
operating |
operating |
allowable |
|||
Standard PC |
Self-clinching |
voltage, |
resistance, |
||||||
V DC (max.) |
V DC (max.) |
current, |
power, |
voltage, |
|||||
board terminal |
terminal |
V DC |
Ω (±10%) |
||||||
|
|
mA (±10%) |
mW |
V DC |
|||||
|
|
|
|
|
|
||||
TF2-L2-3 V |
TF2-L2-H-3 V |
3 |
2.25 |
2.25 |
36.7 |
81.8 |
110 |
4.5 |
|
|
|
|
|
|
|
|
|
|
|
TF2-L2-4.5 V |
TF2-L2-H-4.5 V |
4.5 |
3.38 |
3.38 |
24.4 |
184.1 |
110 |
6.7 |
|
|
|
|
|
|
|
|
|
|
|
TF2-L2-5 V |
TF2-L2-H-5 V |
5 |
3.75 |
3.75 |
22 |
227.3 |
110 |
7.5 |
|
|
|
|
|
|
|
|
|
|
|
TF2-L2-6 V |
TF2-L2-H-6 V |
6 |
4.5 |
4.5 |
18.3 |
327.3 |
110 |
9 |
|
|
|
|
|
|
|
|
|
|
|
TF2-L2-9 V |
TF2-L2-H-9 V |
9 |
6.75 |
6.75 |
12.2 |
736.4 |
110 |
13.5 |
|
|
|
|
|
|
|
|
|
|
|
TF2-L2-12 V |
TF2-L2-H-12 V |
12 |
9 |
9 |
9.2 |
1,309 |
110 |
18 |
|
|
|
|
|
|
|
|
|
|
|
TF2-L2-24 V |
TF2-L2-H-24 V |
24 |
18 |
18 |
8.3 |
2,880 |
200 |
36 |
|
|
|
|
|
|
|
|
|
|
Notes:
1.Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
2.Standard packing: Tube: 50 pcs.; Case; 1,000 pcs.
3.In case of 5 V drive circuit, it is recommended to use 4.5 V type relay.
4.AgPd stationary contact types available for high resistance against contact sticking. When ordering, please add suffix "-3" like TF2-12V-3.
DIMENSIONS
mm inch
|
Standard PC board terminal |
PC board pattern |
|
10.16 |
10-1.0 dia |
|
|
|
|
(Copper-side view) |
2.54 |
||
|
|
|
.400 |
|||
|
14 |
|
10-.039 dia |
|||
|
9 |
|
.100 |
|
||
|
.551 |
|
|
|
|
|
|
.354 |
|
|
|
|
|
|
|
|
|
|
|
|
7.8 |
|
7.1 |
|
|
|
7.62 |
.307 |
|
.280 |
|
|
|
.300 |
|
|
|
|
|
||
3.5 |
|
|
|
|
|
2.54 |
.138 |
|
|
|
|
|
|
|
|
|
|
|
.100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7.62 |
0.25 |
|
|
2.54 |
0.5 |
|
.300 |
|
|||||||||
.100 |
.020 |
|
|
|
.010 |
Schematic (Bottom view) |
|||||||
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Single side stable |
1-coil latching |
|
|
|
Self-clinching terminal |
|
|
(Deenergized condition) |
(Reset condition) |
Tolerance: ±0.1 ±.004
2-coil latching (Reset condition)
7.8 |
|
7.1 |
|
+ 1 2 |
3 |
4 |
5 |
– 1 2 |
3 |
4 |
5 |
1 2 |
3 |
4 |
5 |
.307 |
|
.280 |
|
|
|
|
|
|
|
|
|
+ |
|
|
– |
3.5 |
|
|
|
–10 9 |
|
|
|
|
|
|
|
+ |
|
|
– |
.138 |
|
|
|
|
|
|
+ 10 9 |
|
|
|
|
|
|||
2.54 |
0.5 |
7.62 |
0.25 |
8 |
7 |
6 |
8 |
7 |
6 |
10 9 |
8 |
7 |
6 |
||
.300 |
|
|
|
|
|
|
|
|
|
|
|
|
|||
.100 |
.020 |
|
.010 |
Direction indication* |
|
Direction indication* |
|
Direction indication* |
|||||||
|
|
|
|
|
|
||||||||||
|
General tolerance: ±0.3 ±.012 |
|
|
|
|
*Orientation stripe typical-located on top of relay. |