NAIS PQ1a-12V, PQ1a-18V, PQ1a-24V, PQ1a-3V, PQ1a-5V Datasheet

...
0 (0)
NAIS PQ1a-12V, PQ1a-18V, PQ1a-24V, PQ1a-3V, PQ1a-5V Datasheet

VDE

HIGH ELECTRICAL &

MECHANICAL NOISE PQ-RELAYS

IMMUNITY RELAY

20

10

.787

.394

15.6

.614

FEATURES

High electrical noise immunity

Bifurcated contact type with higher contact reliability

High switching capacity: 5 A 250 V AC

High sensitivity: 200 mW (Nominal)

High surge voltage between contacts and coil: 8,000 V

Compatible with DS-P relay terminal layout

mm inch

SPECIFICATIONS

Contacts

Arrangement

 

1 Form A (Bifurcated)

Contact material

 

Silver alloy

Initial contact resistance, max.

50 mΩ

(By voltage drop 6 V DC 1 A)

 

 

Nominal switching capacity

5 A 250 V AC, 5 A 30 V DC

Rating

Max. switching power

1,250 VA, 150 W

(resistive)

Max. switching voltage

250 V AC, 110 V (0.3 A)

 

Min. switching capacity**1

100 µA 100mV DC

Expected

Mechanical (at 180 cpm)

2 × 107

life (min.

Electrical

 

5 A 125 V AC

2 × 105

ope.)

(at 20 cpm)

 

5 A 250 V AC

105

Coil (at 20°C 68°F)

 

 

 

 

 

Nominal operating power

 

200 mW

 

 

 

 

 

Notes:

**1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.

Remarks

* Specifications will vary with foreign standards certification ratings.

*1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10mA

*3 Wave is standard shock voltage of ± 1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time

*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs *6 Half-wave pulse of sine wave: 6ms

*7 Detection time: 10µs

*8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).

Characteristics

Max. operating speed

 

 

20 cpm at rated load

Initial insulation resistance*1

Min. 1,000 MΩ at 500 V DC

Initial

Between open contacts

1,000 Vrms

breakdown

Between contacts and

4,000 Vrms

voltage*2

coil

 

 

Surge voltage between contacts and

Min. 8,000 V

coil*3

 

 

 

 

 

 

 

 

 

Operate time*4 (at nominal voltage)

Approx. 4 ms

Release time (without diode)*4

Approx. 2 ms

(at nominal voltage)

 

 

 

 

 

Temperature rise

 

 

Max. 65°C

(Resistive at nominal voltage, contact

carrying current: 5 A, at 70°C)

 

Shock resistance

 

Functional*5

Min. 294 m/s2 {30 G}

 

Destructive*6

Min. 980 m/s2 {100 G}

 

 

 

 

 

 

Functional*7

117.6 m/s2 {12 G}, 10 to 55 Hz

 

 

 

at double amplitude of 2.0 mm

Vibration resistance

 

 

 

 

Destructive

205.8 m/s2 {21 G}, 10 to 55 Hz

 

 

 

 

 

 

at double amplitude of 3.5 mm

 

 

 

 

 

Conditions for operation,

 

Ambient

–40°C to +70°C

transport and storage*8

 

temp.

–40°F to +158°F

(Not freezing and condens-

Humidity

5 to 85%R.H.

ing at low temperature)

 

 

 

 

Unit weight

 

 

 

 

Approx. 7 g .25 oz

TYPICAL APPLICATIONS

Programmable controllers

Interface relays for Factory Automation and Communication equipment

Output relays for measuring equipment, timers, counters and temperature controllers

ORDERING INFORMATION

Ex. PQ

1a

 

12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact arrangement

 

 

Coil voltage (DC)

1a: 1 Form A

3, 5, 6, 9, 12, 18, 24 V

(Bifurcated)

Note: Standard packing: Carton: 100 pcs.; Case: 500 pcs. UL/CSA, VDE, SEMKO approved type is standard.